Diagnostic Yield and Optimal Duration of Continuous-Loop Event Monitoring for the Diagnosis of Palpitations: A Cost-Effectiveness Analysis
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous-loop event recorders are widely used for the evaluation of palpitations, but the optimal duration of monitoring is unknown. OBJECTIVE: To determine the yield, timing, and incremental cost-effectiveness of each week of event monitoring for palpitations. DESIGN: Prospective cohort study. PATIENTS: 105 consecutive outpatients referred for the placement of a continuous-loop event recorder for the evaluation of palpitations. MEASUREMENTS: Diagnostic yield, incremental cost, and cost-effectiveness for each week of monitoring. RESULTS: The diagnostic yield of continuous-loop event recorders was 1.04 diagnoses per patient in week 1, 0.15 diagnoses per patient in week 2, and 0.01 diagnoses per patient in week 3 and beyond. Over time, the cost-effectiveness ratio increased from $98 per new diagnosis in week 1 to $576 per new diagnosis in week 2 and $5832 per new diagnosis in week 3. CONCLUSIONS: In patients referred for evaluation of palpitations, the diagnostic yield of continuous-loop event recording decreases rapidly after 2 weeks of monitoring. A 2-week monitoring period is reasonably cost-effective for most patients and should be the standard period for continuous-loop event recording for the evaluation of palpitations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Zimetbaum et al. found that 80% of their patients examined for palpitations had at least one diagnostic event during the first week of monitoring. 4”
In the citing paper
“The optimal monitoring time for cardiac event recorders in the examination of sporadic palpitations was found to be 2 weeks.”
In the citing paper
“It has been shown that 2 weeks of ECG monitoring provide the best balance between diagnostic yield and associated cost (Zimetbaum et al., 1998).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Zimetbaum et al., 1998
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
In the citing paper
“After this period, there is very little additional diagnostic yield compared with rapidly rising costs. 4”
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Clinical Economics: A Guide to the Economic Analysis of Clinical Practices
Eisenberg, J. M. (1989) · JAMA · doi:10.1001/jama.1989.03430200123038 · Cited by 690
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245 · cited 4×
“Because previous studies have shown loop recording to be less costly and more effective than Holter monitoring for the diagnosis of palpitations (1), we did not consider Holter monitoring as an alternative strategy in the cost-effectiveness analysis.”
BackgroundMethodInfluentialThe etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Use of ambulatory electrocardiographic (Holter) monitoring
DiMarco, J. P., & Philbrick, J. T. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-1-53 · Cited by 177 · cited 1×
“Holter monitoring is routinely used to identify the cause of palpitations, but palpitations are often sporadic and may not occur during the 24 to 48 hours of conventional Holter monitoring (1, 2).”
MethodUtility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope
Fogel, R. I., Evans, J. J., & Prystowsky, E. N. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00717-5 · Cited by 83 · cited 1×
“Patient-activated continuous-loop event recorders allow more prolonged surveillance and have proven to be more efficacious and cost-effective than Holter monitoring for the diagnosis of palpitations (1, 3), but the optimal duration of event recording for the indication of palpitations has yet to be defined.”
BackgroundReiffel, J. A., Schulhof, E., Joseph, B., Severance, E., Wyndus, P., & McNamara, A. (1991) · Journal of Electrocardiology · doi:10.1016/0022-0736(91)90007-9 · Cited by 36 · cited 1×
“Although a 1-month monitoring period has been shown to be sufficient to capture even infrequent arrhythmias (6), our study shows that a shorter period may be equally safe and effective at a much lower cost to the health care system.”
