QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 4,801–4,900 of 14,770
Nikas, I. P., Proctor, T., Seide, S., Chatziioannou, S. S., REYNOLDS, J. P., & Ntourakis, D. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23031650 · Cited by 29
Mutala, T. M., Mwango, G. N., Aywak, A. A., Cioni, D., & Neri, E. (2022) · Cancer Imaging · doi:10.1186/s40644-022-00447-5 · Cited by 29
Heim, B., Peball, M., Hammermeister, J., Djamshidian, A., Krismer, F., & Seppi, K. (2022) · Journal of Parkinson s Disease · doi:10.3233/jpd-213012 · Cited by 29
Wang, R., Zhang, H., Ding, P., & Jiao, Q. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-03001-y · Cited by 26
Hirooka, M., Koizumi, Y., Sunago, K., Nakamura, Y., Hirooka, K., Watanabe, T., Yoshida, O., Tokumoto, Y., Abe, M., & Hiasa, Y. (2022) · Journal of Medical Ultrasonics · doi:10.1007/s10396-022-01196-5 · Cited by 27
Rutkūnas, V., Gedrimienė, A., Auškalnis, L., Admakin, O. I., & Mangano, F. G. (2022) · Journal of Prosthodontics · doi:10.1111/jopr.13449 · Cited by 26
Yin, H., Yang, X., Sun, L., Pan, P., Peng, L., Li, K., Zhang, D., Cui, F., Xia, C., Huang, H., et al. (2022) · Endoscopic Ultrasound · doi:10.4103/eus-d-21-00131 · Cited by 31
Chen, H., Nakagawa, A., Takamori, M., Abe, S., Ueno, D., Horita, N., Kato, S., & Seki, N. (2022) · Infection · doi:10.1007/s15010-022-01789-9 · Cited by 26
The effect of exercise on left ventricular global longitudinal strain
Murray, J., Bennett, H., Bezak, E., Perry, R., & Boyle, T. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04931-5 · Cited by 28
Piccardo, A., Fiz, F., Treglia, G., Bottoni, G., & Trimboli, P. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11071919 · Cited by 27
The added value of artificial intelligence to LI-RADS categorization: A systematic review
Laino, M. E., Viganò, L., Ammirabile, A., Lofino, L., Generali, E., Francone, M., Lleò, A., Saba, L., & Savevski, V. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110251 · Cited by 26
Kuo, K.-M., Talley, P. C., & Chang, C.-S. (2022) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2022.104791 · Cited by 26
Spagnol, G., Noventa, M., Bonaldo, G., Marchetti, M., Vitagliano, A., Laganà, A. S., Cavallin, F., Scioscia, M., Saccardi, C., & Tozzi, R. (2022) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.24967 · Cited by 30
de Arenas‐Arroyo, S. N., Cavero‐Redondo, I., Torres-Costoso, A. I., Reina‐Gutiérrez, S., Guzmán‐Pavón, M. J., & Martínez‐Vizcaíno, V. (2022) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2022.10828 · Cited by 29
Chen, L., Niu, X., Wang, Y., Lv, S., Zhou, X., Yang, Z., & Peng, D. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.942629 · Cited by 30
Li, Z., Gao, Y., Gong, H., Feng, W., Ma, Q., Li, J., Lu, X., Wang, X., & Lei, J. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28399 · Cited by 29
Duarte, M. L., Motta, G. G. B., Rodrigues, N. V. M., Chiovatto, A. R. S., Chiovatto, E. D., & Iared, W. (2022) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2021.0852.13062022 · Cited by 26
Zhong, J., Hu, Y., Xing, Y., Ge, X., Ding, D., Zhang, H., & Yao, W. (2022) · Insights into Imaging · doi:10.1186/s13244-022-01279-4 · Cited by 28
Onakpoya, I., Heneghan, C. J., Spencer, E. A., Brassey, J., Roşca, E. C., Maltoni, S., Plüddemann, A., Evans, D. H., Conly, J. M., & Jefferson, T. (2022) · Journal of Hospital Infection · doi:10.1016/j.jhin.2022.09.007 · Cited by 29
“The risk of bias in included studies was assessed using modified Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) criteria [8].”
