Diagnostic Yield and Optimal Duration of Continuous-Loop Event Monitoring for the Diagnosis of Palpitations: A Cost-Effectiveness Analysis
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous-loop event recorders are widely used for the evaluation of palpitations, but the optimal duration of monitoring is unknown. OBJECTIVE: To determine the yield, timing, and incremental cost-effectiveness of each week of event monitoring for palpitations. DESIGN: Prospective cohort study. PATIENTS: 105 consecutive outpatients referred for the placement of a continuous-loop event recorder for the evaluation of palpitations. MEASUREMENTS: Diagnostic yield, incremental cost, and cost-effectiveness for each week of monitoring. RESULTS: The diagnostic yield of continuous-loop event recorders was 1.04 diagnoses per patient in week 1, 0.15 diagnoses per patient in week 2, and 0.01 diagnoses per patient in week 3 and beyond. Over time, the cost-effectiveness ratio increased from $98 per new diagnosis in week 1 to $576 per new diagnosis in week 2 and $5832 per new diagnosis in week 3. CONCLUSIONS: In patients referred for evaluation of palpitations, the diagnostic yield of continuous-loop event recording decreases rapidly after 2 weeks of monitoring. A 2-week monitoring period is reasonably cost-effective for most patients and should be the standard period for continuous-loop event recording for the evaluation of palpitations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Zimetbaum et al. found that 80% of their patients examined for palpitations had at least one diagnostic event during the first week of monitoring. 4”
In the citing paper
“The optimal monitoring time for cardiac event recorders in the examination of sporadic palpitations was found to be 2 weeks.”
In the citing paper
“It has been shown that 2 weeks of ECG monitoring provide the best balance between diagnostic yield and associated cost (Zimetbaum et al., 1998).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Zimetbaum et al., 1998
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
In the citing paper
“After this period, there is very little additional diagnostic yield compared with rapidly rising costs. 4”
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Clinical Economics: A Guide to the Economic Analysis of Clinical Practices
Eisenberg, J. M. (1989) · JAMA · doi:10.1001/jama.1989.03430200123038 · Cited by 690
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245 · cited 4×
“Because previous studies have shown loop recording to be less costly and more effective than Holter monitoring for the diagnosis of palpitations (1), we did not consider Holter monitoring as an alternative strategy in the cost-effectiveness analysis.”
BackgroundMethodInfluentialThe etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Use of ambulatory electrocardiographic (Holter) monitoring
DiMarco, J. P., & Philbrick, J. T. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-1-53 · Cited by 177 · cited 1×
“Holter monitoring is routinely used to identify the cause of palpitations, but palpitations are often sporadic and may not occur during the 24 to 48 hours of conventional Holter monitoring (1, 2).”
MethodUtility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope
Fogel, R. I., Evans, J. J., & Prystowsky, E. N. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00717-5 · Cited by 83 · cited 1×
“Patient-activated continuous-loop event recorders allow more prolonged surveillance and have proven to be more efficacious and cost-effective than Holter monitoring for the diagnosis of palpitations (1, 3), but the optimal duration of event recording for the indication of palpitations has yet to be defined.”
BackgroundReiffel, J. A., Schulhof, E., Joseph, B., Severance, E., Wyndus, P., & McNamara, A. (1991) · Journal of Electrocardiology · doi:10.1016/0022-0736(91)90007-9 · Cited by 36 · cited 1×
“Although a 1-month monitoring period has been shown to be sufficient to capture even infrequent arrhythmias (6), our study shows that a shorter period may be equally safe and effective at a much lower cost to the health care system.”
Background
Cited by
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Kadish, A. H., Buxton, A. E., Kennedy, H. L., Knight, B. P., Mason, J. W., Schuger, C. D., Tracy, C. M., Winters, W. L., Boone, A. W., Elnicki, M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01680-1 · Cited by 244
“) By contrast, for patients with infrequent symptoms, intermittent event recorders may be more cost-effective in evaluating the cause of symptoms (40).”
BackgroundAmbulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
Self-citationROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Committee Members, Kadish, A. H., Buxton, A. E., Kennedy, H. L., Knight, B. P., Mason, J. W., Schuger, C. D., Tracy, C. M., Winters, W. L., Boone, A. W., et al. (2001) · Circulation · doi:10.1161/circ.104.25.3169 · Cited by 192
ROSENBERG, M. A., SAMUEL, M., THOSANI, A., & ZIMETBAUM, P. J. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12053 · Cited by 179
Self-citationHoch, J. S., Rockx, M. A., & Krahn, A. D. (2006) · BMC Health Services Research · doi:10.1186/1472-6963-6-68 · Cited by 163
Sivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00233-x · Cited by 160
Raviele, A., Giada, F., Bergfeldt, L., Blanc, J. J., Blomstrom-Lundqvist, C., Mont, L., Morgan, J. M., Raatikainen, M. J. P., Steinbeck, G., Viskin, S., et al. (2011) · Europace · doi:10.1093/europace/eur130 · Cited by 149
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Zimetbaum, P. J., & Josephson, M. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-10-199905180-00020 · Cited by 139
Self-citationSteinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 133
Barthélémy, J., Féasson‐Gérard, S., Garnier, P., Gaspoz, J., Costa, A. D., Michel, D., & Roche, F. (2003) · Annals of Noninvasive Electrocardiology · doi:10.1046/j.1542-474x.2003.08305.x · Cited by 105
ROCHE, F., GASPOZ, J., DA COSTA, A., ISAAZ, K., DUVERNEY, D., PICHOT, V., COSTES, F., LACOUR, J., & BARTHÉLÉMY, J. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01587.x · Cited by 101
Diagnostic approach to palpitations.
Abbott, A. V. (2005) · PubMed · Cited by 99
Locati, E. T., Moya, A., Oliveira, M., Tanner, H., Willems, R., Lunati, M., & Brignole, M. (2016) · Europace · doi:10.1093/europace/euv311 · Cited by 95
Diretrizes para Avaliação e Tratamento de Pacientes com Arritmias Cardíacas
Feitosa, G. S., Nicolau, J. C., Lorga, A. M., Filho, A. L., d’Ávila, A., Rassi, A., de Paola, Â. A. V., Pedrosa, A., da Costa, Á. B., Péres, A. K., et al. (2002) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2002001900001 · Cited by 98
Kamel, H., Hegde, M., Johnson, D. R., Gage, B. F., & Johnston, S. C. (2010) · Stroke · doi:10.1161/strokeaha.110.582437 · Cited by 82
Does this patient with palpitations have a cardiac arrhythmia?
Thavendiranathan, P. (2009) · JAMA · doi:10.1001/jama.2009.1673 · Cited by 75
“A 2-week loop recorder had a greater yield than a 1-week recorder, however, using it for 3 weeks had minimal(49) or no additional yield.(47) The use of loop recorders with an automatic trigger function for asymptomatic arrhythmias had a slightly higher yield for clinically significant arrhythmias.”
BackgroundSCHUCHERT, A., MAAS, R., KRETZSCHMAR, C., BEHRENS, G., KRATZMANN, I., & MEINERTZ, T. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00277.x · Cited by 62
Long-term continuous external electrocardiographic recording: a review
Enseleit, F., & Duru, F. (2006) · EP Europace · doi:10.1093/europace/euj054 · Cited by 62
Rockx, M. A., Hoch, J. S., Klein, G. J., Yee, R., Skanes, A. C., Gula, L. J., & Krahn, A. D. (2005) · American Heart Journal · doi:10.1016/j.ahj.2005.08.003 · Cited by 60
OLSON, J. A., FOUTS, A. M., PADANILAM, B. J., & PRYSTOWSKY, E. N. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00779.x · Cited by 59
External loop recorders: determinants of diagnostic yield in patients with syncope
Gula, L. J., Krahn, A. D., Massel, D. R., Skanes, A. C., Yee, R. K., & Klein, G. J. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.10.036 · Cited by 58
