QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 12,801–12,900 of 14,770
Madoshi, P. B., Tibenderana, J. R., Katusi, G. C., Karuhanga, T. A., & Machang’u, R. S. (2025) · Research Square · doi:10.21203/rs.3.rs-7607090/v1
Benabbas, R., Zehtabchi, S., Wakai, A., Allen, R. W., deSouza, I. S., Richards, R. J., Curley, D., Dunne, E., & Sinert, R. H. (2025) · Academic Emergency Medicine · doi:10.1111/acem.70175
“However, guidelines recommend reserving these tests for patients with clinical signs of cardiac syncope to reduce unnecessary testing and costs [8, 9].”
Guo, Q., Wang, R., & Guo, Y. (2025) · Medicine · doi:10.1097/md.0000000000045172 · Cited by 1
Wazir, M. U. K., Kaur, K., Shehzadi, Z., Mohamed, A. M. M., Shetty, S., Basha, B. M., Butt, M. F., Rasul, S., Makkiyah, M., & Farooqi, A. (2025) · Cureus · doi:10.7759/cureus.96430
“The methodological quality of included studies was appraised using the Newcastle-Ottawa Scale (NOS) for cohort and case-control studies [12] and the Quality Assessment of Diagnostic Accuracy Studies, Version 2 (QUADAS-2) tool for diagnostic accuracy studies [13].”
Madaeng, A. S. N. F., Sumardin, K. M., Sianipar, K. L., Makarim, A. R. D., Syahrial, A. M. A. F., & Masadah, R. (2025) · eJournal Kedokteran Indonesia · doi:10.23886/ejki.13.950.1
Aguilar, J. M. M. (2025) · Revista Publicando · doi:10.51528/rp.vol12.id2491
Luo, M., Tan, R., Cao, Q., 施裕新, Dai, H., Li, A., Shi, F., Guo, Z., Gong, S., Sun, Z., et al. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000003910
Diagnosis of depressive symptoms using mobile devices: a systematic review
Damasceno, M., Abrantes, P., Takahata, A. K., & Netto, A. V. (2025) · Revista de Investigação & Inovação em Saúde · doi:10.37914/riis.v8i2.439
Montero, J. A. (2025) · Respiratory Medicine · doi:10.1016/j.rmed.2025.108496
Ye, T., Jin, S., Xu, H., Li, H., Li, J., Sun, L., & Li, Q. (2025) · Clinical Radiology · doi:10.1016/j.crad.2025.107085
Anosike, U. G., Seferasi, L., Harrison, M. A., Albonico, R. J. N., ETUMUDON, S. I., & Mesquita, L. A. (2025) · medRxiv · doi:10.1101/2025.11.16.25340343
Niazmand, A., Salehi, M., Aria, H., Hosseini, N., & Mousavi, S. R. (2025) · Research Square · doi:10.21203/rs.3.rs-8119740/v1
Klopper, G. J., & Adeniyi, O. V. (2025) · Indian Journal of Otolaryngology and Head & Neck Surgery · doi:10.1007/s12070-025-06222-9
“Two indepen - dent reviewers will rate each domain as low, unclear, or high quality based on signalling questions, resolving disagree - ments by consensus or a third reviewer [ 68 ].”
InfluentialWu, D., Shu, L., Wang, C., Wang, X., Zhang, L., & Yan, B. (2025) · Allergy · doi:10.1111/all.70155
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)- 2 tool was used to assess the risk of bias in the included studies [24].”