Jiang, D., Zhang, Y., Wang, Y., Xu, F., Liang, J., & Wang, W. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.1012418 · Cited by 31
Tang, H., Xu, J., Yuan, W., Wang, Y., Yue, B., & Qu, X. (2022) · Orthopaedic Surgery · doi:10.1111/os.13500 · Cited by 26
Understanding misophonia from an audiological perspective: a systematic review
Aryal, S., & Prabhu, P. (2022) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-022-07774-0 · Cited by 27
Karabacak, M., Ozkara, B. B., Öztürk, A., Kaya, B., Cirak, Z., Orak, E., & Ozcan, Z. (2022) · Acta Radiologica · doi:10.1177/02841851221143496 · Cited by 27
Tsai, W.-W., Hung, K., Huang, Y., Yu, C., Lin, C., Chen, I., & Sun, C. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1109681 · Cited by 35
Mohammadie, Z. E., Akhlaghi, S., Samaeinasab, S., Bojd, S. S., Jamialahmadi, T., & Sahebkar, A. (2023) · Reviews in Medical Virology · doi:10.1002/rmv.2428 · Cited by 28
Roggio, F., Petrigna, L., Filetti, V., Vitale, E., Rapisarda, V., & Musumeci, G. (2023) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2023.103524 · Cited by 30
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (Whiting et al., 2011) was employed to assess the risk of bias, applicability, and diagnostic accuracy of IRT in the treatment of scoliosis.”
Adinolfi, A., Sirotti, S., Sakellariou, G., Cipolletta, E., Filippucci, E., Porta, F., Zanetti, A., Ughi, N., Sarzi‐Puttini, P., Scirè, C. A., et al. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1131362 · Cited by 26
Dhaliwal, M., & Daneman, N. (2023) · Clinical Infectious Diseases · doi:10.1093/cid/ciad225 · Cited by 27
Seth, E. A., Watterson, J., Xie, J., Arulsamy, A., Yusof, H. H. M., Ngadimon, I. W., Khoo, C. S., Kadirvelu, A., & Shaikh, M. F. (2023) · Epilepsia Open · doi:10.1002/epi4.12854 · Cited by 31
CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
Sousa, J. A., Sondermann, A., Bernardo-Castro, S., Varela, R., Donato, H., & Sargento‐Freitas, J. (2023) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8080 · Cited by 28
Taddese, A. A., Tilahun, B. C., Awoke, T., Atnafu, A., Mamuye, A. L., & Mengiste, S. A. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2023.1216326 · Cited by 32
The State of Artificial Intelligence in Pediatric Surgery: A Systematic Review
Elahmedi, M. O., Sawhney, R., Guadagno, E., Botelho, F. M. N., & Poenaru, D. (2024) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2024.01.044 · Cited by 26
Carpenter, C. R., Lee, S., Kennedy, M., Arendts, G., Schnitker, L., Eagles, D. A., Mooijaart, S. P., Fowler, S., Doering, M. M., LaMantia, M. A., et al. (2024) · Academic Emergency Medicine · doi:10.1111/acem.14935 · Cited by 29
Botnari, A., Kadar, M., & Pătraşcu, J. M. (2024) · Diagnostics · doi:10.3390/diagnostics14111090 · Cited by 29
Interleukin-6 for diagnosis of sepsis in critically ill adult patients
Molano-Franco, D., Arévalo-Rodríguez, I., Figuls, M. R. I., & Zamora, J. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011811 · Cited by 27
Lian, M., Liu, S., Wu, G.-Y., & Liu, S.-Y. (2015) · Clinics and Research in Hepatology and Gastroenterology · doi:10.1016/j.clinre.2015.06.002 · Cited by 26
A Systematic Review of Current Clinical and Instrumental Swallowing Assessment Methods
Martino, R., Flowers, H. L., Shaw, S. M., & Diamant, N. E. (2013) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-013-0033-y · Cited by 29
Athikarisamy, S. E., Patole, S., Lam, G. C., Dunstan, C., & Rao, S. C. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-304984 · Cited by 27
Shaw, S. M., Skoretz, S. A., O’Sullivan, B., Hope, A. J., Liu, L. W. C., & Martino, R. (2015) · Head & Neck · doi:10.1002/hed.24249 · Cited by 28
Regacini, R., Puchnick, A., Shigueoka, D. C., Iared, W., & Lederman, H. M. (2015) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2014.8312810 · Cited by 26
Diagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis
