Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record.

Fingerstick Glucose Determination in Shock

Atkin, Suzanne H., Dasmahapatra, Amita, Jaker, Michael A., Chorost, Mitchell I., Reddy, Suman·1991·Annals of Internal Medicine

Abstract

OBJECTIVE: To evaluate the accuracy of fingerstick glucose measurements in severely hypotensive patients. DESIGN: Prospective, nonrandomized comparison study. SETTING: Emergency department in a university hospital. PATIENTS: Twenty-five severely hypotensive patients (systolic blood pressure less than or equal to 80 mm Hg) and 39 normotensive patients. MEASUREMENTS: Simultaneous fingerstick reagent strip glucose, venous reagent strip glucose, and laboratory glucose values were compared. Data were analyzed using error-grid analysis. RESULTS: In hypotensive patients, the mean fingerstick glucose values were significantly lower than the values obtained either by venous reagent strip or laboratory glucose measurements. Fingerstick glucose values in the hypotensive group were 67.5% of laboratory glucose values, and were significantly lower than the values obtained in the normotensive group (91.8%, P less than 0.001). Only 36% of the hypotensive patients had fingerstick glucose values within the acceptable range of 20% of the laboratory glucose value. Thirty-two percent of hypotensive patients were incorrectly diagnosed as hypoglycemic (glucose less than 3.89 mmol/L [70 mg/dL]); 2 of these patients were actually hyperglycemic (glucose greater than 11.10 mmol/L [200 mg/dL]). Venous reagent strip measurements accurately reflected laboratory glucose values in both hypotensive and normotensive patients. CONCLUSIONS: Fingerstick glucose testing does not accurately represent venous glucose levels in severely hypotensive patients. If fingerstick glucose testing is relied on for these patients, errors in clinical management may be made. Venous reagent strip glucose testing correlates well with laboratory glucose measurements and should be the preferred method for rapid assessment of glucose level in critically ill patients with severe hypotension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-114-12-1020

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 189

Metadata

Authors
Atkin, S. H., Dasmahapatra, A., Jaker, M. A., Chorost, M. I., & Reddy, S.
Venue
Annals of Internal Medicine
Published
1991-06-15
Volume
114
Issue
12
Pages
1020-1024
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1975257851
Cited by
189
References
0
FWCI
1.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fingerstick Glucose Determination in Shock. https://app.cochat.ai/papers/10.7326/0003-4819-114-12-1020
The paper
Atkin, S. H., Dasmahapatra, A., Jaker, M. A., Chorost, M. I., & Reddy, S. (1991). Fingerstick Glucose Determination in Shock. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-114-12-1020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.