de Macedo, B. A., Verdan, S., Joshi, D. K., Maciel, R. C., Sair, H. I., & Luna, L. (2025) · Neuroradiology · doi:10.1007/s00234-025-03841-5
ADETUNJI, S. A., & Divya, N. S. (2025) · medRxiv · doi:10.1101/2025.11.18.25340544
Protocol for preventing delirium in critically ill patients in intensive care units
Requelme, J. F. Z., Maya-Maldonado, M.-M., Moncada-Yanza, C. Y. C. Y., Sagal-Rodríguez, M. J., Lino, S. C. A., & Nuñez, J. M. A. (2025) · Salud Ciencia y Tecnología · doi:10.56294/saludcyt20262560
Alilou, A. M., khani, J., Rostami, R., & Chinehkesh, M. (2025) · Research Square · doi:10.21203/rs.3.rs-8126290/v1
Alilou, S. M., Alilou, A. M., & Bagi, H. R. M. (2025) · Research Square · doi:10.21203/rs.3.rs-8119985/v1
Asynchronous Teleultrasound and In-Person Ultrasound: Comparing Diagnostic Accuracy
CDA-AMC (2025) · Canadian Journal of Health Technologies · doi:10.51731/cjht.2025.1290
Nigam, J. S., Bharti, J. N., Pradeep, I., & Rath, A. (2025) · Acta Cytologica · doi:10.1159/000549667
“Two independent reviewers used the QUADAS-2 tool to critically assess the methodological quality of the final included research [8].”
Seretis, F., Panagaki, A., Gkolfakis, P., Tziatzios, G., & Paraskeva, K. D. (2025) · World Journal of Clinical Oncology · doi:10.5306/wjco.v16.i11.106498
Chen, G., Zhang, L., Peng, J., & Jiang, Y. Y. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-90509-1.00014-x
Bhatia, O., Madan, K., Tiwari, P., Mohan, A., Hadda, V., Suri, T. M., & Mittal, S. (2025) · Sleep And Breathing · doi:10.1007/s11325-025-03548-0
Orbelian, L. K., & Durleshter, V. M. (2025) · HERALD of North-Western State Medical University named after I I Mechnikov · doi:10.17816/mechnikov688368
Chamma-Wedemann, C. N. (2024) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.23.2024.tde-26092025-114214
Murphy, J., Kang, Y., Turner, P. J., Roberts, N. W., Hayward, G., Bird, C., & Fanshawe, T. R. (2026) · Diagnostics · doi:10.3390/diagnostics16081129 · Cited by 1
“No domains of the QUADAS-2 checklist [22] were rated as having high risk of bias or high concern that individual studies were not applicable to the review question, although many were rated as unclear because of gaps in reporting (Figures 2 and 3).”
InfluentialMohebbi, S., Mohebbi, A., Mohammadzadeh, S., Mohammadi, A., & Nabian, M. H. (2025) · Radiography · doi:10.1016/j.radi.2025.103242
A Systematic Review Evaluating Estimated GFR Performance in South Asian Populations
Gama, R. M., Sinha, A., Sarnowski, A., Dalrymple, K. V., Delanaye, P., & Bramham, K. (2025) · Kidney International Reports · doi:10.1016/j.ekir.2025.11.004 · Cited by 2
“18 Discordant results were reviewed and discussed internally.”
Olorosisimo, H. E. T., Sumperos, C. G., Adviento, A. L. A., Lachica, A. A. T., Cabalteja, J. L. A., Ubiña, A. G. R., Valentin, J. T., & Bremner, P. R. (2025) · Asian Biomedicine · doi:10.2478/abm-2025-0029
“The quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies‑2 (QUADAS‑2) tool, as recommended by the Healthcare Research and Quality Agency, Cochrane Collaboration, and the U.K. National Institute for Health and Clinical Excellence [15].”
