d-Dimer for the Exclusion of Acute Venous Thrombosis and Pulmonary Embolism: A Systematic Review
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Despite extensive literature, the diagnostic role of d-dimer for deep venous thrombosis (DVT) or pulmonary embolism (PE) remains unclear, reflecting multiple d-dimer assays and concerns about differing sensitivities and variability. PURPOSE: To systematically review trials that assessed sensitivity, specificity, likelihood ratios, and variability among d-dimer assays. DATA SOURCES: Studies in all languages were identified by searching PubMed from 1983 to January 2003 and EMBASE from 1988 to January 2003. STUDY SELECTION: The researchers selected prospective studies that compared d-dimer with a reference standard. Studies of high methodologic quality were included in the primary analyses; sensitivity analysis included additional weaker studies. DATA EXTRACTION: Two authors collected data on study-level factors: d-dimer assay used, cutoff value, and whether patients had suspected DVT or PE. DATA SYNTHESIS: For DVT, the enzyme-linked immunosorbent assay (ELISA) and quantitative rapid ELISA dominate the rank order for these values: sensitivity, 0.96 (95% confidence limit [CL], 0.91 to 1.00), and negative likelihood ratio, 0.12 (CL, 0.04 to 0.33); and sensitivity, 0.96 (CL, 0.90 to 1.00), and negative likelihood ratio, 0.09 (CL, 0.02 to 0.41), respectively. For PE, the ELISA and quantitative rapid ELISA also dominate the rank order for these values: sensitivity, 0.95 (CL, 0.85 to 1.00), and negative likelihood ratio, 0.13 (CL, 0.03 to 0.58); and sensitivity, 0.95 (CL, 0.83 to 1.00), and negative likelihood ratio, 0.13 (CL, 0.02 to 0.84), respectively. The ELISA and quantitative rapid ELISA have negative likelihood ratios that yield a high certainty for excluding DVT or PE. The positive likelihood values, which are in the general range of 1.5 to 2.5, do not greatly increase the certainty of diagnosis. Sensitivity analyses do not affect these findings. LIMITATIONS: Although many studies evaluated multiple d-dimer assays, findings are based largely on indirect comparisons of test performance characteristics across studies. CONCLUSION: The ELISAs in general dominate the comparative ranking among the d-dimer assays for sensitivity and negative likelihood ratio. For excluding PE or DVT, a negative result on quantitative rapid ELISA is as diagnostically useful as a normal lung scan or negative duplex ultrasonography finding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“METHODS We used several sources to guide our review processes, including recommendations by Lijmer and colleagues concerning avoidance of bias in studies of diagnostic tests (6), the Standards for Reporting Diagnostic Accuracy (STARD) statement (7, 8), and guidelines for meta-analyses of observational studies in epide…”
MethodEvaluation of D-Dimer in the Diagnosis of Suspected Deep-Vein Thrombosis
Wells, P. S., Anderson, D. R., Rodger, M., Forgie, M., Kearon, C., Dreyer, J., Kovacs, G., Mitchell, M., Lewandowski, B., & Kovacs, M. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa023153 · Cited by 1,552
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Wells, P. S., Anderson, D. R., Rodger, M., Stiell, I., Dreyer, J. F., Barnes, D., Forgie, M., Kovacs, G., Ward, J., & Kovacs, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00010 · Cited by 1,438
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
“110,111 The quantitative enzyme-linked immunosorbent assay (ELISA) or ELISA-derived assays have a diagnostic sensitivity of 95% or better and can therefore be used to exclude PE in patients with either a low or a moderate pre-test probability.”
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Prediction of Pulmonary Embolism in the Emergency Department: The Revised Geneva Score
Le Gal, G., Righini, M., Roy, P.-M., Sanchez, O., Aujesky, D., Bounameaux, H., & Perrier, A. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-3-200602070-00004 · Cited by 1,121
Tapson, V. F. (2008) · New England Journal of Medicine · doi:10.1056/nejmra072753 · Cited by 1,024
Age-Adjusted D-Dimer Cutoff Levels to Rule Out Pulmonary Embolism: The ADJUST-PE Study
Righini, M., Van Es, J., Den Exter, P. L., Roy, P.-M., Verschuren, F., Ghuysen, A., Rutschmann, O. T., Sanchez, O., Jaffrelot, M., Trinh-Duc, A., et al. (2014) · JAMA · doi:10.1001/jama.2014.2135 · Cited by 958
Kakkos, S. K., Gohel, M., Baekgaard, N., Bauersachs, R., Bellmunt-Montoya, S., Black, S. A., ten Cate-Hoek, A. J., Elalamy, I., Enzmann, F. K., Geroulakos, G., et al. (2021) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2020.09.023 · Cited by 743
Bates, S. M., Jaeschke, R., Stevens, S. M., Goodacre, S., Wells, P. S., Stevenson, M. D., Kearon, C., Schunemann, H. J., Crowther, M., Pauker, S. G., et al. (2012) · Chest · doi:10.1378/chest.11-2299 · Cited by 686
D-dimer antigen: current concepts and future prospects
