Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available. PURPOSE: To summarize current evidence about the ability of low-dose coronary CT angiography to rule out coronary artery disease (CAD) in symptomatic adults. DATA SOURCES: Online databases, including MEDLINE, EMBASE, and the Cochrane Library, from inception through 31 October 2010; abstract databases; gray literature; reference lists of identified articles; and experts. No language restrictions were applied. STUDY SELECTION: All investigators screened and selected studies that compared prospective electrocardiography-gated coronary CT angiography with catheter coronary angiography (the reference standard) in symptomatic patients with suspected CAD. DATA EXTRACTION: Two investigators independently extracted patient and study protocol characteristics and rated methodological quality; differences were resolved by consensus or by a third reader. Multivariate random-effects models were used to obtain pooled estimates. DATA SYNTHESIS: 16 studies, comprising 960 patients, were found (7 studies of single-source, 64-slice CT; 4 of dual-source, 64-slice CT; 2 of single-source, 320-slice CT; 1 dual-source, 128-slice CT; 1 of single-source, 128-slice CT; and 1 of single-source, 256-slice CT). On average, 2.4% of the coronary arterial segments were of nondiagnostic image quality, and 1 or more segments were nondiagnostic in 9.5% of the patients. The patient-level sensitivity and specificity of CT angiography were 1.00 (95% CI, 0.98 to 1.00) and 0.89 (CI, 0.85 to 0.92), respectively. The pooled vessel- and segment-level estimates showed lower sensitivity and higher specificity than the patient-level estimates. Statistically significant heterogeneity was found between studies for vessel- and segment-level estimates, which seemed to be associated with body mass index and prevalence of CAD but not with CT scanner characteristics. LIMITATIONS: The small number of studies, half of which were from a single tertiary center, limits generalizability. The potential harms of the imaging tests were not well-evaluated. CONCLUSION: Early evidence suggests that low-dose coronary CT angiography matches the sensitivity of catheter-based angiography, has low radiation exposure, and is a potentially valid alternative to catheter angiography for triaging symptomatic patients with a clinical suspicion of CAD. PRIMARY FUNDING SOURCE: None.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
Brenner, D. J., Doll, R., Goodhead, D. T., Hall, E. J., Land, C. E., Little, J. B., Lubin, J. H., Preston, D. L., Preston, R. J., Puskin, J. S., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2235592100 · Cited by 1,765
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Systematic Review: Why sources of heterogeneity in meta-analysis should be investigated
Thompson, S. G. (1994) · BMJ · doi:10.1136/bmj.309.6965.1351 · Cited by 1,017
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
NCRP report no. 93: Ionizing radiation exposure of the population of the United States
Eckelman, W. C. (1988) · International Journal of Radiation Applications and Instrumentation. Part B. Nuclear Medicine and Biology · doi:10.1016/0883-2897(88)90020-7 · Cited by 755
A unification of models for meta-analysis of diagnostic accuracy studies
Harbord, R. M., Deeks, J. J., Egger, M., Whiting, P., & Sterne, J. A. C. (2007) · Biostatistics · doi:10.1093/biostatistics/kxl004 · Cited by 751
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Mowatt, G., Cook, J. A., Hillis, G. S., Walker, S., Fraser, C., Jia, X., & Waugh, N. (2008) · Heart · doi:10.1136/hrt.2008.145292 · Cited by 484
Vanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., & Hunink, M. G. M. (2007) · Radiology · doi:10.1148/radiol.2442061218 · Cited by 442
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B. (2009) · Circulation · doi:10.1161/circulationaha.109.859280 · Cited by 328
Hirai, N., Horiguchi, J., Fujioka, C., Kiguchi, M., Yamamoto, H., Matsuura, N., Kitagawa, T., Teragawa, H., Kohno, N., & Ito, K. (2008) · Radiology · doi:10.1148/radiol.2482071804 · Cited by 293
Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance
Scheffel, H., Alkadhi, H., Leschka, S., Plass, A., Desbiolles, L., Guber, I., Krauss, T., Gruenenfelder, J., Genoni, M., Luescher, T. F., et al. (2008) · Heart · doi:10.1136/hrt.2008.149971 · Cited by 291 · cited 1×
“Eight studies on low-dose coronary CT angiography were published by 2 groups of investigators ([24, 27, 33, 34, 38] and [26, 29, 32]) at the same academic tertiary care center.”
BackgroundSelf-citationSchuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-3-201002020-00008 · Cited by 265
Bivariate random-effects meta-analysis and the estimation of between-study correlation
Riley, R. D., Abrams, K. R., Sutton, A. J., Lambert, P. C., & Thompson, J. R. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-3 · Cited by 244
Step‐and‐shoot data acquisition and reconstruction for cardiac x‐ray computed tomography
Hsieh, J., Londt, J., Vass, M., Li, J., Tang, X., & Okerlund, D. (2006) · Medical Physics · doi:10.1118/1.2361078 · Cited by 228 · cited 1×
“Study Selection Studies were screened and selected by all investigators on the basis of a priori criteria: Data had to be acquired by a multidetector row CT scanner with at least 64 detectors (the technique was introduced for coronary angiography purposes on this CT scanner generation [8]) by using a low-radiation-dos…”
MethodMeta-Analysis of Diagnostic and Screening Test Accuracy Evaluations: Methodologic Primer
Gatsonis, C., & Paliwal, P. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.06.0226 · Cited by 215
de Graaf, F. R., Schuijf, J. D., van Velzen, J. E., Kroft, L. J., de Roos, A., Reiber, J. H. C., Boersma, E., Schalij, M. J., Spano, F., Jukema, J. W., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp571 · Cited by 200
Maruyama, T., Takada, M., Hasuike, T., Yoshikawa, A., Namimatsu, E., & Yoshizumi, T. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.048 · Cited by 175 · cited 3×
“…0.6 0.8 1.0 0.0 0.2 0.4 0.6 0.8 1.0 Segment level Alkadhi et al, 2010 (38) Arnoldi et al, 2010 (35) Carrascosa et al, 2010 (37) de Graaf et al, 2010 (31) Dewey et al, 2009 (30) Herzog et al, 2008 (26) Herzog et al, 2009 (29) Maruyama et al, 2008 (25) Pontone et al, 2009 (28) Scheffel et al, 2008…”
InfluentialAlkadhi, H., Stolzmann, P., Desbiolles, L., Baumueller, S., Goetti, R., Plass, A., Scheffel, H., Feuchtner, G., Falk, V., Marincek, B., et al. (2010) · Heart · doi:10.1136/hrt.2009.189100 · Cited by 173 · cited 1×
“Eight studies on low-dose coronary CT angiography were published by 2 groups of investigators ([24, 27, 33, 34, 38] and [26, 29, 32]) at the same academic tertiary care center.”
