Medication Dispensing Errors and Potential Adverse Drug Events before and after Implementing Bar Code Technology in the Pharmacy
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Many dispensing errors made in hospital pharmacies can harm patients. Some hospitals are investing in bar code technology to reduce these errors, but data about its efficacy are limited. OBJECTIVE: To evaluate whether implementation of bar code technology reduced dispensing errors and potential adverse drug events (ADEs). DESIGN: Before-and-after study using direct observations. SETTING: Hospital pharmacy at a 735-bed tertiary care academic medical center. INTERVENTION: A bar code-assisted dispensing system was implemented in 3 configurations. In 2 configurations, all doses were scanned once during the dispensing process. In the third configuration, only 1 dose was scanned if several doses of the same medication were being dispensed. MEASUREMENTS: Target dispensing errors, defined as dispensing errors that bar code technology was designed to address, and target potential ADEs, defined as target dispensing errors that can harm patients. RESULTS: In the pre- and post-bar code implementation periods, the authors observed 115,164 and 253,984 dispensed medication doses, respectively. Overall, the rates of target potential ADEs and all potential ADEs decreased by 74% and 63%, respectively. Of the 3 configurations of bar code technology studied, the 2 configurations that required staff to scan all doses had a 93% to 96% relative reduction in the incidence of target dispensing errors (P < 0.001) and 86% to 97% relative reduction in the incidence of potential ADEs (P < 0.001). However, the configuration that did not require scanning of every dose had only a 60% relative reduction in the incidence of target dispensing errors (P < 0.001) and an increased (by 2.4-fold) incidence of target potential ADEs (P = 0.014). There were several potentially life-threatening ADEs involving intravenous dopamine and intravenous heparin in that configuration. LIMITATIONS: The authors used surrogate outcomes; did not mask assessors to the purpose of study; and excluded the controlled substance fill process (a process with low error rates at baseline) from the study, which may bias the combined decrease in error rates toward a larger magnitude. CONCLUSIONS: The overall rates of dispensing errors and potential ADEs substantially decreased after implementing bar code technology. However, the technology should be configured to scan every dose during the dispensing process.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Brennan, T. A., Leape, L. L., Laird, N. M., Hebert, L., Localio, A. R., Lawthers, A. G., Newhouse, J. P., Weiler, P. C., & Hiatt, H. H. (1991) · New England Journal of Medicine · doi:10.1056/nejm199102073240604 · Cited by 4,627
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127 · cited 1×
“edication errors in hospitals are common (1, 2 ), and dispensing errors made in the pharmacy contribute considerably to these errors (3).”
BackgroundSelf-citationRole of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
Bates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Self-citationMaking health care safer: a critical analysis of patient safety practices.
Shojania, K. G., Duncan, B. W., McDonald, K. M., Wachter, R. M., & Markowitz, A. J. (2001) · PubMed Central · Cited by 1,612
Pharmacist Participation on Physician Rounds and Adverse Drug Events in the Intensive Care Unit
Leape, L. L. (1999) · JAMA · doi:10.1001/jama.282.3.267 · Cited by 1,599 · cited 1×
“Given these magnitudes in error reduction, bar code technology in the pharmacy compares favorably with other patient safety interventions, such as computerized physician order entry (17, 18) and pharmacist participation in intensive care unit rounds ( 19 , 20).”
Self-citationSystems Analysis of Adverse Drug Events
Leape, L. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530010049034 · Cited by 1,404 · cited 2×
“edication errors in hospitals are common (1, 2), and dispensing errors made in the pharmacy contribute considerably to these errors ( 3 ).”
BackgroundAdverse Drug Events in Ambulatory Care
Gandhi, T. K., Weingart, S. N., Borus, J., Seger, A. C., Peterson, J., Burdick, E., Seger, D. L., Shu, K., Federico, F., Leape, L. L., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020703 · Cited by 1,345 · cited 1×
“The level of potential harm was further classified as significant, serious, or life-threatening ( 15 , 16).”
BackgroundSelf-citationBush, G. W. (2006) · Cited by 756
Kucukarslan, S. N., Peters, M., Mlynarek, M., & Nafziger, D. A. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.17.2014 · Cited by 514 · cited 1×
“Given these magnitudes in error reduction, bar code technology in the pharmacy compares favorably with other patient safety interventions, such as computerized physician order entry (17, 18) and pharmacist participation in intensive care unit rounds (19, 20 ).”