Adam, S. S., Key, N. S., & Greenberg, C. S. (2009) · Blood · doi:10.1182/blood-2008-06-165845 · Cited by 668
Kyrle, P. A., & Eichinger, S. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71880-8 · Cited by 616
Diagnostic accuracy of D‐dimer test for exclusion of venous thromboembolism: a systematic review
DI NISIO, M., SQUIZZATO, A., RUTJES, A. W. S., BÜLLER, H. R., ZWINDERMAN, A. H., & BOSSUYT, P. M. M. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02328.x · Cited by 465
Definitions of the phenotypic manifestations of sickle cell disease
Ballas, S. K., Lieff, S., Benjamin, L. J., Dampier, C. D., Heeney, M. M., Hoppe, C., Johnson, C. S., Rogers, Z. R., Smith‐Whitley, K., Wang, W. C., et al. (2010) · American Journal of Hematology · doi:10.1002/ajh.21550 · Cited by 451
Stein, P. D., Chenevert, T. L., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Jablonski, K. A., Leeper, K. V., Naidich, D. P., et al. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-7-201004060-00008 · Cited by 392
Self-citationD‐Dimer for venous thromboembolism diagnosis: 20 years later
RIGHINI, M., PERRIER, A., DE MOERLOOSE, P., & BOUNAMEAUX, H. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.02981.x · Cited by 374
Suzuki, T., Distante, A., Zizza, A., Trimarchi, S., Villani, M., Salerno Uriarte, J. A., De Luca Tupputi Schinosa, L., Renzulli, A., Sabino, F., Nowak, R., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.833004 · Cited by 368
Guidance for the treatment of deep vein thrombosis and pulmonary embolism
Streiff, M. B., Agnelli, G., Connors, J. M., Crowther, M., Eichinger, S., Lopes, R., McBane, R. D., Moll, S., & Ansell, J. (2016) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-015-1317-0 · Cited by 344
Schouten, H. J., Geersing, G. J., Koek, H. L., Zuithoff, N. P. A., Janssen, K. J. M., Douma, R. A., van Delden, J. J. M., Moons, K. G. M., & Reitsma, J. B. (2013) · BMJ · doi:10.1136/bmj.f2492 · Cited by 342
Raja, A. S., Greenberg, J. O., Qaseem, A., Denberg, T. D., Fitterman, N., Schuur, J. D., & for the Clinical Guidelines Committee of the American College of Physicians* (2015) · Annals of Internal Medicine · doi:10.7326/m14-1772 · Cited by 340
Diagnostic Pathways in Acute Pulmonary Embolism: Recommendations of the PIOPED II Investigators
Stein, P. D., Woodard, P. K., Weg, J. G., Wakefield, T. W., Tapson, V. F., Sostman, H. D., Sos, T. A., Quinn, D. A., Leeper, K. V., Hull, R. D., et al. (2007) · Radiology · doi:10.1148/radiol.2421060971 · Cited by 330
Self-citationD-Dimer Concentrations in Normal Pregnancy: New Diagnostic Thresholds Are Needed
Kline, J. A., Williams, G. W., & Hernandez-Nino, J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.044883 · Cited by 251
Approach to Leg Edema of Unclear Etiology
Ely, J. W., Osheroff, J. A., Chambliss, M. L., & Ebell, M. H. (2006) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.19.2.148 · Cited by 217
“The variability among laboratory assays has been problematic, but a recent systematic review recommended the rapid quantitative ELISA as the most useful test.(25)”
MethodIntegrated strategies for the diagnosis of venous thromboembolism
WELLS, P. S. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02493.x · Cited by 190
Guideline on the investigation, management and prevention of venous thrombosis in children*
Chalmers, E., Ganesen, V., Liesner, R., Maroo, S., Nokes, T., Saunders, D., & Williams, M. (2011) · British Journal of Haematology · doi:10.1111/j.1365-2141.2010.08543.x · Cited by 188
“Whereas the negative predictive value of measurement of DDimer for VTE diagnosis has been validated in adults its use in children has not been validated (Stein et al, 2004).”
BackgroundFactors Associated With Positive D‐dimer Results in Patients Evaluated for Pulmonary Embolism
Kabrhel, C., Mark Courtney, D., Camargo, C. A., Plewa, M. C., Nordenholz, K. E., Moore, C. L., Richman, P. B., Smithline, H. A., Beam, D. M., & Kline, J. A. (2010) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2010.00765.x · Cited by 175
Erez, O., Novack, L., Beer-Weisel, R., Dukler, D., Press, F., Zlotnik, A., Than, N. G., Tomer, A., & Mazor, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093240 · Cited by 146
“5 mg/L is considered as the upper limit of the normal value in non-pregnant patients [80–82].”
BackgroundCOPD and PE: A Clinical Dilemma
Wood, K. (2008) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s1183 · Cited by 34
“A systematic review found a negative D-dimer to be as diagnostically useful as a normal lung perfusion scan or negative duplex ultrasonography in the setting of low pretest probability (Stein et al 2004).”
Metadata
- Authors
- Stein, P. D., Hull, R. D., Patel, K. C., Olson, R. E., Ghali, W. A., Brant, R., Biel, R. K., Bharadia, V., & Kalra, N. K.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2004-04-20
- Volume
- 140
- Issue
- 8
- Pages
- 589-602
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1981156855
- Cited by
- 800
- References
- 25
- FWCI
- 35.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.