Background
Cited by
Items 101–145 of 145
Background 2: Telemedical Solutions in Cardiac Diagnostics
Augustyniak, P., & Tadeusiewicz, R. (2009) · IGI Global eBooks · doi:10.4018/978-1-60566-080-6.ch003 · Cited by 1
Approach to Palpitations in Pregnancy
Sia, W. W., Gibson, P., & Khurana, R. (2010) · Wiley eBooks · doi:10.1002/9781444323016.ch40 · Cited by 1
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.009 · Cited by 1
Tools for Assessment of Cardiovascular Tests and Therapies
Antman, E. M., Califf, R. M., & Kupersmith, J. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-3358-5.50007-3 · Cited by 1
Kardiyak Olay Kaydedici ve Telemetri Sistemi için Yeni Bir Bileklik Tasarımı
BİLGİN, G., Oktay, M., & Bilgin, S. (2021) · Mehmet Akif Ersoy Üniversitesi Fen Bilimleri Enstitüsü Dergisi · doi:10.29048/makufebed.889637 · Cited by 1
Implantable cardiac monitors: State of the art
Jamal, S. M., Prasad, R. M., Vipparla, N. S., Srivastava, S., Baloch, Z. Q., Banga, E., & Ip, J. H. (2021) · Interventional Cardiology · Cited by 1
Paroxysmal Tachycardia Diagnosed by ECG247 Smart Heart Sensor in a Previously Healthy Child
Jortveit, J., Früh, A., & Odland, H. H. (2022) · Case Reports in Pediatrics · doi:10.1155/2022/9027255 · Cited by 1
Lucassen, W. A. M., Himmelreich, J. C. L., Harskamp, R. E., & Selder, J. L. (2021) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2620-4_30 · Cited by 1
Effiziente Synkopenabklärung: Wann soll der implantierbare Loop-Rekorder verwendet werden?
Pezawas, T., & Schmidinger, H. (2004) · Journal für Kardiologie (Krause & Pachernegg GmbH) · Cited by 1
不整脈疾患におけるホルター心電図に対するイベントレコーダーの費用対効果分析
Nakaji, G., Fujihara, M., Fukata, M., Yasuda, S., Odashiro, K., Maruyama, T., Akashi, K., & Babazono, A. (2010) · Japanese Journal of Electrocardiology · doi:10.5105/jse.30.216 · Cited by 1
Ambulatory Electrocardiography, Transient Event Monitors, and Continuous Loop Recorders
Kreeger, R. W., Brooks, J., & Movahed, A. (2008) · Springer eBooks · doi:10.1007/978-3-540-78674-0_9
Usadel, L. (2014) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-5159
Diagnosing arrhythmias in general practice: the BEAT study
Hoefman, E. (2013) · Data Archiving and Networked Services (DANS)
Il cardiopalmo: iter diagnostico
Giada, F., & Raviele, A. (2010) · Giornale Ialiano di Cardiologia · doi:10.1714/660.7680
Laksomya, T., Krittayaphong, R., Winijkul, A., & Yindeengam, A. (2010)
Long-Term ECG (Holter) Monitoring and Head-Up Tilt Test
Dora, S. K. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5316-0_12
Continuous-Loop Recorders: Two Weeks Are Enough.
Saitz, R. (1998) · Journal watch · doi:10.1056/jw199806190000005
Value of Ambulatory Electrocardiogra phic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013)
Epifanio, H. B., Katz, M., Borges, M. A., Corrêa, A. D. G., Cintra, F. D., Grinberg, R. L., Pinotti, C. M., Ludovice, P., Valdigem, B. P., da Silva, N. J. C., et al. (2014)
What Is the Optimum Duration of Continuous-Loop Event Monitoring?
Lauer, M. S. (1998) · Journal watch · doi:10.1056/jc199806190000003
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2018) · Cardiology News Opinions Training · doi:10.24411/2309-1908-2018-00001
Value of a Novel 7-Day Patch Electrocardiography on Monitoring Cardiac Arrhythmias
Zhang, X., Zhao, Y., Yan, J., Chen, X., Xiong, Y., Zheng, P. P., Xing, J., Chen, D., Weng, J., Zhang, W., et al. (2020)
EKG:n pitkäaikaisrekisteröinti
Korhonen, P., Raatikainen, P. M. J., & Viitasalo, M. T. (2021) · Helda - University of Helsinki Institutional Repository
Is an underlying cardiac condition causing your patient’s palpitations?
