The DOI matches its Crossref record; 64 of the 65 references it cites were found in a registry or an index.
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Abstract
PURPOSE: To evaluate the efficacy of various ambulatory electrocardiographic monitors for the diagnosis of arrhythmia-related disorders and to provide recommendations for their use in clinical practice. DATA SOURCES: Studies published since 1988 were identified through search of the MEDLINE database. STUDY SELECTION: Studies that met methodologic criteria for minimal bias and had clinical relevance were selected. DATA EXTRACTION: Descriptive and analytic data from each study. DATA SYNTHESIS: Ambulatory electrocardiographic monitors, specifically transtelephonic continuous-loop event recorders, are highly effective for establishing a diagnosis in patients with palpitations but are less effective for establishing a diagnosis in patients with syncope. Clinicians may use these devices to monitor for nonsustained ventricular tachycardia in patients at potentially high risk for sudden arrhythmic death; however, few data are available to support this practice. Ambulatory monitors are useful for assessment of the safety and efficacy of antiarrhythmic medications and the recurrence of symptomatic supraventricular arrhythmias. New ambulatory arrhythmia monitoring devices are being developed that may facilitate outpatient management of chronic cardiac disease. CONCLUSIONS: Ambulatory electrocardiographic monitors, particularly transtelephonic continuous-loop event recorders, aid in the diagnosis of symptomatic arrhythmias. These devices are also useful for monitoring the effectiveness and safety of antiarrhythmic medications. Guidelines are lacking for use of these devices to assess prognosis in patients at potential risk for sudden arrhythmic death.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In patients with palpitations of unknown origin, Holter monitoring has displayed a rather low sensitivity value (33-35%).81”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [81]
Citations
Cites
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Cohn, J. N., Johnson, G., Ziesche, S., Cobb, F., Francis, G., Tristani, F., Smith, R., Dunkman, W. B., Loeb, H., Wong, M., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250502 · Cited by 2,833
Risk Stratification and Survival after Myocardial Infarction
The Multicenter Postinfarction Research Group (1983) · New England Journal of Medicine · doi:10.1056/nejm198308113090602 · Cited by 1,599
Nolan, J., Batin, P. D., Andrews, R., Lindsay, S. J., Brooksby, P., Mullen, M., Baig, W., Flapan, A. D., Cowley, A., Prescott, R. J., et al. (1998) · Circulation · doi:10.1161/01.cir.98.15.1510 · Cited by 1,179
Randomised trial of low-dose amiodarone in severe congestive heart failure
Doval, H., Nul, D. R., Grancelli, H., Perrone, S. V., Bortman, G., & Curiel, R. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91895-3 · Cited by 913
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Wigle, E. D., Rakowski, H., Kimball, B. P., & Williams, W. G. (1995) · Circulation · doi:10.1161/01.cir.92.7.1680 · Cited by 775
Management of Patients With Atrial Fibrillation
Prystowsky, E. N., Benson, D. W., Fuster, V., Hart, R. G., Kay, G. N., Myerburg, R. J., Naccarelli, G. V., & Wyse, D. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1262 · Cited by 638
Antiarrhythmic drug therapy and cardiac mortality in atrial fibrillation
Flaker, G. C., Blackshear, J. L., McBride, R., Kronmal, R. A., Halperin, J. L., & Hart, R. G. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90003-6 · Cited by 633
Research works printed but not linked: 2
- Kus T, 1995, Can J Cardiol, 11, 891
- Maron BJ, 1992, Circulation, 85, I57
Cited by
Sorted by citations
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,772
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,496
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 748
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 550
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Detecting Vital Signs with Wearable Wireless Sensors
Yilmaz, T., Foster, R., & Hao, Y. (2010) · Sensors · doi:10.3390/s101210837 · Cited by 341
The Evaluation and Management of Bradycardia
Mangrum, J. M., & DiMarco, J. P. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003093421006 · Cited by 279
Seet, R. C. S., Friedman, P. A., & Rabinstein, A. A. (2011) · Circulation · doi:10.1161/circulationaha.111.029801 · Cited by 274
Diagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258
Self-citationA new pacemaker algorithm for the treatment of atrial fibrillation
Carlson, M. D., Ip, J. E., Messenger, J. C., Beau, S. L., Kalbfleisch, S. J., Gervais, P., CAMERON, D. A., Duran, A., Val-Mejias, J. E., Mackall, J. A., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00780-0 · Cited by 237
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
Self-citationRecurrent Unexplained Palpitations (RUP) Study
Giada, F., Gulizia, M., Francese, M., Croci, F., Santangelo, L., Santomauro, M., Occhetta, E., Menozzi, C., & Raviele, A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.036 · Cited by 158
Raviele, A., Giada, F., Bergfeldt, L., Blanc, J. J., Blomstrom-Lundqvist, C., Mont, L., Morgan, J. M., Raatikainen, M. J. P., Steinbeck, G., Viskin, S., et al. (2011) · Europace · doi:10.1093/europace/eur130 · Cited by 149
Reiffel, J. A., Schwarzberg, R., & Murry, M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.01.025 · Cited by 131
Gharibans, A. A., Smarr, B. L., Kunkel, D. C., Kriegsfeld, L. J., Mousa, H. M., & Coleman, T. P. (2018) · Scientific Reports · doi:10.1038/s41598-018-23302-9 · Cited by 100
Kim, A. S., Fullerton, H. J., & Johnston, S. C. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.06.559 · Cited by 95
Diagnostic approach to palpitations.
