QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 4,901–5,000 of 14,770
Diagnostic Utility of Ultrasound Versus Physical Examination in Assessing Knee Effusions
Meyer, R., Lin, C., Yenokyan, G., & Ellen, M. I. (2021) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15676 · Cited by 25
Feng, Z., Zhao, H., Guan, S., Wang, W., & Rong, P. (2021) · Liver International · doi:10.1111/liv.14850 · Cited by 25
Chung, M. J., Park, S. W., Kim, S., Cho, C. M., Choi, J.-H., Choi, E. K., Lee, T. H., Cho, E., Lee, J. K., Song, T. J., et al. (2021) · Clinical Endoscopy · doi:10.5946/ce.2021.069 · Cited by 27
Bhandari, A., Sharma, C., Ibrahim, M. A., Riggs, M., Jones, R. E., & Lasocki, A. (2021) · Neuroradiology · doi:10.1007/s00234-021-02702-1 · Cited by 26
Breath analysis for the detection of digestive tract malignancies: systematic review
Hintzen, K. F. H., Grote, J., Wintjens, A. G. W. E., Lubbers, T., Eussen, M. M. M., van Schooten, F., Bouvy, N. D., & Peeters, A. (2021) · BJS Open · doi:10.1093/bjsopen/zrab013 · Cited by 27
Laukhtina, E., Rajwa, P., Mori, K., Moschini, M., D’Andrea, D., Abufaraj, M. M., Soria, F., Mari, A., Krajewski, W. R., Albisinni, S., et al. (2021) · European Urology Focus · doi:10.1016/j.euf.2021.05.010 · Cited by 25
A systematic review of next-generation point-of-care stroke diagnostic technologies
Shahrestani, S., Wishart, D., Han, S. M., Strickland, B. A., Bakhsheshian, J., Mack, W. J., Toga, A. W., Sanossian, N., Tai, Y., & Zada, G. (2021) · Neurosurgical FOCUS · doi:10.3171/2021.4.focus21122 · Cited by 25
Li, Z., Li, J., Lu, X., Qu, M., Tian, J., & Lei, J. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109931 · Cited by 25
Nguyen, N. N., Huynh, L. B. P., Do, M. D., Yang, T. Y., Tsai, M., & Chen, Y. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.735875 · Cited by 25
Fitz-patrick, E., Sharma, V., Rojoa, D., Raheman, F., & Singh, H. (2021) · Skeletal Radiology · doi:10.1007/s00256-021-03883-9 · Cited by 25
Nakata, K. C. D. F., Pereira, P. P. D. S., & Riveros, B. S. (2021) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2021.09.010 · Cited by 30
Li, Q., Ma, T., Wang, Z., Huang, L., Liu, W., Chen, M., Sang, T., Ren, X., Jin, T., Cao, C., et al. (2021) · Journal of Clinical Ultrasound · doi:10.1002/jcu.23073 · Cited by 25
“According to Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2), the quality assessment of the included articles was independently evaluated by two reviewers.(25) When the two reviewers did not agree on the result, the final result would be determined by discussion.”
Impact of mobile devices on cancer diagnosis in cytology
Santonicco, N., Marletta, S., Pantanowitz, L., Fadda, G., Troncone, G., Brunelli, M., Ghimenton, C., Antonini, P., Paolino, G., Girolami, I., et al. (2021) · Diagnostic Cytopathology · doi:10.1002/dc.24890 · Cited by 28
Harry, V. N., Persad, S., Bassaw, B., & Parkin, D. E. (2021) · Gynecologic Oncology Reports · doi:10.1016/j.gore.2021.100883 · Cited by 25
Biomarkers of idiosyncratic drug-induced liver injury (DILI) - a systematic review
Atallah, E., Freixo, C., Álvarez‐Álvarez, I., Cubero, F. J., Gerbes, A. L., Kullak-Ublick, G. A., & Aithal, G. P. (2021) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2021.1999410 · Cited by 27
“We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool to evaluate the quality of diagnostic studies and Quality in the Prognostic Studies (QUIPS) tool for prognostic studies [20,21].”