Research works printed but not linked: 2
- Cina JL, 2006, Jt Comm J Qual Patient Saf, 32, 73
- 2004, Fed Regist, 69, 9119
Cited by
Items 101–200 of 332
Errores de medicación en el Servicio de Medicina de un hospital de alta complejidad
Ann-Loren Smith, M., Inés Ruiz, A., & Marcela Jirón, A. (2014) · Revista médica de Chile · doi:10.4067/s0034-98872014000100007 · Cited by 26
Álvarez‐Díaz, A. M., Silveira, E. D., Menéndez-Conde, C. P., RECUENCO, R. P., SILANES, E. G. D. S. L. D., Pérez, J. S., Jiménez, T. M., & Vicedo, T. B. (2010) · Farmacia Hospitalaria · doi:10.1016/j.farma.2009.12.003 · Cited by 26
Oldland, A. R., Golightly, L. K., May, S. K., Barber, G. R., & Stolpman, N. M. (2015) · Hospital Pharmacy · doi:10.1310/hpj5001-34 · Cited by 25
Wakefield, D. S., Ward, M. M., Loes, J. L., & O'Brien, J. R. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2010.004267 · Cited by 25
Alharthi, H., Sultana, N. N., Al-Amoudi, A., & Basudan, A. (2015) · PubMed · Cited by 25
Retrospective analysis of DATIX dispensing error reports from Scottish NHS hospitals
Irwin, A., Ross, J., Seaton, J., & Mearns, K. J. (2011) · International Journal of Pharmacy Practice · doi:10.1111/j.2042-7174.2011.00136.x · Cited by 24
“The utilisation of barcode technology has also been shown to reduce selection error.([29])”
BackgroundMeaningful Use of Computerized Prescriber Order Entry
Classen, D. C., Bates, D. W., & Denham, C. R. (2010) · Journal of Patient Safety · doi:10.1097/pts.0b013e3181d108db · Cited by 24
“Medication management, including administration and dispensing, is included because these care processes, like order writing, can be made significantly safer through the use of such interventions as an electronic medication administration record (eMAR) with bar coding.(14) Classen et al J Patient Saf & Volume 6, Numbe…”
BackgroundSelf-citationElectronic health records: current and future use
Peters, S. G., & Khan, M. A. (2014) · Journal of Comparative Effectiveness Research · doi:10.2217/cer.14.44 · Cited by 25
Chen, Y., Wu, X., Huang, Z., Lin, W., Li, Y., Yang, J., & Li, J. (2019) · Research in Social and Administrative Pharmacy · doi:10.1016/j.sapharm.2019.02.006 · Cited by 26
Integration of a Commercial Barcode-Assisted Medication Dispensing System in a Teaching Hospital
Berdot, S., Boussadi, A., Vilfaillot, A., Depoisson, M., Guihaire, C., Durieux, P., Lê, L. M. M., & Sabatier, B. (2019) · Applied Clinical Informatics · doi:10.1055/s-0039-1694749 · Cited by 24
Health technology, quality and safety in a learning health system
Borycki, E. M., & Kushniruk, A. W. (2023) · Healthcare Management Forum · doi:10.1177/08404704221139383 · Cited by 23
“Researchers have created taxonomies, methods, and educational approaches to improve quality, safety, and risk management in a digital health system.(10-55,59) Training programs are available and trained health professionals (i.”