Reed, M. J., Grubb, N. R., Lang, C. C., O'Brien, R., Simpson, K., Padarenga, M., Grant, A., Tuck, S., Keating, L., Coffey, F., et al. (2019) · EClinicalMedicine · doi:10.1016/j.eclinm.2019.02.005 · Cited by 57
Efficacy of diagnostic tools for detecting cardiac arrhythmias: systematic literature search
Hoefman, E., Bindels, P., & van Weert, H. C. P. M. (2010) · Netherlands Heart Journal · doi:10.1007/s12471-010-0831-0 · Cited by 56
de Asmundis, C., Conte, G., Sieira, J., Chierchia, G.-B., Rodriguez-Manero, M., Di Giovanni, G., Ciconte, G., Levinstein, M., Baltogiannis, G., Saitoh, Y., et al. (2014) · Europace · doi:10.1093/europace/eut411 · Cited by 52
Saarel, E. V., Stefanelli, C. B., Fischbach, P. S., Serwer, G. A., Rosenthal, A., & Dick, M. (2004) · Pediatrics · doi:10.1542/peds.113.2.248 · Cited by 51
The Diagnostic Significance of the Holter Monitoring in the Evaluation of Palpitation
Paudel, B., & Paudel, K. (2013) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2013/4923.2802 · Cited by 47
Comparing 14-day Adhesive Patch With 24-h Holter Monitoring
Cheung, C. C., Kerr, C. R., & Krahn, A. D. (2014) · Future Cardiology · doi:10.2217/fca.14.24 · Cited by 46
Scherr, D., Dalal, D., Henrikson, C. A., Spragg, D. D., Berger, R. D., Calkins, H., & Cheng, A. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9251-0 · Cited by 45
“The yield for the diagnosis of palpitations is relatively low during event monitoring (67–83%) and Holter monitoring (35–39%) [4, 6–9].”
BackgroundBright, J. M., & Cali, J. V. (2000) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.2000.216.1110 · Cited by 45
Implantable loop recorders in the real world: a study of two Canadian centers
Ibrahim, O., Drew, D., Hayes, C. J., McIntyre, W. F., Seifer, C. M., Hopman, W. M., Glover, B. M., & Baranchuk, A. M. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-017-0294-y · Cited by 44
Karaoğuz, M. R., Yurtseven, E., Aslan, G., Deliormanlı, B. G., Adıgüzel, Ö., Gönen, M., Li, K.-M., & Yılmaz, E. N. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.02.012 · Cited by 40
Current and Emerging Indications for Implantable Cardiac Monitors
Giada, F., Bertaglia, E., Reimers, B., Noventa, D., & Raviele, A. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03411.x · Cited by 39
Hoefman, E., van Weert, H. C., Boer, K. R., Reitsma, J., Koster, R. W., & Bindels, P. J. (2006) · Family Practice · doi:10.1093/fampra/cml065 · Cited by 38
Bolourchi, M., & Batra, A. S. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.12.014 · Cited by 37
Balmelli, N., Naegeli, B., & Bertel, O. (2003) · Clinical Cardiology · doi:10.1002/clc.4960260405 · Cited by 35
Piotrowicz, R., Krzesiński, P., Balsam, P., Piotrowicz, E., Kempa, M., Lewicka, E., Główczyńska, R., Grabowski, M., Kołtowski, Ł., Peller, M., et al. (2021) · Kardiologia Polska · doi:10.33963/kp.15824 · Cited by 35
Clinical validation of a low-power and wearable ECG patch for long term full-disclosure monitoring
Torfs, T., Smeets, C. J. P. P., Geng, D., Berset, T., der Auwera, J. V., Vandervoort, P. M., & Grieten, L. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.08.012 · Cited by 35
Sciaraffia, E., Chen, J., Hocini, M., Larsen, T. B., Potpara, T., & Blomstrom-Lundqvist, C. (2014) · Europace · doi:10.1093/europace/euu222 · Cited by 33
Multi-purpose ECG telemetry system
Marouf, M., Vukomanović, G., Saranovac, L. V., & Bozic, M. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0371-6 · Cited by 33