Cai, X., Ebell, M. H., & Haines, L. (2021) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2021.06.210217 · Cited by 25
van der Hoogt, K. J. J., Schipper, R. J., Winter-Warnars, G. A. O., ter Beek, L. C., Loo, C. E., Mann, R. M., & Beets‐Tan, R. G. H. (2021) · Insights into Imaging · doi:10.1186/s13244-021-01123-1 · Cited by 26
Ye, L., Chen, Y., Xu, H., Xie, H., Yao, J., Liu, J., & Song, B. (2022) · European Radiology · doi:10.1007/s00330-022-08696-5 · Cited by 25
Huang, H., Wu, C., Shen, Q., Fang, Y., & Xu, H. (2022) · Critical Care · doi:10.1186/s13054-022-03890-9 · Cited by 28
Han, H., Chen, Y., Li, R., Lin, F., Lu, J., Chen, X., & Wang, S. (2022) · Neurosurgical Review · doi:10.1007/s10143-022-01779-3 · Cited by 25
Ran, X., Hu, T., & Li, Z. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.810631 · Cited by 25
Wang, M. K., Piticaru, J., Kappel, C., Mikhaeil, M. S., Mbuagbaw, L. C. E., & Rochwerg, B. N. (2022) · Internal and Emergency Medicine · doi:10.1007/s11739-022-03003-y · Cited by 26
Caetano, G., Soares, M. Q. S., Oliveira, L., Junqueira, J. L. C., & Nascimento, M. (2022) · Journal of Clinical and Experimental Dentistry · doi:10.4317/jced.59384 · Cited by 25
Beswick, E., Fawcett, T., Hassan, Z., Forbes, D., Dakin, R. S., Newton, J. L., Abrahams, S., Carson, A. J., Chandran, S., Perry, D., et al. (2022) · Journal of Neurology · doi:10.1007/s00415-022-11312-7 · Cited by 29
Wilmoth, K., Brett, B. L., Emmert, N. A., Cook, C. M., Schaffert, J., Caze, T. J., Kotsonis, T., Cusick, M. M., Solomon, G. S., Resch, J. E., et al. (2022) · Neuropsychology Review · doi:10.1007/s11065-022-09553-4 · Cited by 27
“Risk of bias was assessed via the Quality Assessment of Diagnostic Accuracy Studies—Version 2 (QUADAS-2; Whiting et al., 2011).”
Bijvoet, G. P., Nies, H. M. J. M., Holtackers, R. J., Linz, D., Adriaans, B. P., Nijveldt, R., Wildberger, J. E., Vernooy, K., Chaldoupi, S., & Mihl, C. (2022) · Radiology Cardiothoracic Imaging · doi:10.1148/ryct.220061 · Cited by 25
Assessment of Posterolateral Lumbar Fusion
Lehr, A. M., Duits, A., Reijnders, M. R. L., Nutzinger, D., Castelein, R. M., Öner, F. C., & Kruyt, M. C. (2022) · JBJS Reviews · doi:10.2106/jbjs.rvw.22.00129 · Cited by 25
Firouzabadi, F. D., Gopal, N., Homayounieh, F., Anari, P. Y., Li, X., Ball, M. W., Jones, E. C., Samimi, S., Turkbey, E. B., & Malayeri, A. A. (2022) · Clinical Imaging · doi:10.1016/j.clinimag.2022.11.007 · Cited by 25
Senarai, T., Pratipanawatr, T., Yurasakpong, L., Kruepunga, N., Limwachiranon, J., Phanthong, P., Meemon, K., Yammine, K., & Suwannakhan, A. (2022) · Medicina · doi:10.3390/medicina58121696 · Cited by 25
Skinner, S., Giles-Clark, H. J., Higgins, C., Mol, B. W., & Rolnik, D. L. (2022) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.11.1294 · Cited by 25
Magwood, O., Bellai‐Dussault, K., Fox, G., McCutcheon, C., Adams, O., Saad, A., & Kassam, A. (2022) · Journal of Migration and Health · doi:10.1016/j.jmh.2022.100144 · Cited by 28
Huertas-López, A., Álvarez‐García, G., Sánchez-Sánchez, R., Cantos-Barreda, A., Ibáñez‐López, F. J., Martínez-Subiela, S., Cerón, J. M. C., & Martínez‐Carrasco, C. (2023) · Research in Veterinary Science · doi:10.1016/j.rvsc.2023.01.005 · Cited by 25
