The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography
Open accessAbstract
BACKGROUND: A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available. PURPOSE: To summarize current evidence about the ability of low-dose coronary CT angiography to rule out coronary artery disease (CAD) in symptomatic adults. DATA SOURCES: Online databases, including MEDLINE, EMBASE, and the Cochrane Library, from inception through 31 October 2010; abstract databases; gray literature; reference lists of identified articles; and experts. No language restrictions were applied. STUDY SELECTION: All investigators screened and selected studies that compared prospective electrocardiography-gated coronary CT angiography with catheter coronary angiography (the reference standard) in symptomatic patients with suspected CAD. DATA EXTRACTION: Two investigators independently extracted patient and study protocol characteristics and rated methodological quality; differences were resolved by consensus or by a third reader. Multivariate random-effects models were used to obtain pooled estimates. DATA SYNTHESIS: 16 studies, comprising 960 patients, were found (7 studies of single-source, 64-slice CT; 4 of dual-source, 64-slice CT; 2 of single-source, 320-slice CT; 1 dual-source, 128-slice CT; 1 of single-source, 128-slice CT; and 1 of single-source, 256-slice CT). On average, 2.4% of the coronary arterial segments were of nondiagnostic image quality, and 1 or more segments were nondiagnostic in 9.5% of the patients. The patient-level sensitivity and specificity of CT angiography were 1.00 (95% CI, 0.98 to 1.00) and 0.89 (CI, 0.85 to 0.92), respectively. The pooled vessel- and segment-level estimates showed lower sensitivity and higher specificity than the patient-level estimates. Statistically significant heterogeneity was found between studies for vessel- and segment-level estimates, which seemed to be associated with body mass index and prevalence of CAD but not with CT scanner characteristics. LIMITATIONS: The small number of studies, half of which were from a single tertiary center, limits generalizability. The potential harms of the imaging tests were not well-evaluated. CONCLUSION: Early evidence suggests that low-dose coronary CT angiography matches the sensitivity of catheter-based angiography, has low radiation exposure, and is a potentially valid alternative to catheter angiography for triaging symptomatic patients with a clinical suspicion of CAD. PRIMARY FUNDING SOURCE: None.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Systematic Review: Why sources of heterogeneity in meta-analysis should be investigated
Thompson, S. G. (1994) · BMJ · doi:10.1136/bmj.309.6965.1351 · Cited by 1,017
Cited by
Coronary CT Angiography versus Standard Evaluation in Acute Chest Pain
Hoffmann, U., Truong, Q. A., Schoenfeld, D. A., Chou, E. T., Woodard, P. K., Nagurney, J. T., Pope, J. H., Hauser, T. H., White, C. S., Weiner, S. G., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1201161 · Cited by 903
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.005 · Cited by 484
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler-Klein, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet123 · Cited by 353
Genders, T. S. S., Steyerberg, E. W., Hunink, M. G. M., Nieman, K., Galema, T. W., Mollet, N. R., Feyter, P. J. D., Krestin, G. P., Alkadhi, H., Leschka, S., et al. (2012) · BMJ · doi:10.1136/bmj.e3485 · Cited by 314
Self-citation
Metadata
- Authors
- von Ballmoos, M. W., Haring, B., Juillerat, P., & Alkadhi, H.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-03-15
- Volume
- 154
- Issue
- 6
- Pages
- 413-420
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2000682478
- Cited by
- 169
- References
- 5
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography. https://app.cochat.ai/papers/10.7326/0003-4819-154-6-201103150-00007
- The paper
- von Ballmoos, M. W., Haring, B., Juillerat, P., & Alkadhi, H. (2011). Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-154-6-201103150-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.