Abbott, A. V. (2005) · PubMed · Cited by 83
Kaleschke, G., Hoffmann, B., Drewitz, I., Steinbeck, G., Naebauer, M., Goette, A., Breithardt, G., & Kirchhof, P. (2009) · Europace · doi:10.1093/europace/eup262 · Cited by 81
SCHUCHERT, A., MAAS, R., KRETZSCHMAR, C., BEHRENS, G., KRATZMANN, I., & MEINERTZ, T. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00277.x · Cited by 62
Diretrizes para Avaliação e Tratamento de Pacientes com Arritmias Cardíacas
Feitosa, G. S., Nicolau, J. C., Lorga, A. M., Filho, A. L., d’Ávila, A., Rassi, A., de Paola, Â. A. V., Pedrosa, A., da Costa, Á. B., Péres, A. K., et al. (2002) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2002001900001 · Cited by 71
OLSON, J. A., FOUTS, A. M., PADANILAM, B. J., & PRYSTOWSKY, E. N. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00779.x · Cited by 59
Reed, M. J., Grubb, N. R., Lang, C. C., O'Brien, R., Simpson, K., Padarenga, M., Grant, A., Tuck, S., Keating, L., Coffey, F., et al. (2019) · EClinicalMedicine · doi:10.1016/j.eclinm.2019.02.005 · Cited by 57
Long-term continuous external electrocardiographic recording: a review
Enseleit, F., & Duru, F. (2006) · EP Europace · doi:10.1093/europace/euj054 · Cited by 60
Liu, Y., & PECHT, M. G. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260006 · Cited by 49
Diagnostic Evaluation and Management of Patients with Syncope
Schnipper, J. L., & Kapoor, W. N. (2001) · Medical Clinics of North America · doi:10.1016/s0025-7125(05)70321-7 · Cited by 49
Summerton, N., Mann, S., Rigby, A., Petkar, S., & Dhawan, J. (2001) · Family Practice · doi:10.1093/fampra/18.4.383 · Cited by 49
Hoefman, E., van Weert, H. C. P. M., Reitsma, J. B., Koster, R. W., & Bindels, P. (2005) · Family Practice · doi:10.1093/fampra/cmi048 · Cited by 45
Scalvini, S., Zanelli, E., Martinelli, G., Baratti, D., Giordano, A., & Glisenti, F. (2005) · Journal of Telemedicine and Telecare · doi:10.1258/1357633054461930 · Cited by 45
Scherr, D., Dalal, D., Henrikson, C. A., Spragg, D. D., Berger, R. D., Calkins, H., & Cheng, A. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9251-0 · Cited by 45
Bell, C. M., Kapral, M. K., & The Canadian Task Force on Preventive Health Care (2000) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100051933 · Cited by 42
Clinical validation of a low-power and wearable ECG patch for long term full-disclosure monitoring
Torfs, T., Smeets, C. J. P. P., Geng, D., Berset, T., der Auwera, J. V., Vandervoort, P. M., & Grieten, L. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.08.012 · Cited by 33
The Diagnostic Significance of the Holter Monitoring in the Evaluation of Palpitation
Paudel, B., & Paudel, K. (2013) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2013/4923.2802 · Cited by 32
Utility of patient-activated cardiac event recorders in the detection of cardiac arrhythmias
Wu, C.-C., Hsieh, M.-H., Tai, C.-T., Chiang, C.-E., Yu, W.-C., Lin, Y.-K., Tsao, H.-M., Ding, P. Y.-A., & Chen, S.-A. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1023604816368 · Cited by 27
Validation of a smartphone‐based event recorder for arrhythmia detection
Narasimha, D., Hanna, N., Beck, H., Chaskes, M. J., Glover, R., Gatewood, R. P., Bourji, M., Gudleski, G. D., Danzer, S., & Curtis, A. B. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13317 · Cited by 27
