QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 12,501–12,600 of 14,770
Arredondo, J. (2023) · Depósito Académico Digital Universidad de Navarra (University of Navarra) · doi:10.15581/10171/66681
Li, L., Zhao, C., Deng, C., Zhang, Y., Wang, Q., & Kang, D. (2023) · Research Square · doi:10.21203/rs.3.rs-3084856/v1
Islam, N., Al-Ghita, M. K., Ebrahimzadeh, S., Dawit, H., Prager, R. T., Alvarez, G. G., Cohen, J. F., Korevaar, D. A., Deeks, J. J., Verbakel, J. Y. J., et al. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015318
Self-citationAdvanced Research in Pediatric Radiology and Nuclear Medicine
Ng, C. K. C. (2023) · MDPI eBooks · doi:10.3390/books978-3-0365-7958-0
Clarke, M. A., & Wentzensen, N. (2023) · International Journal of Cancer · doi:10.1002/ijc.34642
“To address these issues, we performed a quality assessment of all reviewed studies using the QUADAS-2 measure, which evaluates potential biases related to patient selection, the index tests and reference standards, as well as flow and timing.(4) A quality assessment serves to not only allow for bias and applicability…”
Quality of athlete screening for high‐risk cardiovascular conditions—A systematic review
Panhuyzen-Goedkoop, N. M., Verbeek, A. L. M., Goedkoop, R. J., Malekzadeh, A., Wilde, A. A. M., Peters, R. J. G., & Jorstad, H. T. (2023) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14446
García‐Perdomo, H. A., & Leal, F. R. P. (2023) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.23736/s1825-859x.23.00194-9
Balachandran, K., Rahman, M. A., Karsani, S. A., & Ramli, R. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4519795
Knez, N., Kroflin, K., & Fraga, G. R. (2023) · Journal of Cutaneous Pathology · doi:10.1111/cup.14504
Pursuing quality education in Physical and Rehabilitation Medicine
(2023) · Frontiers research topics · doi:10.3389/978-2-8325-3181-5
Chen, Y., Wang, J., & Niu, T. (2023) · Research Square · doi:10.21203/rs.3.rs-3193455/v1
190 días de pentalogía de cantrell: reporte de caso y revisión de tema
Acosta, J. A. R., & Gutiérrez, E. (2023) · South Florida Journal of Development · doi:10.46932/sfjdv4n5-012
Desafios e Tendências na Predição de Sepse
Silva, L. G., Jr., Andrade, R. M. C., & Celestino, J. (2023) · doi:10.5753/sbcas.2023.230163
“…(GRADE) [Schünemann 2013], a ferramenta Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) para avaliar o risco de viés e a aplicabilidade de estudos primários de precisão diagnóstica e a Area Under the Curve of the Receiver Operating (AUROC) como métrica de performance [Whiting 2011].”