BackgroundSafeguarding the process of drug administration with an emphasis on electronic support tools
Seidling, H. M., Lampert, A., Lohmann, K., Schiele, J. T., Send, A. F. J., Witticke, D., & Haefeli, W. E. (2013) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12191 · Cited by 25
Holden, R. J., Brown, R., Scanlon, M. C., Rivera, A. J., & Karsh, B. (2014) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2014.04.003 · Cited by 23
Poole, S. G., Kwong, E., Mok, B., Mulqueeny, B., Yi, M., Percival, M. A., Marsom, E. N., Duncan, C., & Graudins, L. V. (2021) · Journal of Pharmacy Practice and Research · doi:10.1002/jppr.1709 · Cited by 22
Abdellatif, A., Bagian, J. P., Barajas, E. R., Cohen, M. R., Cousins, D. D., Denham, C. R., Essinger, K., Gegelashvili, G., Glenister, H., Hoffman, C., et al. (2007) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(07)33127-9 · Cited by 22
Callum, J., Etchells, E. E., & Shojania, K. G. (2019) · Transfusion · doi:10.1111/trf.15160 · Cited by 21
“Success with ePPID has also been reported to reduce errors in pathology samples from an endoscopy suite,(22) to reduce wrong patient or wrong product errors in a nuclear pharmacy,(23) and to reduce wrong medication dispensing and administration.(24,25) The publications of a few before–after implementation studies of e…”
BackgroundShane, R. R. (2011) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp110058 · Cited by 21
Human Factors Perspectives on a Systemic Approach to Ensuring a Safer Medication Delivery Process
Cafazzo, J. A., Trbovich, P., Cassano-Piché, A., Chagpar, A., Rossos, P. G., Vicente, K. J., & Easty, A. (2009) · Healthcare Quarterly · doi:10.12927/hcq.2009.20969 · Cited by 21
“This investment has been in part due to the strong advocacy for the use of technology to address patient safety, such as computerized physician order entry (CPOE) , bar-coding and smart pump infusion systems (Bates 2000, 2007; Poon et al. 2006; Smetzer 2002; Vanderveen 2007; Young 2006).”
BackgroundSafety and risk management in hospitals.
Dückers, M., Faber, M. J., Cruijsberg, J. K., Grol, R. P. T. M., Schoonhoven, L., & Wensing, M. (2009) · Data Archiving and Networked Services (DANS) · Cited by 19
Medication dispensing errors in a French military hospital pharmacy
Bohand, X., Aupée, O., Garlantezec, P. L., Mullot, H., Lefeuvre, L., & Simon, L. (2009) · Pharmacy World & Science · doi:10.1007/s11096-009-9290-3 · Cited by 19
“Finally, it is advisable to indicate that automated medication dispensing systems and bar-code technology may reduce pharmacy dispensing error rates [15, 34–36].”
BackgroundNurse Interruptions Pre- and Postimplementation of a Point-of-Care Medication Administration System
Stamp, K. D., & Willis, D. G. (2010) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e3181d4a13f · Cited by 19
“In other words, POC implementation did not change the fact that nurses needed to (1) contact the MD to obtain medication orders, (2) address untimely distribution of medications from pharmacy, and (3) circumvent wrong drugs being delivered at times.”
BackgroundStipp, M. M., Deng, H., Kong, K., Moore, S., Hickman, R. L., & Nanji, K. C. (2022) · Medicine · doi:10.1097/md.0000000000031432 · Cited by 18
Wang, B. N.-T., Brummond, P. W., & Stevenson, J. G. (2015) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp150135 · Cited by 18
Technology in medications safety
Al‐Worafi, Y. M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819837-7.00018-2 · Cited by 17
Kim, J. Y., Marshall, V. D., Rowell, B. E., Chen, Q., Zheng, Y., Lee, J. D., Kontar, R. A., Lester, C. A., & Yang, X. J. (2025) · JMIR Human Factors · doi:10.2196/60273 · Cited by 17
“The adoption of such systems within pharmacies and broader health care environments has led to a notable reduction in medication errors [7-10].”
Pharmaceutical Blister Package Identification Based on Induced Deep Learning
Han, Y., Chung, S., Xiao, Q., Wang, J.-S., & Su, S. (2021) · IEEE Access · doi:10.1109/access.2021.3097181 · Cited by 18
“At present, the main methods adopted are bar code drug delivery system [7], wireless drug detection cabinet [8], automatic drug cabinet [9] etc.”
BackgroundMethodGreenberg, C. C., & Gawande, A. A. (2008) · Advances in Surgery · doi:10.1016/j.yasu.2008.03.007 · Cited by 17
Rahmanzade, R., Cabrera-Diaz, F., Zaugg, C., Schüetz, P., & Salili, A. R. (2020) · Thrombosis Journal · doi:10.1186/s12959-020-00227-w · Cited by 17
“3%) and the subsequent adverse events could be prevented in about 70% of cases [3, 22].”
