Systematic Review: Benefits and Harms of In-Hospital Use of Recombinant Factor VIIa for Off-Label Indications
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Recombinant factor VIIa (rFVIIa), a hemostatic agent approved for hemophilia, is increasingly used for off-label indications. PURPOSE: To evaluate the benefits and harms of rFVIIa use for 5 off-label, in-hospital indications: intracranial hemorrhage, cardiac surgery, trauma, liver transplantation, and prostatectomy. DATA SOURCES: Ten databases (including PubMed, EMBASE, and the Cochrane Library) queried from inception through December 2010. Articles published in English were analyzed. STUDY SELECTION: Two reviewers independently screened titles and abstracts to identify clinical use of rFVIIa for the selected indications and identified all randomized, controlled trials (RCTs) and observational studies for full-text review. DATA EXTRACTION: Two reviewers independently assessed study characteristics and rated study quality and indication-wide strength of evidence. DATA SYNTHESIS: 16 RCTs, 26 comparative observational studies, and 22 noncomparative observational studies met inclusion criteria. Identified comparators were limited to placebo (RCTs) or usual care (observational studies). For intracranial hemorrhage, mortality was not improved with rFVIIa use across a range of doses. Arterial thromboembolism was increased with medium-dose rFVIIa use (risk difference [RD], 0.03 [95% CI, 0.01 to 0.06]) and high-dose rFVIIa use (RD, 0.06 [CI, 0.01 to 0.11]). For adult cardiac surgery, there was no mortality difference, but there was an increased risk for thromboembolism (RD, 0.05 [CI, 0.01 to 0.10]) with rFVIIa. For body trauma, there were no differences in mortality or thromboembolism, but there was a reduced risk for the acute respiratory distress syndrome (RD, -0.05 [CI, -0.02 to -0.08]). Mortality was higher in observational studies than in RCTs. LIMITATIONS: The amount and strength of evidence were low for most outcomes and indications. Publication bias could not be excluded. CONCLUSION: Limited available evidence for 5 off-label indications suggests no mortality reduction with rFVIIa use. For some indications, it increases thromboembolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., Vandenbroucke, J. P., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040296 · Cited by 23,020
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04337-3 · Cited by 5,373
Moher, D., Pham, B., Jones, A., Cook, D. J., Jadad, A. R., Moher, M., Tugwell, P., & Klassen, T. P. (1998) · The Lancet · doi:10.1016/s0140-6736(98)01085-x · Cited by 3,560
Evaluating non-randomised intervention studies
Deeks, J., Dinnes, J., D'Amico, R., Sowden, A., Sakarovitch, C., Song, F., Petticrew, M., & Altman, D. (2003) · Health Technology Assessment · doi:10.3310/hta7270 · Cited by 2,907
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
Sanderson, S., Tatt, I. D., & Higgins, J. P. (2007) · International Journal of Epidemiology · doi:10.1093/ije/dym018 · Cited by 1,531
Moher, D., Schulz, K. F., Altman, D. G., & for the CONSORT Group* (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-8-200104170-00011 · Cited by 1,426
Efficacy and Safety of Recombinant Activated Factor VII for Acute Intracerebral Hemorrhage
Mayer, S. A., Brun, N. C., Begtrup, K., Broderick, J., Davis, S., Diringer, M. N., Skolnick, B. E., & Steiner, T. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0707534 · Cited by 1,255 · cited 3×
“…(Reference) rFVIIa Events/Total, n/n Usual Care Events/Total, n/n ICH, low dose Mayer et al, 2005 (30) Mayer et al, 2005 (31) Mayer et al, 2006 (32) Mayer et al, 2008 (33) Combined ICH, medium dose Mayer et al, 2005 (30) Mayer et al, 2005 (31) Mayer et al, 2006 (32) Mayer et al, 2008 (33) Combined…”
Owens, D. K., Lohr, K. N., Atkins, D., Treadwell, J. R., Reston, J. T., Bass, E. B., Chang, S., & Helfand, M. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.03.009 · Cited by 513
Self-citation
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Authors/Task Force Members, Hamm, C. W., Bassand, J.-P., Agewall, S., Bax, J., Boersma, E., Bueno, H., Caso, P., Dudek, D., Gielen, S., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr236 · Cited by 3,080
Hamm, C. W., Bassand, J.-P., Agewall, S., Bax, J., Boersma, E., Bueno, H., Caso, P., Dudek, D., Gielen, S., Huber, K., et al. (2012) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2011.11.006 · Cited by 1,068
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Steiner, T., Salman, R. A.-S., Beer, R., Christensen, H., Cordonnier, C., Csiba, L., Forsting, M., Harnof, S., Klijn, C. J. M., Krieger, D., et al. (2014) · International Journal of Stroke · doi:10.1111/ijs.12309 · Cited by 813
Metadata
- Authors
- Yank, V., Tuohy, C. V., Logan, A. C., Bravata, D. M., Staudenmayer, K., Eisenhut, R., Sundaram, V., McMahon, D., Olkin, I., McDonald, K. M., Owens, D. K., & Stafford, R. S.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-04-19
- Volume
- 154
- Issue
- 8
- Pages
- 529-540
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2142624326
- Cited by
- 240
- References
- 10
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic Review: Benefits and Harms of In-Hospital Use of Recombinant Factor VIIa for Off-Label Indications. https://app.cochat.ai/papers/10.7326/0003-4819-154-8-201104190-00004
- The paper
- Yank, V., Tuohy, C. V., Logan, A. C., Bravata, D. M., Staudenmayer, K., Eisenhut, R., Sundaram, V., McMahon, D., Olkin, I., McDonald, K. M., Owens, D. K., & Stafford, R. S. (2011). Systematic Review: Benefits and Harms of In-Hospital Use of Recombinant Factor VIIa for Off-Label Indications. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-154-8-201104190-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.