Park, M. H. K., de Asmundis, C., Chierchia, G., Sarkozy, A., Benatar, A. A., & Brugada, P. (2011) · EP Europace · doi:10.1093/europace/eur159 · Cited by 29
Ambulatory ECG monitoring in the age of smartphones
Sanders, D. J., Ungar, L. D. J., Eskander, M., & Seto, A. H. (2019) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.86a.18123 · Cited by 29
Utility of patient-activated cardiac event recorders in the detection of cardiac arrhythmias
Wu, C.-C., Hsieh, M.-H., Tai, C.-T., Chiang, C.-E., Yu, W.-C., Lin, Y.-K., Tsao, H.-M., Ding, P. Y.-A., & Chen, S.-A. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1023604816368 · Cited by 27
Robust wireless capacitive ECG system with adaptive signal quality and motion artifact reduction
Castro, I. D., Morariu, R., Torfs, T., Hoof, C. A. V., & Puers, R. (2016) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533802 · Cited by 27
Cardiac monitoring for patients with palpitations
Pascual, J. F., Romero, J. C., Pérez‐Rodon, J., Benito, B., Santos‐Ortega, A., Maldonado, J., González, I. F., & Rivas‐Gándara, N. (2021) · World Journal of Cardiology · doi:10.4330/wjc.v13.i11.608 · Cited by 27
Sulfi, S., Balami, D., Sekhri, N., Suliman, A., Kapur, A., Archbold, A., Ranjadayalan, K., & Timmis, A. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2007.00199.x · Cited by 27
Clinical Approach to Patients with Palpitations
Giada, F., & Raviele, A. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2018.02.010 · Cited by 27
Bu, Y., Hassan, M. F. U., & Lai, D. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3001295 · Cited by 26
Hoefman, E., Boer, K. R., van Weert, H. C., Reitsma, J. B., Koster, R. W., & Bindels, P. J. (2007) · Family Practice · doi:10.1093/fampra/cmm056 · Cited by 20
Utility of event loop recorders for the management of arrhythmias in young ambulatory patients
Martinez, T., & Sztajzel, J. M. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2003.11.004 · Cited by 20
Tomson, T. T., & PASSMAN, R. S. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000129 · Cited by 20
Romero, I. (2013) · Cardiology in Review · doi:10.1097/crd.0b013e31828a8294 · Cited by 20
Reed, M. J., Grubb, N. R., Lang, C. C., O’Brien, R., Simpson, K., Padarenga, M., Grant, A., & Tuck, S. (2018) · Trials · doi:10.1186/s13063-018-3098-1 · Cited by 17
External Cardiac Loop Recorders: Functionalities, Diagnostic Efficacy, Challenges and Opportunities
Rajanna, R. R., Sriraam, N., Prakash, V. S. R., Vittal, P. R., Arun, U., & Sahoo, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3055219 · Cited by 17
Sandberg, E. L., Grenne, B. L., Berge, T., Grimsmo, J., Atar, D., Halvorsen, S., Fensli, R. W., & Jortveit, J. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/5230947 · Cited by 15
A mobile ECG monitoring system with context collection
Li, J. P., Berry, D., & Hayes, R. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_292 · Cited by 15
Ocak, T., Erdem, A., Duran, A., Tekelioğlu, Ü. Y., Öztürk, S., Ayhan, S. S., Özlü, M. F., Tosun, M., Koçoğlu, H., & Yazıcı, M. (2013) · Clinics · doi:10.6061/clinics/2013(04)17 · Cited by 14
Lee, Y. K., Park, K. H., Song, Y. D., Youk, T., Nam, J. Y., Song, S. O., Shin, D. Y., & Lee, E. J. (2019) · Cancer Research and Treatment · doi:10.4143/crt.2018.534 · Cited by 13
Quan, K. J. (2019) · Medical Clinics of North America · doi:10.1016/j.mcna.2019.05.005 · Cited by 12
Remote ECG Monitoring by ECG247 Smart Heart Sensor
Jortveit, J., & Fensli, R. W. (2022) · International Journal of Telemedicine and Applications · doi:10.1155/2022/6812889 · Cited by 12
Holter monitoring: are two days better than one?