Yan, Z., Tian, L., Dong, A., Song, Z., Zhu, X., & Chen, S. (2025) · Research Square · doi:10.21203/rs.3.rs-8036667/v1
Hajikarimloo, B., Mohammadzadeh, I., Hashemi, R., Tos, S. M., Bahrami, E., Najari, D., Ebrahimi, A., Hasanzade, A., & Habibi, M. A. (2025) · Clinical & Translational Oncology · doi:10.1007/s12094-025-04148-w
Papageorgiou, N., Haidich, A., Pagkalidou, E., Papaemmanouil, A., Γιουλεμέ, Ό., Triantafyllou, Α., Chourdakis, M., & Theodoridis, X. (2025) · Journal of Crohn s and Colitis · doi:10.1093/ecco-jcc/jjaf209
Danopoulos, E., Armstrong, N., McDermott, K., Chen, J., Tian, X.-B., Noake, C., & Westwood, M. E. (2025) · Health Technology Assessment · doi:10.3310/ajlk7403
Self-citationLas publicaciones médicas por dentro
de Antioquia, U., & Jaimes, F. A. (2025) · Editorial Universidad de Antioquia eBooks · doi:10.17533/udea.978-958-501-247-9
Evan's blue dye test for detection of aspiration in tracheostomized patients
Ivaldi, D., Burgos, M. A., Rico, S., Varela, L. B., Menai, S. D., Liquitay, C. M. E., & Garegnani, L. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016277
McCarrick, C. A., Singaravelu, A., Rasheed, A. A., & Murphy, R. (2025) · Cureus · doi:10.7759/cureus.98982 · Cited by 2
“Appraisal of methodological quality: Studies were assessed for methodological quality using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool for diagnostic accuracy studies [25].”
Hassankhani, A., Jannatdoust, P., Valizadeh, P., Amoukhteh, M., Mohammadi, A., Gholamrezanezhad, A., & Haq, A. (2025) · medRxiv · doi:10.64898/2025.12.11.25342045
Favalessa, D. M., Comper, B., & Júnior, M. R. (2025) · American Journal of Neuroradiology · doi:10.3174/ajnr.a9133
Al-Juhani, A. A., Desoky, R. M., AlJohani, N. I., Aljohani, O. O., Abdulkareem, R. A., AlQumaizy, R. N., Hakeem, H. F., Alasmari, A., & Badghaish, M. K. (2025) · Cureus · doi:10.7759/cureus.99092
“Studies are grouped according to their primary focus: Using the QUADAS-2 assessment technique [14], Table 3 provides a thorough analysis of methodological quality and risk of bias.”
Adekunle, M. O., Majaliwa, E., Reljic, T., Abebe, W., Assani, K., Atwiine, B., Ayisi, T., Bhakta, N. H., Deribessa, S. J., Johnson, L., et al. (2025) · JCO Global Oncology · doi:10.1200/go-25-00215
18F-FDG PET/CT: bicuspid aortic valve patients’ underestimated ally. A systematic review
Triumbari, E. K. A., Casciani, E., Guarneri, A., Sollaku, S., Leccisotti, L., Altini, C., Villani, M. F., Perrone, M. A., Panebianco, M., Palmieri, R., et al. (2025) · Clinical and Translational Imaging · doi:10.1007/s40336-025-00743-7
Hafedh, S., Ruslan, A. H., Ishaq, R. A. R., Hassan, R., & Maudhah, A. A. (2025) · Research Square · doi:10.21203/rs.3.rs-8108220/v1
Goto, S., Mizuki, Y., Horita, N., Meguro, A., Kawagoe, T., Teshigawara, T., Yamada, N., & Mizuki, N. (2025) · Ocular Immunology and Inflammation · doi:10.1080/09273948.2025.2599369
Oosterbaan, F., Wesseling, M., Piscaer, T. M., Hoedemakers, T., Harlaar, J., & Macri, E. M. (2025) · Journal of Sport Rehabilitation · doi:10.1123/jsr.2025-0162
Al‐Shammari, A. S., Sakini, A. S. A., Hasan, M. T., Islam, M. R., Shahzad, M., Alsawadi, R. A., Lingamsetty, S. S. P., Ibrahim, A. S., Marsool, M. D. M., Elgebaly, M., et al. (2025) · Cardiovascular Ultrasound · doi:10.1186/s12947-025-00364-0
“The methodological quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [16].”