BackgroundLaw, M., Zeng, S., Koo, J., Verches, D., Lam, L., & Martini, N. D. (2021) · International Journal of Clinical Pharmacy · doi:10.1007/s11096-021-01238-x · Cited by 16
Current status of preparation and distribution of medicines
Oishi, R. (2009) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp080611 · Cited by 16
Oldland, A. R., Golightly, L. K., May, S. K., Barber, G. R., & Stolpman, N. M. (2015) · Hospital Pharmacy · doi:10.1310/hpj5001-034 · Cited by 15
Fanikos, J. R., Erickson, A. L., Munz, K., Sanborn, M. D., Ludwig, B. C., & Hassel, T. V. (2007) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp060552 · Cited by 15
Mohanty, M., Lawal, O. D., Skeer, M. R., Lanier, R. K., Erpelding, N., & Katz, N. P. (2018) · Therapeutic Advances in Drug Safety · doi:10.1177/2042098618773013 · Cited by 15
Medication Safety Improves after Implementation of Positive Patient Identification
Heelon, M. W., Siano, B., Douglass, L., Liebro, P., Spath, B., Kudler, N. R., Kerr, G., & Higgins, T. L. (2010) · Applied Clinical Informatics · doi:10.4338/aci-2010-02-ra-0011 · Cited by 15
“Technology may improve clinical practice [1, 2], but may also have unintended consequences [13].”
BackgroundUnderstanding Pharmacists’ Intention to Use Medical Apps
Ng, S.-N., Matanjun, D., D'Souza, U. J. A., & Alfred, R. (2015) · eJournal of health informatics · Cited by 15
Adverse Medical Events in the NICU
Morriss, F. H. (2008) · NeoReviews · doi:10.1542/neo.9-1-e8 · Cited by 15
An assessment of drug administration compliance in a university hospital centre
Alemanni, J., Touzin, K., Bussières, J., Descôteaux, R., & Lemay, M. (2010) · Journal of Evaluation in Clinical Practice · doi:10.1111/j.1365-2753.2009.01221.x · Cited by 14
“This concerns steps related to drug labelling, which in the long run could be corrected by introducing bar code technology throughout the facility [26,27].”
BackgroundAn Interview with Michael Cohen
Bates, D. W. (2008) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(08)34089-6 · Cited by 13
Self-citationWang, H., Tao, D., & Yan, M. (2021) · Quality Management in Health Care · doi:10.1097/qmh.0000000000000303 · Cited by 13
Laing, L., Salema, N.-E., Jeffries, M., Shamsuddin, A., Sheikh, A., Chuter, A., Waring, J. J., Avery, A. J., & Keers, R. N. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275633 · Cited by 13
Medication Safety in Hospitals: Avoiding Medication Errors in the Medication use Process
(2013) · Advances in Pharmacoepidemiology & Drug Safety · doi:10.4172/2167-1052.1000134 · Cited by 13
Preventing medication errors in the information age
Godshall, M., & Riehl, M. (2018) · Nursing · doi:10.1097/01.nurse.0000544230.51598.38 · Cited by 13
Emmerton, L., Rizk, M., Bedford, G., & Lalor, D. (2014) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.12247 · Cited by 12
“In both cases, best-practice interventions, such as use of barcode scanners during dispensing[27-29] and administration[30], and separation of confusable medicines in storage[8], are recommended.”
BackgroundTech-Check-Tech Pilot in a Regional Public Psychiatric Inpatient Facility
McKee, J. R., & Zimmerman, M. (2011) · Hospital Pharmacy · doi:10.1310/hpj4607-501 · Cited by 12
“In addition to the training aspect, the increased use of technology such as bar code–assisted error detection may also enhance the accuracy of either technicians or pharmacists in this quality control function.(11-13) Such bar code–assisted technology was not a part of this pilot.”
BackgroundPalmieri, P. A., Peterson, L. T., & Corazzo, L. B. (2011) · Advances in health care management · doi:10.1108/s1474-8231(2011)0000010023 · Cited by 11
“HIT is a label to describe a variety of computer and electronic applications such as bar code medication systems (BCMS; Poon et al., 2006), electronic health records (EHR; Sidrov, 2006), computerized provider order entry (CPOE; Bates, 2005b), and decision support systems (DSS; Kawamoto, Caitlin, Balas, & Lobach, 2005).”