Narducci (2021) · The Journal of Family Practice · doi:10.12788/jfp.0152
Chest Pain, Dyspnea, Palpitations
Hanna, E. B. (2022) · Wiley eBooks · doi:10.1002/9781119832737.ch27
Behrendt, I., & Plappert, T. (2020) · Elsevier eBooks · doi:10.1016/b978-3-437-23248-0.00043-2
van Weert, H. C. P. M., & Peters, R. J. G. (2016) · Kernboek · doi:10.1007/978-90-368-1274-0_24
Pines, J. M., Carpenter, C. R., Raja, A. S., & Schuur, J. D. (2012) · Wiley eBooks · doi:10.1002/9781118482117.ch24
Jonovich, M. R., & HALL, B. W. (2011) · Springer eBooks · doi:10.1007/978-0-85729-944-4_15
van Weert, H. C. P. M., & Peters, R. J. G. (2011) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-8364-1_24
van Weert, H. C. P. M., & Peters, R. J. G. (2007) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-6530-2_28
Chest Pain, Dyspnea, Palpitations
Hanna, E. B. (2017) · Wiley eBooks · doi:10.1002/9781119233503.ch27
Ambulatory Electrocardiography
Rho, R. W., & Page, R. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00071-5
Bénali, K., & Guénancia, C. (2022) · EMC - Tratado de Medicina · doi:10.1016/s1636-5410(22)46832-2
Bénali, K., & Guénancia, C. (2022) · EMC - AKOS - Trattato di Medicina · doi:10.1016/s1634-7358(22)46915-4
Probst, M. A., & Carpenter, C. R. (2023) · Wiley eBooks · doi:10.1002/9781119616870.ch22
Poliner, M. C., Bhutta, R., Gomaa, M., & Afzal, M. R. (2025) · Expert Review of Medical Devices · doi:10.1080/17434440.2025.2580494
Utility of wireless ECG event recording system in children
Çongur, E. Ç., Şahin, M., Yilancioğlu, Ş. K., & Çeliker, A. (2015) · Journal of Indian College of Cardiology · doi:10.1016/j.jicc.2015.05.003
The Diagnosis of Cardiac Arrhythmias
Richardson, A., & ZIMETBAUM, P. J. (2002) · Contemporary cardiology · doi:10.1007/978-1-59259-090-2_2
Self-citationRichtlinien für den Event-/Loop-Recorder
Nürnberg, M. (2002) · Journal für Kardiologie (Krause & Pachernegg GmbH)
Utilitat del holter de 72 hores a la pràctica clínica habitual
Punti Sala, J., de Medicina, U. A. D. B. D., & de Medicina, U. A. D. B. F. (2013) · Dipòsit Digital de Documents de la UAB (Universitat Autònoma de Barcelona)
Holter implantable: reveal [The implantable loop recorder]
Graf, D., Roussianos, M. O., Schläpfer, J., Forclaz, A., Zerm, T., Metzger, J., FROMER, M. A., & Pruvot, E. (2007) · SERVAL (Université de Lausanne)
Himmelreich, J. C. L., Lucassen, W. A. M., & Harskamp, R. E. (2026) · doi:10.1007/978-90-368-3158-1_28
Utility of an automatic and patient-triggered cardiac event recorder: experience in children
Elkıran, Ö., & Öncül, M. (2026) · BMC Pediatrics · doi:10.1186/s12887-026-07447-5
Chest Pain, Dyspnea, Palpitations
(2026) · Wiley eBooks · doi:10.1002/9781394406999.ch27
Metadata
- Authors
- Zimetbaum, P. J., Kim, K. Y., Josephson, M. E., Goldberger, A. L., & Cohen, D. J.
- Affiliations
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Zimetbaum, Peter J.
- ORCID
- Zimetbaum, Peter J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1998-06-01
- Volume
- 128
- Issue
- 11
- Pages
- 890-895
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1967172540
- Semantic Scholar
- b44b7bcb7010ab254a947d46614a6734e6a2eadb
- Cited by
- 133
- References
- 7
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 6 · 2021: 12 · 2020: 3 · 2019: 6 · 2018: 5 · 2017: 7 · 2016: 4 · 2015: 4 · 2014: 9 · 2013: 8 · 2012: 5
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- palpitations, diagnostic yield, monitoring duration, cost-effectiveness, event data recorders, arrhythmia diagnosis, incremental cost-effectiveness ratio
- MeSH terms
- Adult, Aged, Arrhythmias, Cardiac, Cost-Benefit Analysis, Costs and Cost Analysis, Female, Humans, Male, Middle Aged, Prospective Studies, Time Factors, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.