Magnetic Resonance Cholangiopancreatography: A Meta-Analysis of Test Performance in Suspected Biliary Disease

Romagnuolo, Joseph, Bardou, Marc, Rahme, Elham, Joseph, Lawrence, Reinhold, Caroline, Barkun, Alan N. · 2003 · Annals of Internal Medicine

Abstract

BACKGROUND: Magnetic resonance cholangiopancreatography (MRCP) is one of many newer noninvasive tests that can image the biliary tree. PURPOSE: To precisely estimate the overall sensitivity and specificity of MRCP in suspected biliary obstruction and to evaluate clinically important subgroups. DATA SOURCES: MEDLINE search (January 1987 to March 2003) for studies in English or French, bibliographies, and subject matter experts. STUDY SELECTION: Studies were included if they allowed construction of 2x2 contingency tables of MRCP compared with a reasonable gold standard for at least 1 of the following: the presence, level, or cause of biliary obstruction. DATA EXTRACTION: Two independent observers graded study quality, which included consecutive enrollment, blinding, use of a single (versus composite) gold standard, and nonselective use of the gold standard. Logistic regression was used to examine the influence of publication year, quality score, proportion of patients having a "direct" gold standard, and clinical context on diagnostic performance. DATA SYNTHESIS: Of 498 studies identified, 67 were included (4711 patients). Mixed-effect models were used to estimate the sensitivity and specificity, and quantitative receiver-operating characteristic analysis was performed. Magnetic resonance cholangiopancreatography had a high overall pooled sensitivity (95% [+/-1.96 SD: spread of SD, 75% to 99%]) and specificity (97% [spread of SD, 86% to 99%]). The procedure was less sensitive for stones (92%; odds ratio, 0.51 [CI, 0.35 to 0.75]) and malignant conditions (88%; odds ratio, 0.28 [CI, 0.18 to 0.44]) than for the presence of obstruction. In addition, diagnostic performance was higher in studies that were larger, did not use consecutive enrollment, and did not use gold standard assessment for some patients. CONCLUSIONS: Magentic resonance cholangiopancreatography is a noninvasive imaging test with excellent overall sensitivity and specificity for demonstrating the level and presence of biliary obstruction; however, it seems less sensitive for detecting stones or differentiating malignant from benign obstruction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-139-7-200310070-00006

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 61 references

Cited by

See all 445

Metadata

Authors
Romagnuolo, J., Bardou, M., Rahme, E., Joseph, L., Reinhold, C., & Barkun, A. N.
Venue
Annals of Internal Medicine
Published
2003-10-07
Volume
139
Issue
7
Pages
547-557
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2073256621
Cited by
445
References
61
FWCI
12.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic Resonance Cholangiopancreatography: A Meta-Analysis of Test Performance in Suspected Biliary Disease. https://app.cochat.ai/papers/10.7326/0003-4819-139-7-200310070-00006
The paper
Romagnuolo, J., Bardou, M., Rahme, E., Joseph, L., Reinhold, C., & Barkun, A. N. (2003). Magnetic Resonance Cholangiopancreatography: A Meta-Analysis of Test Performance in Suspected Biliary Disease. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-139-7-200310070-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.