Iqbal, M. S., Tahir, M., Upadhyay, D. K., Iqbal, M., Rajan, S., & Albassam, A. A. (2020) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/jpbs.jpbs_263_20 · Cited by 11
“In a healthcare system, a pharmacist is the first person accessible to patients during the dispensing of medicine.[15] Based on ethnicity, the current study showed a nonsignificant difference and the results from different ethnic groups were almost similar.”
BackgroundResultKey components of intravenous chemotherapy labeling: A systematic review and practice guideline
Trudeau, M., Green, E., Cosby, R., Charbonneau, F., Easty, T., Ko, Y., Marchand, P., David, U., Berger, N., & Hertz, S. (2010) · Journal of Oncology Pharmacy Practice · doi:10.1177/1078155210385160 · Cited by 10
“In the Poon et al.(19) study, a trained research pharmacist, in a 735-bed tertiary care academic medical center, monitored all medications that had been dispensed by the pharmacy to look for dispensing errors.”
BackgroundResultInfluentialThink Bar-Code Medication Administration Eliminates Adverse Drug Events? Think Again!
O’Malley, P. A. (2008) · Clinical Nurse Specialist · doi:10.1097/01.nur.0000325383.99717.e5 · Cited by 10
“Bar-code medication administration is the application of a widely used and reliable commercial technology to prevent medication errors.(1) A unique identifier or bar code placed on each medication is read by an optical scanner.”
BackgroundMethodBussières, J., & Lefebvre, P. (2015) · Pharmactuel · Cited by 10
Wang, H., & Or, C. K. (2019) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819870700 · Cited by 10
“drawers (Cooper, Barron, Gallagher, & Sciarra, 2007), pharmacy robots (Franklin, O’Grady, Voncina, Popoola, & Jacklin, 2008), and barcode technology (Poon et al., 2006), and the results provide empirical evidence to support some economic strategies for reducing medication errors.”
BackgroundQuali-quantitative analysis: a new model for evaluation of unusual cases in hospital performance?
Bell, E. (2007) · Australian Health Review · doi:10.1071/ah070s86 · Cited by 9
Kayden, S. R., Anderson, P. D., Freitas, R., & Platz, E. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781139030557.017 · Cited by 10
Intelligent Infusion Technologies: Integration of a Smart System to Enhance Patient Care
Agius, C. R. (2012) · Journal of Infusion Nursing · doi:10.1097/nan.0b013e3182706423 · Cited by 9
“Included in these statistics were 710 deaths, which resulted in the recall of 87 infusion pumps.3 Approximately 20% of high-alert medications, when used in error, have an even higher risk for causing harm.4 Anticoagulants, opiates, insulin, and sedatives remain among the high-alert medications, and the inappropriate u…”
Binobaid, S., Almeziny, M., & Fan, I. (2016) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2016.11.005 · Cited by 9
“Furthermore, (Poon et al., 2006) a previous study concluded that the implementation of bar code technology decreases the medication errors in health-care.”
BackgroundPoulsen, J. H., Rishoej, R. M., Fischer, H., Kart, T., Nørgaard, L. S., Sevel, C., Dieckmann, P., & Clemmensen, M. H. (2019) · Therapeutic Advances in Drug Safety · doi:10.1177/2042098619859995 · Cited by 9
Ababneh, M., Al-Azzam, S. I., Alzoubi, K. H., & Rababa’h, A. M. (2020) · Journal of Pharmaceutical Health Services Research · doi:10.1111/jphs.12356 · Cited by 9
A Rasch model analysis of technology usage in Minnesota hospitals
Olson, J. R., Belohlav, J. A., & Cook, L. S. (2012) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2012.01.008 · Cited by 9
“[49] E.”