Wang, Y., Ren, Y., Zhang, Y., Liang, X., & Zhang, R. (2023) · Authorea · doi:10.22541/au.169277572.26230869/v1 · Cited by 1
Shazam, H., & Butt, Y. B. (2023) · Khyber Medical University Journal · doi:10.35845/kmuj.2023.22498
Clinical application of diagnostic techniques for tissue perfusion measurements
Kleiss, S. F. (2023) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.763216765
Enfoque y alcance de la revista
Alvarez-López, F. (2023) · Archivos de Medicina (Manizales) · doi:10.30554/archmed.23.1.4947.2023
Alvarez-López, F. (2023) · Archivos de Medicina (Manizales) · doi:10.30554/archmed.23.1.4945.2023
Anemia Risk Factor Model In Pregnant Women
Katili, S. A., Kadir, S., Boekoesoe, L., & Irwan, I. (2023) · INTERNATIONAL JOURNAL OF HEALTH & MEDICAL RESEARCH · doi:10.58806/ijhmr.2023.v2i9n01
Qi, X., Liu, C., You, H., Zeng, Q., Wong, Y. J., Wang, B., Grgurević, I., Dong, B., Gou, W., Ju, S., et al. (2023) · doi:10.22541/au.169450109.98248913/v1
Sadler, L., Jones, H., Whiting, P., et al. (2023) · University of Warwick · doi:10.3310/nihropenres.14541.r29471
Sadler, L., Jones, H., Whiting, P., et al. (2023) · University of Oxford · doi:10.3310/nihropenres.14541.r30210
Aninworie, A. I. (2023) · INTERNATIONAL JOURNAL OF HEALTH & MEDICAL RESEARCH · doi:10.58806/ijhmr.2023.v2i9n05 · Cited by 1
Wang, R., Guo, L., Pan, L., Tian, R., & Shen, G. (2023) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-23-477
Late metabolic consequences of childhood cancer
Pluimakers, V. G. (2023) · Utrecht University Repository (Utrecht University) · doi:10.33540/1778
Diagnosis accuracy of Raman spectroscopy in the diagnosis of tuberculosis: a meta-analysisPreprint
Cheng, Z., Ma, R., Yu, Z., Wu, J., Sun, Y., Wang, Q., Li, T., Zhao, J., & Wang, S. (2023) · Research Square · doi:10.21203/rs.3.rs-3363826/v1
Comparison of Diagnostic Accuracies of Frailty Assessment Tools for Frailty in Older PeoplePreprint
Li, L., Chongyang, Z., Cong, D., Yu-hui, Z., Qin, W., & Deying, K. (2023) · Research Square · doi:10.21203/rs.3.rs-3333698/v1
Reviews in psychiatry 2022: Personality disorders
(2023) · Frontiers research topics · doi:10.3389/978-2-8325-3521-9
Necrotizing pancreatitis: Off the beaten path
Timmerhuis, H. C. (2023) · Utrecht University Repository (Utrecht University) · doi:10.33540/1976
Rohde, J. F., Campbell, J. W., Barbera, J. P., Taylor, E., Ramachandra, A., Gegg, C. A., Scherer, A. G., & Piatt, J. H. (2023) · BMC Pediatrics · doi:10.1186/s12887-023-04379-2
Arachchige, A. S. P. M. (2023) · medRxiv · doi:10.1101/2023.11.12.23298426
Assessment of thoracic tumors by FAPI PETCT: a systematic evaluation and meta-analysisPreprint
Wang, T., Huang, D., Liao, S., Wang, Y., Deng, H., Zhong, H., Wu, J., Yang, Q., Yang, L., Pang, H., et al. (2023) · Research Square · doi:10.21203/rs.3.rs-3629640/v1
Costa, F. B. D., Junior, J. B., Vieira, L., & Giorgetti, L. (2023) · Research Society and Development · doi:10.33448/rsd-v12i13.44144
Dai, L., Guo, W., Xuan, X.-W., Meng, X., Wang, Y., Chai, H.-X., Chen, J., Chen, J.-M., & Pu, J. (2023) · All Life · doi:10.1080/26895293.2023.2288534
de Oliveira, I. B. D. (2023) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.9.2023.tde-13112023-164639