BackgroundSelf-citationHerzog, B. A., Husmann, L., Burkhard, N., Gaemperli, O., Valenta, I., Tatsugami, F., Wyss, C. A., Landmesser, U., & Kaufmann, P. A. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn485 · Cited by 128 · cited 6×
“…(24) Scheffel et al, 2010 (34) Stolzmann et al, 2008 (27) Stolzmann et al, 2010 (33) Vessel level Alkadhi et al, 2010 (38) Arnoldi et al, 2010 (35) Carrascosa et al, 2010 (37) de Graaf et al, 2010 (31) Dewey et al, 2009 (30) Herzog et al, 2008 (26) Herzog et al, 2009 (29) Husmann et al, 2010…”
BackgroundInfluentialDiagnostic Accuracy of Coronary Computed Tomography Angiography
Pontone, G., Andreini, D., Bartorelli, A. L., Cortinovis, S., Mushtaq, S., Bertella, E., Annoni, A. D., Formenti, A., Nobili, E., Trabattoni, D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.027 · Cited by 122 · cited 5×
“…2010 (33) Vessel level Alkadhi et al, 2010 (38) Arnoldi et al, 2010 (35) Carrascosa et al, 2010 (37) de Graaf et al, 2010 (31) Dewey et al, 2009 (30) Herzog et al, 2008 (26) Herzog et al, 2009 (29) Husmann et al, 2010 (32) Pontone et al, 2009 (28) Scheffel et al, 2008 (24) Scheffel et al, 2010…”
InfluentialHerzog, B. A., Wyss, C. A., Husmann, L., Gaemperli, O., Valenta, I., Treyer, V., Landmesser, U., & Kaufmann, P. A. (2009) · Heart · doi:10.1136/hrt.2008.162420 · Cited by 97 · cited 1×
“Eight studies on low-dose coronary CT angiography were published by 2 groups of investigators ([24, 27, 33, 34, 38] and [26, 29, 32]) at the same academic tertiary care center.”
BackgroundStolzmann, P., Goetti, R. P., Baumueller, S., Plass, A., Falk, V., Scheffel, H., Feuchtner, G. M., Marinček, B., Alkadhi, H., & Leschka, S. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.12.016 · Cited by 53 · cited 6×
“…Graaf et al, 2010 (31) Dewey et al, 2009 (30) Herzog et al, 2008 (26) Herzog et al, 2009 (29) Maruyama et al, 2008 (25) Pontone et al, 2009 (28) Scheffel et al, 2008 (24) Scheffel et al, 2010 (34) Stolzmann et al, 2008 (27) Stolzmann et al, 2010 (33) Vessel level Alkadhi et al, 2010 (38) Arnoldi…”
BackgroundInfluentialSelf-citationCarrascosa, P., Capuñay, C., Deviggiano, A., Goldsmit, A., Tajer, C. D., Bettinotti, M. O., Carrascosa, J. M., Ivanc, T. B., Fallahi, A., & García, M. J. (2010) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2010.04.001 · Cited by 34 · cited 8×
“…(29) Maruyama et al, 2008 (25) Pontone et al, 2009 (28) Scheffel et al, 2008 (24) Scheffel et al, 2010 (34) Stolzmann et al, 2008 (27) Stolzmann et al, 2010 (33) Vessel level Alkadhi et al, 2010 (38) Arnoldi et al, 2010 (35) Carrascosa et al, 2010 (37) de Graaf et al, 2010 (31) Dewey et al, 2009…”
Influential
Cited by
Coronary CT Angiography versus Standard Evaluation in Acute Chest Pain
Hoffmann, U., Truong, Q. A., Schoenfeld, D. A., Chou, E. T., Woodard, P. K., Nagurney, J. T., Pope, J. H., Hauser, T. H., White, C. S., Weiner, S. G., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1201161 · Cited by 903
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.005 · Cited by 484
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler-Klein, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet123 · Cited by 353
Genders, T. S. S., Steyerberg, E. W., Hunink, M. G. M., Nieman, K., Galema, T. W., Mollet, N. R., Feyter, P. J. D., Krestin, G. P., Alkadhi, H., Leschka, S., et al. (2012) · BMJ · doi:10.1136/bmj.e3485 · Cited by 314
Self-citation
Metadata
- Authors
- von Ballmoos, M. W., Haring, B., Juillerat, P., & Alkadhi, H.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-03-15
- Volume
- 154
- Issue
- 6
- Pages
- 413-420
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2000682478
- Cited by
- 169
- References
- 38
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.