Intervention to reduce the use of unsafe abbreviations in a teaching hospital
Alshaikh, M., Mayet, A. Y., Adam, M., Ahmed, Y., & Aljadhey, H. S. (2012) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2012.10.006 · Cited by 9
“…and the participation of pharmacists in the medication monitoring process (Committee on Identifying and Medication Errors, 2006; Bates et al., 1998; Poon et al., 2006; Cohen et al., 2005; Vira et al., 2006; Nester and Hale, 2002; Bond et al., 2000, 1999, 2002; McFadzean et al., 2003; Strunk et…”
BackgroundCurrent practices for labeling medications in hospitals in Riyadh, Saudi Arabia
Alkhani, S., Ahmed, Y., Bin-Sabbar, N., Almoghirah, H., Alturki, A. S., Albanyan, H., Adam, M., Saleem, F., Aljadhey, H. S., Hassali, M. A., et al. (2012) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2012.12.002 · Cited by 8
“The proper use of technology throughout the medication use process was shown to possibly improve medication safety and minimize medication errors (Kuiper et al., 2007; Poon et al., 2006).”
Díaz, A. M. Á., Silveira, E. D., Menéndez-Conde, C. P., RECUENCO, R. P., SILANES, E. G. D. S. L. D., Pérez, J. S., Jiménez, T. M., & Vicedo, T. B. (2010) · Farmacia Hospitalaria (English Edition) · doi:10.1016/s2173-5085(10)70001-0 · Cited by 8
Understanding how human factors can cause errors in the operating theatre
White, N., Lowes, R. H., & Hormis, A. P. (2015) · Journal of Operating Department Practitioners · doi:10.12968/jodp.2015.3.2.82 · Cited by 8
Survey of Hospital Pharmacy Directors: Assessment of the Current State of Unit-Dose Acquisition
Mason, S. J., Meller, R. D., Thomas, L. M. B., Pazour, J. A., & Root, S. (2010) · Journal of Pharmacy Technology · doi:10.1177/875512251002600102 · Cited by 8
“Purchase bulk medications; 0 (0) 3 (8) 1 (7) 3 (25)”
An Exploratory Pilot Study on Supply Chain Data Standards in a Hospital Pharmacy
Jayaraman, R., Buyurgan, N., Rardin, R. L., Varghese, V. M., & Pazour, J. A. (2015) · Engineering Management Journal · doi:10.1080/10429247.2015.1062692 · Cited by 8
“…safety by mitigating the risk related to misidentification or administration of the wrong medications through the use of barcodebased medication administration (American Society of Hospital Pharmacists, 2010; Escoto et al., 2004; Helmons, Lindsay, Wargel, & Daniels, 2009; Poon et al., 2005, 2010).”
BackgroundAl‐Fadel, N., Mahmoud, M. A., Dabliz, R., Tabbara, O., & Aljadhey, H. S. (2016) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2015-000872 · Cited by 8
Aronson, J. K. (2010) · Side effects of drugs annual · doi:10.1016/s0378-6080(10)32050-2 · Cited by 8
Development of Electronic Chemotherapy Roadmaps for Pediatric Oncology Patients
Allen, S. W., Hayashi, R. J., Jones, S., Drozda, M. H., Brown, R. L., Lackey, I. T., Price, A., Newland, J. M., Robinson, D. L., Carey, C. J., et al. (2018) · Journal of Pediatric Oncology Nursing · doi:10.1177/1043454218767876 · Cited by 8
Dasgupta, A., Sansgiry, S. S., Jacob, S. M., Frost, C. P., Dwibedi, N., & Tipton, J. A. (2011) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e318215b770 · Cited by 7
Weir, N., Preston, K., Newham, R., & Bennie, M. (2020) · Health Policy and Technology · doi:10.1016/j.hlpt.2020.11.005 · Cited by 7
Hashimoto, K., & Tripathi, S. R. (2022) · Optics · doi:10.3390/opt3020012 · Cited by 7
Gilmartin‐Thomas, J., Marriott, J., & Hussainy, S. Y. (2013) · International Journal of Clinical Pharmacy · doi:10.1007/s11096-013-9839-z · Cited by 7
Goldsmith, D., & Siegel, M. (2012) · International Journal of Information Technologies and Systems Approach · doi:10.4018/jitsa.2012010102 · Cited by 7
“Implementations resulting in unintended negative " side-effects " include computerized prescriber order entry (Zhan et al, 2006), electronic health records (Sidorov, 2006), bar code technology (Poon, 2006), and overall HIT systems (Ash et al, 2003, Wears & Berg, 2005, and Kohn 2000).”
