The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism
Abstract
BACKGROUND: The low specificity of ventilation-perfusion lung scanning complicates the management of patients with suspected pulmonary embolism. OBJECTIVE: To determine the safety of a clinical model for patients with suspected pulmonary embolism. DESIGN: Prospective cohort study. SETTING: Five tertiary care hospitals. PATIENTS: 1239 inpatients and outpatients with suspected pulmonary embolism. INTERVENTIONS: A clinical model categorized pretest probability of pulmonary embolism as low, moderate, or high, and ventilation-perfusion scanning and bilateral deep venous ultrasonography were done. Testing by serial ultrasonography, venography, or angiography depended on pretest probability and lung scans. MEASUREMENTS: Patients were considered positive for pulmonary embolism if they had an abnormal pulmonary angiogram, abnormal ultrasonogram or venogram, high-probability ventilation-perfusion scan plus moderate or high pretest probability, or venous thromboembolic event during the 3-month follow-up. All other patients were considered negative for pulmonary embolism. Rates of pulmonary embolism during follow-up in patients who had a normal lung scan and those with a non-high-probability scan and normal serial ultrasonogram were compared. RESULTS: Pretest probability was low in 734 patients (3.4% with pulmonary embolism), moderate in 403 (27.8% with pulmonary embolism), and high in 102 (78.4% with pulmonary embolism). Three of the 665 patients (0.5% [95% CI, 0.1% to 1.3%]) with low or moderate pretest probability and a non-high-probability scan who were considered negative for pulmonary embolism had pulmonary embolism or deep venous thrombosis during 90-day follow-up; this rate did not differ from that in patients with a normal scan (0.6% [CI, 0.1% to 1.8%]; P > 0.2). CONCLUSION: Management of patients with suspected pulmonary embolism on the basis of pretest probability and results of ventilation-perfusion scanning is safe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of clinical assessment of deep-vein thrombosis
Wells, P., Hirsh, J., Anderson, D., Lensing, A. A., Foster, G., Kearon, C., Weitz, J., D'Ovidio, R., Cogo, A., Prandoni, P., et al. (1995) · The Lancet · doi:10.1016/s0140-6736(95)92535-x · Cited by 798
Self-citationRoentgen Diagnosis of Venous Thrombosis in the Leg
Rabinov, K. (1972) · Archives of Surgery · doi:10.1001/archsurg.1972.04180020014004 · Cited by 740
Complications and validity of pulmonary angiography in acute pulmonary embolism.
Stein, P. D., Athanasoulis, C., Alavi, A., Greenspan, R. H., Hales, C. A., Saltzman, H. A., Vreim, C. E., Terrin, M. L., & Weg, J. G. (1992) · Circulation · doi:10.1161/01.cir.85.2.462 · Cited by 669
HULL, R. D., HIRSH, J., CARTER, C. J., JAY, R. M., DODD, P. E., OCKELFORD, P. A., COATES, G., GILL, G. J., TURPIE, A. G., DOYLE, D. J., et al. (1983) · Annals of Internal Medicine · doi:10.7326/0003-4819-98-6-891 · Cited by 645
Self-citationDunnett, C. W., & Gent, M. (1977) · Biometrics · doi:10.2307/2529457 · Cited by 389
Self-citationUnexpected High Prevalence of Silent Pulmonary Embolism in Patients with Deep Venous Thrombosis
Huisman, M. V., Büller, H. R., ten Cate, J. W., van Royen, E. A., Vreeken, J., Kersten, M.-J., & Bakx, R. (1989) · Chest · doi:10.1378/chest.95.3.498 · Cited by 311
Turkstra, F., Kuijer, P. M. M., van Beek, E. J. R., Brandjes, D. P. M., ten Cate, J. W., & Buller, H. R. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-10-199705150-00005 · Cited by 298
GOTTSCHALK, A. R., Sostman, H. D., Coleman, R. E., Juni, J. E., Thrall, J. H., McKusick, K. A., FROELICH, J. W., & Alavi, A. A. (1993) · PubMed · Cited by 286
Perrier, A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.156.5.531 · Cited by 267
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
“83,94,135,203 The proportion of diagnostic V/Q scans is higher in patients with a normal chest X-ray, and this supports the recommendation to use V/Q scan as the first-line imaging test for PE in younger patients.”
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Multidetector Computed Tomography for Acute Pulmonary Embolism
Stein, P. D., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Leeper, K. V., Popovich, J., Quinn, D. A., Sos, T. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052367 · Cited by 1,660
Anderson, D., Rodger, M., Ginsberg, J., Kearon, C., Gent, M., Turpie, A., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., et al. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613830 · Cited by 1,659
Self-citation
Metadata
- Authors
- Wells, P. S., Ginsberg, J. S., Anderson, D. R., Kearon, C., Gent, M., Turpie, A. G., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., Barnes, D., & Hirsh, J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1998-12-15
- Volume
- 129
- Issue
- 12
- Pages
- 997-1005
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2163723714
- Cited by
- 1,002
- References
- 13
- FWCI
- 21.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism. https://app.cochat.ai/papers/10.7326/0003-4819-129-12-199812150-00002
- The paper
- Wells, P. S., Ginsberg, J. S., Anderson, D. R., Kearon, C., Gent, M., Turpie, A. G., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., Barnes, D., & Hirsh, J. (1998). Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-129-12-199812150-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.