McClennen, S., ZIMETBAUM, P. J., Ho, K. K. L., & Goldberger, A. L. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01017-1 · Cited by 11
Self-citationStudyInvestigators, T. R. A., Nagashima, K., Okumura, Y., Yokoyama, K., Matsumoto, N., Tachibana, E., Kuronuma, K., Oiwa, K., Matsumoto, M., Kojima, T., et al. (2019) · Heart and Vessels · doi:10.1007/s00380-019-01535-6 · Cited by 10
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.004 · Cited by 11
Palpitations: a proper evaluation and approach to effective medical therapy
Pickett, C. C., & Zimetbaum, P. J. (2005) · Current Cardiology Reports · doi:10.1007/s11886-005-0090-7 · Cited by 9
Self-citationSubcutaneous cardiac rhythm monitors: state of the art review
Nadkarni, A., Devgun, J. K., Jamal, S. M., Bardales, D., Mease, J., Matto, F., Okabe, T., Daoud, E. G., & Afzal, M. R. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1935873 · Cited by 9
Patel, U. K., Malik, P., Patel, N., Patel, P., Mehta, N. N., Urhoghide, E., Aedma, S. K., Chakinala, R. C., Shah, S., & Arumaithurai, K. (2021) · Cureus · doi:10.7759/cureus.12437 · Cited by 8
Epifanio, H. B., Katz, M., Borges, M. A., Corrêa, A. D. G., Cintra, F. D., Grinberg, R. L., Ludovice, A. C., Valdigem, B. P., da Silva, N. J. C., & Fenelon, G. (2014) · Einstein (São Paulo) · doi:10.1590/s1679-45082014ao2939 · Cited by 7
Akça, T., Uysal, F., Bostan, Ö., Genç, A., & Türkmen, H. (2021) · Pediatric Cardiology · doi:10.1007/s00246-021-02705-y · Cited by 7
Krahn, A. D., Renner, S., Klein, G. J., Yee, R. K., Skanes, A. C., & Evans, E. M. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00400.x · Cited by 7
Emergency Management of Palpitations in the Elderly
Jamshed, N., Dubin, J. S., & ELDADAH, Z. A. (2012) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2012.10.003 · Cited by 7
Gula, L. J., Klein, G. J., Zurawska, U., Massel, D. R., Yee, R. K., Skanes, A. C., & Krahn, A. D. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02306.x · Cited by 7
Huisartsen kunnen de kans op hartritmestoornissen vaak niet goed inschatten
Hoefman, E., Boer, K. R., van Weert, H. C. P. M., Reitsma, J. B., Koster, R. W., & Bindels, P. (2008) · Huisarts en Wetenschap · doi:10.1007/bf03086812 · Cited by 6
Steinberg, C., Bennett, M. T., & Krahn, A. D. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_5 · Cited by 6
Optimal duration and predictors of diagnostic utility of patient-activated ambulatory ECG monitoring
Tan, E. S. J., Seow, S., Kojodjojo, P., Singh, D., Yeo, W. T., & Lim, T. W. (2018) · Heart Asia · doi:10.1136/heartasia-2018-011061 · Cited by 6
Clinical experience in extended cardiac monitoring with the SEEQ™ satellite wireless system
Vanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.008 · Cited by 5
Diagnostic value of portable electrocardiogram (Cardiophone) in patients complaining of palpitation
Aizawa, Y., Takatsuki, S., Suenaga, Y., Kimura, T., Nishiyama, N., Fukumoto, K., Tanimoto, Y., Tanimoto, K., Kohsaka, S., Fukuda, Y., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.03.182 · Cited by 5
Holter monitoring in diagnosis of arrhythmias and asequence heart
Целуйко, В. И., & Radchenko, О. (2016) · Medicine of Ukraine · doi:10.37987/1997-9894.2016.5-6(201-2).204729 · Cited by 4
Blücher, S., Kaemmerer, H. M., Lammers, A. E., Brodherr-Heberlein, S., & Hess, J. (2000) · Herz · doi:10.1007/pl00001978 · Cited by 4
Irie, S., & Tada, H. (2023) · International Heart Journal · doi:10.1536/ihj.22-436 · Cited by 3
Evaluation of Patients with Palpitations: Cardiac Event Recorder Versus 48‐hour Holter Monitoring
Makowska, E., Szymot, J., Soszyriska, M., & Kułakowski, P. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00068.x · Cited by 3
Abordaje de las palpitaciones y la taquicardia
Mateo-Martínez, A., Villegas-García, M., & Sánchez‐Martínez, M. (2015) · FMC - Formación Médica Continuada en Atención Primaria · doi:10.1016/j.fmc.2015.03.002 · Cited by 3
Vanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.003 · Cited by 3
Brunetti, N. D., D’Arienzo, G., Tiscia, G., Pellegrino, P. L., Gennaro, L. D., & Biase, M. D. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.055 · Cited by 3
Electrocardiology, N., Kadish, A. H., Buxton, A. E., Winters, W. L., & Boone, A. W. (2001) · Cited by 3
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 3
Monitoring of Atrial Tachyarrhythmias
Mehra, R. (2002) · Cardiac Electrophysiology Review · doi:10.1023/a:1016372823942 · Cited by 3
Arrhythmias in Older People: Focusing on Atrial Fibrillation. Epidemiology and impact on daily Life.