Sulfi, S., Balami, D., Sekhri, N., Suliman, A., Kapur, A., Archbold, A., Ranjadayalan, K., & Timmis, A. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2007.00199.x · Cited by 25
Lawless, C. E., & Briner, W. W. (2008) · Sports Medicine · doi:10.2165/00007256-200838080-00006 · Cited by 25
2020 Clinical practice guidelines for Supraventricular tachycardia in adults
Bokeria, L. A., Golukhova, E. Z., Popov, S. V., Artyukhina, Е. А., Базаев, В. А., Batalov, R. E., Bokeria, O. L., Vygovsky, A. B., Gilyarov, M. Y., Sp, G., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4484 · Cited by 23
Clinical Approach to Patients with Palpitations
Giada, F., & Raviele, A. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2018.02.010 · Cited by 21
Kurniawan, J. F., Tjhia, B., Wu, V. M., Shin, A. J., Sit, N. L. J., Pham, T. V., Nguyen, A., Li, C., Kumar, R., Aguilar‐Rivera, M., et al. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202001229 · Cited by 20
Utility of event loop recorders for the management of arrhythmias in young ambulatory patients
Martinez, T., & Sztajzel, J. M. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2003.11.004 · Cited by 19
Reed, M. J., Grubb, N. R., Lang, C. C., O’Brien, R., Simpson, K., Padarenga, M., Grant, A., & Tuck, S. (2018) · Trials · doi:10.1186/s13063-018-3098-1 · Cited by 17
Miniaturized Human Insertable Cardiac Monitoring System with Wireless Power Transmission Technique
Lee, J. (2015) · Journal of Sensors · doi:10.1155/2016/5374574 · Cited by 17
Romero, I. (2013) · Cardiology in Review · doi:10.1097/crd.0b013e31828a8294 · Cited by 16
Reasons for Hospitalization Among Emergency Department Patients With Syncope
Cook, O., Mukarram, M. A., Rahman, O. M., Kim, S., Arcot, K., Thavorn, K., Taljaard, M., Sivilotti, M. L. A., Rowe, B. H., & Thiruganasambandamoorthy, V. (2016) · Academic Emergency Medicine · doi:10.1111/acem.13053 · Cited by 14
Positionspapier Telemonitoring
Arbeitsgruppe 33/Telemonitoring in der Deutschen Gesellschaft für Kardiologie, H. U. K. E. V. (. U. A. M., Helms, T. M., Stockburger, M. A., Koehler, F., Leonhardt, V., Muller, A. M., Rybak, K., Sack, S., Schwab, J. O., Zugck, C., et al. (2019) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-019-0630-2 · Cited by 13
Computer aided diagnosis sensor integrated outdoor shirts for real time heart disease monitoring
Park, J. A., Han, H. S., Heo, J.-C., & Lee, J. (2017) · Computer Assisted Surgery · doi:10.1080/24699322.2017.1389396 · Cited by 14
A mobile ECG monitoring system with context collection
Li, J. P., Berry, D., & Hayes, R. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_292 · Cited by 14
2025 Clinical practice guidelines for Supraventricular tachycardias
Popov, S. V., Davtyan, K. V., Shubik, Y. V., Artyukhina, Е. А., Базаев, В. А., Batalov, R. E., Bokeria, L. A., Bubnova, M. G., Vygovsky, A. B., Sp, G., et al. (2025) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2025-6448 · Cited by 12
Newham, W. G., & Tayebjee, M. H. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1514 · Cited by 12
Quan, K. J. (2019) · Medical Clinics of North America · doi:10.1016/j.mcna.2019.05.005 · Cited by 11
Feasibility study of practical vital sign detection using millimeter-wave radios
Wang, W., Jia, Z., Xu, C., Luo, G., Zhang, D., An, N., & Zhang, Y. (2021) · CCF Transactions on Pervasive Computing and Interaction · doi:10.1007/s42486-021-00080-4 · Cited by 11
PocketECG: a new continuous and real-time ambulatory arrhythmia diagnostic method.