Yan, S., Liu, Z., Yu, S., & Bao, Y. (2016) · Medical Science Monitor · doi:10.12659/msm.900590 · Cited by 26
Harder, T., Takla, A., Eckmanns, T., Ellis, S., Forland, F., James, R., Meerpohl, J. J., Morgan, A. R., Rehfuess, E. A., Schünemann, H. J., et al. (2017) · Eurosurveillance · doi:10.2807/1560-7917.es.2017.22.40.16-00620 · Cited by 30
Nieuwsma, J. A., Williams, J. W., Namdari, N., Washam, J. B., Raitz, G., Blumenthal, J. A., Jiang, W., Yapa, R., McBroom, A. J., Lallinger, K. R., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m17-1811 · Cited by 35
for the EANM-EAN Task Force for the Prescription of FDG-PET for Dementing Neurodegenerative Disorders, Boccardi, M., Festari, C., Altomare, D., Gandolfo, F., Orini, S., Nobili, F. M., & Frisoni, G. B. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4024-1 · Cited by 31
Yu, T., Geng, J., Song, W., & Jiang, Z. (2018) · BioMed Research International · doi:10.1155/2018/8591387 · Cited by 26
Agasthi, P., Kanmanthareddy, A., Khalil, C., Egbuche, O., Yarlagadda, V., Sachdeva, R., & Arsanjani, R. (2018) · Scientific Reports · doi:10.1038/s41598-018-29910-9 · Cited by 26
Agah, E., Saleh, F., Moghaddam, H. S., Saghazadeh, A., Tafakhori, A., & Rezaei, N. (2018) · Systematic Reviews · doi:10.1186/s13643-018-0913-4 · Cited by 30
Knowledge Synthesis in Evidence-Based Medicine
Garritty, C., Stevens, A., Hamel, C., Golfam, M., Hutton, B., & Wolfe, D. M. (2019) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2018.11.006 · Cited by 30
Kapoula, G. V., Kontou, P. I., & Bagos, P. G. (2019) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2018.028530 · Cited by 35
Bytyçi, I., Bajraktari, G., Lindqvist, P., & Henein, M. Y. (2019) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12587 · Cited by 26
Wong, P. C. H., Lee, G., Sedie, A. D., Hánová, P., İnanç, N., Jousse‐Joulin, S., Ohrndorf, S., Stoenoiu, M. S., Keen, H. I., Terslev, L., et al. (2019) · The Journal of Rheumatology · doi:10.3899/jrheum.181087 · Cited by 26
Meyer, M., Dardel, N. T., Jreige, M., Kamani, C. H., Moshebah, M., Muoio, B., Lalonde, M. N., Schaefer, N. G., Giovanella, L., Prior, J. O., et al. (2019) · Diagnostics · doi:10.3390/diagnostics9020060 · Cited by 32
MRI as Diagnostic Modality for Analyzing the Problematic Knee Arthroplasty: A Systematic Review
Schröder, F. F., Post, C. E., Wagenaar, F. B. M., Verdonschot, N. J. J., & Veld, R. M. H. A. H. I. ’. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26874 · Cited by 26
Kim, S.-J., & Lee, S. W. (2019) · Clinical Radiology · doi:10.1016/j.crad.2019.06.022 · Cited by 26
Vollenbrock, S. E., Voncken, F. E. M., Bartels, L. W., Beets‐Tan, R. G. H., & Rutten, A. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.07.006 · Cited by 26
Wang, H., Li, X., Zhou, D., & Huang, J. (2019) · The International Journal of Biological Markers · doi:10.1177/1724600819880906 · Cited by 27
Lu, M., Luo, X., Ni, L., Chen, H., & Dai, M. (2019) · Clinical Epidemiology · doi:10.2147/clep.s213677 · Cited by 32
Stonestreet, J., Chandrapalan, S., Woolley, D., Uthman, O. A., & Arasaradnam, R. P. (2019) · PubMed · Cited by 26
Zhang, H., Sun, Z., Li, L., Sun, R., & Zhang, H. (2020) · BMC Ophthalmology · doi:10.1186/s12886-019-1288-6 · Cited by 26
Chen, J.-Q., Liu, S., Tang, Y., Zhang, X., Cao, M., Xiao, Z., Ren, M., & Chen, T. (2020) · Clinical Radiology · doi:10.1016/j.crad.2019.12.014 · Cited by 26
Knoery, C., Heaton, J., Polson, R., Bond, R., Iftikhar, A., Rjoob, K. W. Y., McGilligan, V., Peace, A. J., & Leslie, S. J. (2020) · Critical Pathways in Cardiology A Journal of Evidence-Based Medicine · doi:10.1097/hpc.0000000000000217 · Cited by 31
Mistry, J., Heneghan, N. R., Noblet, T., Falla, D., & Rushton, A. (2020) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-020-03436-6 · Cited by 28
Syed, S., Ashwick, R., Schlosser, M., González-Izquierdo, A., Li, L., & Gilbert, R. E. (2020) · Archives of Disease in Childhood · doi:10.1136/archdischild-2020-319027 · Cited by 30
