Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 1,002

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism

Wells, Philip S., Ginsberg, Jeffrey S., Anderson, David R., Kearon, Clive, Gent, Michael, Turpie, Alexander G., Bormanis, Janis, Weitz, Jeffrey, Chamberlain, Michael, Bowie, Dennis, Barnes, David, Hirsh, Jack · 1998 · Annals of Internal Medicine

Abstract

BACKGROUND: The low specificity of ventilation-perfusion lung scanning complicates the management of patients with suspected pulmonary embolism. OBJECTIVE: To determine the safety of a clinical model for patients with suspected pulmonary embolism. DESIGN: Prospective cohort study. SETTING: Five tertiary care hospitals. PATIENTS: 1239 inpatients and outpatients with suspected pulmonary embolism. INTERVENTIONS: A clinical model categorized pretest probability of pulmonary embolism as low, moderate, or high, and ventilation-perfusion scanning and bilateral deep venous ultrasonography were done. Testing by serial ultrasonography, venography, or angiography depended on pretest probability and lung scans. MEASUREMENTS: Patients were considered positive for pulmonary embolism if they had an abnormal pulmonary angiogram, abnormal ultrasonogram or venogram, high-probability ventilation-perfusion scan plus moderate or high pretest probability, or venous thromboembolic event during the 3-month follow-up. All other patients were considered negative for pulmonary embolism. Rates of pulmonary embolism during follow-up in patients who had a normal lung scan and those with a non-high-probability scan and normal serial ultrasonogram were compared. RESULTS: Pretest probability was low in 734 patients (3.4% with pulmonary embolism), moderate in 403 (27.8% with pulmonary embolism), and high in 102 (78.4% with pulmonary embolism). Three of the 665 patients (0.5% [95% CI, 0.1% to 1.3%]) with low or moderate pretest probability and a non-high-probability scan who were considered negative for pulmonary embolism had pulmonary embolism or deep venous thrombosis during 90-day follow-up; this rate did not differ from that in patients with a normal scan (0.6% [CI, 0.1% to 1.8%]; P > 0.2). CONCLUSION: Management of patients with suspected pulmonary embolism on the basis of pretest probability and results of ventilation-perfusion scanning is safe.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-129-12-199812150-00002

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 1,002

Metadata

Authors
Wells, P. S., Ginsberg, J. S., Anderson, D. R., Kearon, C., Gent, M., Turpie, A. G., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., Barnes, D., & Hirsh, J.
Venue
Annals of Internal Medicine
Published
1998-12-15
Volume
129
Issue
12
Pages
997-1005
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2163723714
Cited by
1,002
References
13
FWCI
21.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism. https://app.cochat.ai/papers/10.7326/0003-4819-129-12-199812150-00002
The paper
Wells, P. S., Ginsberg, J. S., Anderson, D. R., Kearon, C., Gent, M., Turpie, A. G., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., Barnes, D., & Hirsh, J. (1998). Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-129-12-199812150-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.