Azad, S., & Kotwal, A. (2023) · Clinical Thyroidology · doi:10.1089/ct.2023;35.508-511
Liberato, W. F., Miyahira, K. M., Ferreira, D. M. T. P., Caldo-Teixeira, Â. S., Rodrigues, S. A., Maia, L. C., & Cavalcante, L. M. A. (2023) · Revista da Faculdade Paulo Picanço · doi:10.59483/rfpp.v3n4.95
The Use of Artificial Intelligence in Dental Imaging for Endodontics: A Systematic ReviewPreprint
Pereira, N. S., Ünsal, R. B. K., Arsiwala-Scheppach, L. T., Badr, Z., Hamdan, M. H., Tryfonos, O., Rokhshad, R., Karteva, T., & dos Santos, M. F. H. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4667813 · Cited by 1
Ali, A. (2023) · Asian Journal of Medicine and Biomedicine · doi:10.37231/ajmb.2023.1.s.670
Valenzi, N. (2024) · Western Journal of Emergency Medicine · doi:10.5811/westjem.62878
Shakir, M., Irshad, H. A., Lodhi, B. A., Jehanzeb, H., Shaikh, T., & Enam, S. A. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.01.023
Predictive Value of AMH on Spontaneous Abortion: Systematic Review and Meta-analysisPreprint
Yao, R., Liu, D., Liu, C., Han, X., & Feng, X. (2024) · Research Square · doi:10.21203/rs.3.rs-3827159/v1
Cortes-Quiroz, J. C., Bernal, J. A., Rosas, J., & Ena, J. (2024) · Reumatología Clínica · doi:10.1016/j.reuma.2023.11.003
Zhou, M. S., Xu, C. Y., Dang, Y., Li, P., Xu, L. X., Wu, J., & Shi, H. Y. (2024) · Research Square · doi:10.21203/rs.3.rs-3863127/v1
Potdukhe, S., Iyer, J., & Nadgere, J. B. (2024) · The Journal of Indian Prosthodontic Society · doi:10.4103/jips.jips_382_23 · Cited by 1
Measuring the accuracy of clinical findings
Sox, H. C., Higgins, M. C., Owens, D. K., & Sanders, G. D. (2024) · Medical Decision Making · doi:10.1002/9781119627876.ch5
AI FOR LITTLE EYES: A SYSTEMATIC REVIEW OF DEEP LEARNING IN EVALUATING PEDIATRIC CATARACT
Tjoeng, E., & Annisa, D. N. (2024) · Ophthalmologica Indonesiana · doi:10.35749/1ydhv934
Equipment and advances for measuring fatigue in office settings: systematic review protocol
Pezeshki, S. I., Guedes, J. C., & Baptista, J. S. (2024) · International Journal of Occupational and Environmental Safety · doi:10.24840/2184-0954_008-001_002233
Ruiz‐Garcia, R., Matías‐Guiu, J. A., Grasso, S. M., Ruiz-Rodríguez, O., Medina-Rioja, R., Finger, E. C., & Pérez‐Neri, I. (2023) · Archivos de Neurociencias · doi:10.31157/an.v1iinpress.636
Uncertain Diagnostic Accuracy of Self-Monitoring Vision at Home
Gidman, E., & Reeves, B. C. (2024) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2023.6717
Hosseini, M., Hartoonian, S., Mahdian, M., Khadivi, G., & Ahsaie, M. G. (2024) · Research Square · doi:10.21203/rs.3.rs-3958673/v1
Principles of Evidence‐Based Dermatology
Bigby, M. E., & Williams, H. C. (2024) · Wiley eBooks · doi:10.1002/9781119709268.rook017
Chen, Y., Zhu, W., Yi, Y., Cao, H., Chen, F., & Zhu, Q. (2024) · Medical Ultrasonography · doi:10.11152/mu-4334
Andrade, L. J. D. O., de Oliveira, G. C. M., França, C. S., Bittencourt, A. M. V., Nascimento, G. P., Silva, C. P., & de Oliveira, L. M. (2024) · Research Square · doi:10.21203/rs.3.rs-3995559/v1
Evaluating the Safety and Efficacy of Topical Insulin for Ocular Disease: A Systematic ReviewPreprint