InfluentialVílchez‐Cavazos, F., Rodríguez-Corpus, L. A., Arrambide‐Garza, F. J., Acosta‐Olivo, C., & Simental-Mendía, M. A. (2025) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-025-06153-8 · Cited by 1
“The quality assessment of included studies was performed using the ‘Quality assessment of studies of diagnostic accu - racy included in systematic reviews’ (QUADAS 2) tool, which included the risk of bias [ 35].”
140 Diagnostic Utility of Urinary Amylase in Acute Pancreatitis: A Systematic Review
Ullah, U., Chishti, S. S. A., Junaid, A., & Sarwar, M. (2025) · British journal of surgery · doi:10.1093/bjs/znag063.667
Kadadhekar, S. S., Yein, N., & Shaw, A. K. (2025) · Journal of Maxillofacial and Oral Surgery · doi:10.1007/s12663-025-02869-7
Heuts, S., Kawczynski, M. J., Lemmens, M.-J. D. K., Vernooy, K., Bidar, E., Flohr, T. G., Wildberger, J. E., Smulders, M. W., & Mihl, C. (2025) · Radiology Cardiothoracic Imaging · doi:10.1148/ryct.250313
Management of refractory ulcerative proctitis
Acosta, M. B., Mesonero, F., Ferreiro‐Iglesias, R., García‐López, S., Peris, M. A., Ausín, M. S., Cano-Sanz, N., Martínez, A. V., Cábez, A., Ramírez, S., et al. (2025) · Gastroenterología y Hepatología (English Edition) · doi:10.1016/j.gastre.2026.502646
Akram, N., Qaddoura, B., Karimaghaei, D., Mattoo, S., Al-Jumaili, A., & Radha, S. S. (2025) · Cureus · doi:10.7759/cureus.99729
“Multi-centre datasets, consensus-based labels, and external or prospective validation remain infrequent, yet are essential for establishing clinical credibility and aligning with frameworks such as QUADAS-AI, PROBAST-AI, and CLAIM [11-13].”
InfluentialUse of preoperative imaging in open globe injury management: a systematic review
Mair, J., Bush, L., Halliday, S., McMaster, D., Sellon, E., Colyer, M. H., McClellan, S. F., Justin, G. A., Hoskin, A. K., Cavuoto, K. M., et al. (2025) · British Journal of Ophthalmology · doi:10.1136/bjo-2025-327387
Broger, T. (2025) · heiDOK (Heidelberg University) · doi:10.11588/heidok.00036081
Arsiwala-Scheppach, L. T. (2024) · Refubium (Universitätsbibliothek der Freien Universität Berlin) · doi:10.17169/refubium-42438
Gavelli, F., Shi, R., Teboul, J., Azzolina, D., & Monnet, X. (2020) · Figshare · doi:10.6084/m9.figshare.12364322
Deschamps, J., Andersen, S. K., Webber, J. C., Featherstone, R., Sebastianski, M., Vandermeer, B., Senaratne, J., & Bagshaw, S. M. (2020) · Figshare · doi:10.6084/m9.figshare.12284525
Banerjee, A., Chen, S., Fatemifar, G., Zeina, M., Lumbers, R. T., Mielke, J., Gill, S. K., Kotecha, D., Freitag, D. F., Denaxas, S., et al. (2021) · Figshare · doi:10.6084/m9.figshare.14374671
Anarte-Lazo, E., Carvalho, G. F., Schwarz, A., Luedtke, K., & Falla, D. (2021) · Figshare · doi:10.6084/m9.figshare.16570138
