Gadolinium-Enhanced Magnetic Resonance Angiography for Pulmonary Embolism: A Multicenter Prospective Study (PIOPED III)
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The accuracy of gadolinium-enhanced magnetic resonance pulmonary angiography and magnetic resonance venography for diagnosing pulmonary embolism has not been determined conclusively. OBJECTIVE: To investigate performance characteristics of magnetic resonance angiography, with or without magnetic resonance venography, for diagnosing pulmonary embolism. DESIGN: Prospective, multicenter study from 10 April 2006 to 30 September 2008. SETTING: 7 hospitals and their emergency services. PATIENTS: 371 adults with diagnosed or excluded pulmonary embolism. MEASUREMENTS: Sensitivity, specificity, and likelihood ratios were measured by comparing independently read magnetic resonance imaging with the reference standard for diagnosing pulmonary embolism. Reference standard diagnosis or exclusion was made by using various tests, including computed tomographic angiography and venography, ventilation-perfusion lung scan, venous ultrasonography, d-dimer assay, and clinical assessment. RESULTS: Magnetic resonance angiography, averaged across centers, was technically inadequate in 25% of patients (92 of 371). The proportion of technically inadequate images ranged from 11% to 52% at various centers. Including patients with technically inadequate images, magnetic resonance angiography identified 57% (59 of 104) with pulmonary embolism. Technically adequate magnetic resonance angiography had a sensitivity of 78% and a specificity of 99%. Technically adequate magnetic resonance angiography and venography had a sensitivity of 92% and a specificity of 96%, but 52% of patients (194 of 370) had technically inadequate results. LIMITATION: A high proportion of patients with suspected embolism was not eligible or declined to participate. CONCLUSION: Magnetic resonance pulmonary angiography should be considered only at centers that routinely perform it well and only for patients for whom standard tests are contraindicated. Magnetic resonance pulmonary angiography and magnetic resonance venography combined have a higher sensitivity than magnetic resonance pulmonary angiography alone in patients with technically adequate images, but it is more difficult to obtain technically adequate images with the 2 procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Multidetector Computed Tomography for Acute Pulmonary Embolism
Stein, P. D., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Leeper, K. V., Popovich, J., Quinn, D. A., Sos, T. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052367 · Cited by 1,660
Self-citationWells, P. S., Anderson, D. R., Rodger, M., Stiell, I., Dreyer, J. F., Barnes, D., Forgie, M., Kovacs, G., Ward, J., & Kovacs, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00010 · Cited by 1,438
Rivaroxaban versus Enoxaparin for Thromboprophylaxis after Hip Arthroplasty
Eriksson, B. I., Borris, L. C., Friedman, R. J., Haas, S., Huisman, M. V., Kakkar, A. K., Bandel, T. J., Beckmann, H., Muehlhofer, E., Misselwitz, F., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800374 · Cited by 1,433
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124 · cited 3×
“Exclusion of PE Normal D-dimer result by quantitative rapid enzyme-linked immunosorbent assay (D-dimer level 500 ng/mL) in a patient with low or intermediate probability according to the Wells criteria (9); if whole blood or latex D-dimer was used, clinical assessment had to be low probability 95 (36)”
MethodEriksson, B. I., Dahl, O. E., Rosencher, N., Kurth, A. A., van Dijk, C. N., Frostick, S. P., Prins, M. H., Hettiarachchi, R., Hantel, S., Schnee, J., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61445-7 · Cited by 1,116
Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism
Wells, P. S., Ginsberg, J. S., Anderson, D. R., Kearon, C., Gent, M., Turpie, A. G., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., et al. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-12-199812150-00002 · Cited by 1,002
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
“170,171 Their results show that this technique, although promising, is not yet ready for clinical practice due to its low sensitivity, high proportion of inconclusive MRA scans, and lowavailability in most emergency settings.”
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Pulmonary embolism and deep vein thrombosis
Goldhaber, S. Z., & Bounameaux, H. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61904-1 · Cited by 1,054
Deep vein thrombosis and pulmonary embolism
Di Nisio, M., van Es, N., & Büller, H. R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30514-1 · Cited by 994
Agnelli, G., & Becattini, C. (2010) · New England Journal of Medicine · doi:10.1056/nejmra0907731 · Cited by 444
Chronic Thromboembolic Pulmonary Hypertension
Piazza, G., & Goldhaber, S. Z. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0910203 · Cited by 410
SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
Leiner, T., Bogaert, J., Friedrich, M. G., Mohiaddin, R., Muthurangu, V., Myerson, S., Powell, A. J., Raman, S. V., & Pennell, D. J. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00682-4 · Cited by 328
Leung, A. N., Bull, T. M., Jaeschke, R., Lockwood, C. J., Boiselle, P. M., Hurwitz, L. M., James, A. H., McCullough, L. B., Menda, Y., Paidas, M. J., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201108-1575st · Cited by 230
Self-citationIsrael, O., Pellet, O., Biassoni, L., De Palma, D., Estrada-Lobato, E., Gnanasegaran, G., Kuwert, T., la Fougère, C., Mariani, G., Massalha, S., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04404-6 · Cited by 225
Diagnostic management of acute deep vein thrombosis and pulmonary embolism
Huisman, M. V., & Klok, F. A. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12124 · Cited by 176
MRI of the lung – state of the art
Wielputz, M., & Kauczor, H.-U. (2011) · Diagnostic and Interventional Radiology · doi:10.4261/1305-3825.dir.5365-11.0 · Cited by 161
“center PIOPED III study demonstrated a sensitivity and specificity for acute PE of 78% and 99%, respectively (36).”
Background
Metadata
- Authors
- Stein, P. D., Chenevert, T. L., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Jablonski, K. A., Leeper, K. V., Naidich, D. P., Sak, D. J., Sostman, H. D., Tapson, V. F., Weg, J. G., Woodard, P. K., & for the PIOPED III (Prospective Investigation of Pulmonary Embolism Diagnosis III) Investigators*
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2010-04-06
- Volume
- 152
- Issue
- 7
- Pages
- 434-443
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2129444859
- Cited by
- 392
- References
- 23
- FWCI
- 32.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.