Roşca, E. C., & Simu, M. A. (2020) · Brain Sciences · doi:10.3390/brainsci10090588 · Cited by 29
Palaniyappan, L. K., Maayan, N., Bergman, H., Davenport, C. F., Adams, C. E., & Soares‐Weiser, K. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011021.pub2 · Cited by 32
Li, X.-T., Zhang, X., Sun, Y., Tang, L., & Cao, K. (2016) · Medicine · doi:10.1097/md.0000000000005333 · Cited by 26
George, J. M., Pannek, K., Rose, S., Ware, R. S., Colditz, P. B., & Boyd, R. N. (2017) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.13611 · Cited by 26
Saramago, P., Yang, H., Llewellyn, A., Walker, R., Harden, M., Palmer, S., Griffin, S. C., & Simmonds, M. C. (2018) · Health Technology Assessment · doi:10.3310/hta22130 · Cited by 27
Fu, J., Li, Y., Li, Z., & Li, N. (2018) · Bioscience Reports · doi:10.1042/bsr20180044 · Cited by 26
Yu, B., Zhu, X., Liang, Z., Sun, Y., Zhao, W., & Chen, K.-H. (2018) · Cancer Management and Research · doi:10.2147/cmar.s155542 · Cited by 26
Kim, D. W., Yoon, H. M., Jung, A. Y., Lee, J. S., Oh, S. H., Kim, K. M., & Cho, Y. A. (2018) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14764 · Cited by 26
“Quality Assessment The methodological quality was assessed with tailored questionnaires and the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria.(23) The literature search, study selection, data extraction, and quality assessment were independently assessed by 2 reviewers (D.”
MethodThe Use of Deep Learning Software in the Detection of Voice Disorders: A Systematic Review
Barlow, J., Sragi, Z., Rivera‐Rivera, G., Al‐Awady, A., Daşdöğen, Ü., Courey, M. S., & Kirke, D. N. (2024) · Otolaryngology–Head and Neck Surgery · doi:10.1002/ohn.636 · Cited by 25
Wilson, M. P., Haidey, J., Murad, M. H., Sept, L., & Low, G. (2023) · European Radiology · doi:10.1007/s00330-023-09916-2 · Cited by 25
Xavier, D. P., Miyawaki, I. A., Jorge, C. A. C., Silva, G. B. F., Lloyd, M. R., de Moraes, F. Y., Patel, B., & Batalini, F. (2023) · Journal of Medical Screening · doi:10.1177/09691413231219952 · Cited by 26
He, J., Wang, S.-X., & Liu, P. (2024) · British Journal of Radiology · doi:10.1093/bjr/tqae098 · Cited by 26
Mathew, R., Roy, W. E., Thomas, E. S., Meena, N. K., & Васильевна, Д. О. (2024) · Journal of Thoracic Disease · doi:10.21037/jtd-24-348 · Cited by 25
Malhotra, M., Shaw, A. K., Priyadarshini, S. R., Metha, S. S., Sahoo, P. K., & Gachake, A. (2024) · Asian Pacific Journal of Cancer Prevention · doi:10.31557/apjcp.2024.25.8.2593 · Cited by 29
“The methodological quality or the risk of bias was evaluated using Quality Assessment for Diagnostic Accuracy Studies -2 (QUADAS-2) tool [18].”
BackgroundMethodGuerrini, S., Zanoni, M., Sica, C., Bagnacci, G., Mancianti, N., Galzerano, G., Garosi, G., Cacioppa, L. M., Cellina, M. I., Zamboni, G., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13216345 · Cited by 25
Host Markers of Periodontal Diseases: Meta‐Analysis of Diagnostic Accuracy Studies
Rakić, M., Calciolari, E., Grant, M. M., Radovanović, S., Bostancı, N., & Preshaw, P. M. (2025) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.14167 · Cited by 31
Melo, R. H., Gioli‐Pereira, L., Lourenço, I. D., Passos, R. D. H., Bernardo, A. T., & Volpicelli, G. (2025) · Critical Care · doi:10.1186/s13054-025-05359-x · Cited by 25
“Two authors (R.M. and I.D.) independently performed the Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2) [16] to evaluate the risk of bias,which was tailored to suit the review question.”
Haghighat, S., Joghatayi, M., Issa, J., Azimian, S., Brinz, J., Ashkan, A., Chaurasia, A., Rahimian, Z., & Sangalli, L. (2025) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-025-03129-x · Cited by 27
“The QUADAS-2 (Quality Assessment Tool for Diagnostic Accuracy Studies - Version 2) checklist was used to evaluate the quality of diagnostic accuracy studies [20].”