Kouz, K., Michard, F., Bergholz, A., Vokuhl, C., Briesenick, L., Hoppe, P., Flick, M., Schön, G., & Saugel, B. (2021) · Figshare · doi:10.6084/m9.figshare.14337490
Vengesai, A., Midzi, H., Kasambala, M., Mutandadzi, H., Mduluza-Jokonya, T. L., Rusakaniko, S., Mutapi, F., Naicker, T., & Mduluza, T. (2021) · Figshare · doi:10.6084/m9.figshare.14684674
Anarte-Lazo, E., Carvalho, G. F., Schwarz, A., Luedtke, K., & Falla, D. (2021) · Figshare · doi:10.6084/m9.figshare.16570141
Aarntzen, E. H. J. G., Noriega-Álvarez, E., Artiko, V., Dias, A. H., Gheysens, O. S., Glaudemans, A. W. J. M., Lauri, C., Treglia, G., WYNGAERT, T. V. D., van Leeuwen, F. W. B., et al. (2021) · Figshare · doi:10.6084/m9.figshare.16575626
Babafemi, E. O., Cherian, B. P., Ouma, B., & Mogoko, G. M. (2021) · Figshare · doi:10.6084/m9.figshare.16893306
Taghavi, K., Rohner, E., Basu, P. S., Low, N., Rutjes, A. W., & Bohlius, J. (2020) · Figshare · doi:10.6084/m9.figshare.13245967
Self-citationDuan, J., Zhang, X., & Song, J. (2021) · Figshare · doi:10.6084/m9.figshare.16800250
Fellmeth, G. L., Harrison, S., Opondo, C., Nair, M., Kurinczuk, J. J., & Alderdice, F. (2021) · Figshare · doi:10.6084/m9.figshare.14456819
Gates, A., Pillay, J., Reynolds, D., Stirling, R., Traversy, G., Korownyk, C. S., Moore, A. E., Thériault, G., Thombs, B. D., Little, J., et al. (2021) · Figshare · doi:10.6084/m9.figshare.13514679
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495940
Additional file 1 of Instruments to measure fear of COVID-19: a diagnostic systematic review
Muller, A. E., Himmels, J. P. W., & Van de Velde, S. (2021) · Figshare · doi:10.6084/m9.figshare.14478951
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495958
Šehović, E., Urru, S., Chiorino, G., & Doebler, P. (2022) · Figshare · doi:10.6084/m9.figshare.20047290
Chen, J.-J., Chang, C.-H., Huang, Y.-T., & Kuo, G. C. (2020) · Figshare · doi:10.6084/m9.figshare.12270164
Li, X., Liu, C., Mao, Z., Xiao, M., Wang, L., Qi, S., & Zhou, F. (2020) · Figshare · doi:10.6084/m9.figshare.13245494
Anarte-Lazo, E., Carvalho, G. F., Schwarz, A., Luedtke, K., & Falla, D. (2021) · Figshare · doi:10.6084/m9.figshare.16570144
Decharatanachart, P., Chaiteerakij, R., Tiyarattanachai, T., & Treeprasertsuk, S. (2021) · Figshare · doi:10.6084/m9.figshare.13533143
Lin, Q., Zhang, C., 翁惠新, Lin, Y., Lin, Y., & Ruan, Z. (2023) · Figshare · doi:10.6084/m9.figshare.24123996
Kamalzadeh, L., Tayyebi, G., Shariati, B., Shati, M., Saeedi, V., & Malakouti, S. K. (2024) · Figshare · doi:10.6084/m9.figshare.25824681
Chong, Z. L., Sekaran, S. D., Soe, H. J., Peramalah, D., Rampal, S., & Ng, C.-W. (2020) · Figshare · doi:10.6084/m9.figshare.11979159
Zhu, X., Zhang, H., Sun, X., Li, Y., Li, J., Zeng, Y., Deng, P., Qi, X., chen, J., Ye, P., et al. (2021) · Figshare · doi:10.6084/m9.figshare.13550649
