Fingerstick Glucose Determination in Shock
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the accuracy of fingerstick glucose measurements in severely hypotensive patients. DESIGN: Prospective, nonrandomized comparison study. SETTING: Emergency department in a university hospital. PATIENTS: Twenty-five severely hypotensive patients (systolic blood pressure less than or equal to 80 mm Hg) and 39 normotensive patients. MEASUREMENTS: Simultaneous fingerstick reagent strip glucose, venous reagent strip glucose, and laboratory glucose values were compared. Data were analyzed using error-grid analysis. RESULTS: In hypotensive patients, the mean fingerstick glucose values were significantly lower than the values obtained either by venous reagent strip or laboratory glucose measurements. Fingerstick glucose values in the hypotensive group were 67.5% of laboratory glucose values, and were significantly lower than the values obtained in the normotensive group (91.8%, P less than 0.001). Only 36% of the hypotensive patients had fingerstick glucose values within the acceptable range of 20% of the laboratory glucose value. Thirty-two percent of hypotensive patients were incorrectly diagnosed as hypoglycemic (glucose less than 3.89 mmol/L [70 mg/dL]); 2 of these patients were actually hyperglycemic (glucose greater than 11.10 mmol/L [200 mg/dL]). Venous reagent strip measurements accurately reflected laboratory glucose values in both hypotensive and normotensive patients. CONCLUSIONS: Fingerstick glucose testing does not accurately represent venous glucose levels in severely hypotensive patients. If fingerstick glucose testing is relied on for these patients, errors in clinical management may be made. Venous reagent strip glucose testing correlates well with laboratory glucose measurements and should be the preferred method for rapid assessment of glucose level in critically ill patients with severe hypotension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Consensus Statement on Self-Monitor ing of Blood Glucose
(1987) · Diabetes Care · doi:10.2337/diacare.10.1.95 · Cited by 248
Accuracy of Perceiving Blood Glucose in IDDM
Cox, D. J., Clarke, W. L., Gonder-Frederick, L., Pohl, S., Hoover, C., Snyder, A., Zimbelman, L., Carter, W. R., Bobbitt, S., & Pennebaker, J. (1985) · Diabetes Care · doi:10.2337/diacare.8.6.529 · Cited by 169
Blood Sugar and Insulin Response of Humans in Shock
Carey, L. C., Bd, L., & Cloutier, C. T. (1970) · Annals of Surgery · doi:10.1097/00000658-197009000-00004 · Cited by 117
Blood insulin responses to blood glucose levels in high output sepsis and septic shock
Gh, C., Martin, H., Walji, S., Hirsch, E. F., Gazitua, R., & Goodfellow, R. M. (1978) · The American Journal of Surgery · doi:10.1016/0002-9610(78)90040-5 · Cited by 63
A Comparison of Accuracy and Estimated Cost of Methods for Home Blood Glucose Monitoring
Shapiro, B., Savage, P. J., Lomatch, D. L., Gniadek, T. J., Forbes, R., Mitchell, R. J., Hein, K., Starr, R., Nutter, M., & Scherdt, B. (1981) · Diabetes Care · doi:10.2337/diacare.4.3.396 · Cited by 61
50% dextrose: Antidote or toxin?
BROWNING, R., OLSON, D., Stueven, H. A., & Mateer, J. R. (1990) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)82479-5 · Cited by 48
New Approach to Technical and Clinical Evaluation of Devices for Self-Monitoring of Blood Glucose
Koschinsky, T., Dannehl, K., & Gries, F. A. (1988) · Diabetes Care · doi:10.2337/diacare.11.8.619 · Cited by 48
Clarification of Error-Grid Analysis
Cox, D. J., Richards, F. E., Gonder-Frederick, L. A., Julian, D. M., Carter, W. R., & Clarke, W. L. (1989) · Diabetes Care · doi:10.2337/diacare.12.3.235 · Cited by 28
Self-monitoring of the blood glucose level: potential sources of inaccuracy.
Rasaiah, B. (1985) · PubMed Central · Cited by 24
Cited by
Management of diabetes and hyperglycemia in hospitals.
Clement, S., Braithwaite, S. S., Magee, M. F., Ahmann, A., Smith, E. P., Schafer, R. G., Hirsch, I. B., & on behalf of the Diabetes in Hospitals Writing Committee (2004) · Diabetes Care · doi:10.2337/diacare.27.2.553 · Cited by 1,266
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Reliability of point-of-care testing for glucose measurement in critically ill adults*
Kanji, S., Buffie, J., Hutton, B., Bunting, P. S., Singh, A., McDonald, K., Fergusson, D., McIntyre, L. A., & Hebert, P. C. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000189939.10881.60 · Cited by 395
Maiti, R., Jana, D., Das, U. K., & Ghosh, D. (2004) · Journal of Ethnopharmacology · doi:10.1016/j.jep.2004.02.002 · Cited by 340
Tang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Tang, Z., Du, X., Louie, R. F., & Kost, G. J. (2000) · American Journal of Clinical Pathology · doi:10.1309/qaw1-x5xw-bvrq-5lkq · Cited by 207
Accuracy of bedside glucose measurement from three glucometers in critically ill patients*
Hoedemaekers, C. W. E., Klein Gunnewiek, J. M. T., Prinsen, M. A., Willems, J. L., & Van der Hoeven, J. G. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318186ffe6 · Cited by 165
Corstjens, A. M., Ligtenberg, J. J., van der Horst, I. C., Spanjersberg, R., Lind, J. S., Tulleken, J. E., Meertens, J. H., & Zijlstra, J. G. (2006) · Critical Care · doi:10.1186/cc5048 · Cited by 163
Maiti, R., Das, U. K., & Ghosh, D. (2005) · Biological and Pharmaceutical Bulletin · doi:10.1248/bpb.28.1172 · Cited by 160
Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198034 · Cited by 158
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Metadata
- Authors
- Atkin, S. H., Dasmahapatra, A., Jaker, M. A., Chorost, M. I., & Reddy, S.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1991-06-15
- Volume
- 114
- Issue
- 12
- Pages
- 1020-1024
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1975257851
- Cited by
- 189
- References
- 14
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.