Place de l’erreur médicale dans le système de soins
Latil, F. (2007) · Acta Endoscopica · doi:10.1007/bf02961798 · Cited by 7
Third-party repackaging in hospital pharmacy unit dose acquisition
Meller, R. D., Pazour, J. A., Thomas, L. M. B., Mason, S. J., Root, S., & Churchill, W. W. (2010) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp090184 · Cited by 7
“A study of medication dispensing errors that occurred before and after implementing bar-code technology revealed that bar-code technology in the pharmacy compares favorably with other patient safety interventions.(4) Given the high volume of medications dispensed in a hospital, even small reductions in errors will res…”
ResultSelf-citationAnkam, V. S. S., Hong, G. Y., & Fong, A. C. M. (2024) · Applied Sciences · doi:10.3390/app14188426 · Cited by 6
A Pharmacy Blueprint for Electronic Medical Record Implementation Success
Bach, D. S., Risko, K., Zaran, F. K., Farber, M. S., & Polk, G. J. (2015) · Hospital Pharmacy · doi:10.1310/hpj5006-484 · Cited by 6
Improving radiopharmaceutical supply chain safety by implementing bar code technology
Matanza, D., Hallouard, F., Rioufol, C., Fessi, H., & Fraysse, M. (2014) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000177 · Cited by 6
E-Health: A Bridge to People-Centered Health Care
Moumtzoglou, A. S. (2010) · IGI Global eBooks · doi:10.4018/978-1-61692-843-8.ch005 · Cited by 6
Lawal, B. K., Alhaji, A. A., Maiha, B. B., & Mohammed, S. (2020) · Journal of Pharmacy & Bioresources · doi:10.4314/jpb.v17i1.9 · Cited by 6
“Studies have shown the relevance of IT interventions in improving medication safety [1,6,20,21].”
BackgroundAVALIAÇÕES FARMACOECONÔMICAS EM VIGILÂNCIA DE MEDICAMENTOS.
Mastroianni, P. D. C., Abjaude, S. A. R., & Varallo, F. R. (2014) · REVISTA SAÚDE & CIÊNCIA · doi:10.35572/rsc.v3i2.103 · Cited by 6
Improving the Intensive Care Unit
Garland, A. (2009) · Springer eBooks · doi:10.1007/978-0-387-77893-8_59 · Cited by 6
Chen, D.-W., Chase, V. J., Burkhardt, M. E., & Agulto, A. Z. (2016) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(16)42065-9 · Cited by 6
Choi, J. S., & Kim, D. (2009) · Journal of Korean Society of Medical Informatics · doi:10.4258/jksmi.2009.15.3.303 · Cited by 6
Functional Requirements of Pharmacy’s Information System in Hospitals
Farzandipour, M., Meidani, Z., Riazi, H., & Jabali, M. S. (2017) · Iranian Journal of Medical Informatics · doi:10.24200/ijmi.v6i1.111 · Cited by 6
“Poon and colleagues reflected that applying barcode technology in pharmacy before sending drug to the ward of patient care location is followed by 36% decrease in medication errors and 63% decrease in side effects of drug [40].”