Lu, J., Dong, Z., Ye, L., Gao, Y., & Zheng, Z. (2025) · PLoS ONE · doi:10.1371/journal.pone.0332525 · Cited by 32
“The QUADAS-2 tool [16] was adopted for evaluation.”
LAIGNELOT, F., Martin, G. L., OSSMAN, M., Pingeon, O., BOUBAKER, A., PICOVSCHI, E., Jia, K. I. M., Tannier, X., Cohen, J. F., & Dechartres, A. (2026) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2026.112221 · Cited by 39
Smallwood, M., Vijh, R., Nauche, B., Lebouché, B., Joseph, L., & Pai, N. P. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149592 · Cited by 25
Martin, M. S., Potter, B. K., Crocker, A. G., Wells, G. A., & Colman, I. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154106 · Cited by 28
Zhou, Y., Wang, C., Zhu, H., Lin, Y., Pan, B., Zhang, X., Huang, X., Xu, Q., Xu, Y., & Sun, Q. (2016) · PLoS ONE · doi:10.1371/journal.pone.0158143 · Cited by 26
Song, J., Ma, Z., Huang, J., Liu, S., Luo, Y., Lu, Q., Schwabl, P., Zykus, R., Kumar, A., & Kitson, M. T. (2018) · European Radiology · doi:10.1007/s00330-018-5478-z · Cited by 29
Molano‐González, N., Olivares‐Martínez, E., Anaya, J., & Hernández‐Molina, G. (2018) · Scandinavian Journal of Rheumatology · doi:10.1080/03009742.2018.1469164 · Cited by 25
Defining the relationship between arm and leg blood pressure readings
Sheppard, J. P., Albasri, A., Franssen, M., Fletcher, B., Pealing, L. M., Roberts, N. W., Obeid, A., Pucci, M., McManus, R. J., & Martin, U. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001958 · Cited by 25
Meta-Analysis: Urinary Calprotectin for Discrimination of Intrinsic and Prerenal Acute Kidney Injury
Chen, J., Fan, P., Kou, G., Chang, S.-W., Chen, Y., Lee, C., & Chang, C. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8010074 · Cited by 25
Hu, J., Zhang, K., Yan, Y., Zang, Y., Wang, Y., & Xue, F. (2019) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-019-05207-8 · Cited by 27
Li, L., Gao, H., Zhang, C., Tu, J., Geng, X., Wang, J., Zhou, X., Pan, W., & Jing, J. (2019) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.14758 · Cited by 25
Meyer, M., Lalonde, M. N., Dardel, N. T., Jreige, M., Kamani, C. H., Boughdad, S., Muoio, B., Becce, F., Schaefer, N. G., Candrian, C., et al. (2019) · Diagnostics · doi:10.3390/diagnostics10010002 · Cited by 27
Toolkit of methodological resources to conduct systematic reviews
Figuls, M. R. I., García, L. M., Solà, I., Alonso‐Coello, P., Bonfill, X., & Zamora, J. (2020) · F1000Research · doi:10.12688/f1000research.22032.2 · Cited by 29
Lacasse, A., Charest, E. C., Dault, R., Cloutier, A., Choinière, M., Blais, L., & Vanasse, A. (2020) · Pain Medicine · doi:10.1093/pm/pnaa004 · Cited by 26
Si, X., Song, X., Lin, Q., Nie, Y., Zhang, G., Xu, H., Chen, M., Wu, J., & Guan, X. (2020) · Shock · doi:10.1097/shk.0000000000001545 · Cited by 25
Lauridsen, K. G., Baldi, E., Smyth, M. A., Perkins, G. D., Greif, R., Bigham, B. L., Bray, J., Breckwoldt, J., Duff, J. P., Gilfoyle, E., et al. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.10.036 · Cited by 26
Taghavi, K., Rohner, E., Basu, P. S., Low, N. N., Rutjes, A. W., & Bohlius, J. (2020) · BMC Women s Health · doi:10.1186/s12905-020-01121-3 · Cited by 29
Self-citationShaikh, K., Rajakumar, V., Osio, V. A., & Shaikh, N. (2021) · Pediatric Nephrology · doi:10.1007/s00467-020-04854-3 · Cited by 25
Alonso, C. C. G., Silva, F. G., Costa, L. O. P., & de Freitas, S. M. S. F. (2021) · Expert Review of Neurotherapeutics · doi:10.1080/14737175.2021.1886925 · Cited by 28
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.