Zhang, Y., Zhou, G., Shi, W. S., Shi, W., Hu, M., Kong, D., Long, R., He, J., & Chen, N. (2023) · Figshare · doi:10.6084/m9.figshare.22614430
Qin, D., Bai, A., Xue, P., Seery, S., Wang, J., Mendez, M. J. G., Li, Q., Jiang, Y., & Qiao, Y. (2023) · Figshare · doi:10.6084/m9.figshare.22609291
Swain, M. S., Henschke, N., Kamper, S. J., Downie, A., Koes, B. W., & Maher, C. G. (2020) · Figshare · doi:10.6084/m9.figshare.12940269
Babafemi, E. O., Cherian, B. P., Ouma, B., & Mogoko, G. M. (2021) · Figshare · doi:10.6084/m9.figshare.16893309
Taghavi, K., Rohner, E., Basu, P. S., Low, N., Rutjes, A. W., & Bohlius, J. (2020) · Figshare · doi:10.6084/m9.figshare.13245958
Self-citationShen, X., Zhang, J., Huang, Y., Tong, J., Zhang, L., Zhang, Z., Yu, W., & Qiu, Y. (2020) · Figshare · doi:10.6084/m9.figshare.13181701
Kalin, A., Javid, B., Knight, M., Inada-Kim, M., & Greenhalgh, T. (2021) · Figshare · doi:10.6084/m9.figshare.14228071
Yon, J. L. T., Htet, N. H., Naing, C., Tung, W. S., Aung, H. H., & Mak, J. W. (2023) · Figshare · doi:10.6084/m9.figshare.22608475
Roberts, T., Keddie, S., Rattanavong, S., Gomez, S. R., Bradley, J., Keogh, R. H., Bärenbold, O., Falconer, J., Mens, P. F., Hopkins, H., et al. (2023) · Figshare · doi:10.6084/m9.figshare.24540680
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495979
Mokkink, L. B., Boers, M., van der Vleuten, C. P. M., Bouter, L. M., Alonso, J., Patrick, D. L., de Vet, H. C. W., & Terwee, C. B. (2020) · Figshare · doi:10.6084/m9.figshare.13323854
Anarte-Lazo, E., Carvalho, G. F., Schwarz, A., Luedtke, K., & Falla, D. (2021) · Figshare · doi:10.6084/m9.figshare.16570150
Anarte-Lazo, E., Carvalho, G. F., Schwarz, A., Luedtke, K., & Falla, D. (2021) · Figshare · doi:10.6084/m9.figshare.16570135
Banerjee, A., Chen, S., Fatemifar, G., Zeina, M., Lumbers, R. T., Mielke, J., Gill, S. K., Kotecha, D., Freitag, D. F., Denaxas, S., et al. (2021) · Figshare · doi:10.6084/m9.figshare.14374662
Mackey, A. R., Bussé, A. M. L., Del Vecchio, V., Mäki-Torkko, E., & Uhlén, I. (2022) · Figshare · doi:10.6084/m9.figshare.20444343
Kathrikolly, T., Nair, S. N. P., Mathew, A., Saxena, P. P. U., & Nair, S. (2022) · Figshare · doi:10.6084/m9.figshare.21303706
Banerjee, A., Chen, S., Fatemifar, G., Zeina, M., Lumbers, R. T., Mielke, J., Gill, S. K., Kotecha, D., Freitag, D. F., Denaxas, S., et al. (2021) · Figshare · doi:10.6084/m9.figshare.14374677
Alvarado Sánchez, J. I., Caicedo Ruiz, J. D., Fernández, J. J. D., Zúñiga, W. F. A., Ospina-Tascón, G. A., & Cruz Martínez, L. E. (2021) · Figshare · doi:10.6084/m9.figshare.13788061
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495961
Gates, A., Pillay, J., Reynolds, D., Stirling, R., Traversy, G., Korownyk, C. S., Moore, A. E., Thériault, G., Thombs, B. D., Little, J., et al. (2021) · Figshare · doi:10.6084/m9.figshare.13514685
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.