BackgroundTo err is human: medication patient safety in aged care, a case study
Gilbert, J., & Kim, J. (2018) · Quality in Ageing and Older Adults · doi:10.1108/qaoa-11-2017-0048 · Cited by 6
Utilisation des codes-barres dans le cadre du circuit du médicament en établissement de santé
Bussières, J., & Lebel, D. (2009) · Pharmactuel · Cited by 6
Beyond mixed case lettering: reducing the risk of wrong drug errors requires a multimodal response
Lambert, B. L., Schroeder, S. R., Cohen, M. R., & Paparella, S. F. (2022) · BMJ Quality & Safety · doi:10.1136/bmjqs-2022-014841 · Cited by 6
Alshehri, N., & Alanazi, A. (2023) · Pharmacy · doi:10.3390/pharmacy11040119 · Cited by 6
Ludwig‐Beymer, P., Williams, P., & Stimac, E. (2012) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e31825a8db3 · Cited by 5
“…3 Additional research suggests that when used as intended, with each medication dose scanned during the dispensing process, medication dispensing 4 93% to 96% relative reduction in the incidence of target dispensing errors and 86% to 97% relative reduction in the incidence of potential adverse…”
BackgroundMinimization of patient misidentification through proximity-based medical record retrieval
Natarajan, S., Wottawa, C. R., & Dutson, E. (2009) · ICME International Conference on Complex Medical Engineering (CME) · doi:10.1109/iccme.2009.4906655 · Cited by 5
Ros, H., & de Vreeze-Wesselink, E. (2009) · Cited by 5
Medication Errors: A Case-Based Review
Pop, M. K., & Finocchi, M. (2016) · AACN Advanced Critical Care · doi:10.4037/aacnacc2016172 · Cited by 5
New Trends in Healthcare Information Systems (HIS) Integration
Koumaditis, K., Themistocleous, M., & Morabito, V. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-3986-7.ch041 · Cited by 6
Automated, Web-Based Solution for Bidirectional EHR–Infusion Pump Communication
Griffiths, S., Sapirstein, A., Guzman, J. C., Soriano, Z., & Ravitz, A. (2019) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-53.1.30 · Cited by 5
Implementing a Care Planning System: How to Fix the Most Pervasive Errors in Health Care
Hammes, B. J., Briggs, L. A., Silvester, W., Wilson, K. S., Schettle, S., Maycroft, J. R., Sandoval, J., Orders, A. E., & Stern, M. (2014) · Springer eBooks · doi:10.1007/978-1-4939-0407-5_12 · Cited by 5
Sistemas de identificación de pacientes en hospitales de Cataluña
Martínez, L., Gimeno, V., Anglès, R., Bañeres, J., Torralba, L., & Manzanera, R. L. (2008) · Revista de Calidad Asistencial · doi:10.1016/s1134-282x(08)72128-6 · Cited by 5
Elnour, A. A., Ellahham, N. H., & Qassas, H. I. A. (2007) · Journal of Patient Safety · doi:10.1097/pts.0b01e31815a6110 · Cited by 5
“The overall rates of dispensing errors and potential ADEs substantially decreased after implementing bar code technology.(39)”
BackgroundLearning from medication errors through a nationwide reporting programme
Cheung, K. C. (2015) · Radboud Repository (Radboud University) · Cited by 5
Karnwal, A., Nesterova, N., Saklani, N., Rehman, A.-U., Pant, G., Garg, N., Mishra, S., Ghorai, T. K., Kumar, G., & Kumar, D. (2026) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2026.101769 · Cited by 4
Improving Quality of Care in ICUs
Garland, A. (2009) · Springer eBooks · doi:10.1007/978-88-470-1436-7_8 · Cited by 4
EMeH: Extensible mobile platform for healthcare
Biały, T., Kobusiński, J., Malecki, M., & Stefaniak, K. (2011) · Annals of Computer Science and Information Systems · Cited by 4
Metadata
- Authors
- Poon, E. G., Cina, J. L., Churchill, W., Patel, N., Featherstone, E., Rothschild, J. M., Keohane, C. A., Whittemore, A. D., Bates, D. W., & Gandhi, T. K.
- Affiliations
- Brigham and Women's Hospital (US)
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2006-09-19
- Volume
- 145
- Issue
- 6
- Pages
- 426-434
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1979757243
- Semantic Scholar
- cd736842d9ae46f2215797eeef9cf827e322da18
- Cited by
- 294
- References
- 24
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 9 · 2023: 6 · 2022: 7 · 2021: 10 · 2020: 10 · 2019: 9 · 2018: 11 · 2017: 9 · 2016: 10 · 2015: 19 · 2014: 22 · 2013: 16 · 2012: 21
- FWCI
- 34.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- UCLA - Biblioteca de Ciencias de la Salud (submittedVersion)
- Annals of Internal Medicine
- Funders
- Agency for Healthcare Research and Quality (HS14053-02)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Medicine › Geriatrics and Gerontology › Pharmaceutical Practices and Patient Outcomes
- Health Sciences › Health Professions › Pharmacy › Pharmacy and Medical Practices
- Keywords
- medication dispensing errors, barcode technology, adverse drug reactions, hospital pharmacy, drug safety, error reduction, intravenous heparin, technology configuration, patient harm prevention, medication errors
- MeSH terms
- Electronic Data Processing, Drug Labeling, Humans, Medication Errors, Pharmacy Service, Hospital, United States, Safety Management, Drug-Related Side Effects and Adverse Reactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.