Andrade, L. J. D. O., de Oliveira, G. C. M., França, C. S., & de Oliveira, L. M. (2024) · medRxiv · doi:10.1101/2024.02.24.24303321 · Cited by 2
A Meta-Analysis of Predictive Value of Blood Biomarkers in Gestational Trophoblastic Neoplasia
Guo, Y. C., Zhang, T., He, X., Xu, H., Wang, L., Zhou, W., Gao, L., & An, R. (2024) · Future Oncology · doi:10.2217/fon-2023-0919
Zhang, Y., Zhu, D., & Feng, R. (2024) · International Journal of Radiation Research · doi:10.61186/ijrr.22.1.27
Preoperative diagnostic criteria for scleroatrophic gallbladder: A systematic review protocol
Melo, R. B., Fernandes, C., Aguiar, A., López‐Ben, S., Guimarães, L., & Serralheiro, P. A. (2024) · PLoS ONE · doi:10.1371/journal.pone.0300336
LUNG ULTRASOUND: AN EFFICIENT AND ACCURATE DIAGNOSTIC TOOL IN CHILDHOOD PNEUMONIA. A META ANALYSIS.Preprint
lu, X., Jin, Y., Li, Y., Weng, L., & Li, H. (2024) · doi:10.22541/au.170666010.03535009/v1
Emergency Chest Ultrasound and Traumatic Pneumothorax. An Updated Meta-AnalysisPreprint
Zhou, Y., Tian, H., Zhang, T., Rastogi, S., & Choudhury, R. (2024) · doi:10.22541/au.170666118.89080179/v1
Cortes-Quiroz, J. C., Bernal, J. A., Rosas, J., & Ena, J. (2024) · Reumatología Clínica (English Edition) · doi:10.1016/j.reumae.2024.02.002
Izzo, P., Izzo, S., Izzo, L., Cello, P. D., Meloni, P., Messineo, D., Lauro, A., Polistena, A., Molle, M., & Intinis, C. D. (2024) · Preprints.org · doi:10.20944/preprints202403.0839.v1
Yaputra, R. M., & Permana, A. A. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4757861
Lourenço, M., Arrufat, T., Satorres-Pérez, E., Maderuelo, S., Álamo, B. N.-D., Guerriero, S., Orozco, R., & Alcázar, J. L. (2024) · Applied Sciences · doi:10.3390/app14072998 · Cited by 1
“The quality assessment of the studies included in the meta-analysis was conducted using the tool provided by the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [46].”
Olivier, J. (2021) · theses.fr (ABES) · doi:10.70675/d3b23c9ez98eaz45cdza1bez189d21bbf6a6
Bal, A. K., Gupta, M., Rout, D. R. R., Mohanty, S., Behera, L., Mishra, S. C., & Bal, B. (2024) · SSR Institute of International Journal of Life Sciences · doi:10.21276/ssr-iijls.2024.10.2.21
Su, S., Yang, F., Zhong, L., & Pang, L. (2021) · Figshare · doi:10.6084/m9.figshare.17110751
Cao, F., Hu, Y., Chen, Z., Han, W., Lu, W., Xu, J., Ding, H.-Z., & Shen, X. (2021) · Figshare · doi:10.6084/m9.figshare.14329363
Shen, H., Jin, Y., Zhao, H., Wu, M., Zhang, K., Wei, Z., Wang, X., Wang, Z., Li, Y., Yang, F., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22616578
Su, S., Yang, F., Zhong, L., & Pang, L. (2021) · Figshare · doi:10.6084/m9.figshare.17110748
Lin, Q., Zhang, C., Weng, H., Lin, Y., Lin, Y., & Ruan, Z. (2023) · Figshare · doi:10.6084/m9.figshare.24124005
Lin, Y., Rong, J., & Zhang, Z. (2021) · Figshare · doi:10.6084/m9.figshare.14670474
Zhong, R., Gao, R., Fu, W., Li, C., Huo, Z., Gao, Y., Lu, Y., Li, F., Ge, F., Tu, H., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22815156
Zhong, R., Gao, R., Fu, W., Li, C., Huo, Z., Gao, Y., Lu, Y., Li, F., Ge, F., Tu, H., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22815153