Dziubinski, M. J. (2011) · PubMed · Cited by 10
Schuchert, A., Behrens, G., & Meinertz, T. (2002) · Zeitschrift für Kardiologie · doi:10.1007/s392-002-8373-4 · Cited by 10
Monitoring devices for falls and syncope
Seifer, C. M., & Parry, S. W. (2002) · Clinics in Geriatric Medicine · doi:10.1016/s0749-0690(02)00011-3 · Cited by 9
Holter Monitoring vs Tilt Testing in the Investigation of Suspected Vasovagal Syncope
Fitchet, A., Stirling, M. L., BURNETT, G., Goode, G., Garratt, C. J., & Fitzpatrick, A. P. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00221.x · Cited by 8
Tung, J. Y. (2010) · TSpace (University of Toronto) · Cited by 9
Developments in Ambulatory Electrocardiography
Eveloy, V. C., Liu, Y., & PECHT, M. G. (2006) · Biomedical Instrumentation & Technology · doi:10.2345/i0899-8205-40-3-238.1 · Cited by 8
Akça, T., Uysal, F., Bostan, Ö., Genç, A., & Türkmen, H. (2021) · Pediatric Cardiology · doi:10.1007/s00246-021-02705-y · Cited by 7
Henry, L. L., & Ad, N. (2010) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0b013e3181ee5b42 · Cited by 6
Iris features-based heart disease diagnosis by computer vision
Nguchu, B. A., & Li, L. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2281954 · Cited by 6
Emergency Management of Palpitations in the Elderly
Jamshed, N., Dubin, J. S., & ELDADAH, Z. A. (2012) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2012.10.003 · Cited by 6
Diagnostic value of portable electrocardiogram (Cardiophone) in patients complaining of palpitation
Aizawa, Y., Takatsuki, S., Suenaga, Y., Kimura, T., Nishiyama, N., Fukumoto, K., Tanimoto, Y., Tanimoto, K., Kohsaka, S., Fukuda, Y., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.03.182 · Cited by 5
The implantable loop recorder in children: searching for indications
Pass, R. H., & Liberman, L. (2008) · Heart · doi:10.1136/hrt.2007.126276 · Cited by 5
Vassilikos, V. P., Vogas, V., Giannakoulas, G. A., Mantziari, L., Lekka, I., Dimitrakopoulos, K., Paraskevaidis, S., Konias, S., Maglaveras, N., Chouvarda, I., et al. (2010) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2010.0018 · Cited by 4
Александровна, М. А., & Николаевна, Н. Н. (2012) · I P Pavlov Russian Medical Biological Herald · doi:10.17816/pavlovj2012394-99 · Cited by 4
Application of outpatient cardiac testing among emergency department patients with syncope
Cook, O., Mukarram, M. A., Kim, S.-M., Arcot, K., Nemnom, M., Taljaard, M., Sivilotti, M. L. A., Rowe, B. H., & Thiruganasambandamoorthy, V. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2017-207081 · Cited by 4
Park, E.-B., Heo, J.-C., & Lee, J. (2018) · Bio-Medical Materials and Engineering · doi:10.3233/bme-181010 · Cited by 4
Telemonitoring bei Herz-Kreislauf-Erkrankungen in Deutschland
Helms, T. M., Zugck, C., Pelleter, J. T., Ronneberger, D. L., & Korb, H. (2007) · Herz · doi:10.1007/s00059-007-3050-8 · Cited by 4
NHG-Standaard Atriumfibrilleren
Boode, B. S. P., Heeringa, J., Konings, K., Rutten, F., den Berg, P. V., Zwietering, P. J., van Lieshout, J., & Opstelten, W. (2011) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-8279-8_18 · Cited by 4
Hoefman, E., van Weert, H., Reitsma, J. B., Koster, R. W., & Bindels, P. (2005) · Huisarts en Wetenschap · doi:10.1007/bf03084157 · Cited by 4
Sistema de Tele-Monitoreo Inalámbrico de Eventos Cardiacos para Seguimiento de Arritmias
Osorno, J. J. B., Sáenz, J. F., & Amaya, A. A. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-74471-9_220 · Cited by 3
Olshansky, B. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-35868-2.00028-1 · Cited by 3
Discovering the cause of syncope
Hauer, K. E. (2003) · Postgraduate Medicine · doi:10.3810/pgm.2003.01.1356 · Cited by 2
Brunetti, N. D., D’Arienzo, G., Tiscia, G., Pellegrino, P. L., Gennaro, L. D., & Biase, M. D. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.055 · Cited by 2
Güvenç, T. S., Güvenç, R. Ç., Velibey, Y., Tanık, V. O., Öz, D., & Eren, M. (2016) · Medical Hypotheses · doi:10.1016/j.mehy.2016.05.001 · Cited by 2
Conduction Disturbances and Cardiac Pacemakers
Knight, J., & Sarko, J. A. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1367-1.00080-x · Cited by 2