Lindberg, T. (2017) · Lund University Publications (Lund University) · Cited by 3
The single-lead 14-day ECG patch EZYPRO®: a new kid in the block
Dilaveris, P., & Tsioufis, C. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.03.069 · Cited by 3
Características clínicas de pacientes llevados a monitoría externa de eventos
Carvajal, J. J., Clavijo, C., Bautista, L. J., & Mora, G. (2014) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2013.11.001 · Cited by 2
An introduction to ambulatory electrocardiography
Richley, D. (2010) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2010.5.1.46025 · Cited by 2
Evaluation of the Patient with Palpitations and Non-life-threatening Cardiac Arrhythmias
Spratt, K. A., & Michelson, E. L. (2001) · doi:10.1007/978-1-4615-6601-4_8 · Cited by 2
Patientenaktivierte EKD-Aufzeichnung bei Kindern
Hennig, B., Heinke, F., Kinzel, P., Kottkamp, H., Schneider, P., & Häusler, H.-J. (2000) · Monatsschrift Kinderheilkunde · doi:10.1007/s001120050650 · Cited by 2
Poposka, L., Vavlukis, M., Pejkov, H., & Gušev, M. (2021) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2021.4960 · Cited by 2
Iliev, I. T., Jekova, I. I., Tabakov, S. D., Koshtikova, K. G., Runev, N. M., & Manov, Е. (2022) · Lecture notes in networks and systems · doi:10.1007/978-3-030-96638-6_33 · Cited by 2
COST-EFFECTIVENESS OF STRESS-ECHOCARDIOGRAPHY
Marine, J. E., Freedberg, K. A., & Davidoff, R. (1999) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70098-9 · Cited by 2
肺静脈隔離術後における心房細動再発と自覚症状:携帯型心電計による検討
Ashihara, T., Nakazawa, Y., Yao, T., Jo, H., Ito, H., Sugimoto, Y., Ito, M., & Horie, M. (2007) · Japanese Journal of Electrocardiology · doi:10.5105/jse.27.307 · Cited by 2
La gestione del paziente con palpitazioni
Giada, F., Inama, G., Bertaglia, M., Pedrinazzi, C., Gulizia, M. M., Ricci, R. P., & Raviele, A. (2010) · Giornale Ialiano di Cardiologia · doi:10.1714/568.6749 · Cited by 2
Metadata
- Authors
- Zimetbaum, P. J., Kim, K. Y., Josephson, M. E., Goldberger, A. L., & Cohen, D. J.
- Affiliations
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Zimetbaum, Peter J.
- ORCID
- Zimetbaum, Peter J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1998-06-01
- Volume
- 128
- Issue
- 11
- Pages
- 890-895
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1967172540
- Semantic Scholar
- b44b7bcb7010ab254a947d46614a6734e6a2eadb
- Cited by
- 133
- References
- 7
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 6 · 2021: 12 · 2020: 3 · 2019: 6 · 2018: 5 · 2017: 7 · 2016: 4 · 2015: 4 · 2014: 9 · 2013: 8 · 2012: 5
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- palpitations, diagnostic yield, monitoring duration, cost-effectiveness, event data recorders, arrhythmia diagnosis, incremental cost-effectiveness ratio
- MeSH terms
- Adult, Aged, Arrhythmias, Cardiac, Cost-Benefit Analysis, Costs and Cost Analysis, Female, Humans, Male, Middle Aged, Prospective Studies, Time Factors, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.