Jia, E., Ren, N., Shi, X., Zhang, R., Yu, H., Yu, F., Qin, S., & Xue, J. (2022) · Figshare · doi:10.6084/m9.figshare.19845829
Lin, Q., Zhang, C., Weng, H., Lin, Y., Lin, Y., & Ruan, Z. (2023) · Figshare · doi:10.6084/m9.figshare.24124002
Xing, J., Li, J., Yan, Z., Li, Y., Liu, X., He, L., Xu, T. S., Wang, C., Zhao, L., & Ke, J. (2022) · Figshare · doi:10.6084/m9.figshare.17982257
Risk of Bias Assessment and Risk Minimisation Strategies in COVID-19 Diagnostic Test Accuracy Study
Shukri, M. I. M., Zainal, N. Z., & Azman, A. Z. F. (2024) · Malaysian Journal of Medicine and Health Sciences · doi:10.47836/mjmhs.20.1.43
Zhong, R., Gao, R., Fu, W., Li, C., Huo, Z., Gao, Y., Lu, Y., Li, F., Ge, F., Tu, H., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22815144
Zhu, T., Liao, M., Huang, M., & Xiao, F. (2024) · Clinical and Translational Imaging · doi:10.1007/s40336-024-00635-2
“Two researchers used the Quality Assessment of Diagnostic Performance Accuracy Studies-2 (QUADAS-2) method to evaluate the included studies’ quality independently [12].”
Watson, S. L., Jiang, I., Durakovic, E., & Kandel, H. (2024) · Research Square · doi:10.21203/rs.3.rs-3993950/v1
The Effect of Lefort I Impaction Osteotomy on Upper Airway and Nasal Breathing: Systematic ReviewPreprint
Neani, H., Tabchi, Y., Elhaddaoui, R., & Zaoui, F. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4805655
Andrade, L. J. D. O., de Oliveira, G. C. M., Bittencourt, A. M. V., David, T. M., Rocha, R. M., & de Oliveira, L. M. (2024) · Research Square · doi:10.21203/rs.3.rs-4356084/v1
ten Hove, D. (2024) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.987817381
Suboptimal reporting practices in biomedical research
Ghannad, M. (2021) · theses.fr (ABES) · doi:10.70675/a6b7cb44z6076z445fz80f4z8d9c1b47b38a
Willems, S. A., van der Vorst, J. R., & Brouwers, J. J. W. M. (2024) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2024.01.020
Martins, F. B. (2023) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.23.2023.tde-09052024-095112
Diagnostic Implications of Salivary Biomarkers in COVID-19: A Systematic Review and Meta-Analysis
Bhatnagar, S., Dhokar, A., & Kamble, T. (2023) · Journal of Indian Academy of Oral Medicine and Radiology · doi:10.4103/jiaomr.jiaomr_222_23
Postmortem Gone Astray—A Systematic Review and Meta-Analysis
Šoša, I., & Perković, M. (2024) · Forensic Sciences · doi:10.3390/forensicsci4020017
Sadler, L., Jones, H., Whiting, P., et al. (2024) · University of Warwick · doi:10.3310/nihropenres.14733.r31662
Soltanali, Z., Pourrahim, A., Williams, C. R.-A., Ekvan, M. H., Ahmadi, I., & Raiesi, O. (2024) · Research Square · doi:10.21203/rs.3.rs-4494281/v1
Alves, M. R., Saturnino, S. F., Zen, A. B., Silveira, D. G. A., & Diegoli, H. (2024) · Critical Care Science · doi:10.62675/2965-2774.20240196-pt
How Do We Assess Controversies Using Evidence-Based Radiology?
Pandharipande, P. V., & Kang, S. K. (2024) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2024.05.002
Mansoor, M., Shafiq, M. H., Imran, M., Mushtaq, F., Iftikhar, S., & Shafiq, F. (2024) · Journal of the Pakistan Medical Association · doi:10.47391/jpma.10571
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.