Syncope: Approach to diagnosis
Anil, O. (2016) · Journal of Clinical and Preventive Cardiology · doi:10.4103/2250-3528.191099 · Cited by 2
Vodička, S., & Zelko, E. (2022) · Micromachines · doi:10.3390/mi13081176 · Cited by 2
Novel use of an “insertable” loop recorder
Gimbel, J. (2003) · Heart · doi:10.1136/heart.89.6.e18 · Cited by 2
Ambulatory Electrocardiography
Gionfriddo, W. J., Laidlaw, D. W., & Estes, N. A. M. (2022) · Springer eBooks · doi:10.1007/978-3-030-95259-4_20 · Cited by 2
Diagnosis and Management of Syncope
Karabin, B. L., & Grubb, B. P. (2011) · Wiley eBooks · doi:10.1002/9781118788967.ch16 · Cited by 2
Garg, S., Saha, A., & Clark, A. L. (2006) · Clinical Medicine · doi:10.7861/clinmedicine.6-6-586 · Cited by 2
Doku, A., Ndanu, T. A., Asiamah-Asare, B. K. Y., Antwi‐Boasiako, C., & Kpodonu, J. (2018) · Ghana Medical Journal · doi:10.4314/gmj.v52i4.7 · Cited by 1
Arritmias cardiacas en Urgencias
Gil, A., Herranz, J. F., González, J. A. N., & Lillo, J. A. A. (2011) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/s0304-5412(11)70191-3 · Cited by 1
Long-term Arrhythmia Monitoring in Cryptogenic Stroke: Who, How, and for How Long?
Montalvo, M., Ali, R., Silver, B., & Khan, M. (2016) · The Open Cardiovascular Medicine Journal · doi:10.2174/1874192401610010089 · Cited by 1
Holter monitoring in diagnosis of arrhythmias and asequence heart
Целуйко, В. И., & Radchenko, О. (2016) · Medicine of Ukraine · doi:10.37987/1997-9894.2016.5-6(201-2).204729 · Cited by 1
Köker, S. A., Demirağ, B., Meşe, T., Yılmazer, M. M., Oymak, Y., Özdemir, R., Karapınar, T. H., İnce, D., & Vergin, R. C. (2021) · Turkish Journal of Pediatric Disease · doi:10.12956/tchd.826263 · Cited by 1
van Weert, H. C. P. M. (2013) · Bijblijven · doi:10.1007/s12414-013-0075-1 · Cited by 1
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 1
Foster, R., Yilmaz, T., Munoz, M. O., & Hao, Y. (2012) · Springer series on chemical sensors and biosensors · doi:10.1007/5346_2012_28 · Cited by 1
Александровна, М. А., & Николаевна, Н. Н. (2012) · I P Pavlov Russian Medical Biological Herald · doi:10.17816/pavlovj20121138-143 · Cited by 1
Ismail, S. M. (2019) · Journal of Evolution of Medical and Dental Sciences · doi:10.14260/jemds/2019/409 · Cited by 1
Remote Heart Rhythm Monitoring
Gomes, J. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-45066-3_35 · Cited by 1
Lucassen, W. A. M., Himmelreich, J. C. L., Harskamp, R. E., & Selder, J. L. (2021) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2620-4_30 · Cited by 1
Supporting Self-Reflection in Everyday Life
Sanches, P. (2008) · doi:10.13140/2.1.2219.6809 · Cited by 1
Mori, N., Hara, M., Miyake, F., Sato, C., Murayama, M., Tamamura, K., Kaneko, M., & Sirakawa, O. (2000) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.64.583 · Cited by 1
Fahey, T. P., & Schroeder, K. (2004) · Europe PMC (PubMed Central) · Cited by 1
Ambulatory Electrocardiography, Transient Event Monitors, and Continuous Loop Recorders
Kreeger, R. W., Brooks, J., & Movahed, A. (2008) · Springer eBooks · doi:10.1007/978-3-540-78674-0_9
Metadata
- Authors
- Zimetbaum, P. J., & Josephson, M. E.
- Affiliations
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Zimetbaum, Peter J.
- ORCID
- Zimetbaum, Peter J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1999-05-18
- Volume
- 130
- Issue
- 10
- Pages
- 848-856
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2066069714
- Cited by
- 139
- References
- 65
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 1 · 2022: 4 · 2021: 6 · 2020: 4 · 2019: 5 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 1 · 2014: 2 · 2013: 7 · 2012: 8
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- Holter monitoring, arrhythmia diagnosis, palpitations, syncope, non-sustained ventricular tachycardia, sudden arrhythmic death, supraventricular arrhythmias, general practice
- MeSH terms
- Algorithms, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Heart Diseases, Humans, Risk Factors, Syncope, Medical Laboratory Science, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review