Koch, A. H., Jeelof, L. S., Muntinga, C. L. P., Gootzen, T. A., van de Kruis, N. M. A., Nederend, J., Boers, T. G. W., van der Sommen, F., & Piek, J. M. J. (2023) · Insights into Imaging · doi:10.1186/s13244-022-01345-x · Cited by 26
Shokoohi, H., Mayes, K. D., Peksa, G. D., Loesche, M. A., Becker, B. A., Boniface, K. S., Lahham, S., Jang, T. B., Secko, M. A., & Gottlieb, M. A. (2023) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2023.05.039 · Cited by 27
Ultrasound Elastography to Assess Age of Deep Vein Thrombosis: A Systematic Review
Santini, P., Esposto, G., Ainora, M. E., Lupascu, A., Gasbarrini, A., Zocco, M. A., & Pola, R. (2023) · Diagnostics · doi:10.3390/diagnostics13122075 · Cited by 31
Jiang, L., Zhang, D., Chen, Y.-N., Yu, X.-J., Pan, M.-F., & Lian, L. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1182259 · Cited by 31
Potdukhe, S., Iyer, J., & Nadgere, J. B. (2023) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2023.04.021 · Cited by 36
Borg, M. H., Wen, S. W. C., Andersen, R. F., Timm, S., Hansen, T. F., & Hilberg, O. (2023) · Cancers · doi:10.3390/cancers15153959 · Cited by 27
Yang, Q., Huang, D., Wu, J., Zhong, H., Han, Y., Jiang, H., Chen, Y., Gong, C., Zhan, X., & Zhou, P. (2023) · European Radiology · doi:10.1007/s00330-023-10013-7 · Cited by 28
“The revised Quality Assessment of Diagnostic Accuracy Studies tool was employed to assess the constituent studies incorporated in the meta-analysis [30].”
Chen, Y., Zhao, W., Yi, S., & Liu, J. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1174080 · Cited by 28
Piccardo, A., Treglia, G., Fiz, F., Bar‐Sever, Z., Bottoni, G., Biassoni, L., Borgwardt, L., de Keizer, B., Jehanno, N., Lopci, E., et al. (2023) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-023-06486-9 · Cited by 25
Transcutaneous Bilirubin Accuracy Before, During, and After Phototherapy: A Meta-Analysis
ten Kate, L., van Oorschot, T., Woolderink, J., Teklenburg-Roord, S. T. A., & Bekhof, J. (2023) · PEDIATRICS · doi:10.1542/peds.2023-062335 · Cited by 26
Pavone, M., Jochum, F., Lecointre, L., Fanfani, F., Scambia, G., Querleu, D., & Akladios, C. Y. (2024) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-2023-005134 · Cited by 27
Torrez, S. L., Ayala, C. O., Ruggiro, P. B., Costa, C. A. D., Wagner, M. B., Padoin, A. V., & Mattiello, R. (2024) · Frontiers in Nutrition · doi:10.3389/fnut.2024.1284509 · Cited by 31
Abbreviated MRI for Hepatocellular Carcinoma Surveillance – A Systematic Review and Meta-analysis
Maung, S. T., Deepan, N., Decharatanachart, P., & Chaiteerakij, R. (2024) · Academic Radiology · doi:10.1016/j.acra.2024.01.028 · Cited by 26
Lee, Y.-C., Yeh, H.-T., Lu, S.-W., Tsai, Y.-C., Tsai, Y.-C., & Yen, C. (2024) · BMC Infectious Diseases · doi:10.1186/s12879-024-09174-7 · Cited by 33
Liu, Y., Qin, S.-B., Lan, C., Huang, Q., Zhang, P., & Cao, W. (2024) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2024.106996 · Cited by 26
Buono, A. D., Faita, F., Armuzzi, A., Jairath, V., Peyrin‐Biroulet, L., Danese, S., & Allocca, M. (2025) · Journal of Crohn s and Colitis · doi:10.1093/ecco-jcc/jjaf023 · Cited by 28
Liu, B., Zheng, Y., Shan, Q., Lu, Y., Lin, M., Tian, W., & Xie, X. (2015) · Journal of Medical Ultrasonics · doi:10.1007/s10396-015-0658-9 · Cited by 25
Thornton, H. V., Blair, P. S., Lovering, A. M., Muir, P., & Hay, A. D. (2015) · British Journal of General Practice · doi:10.3399/bjgp15x683497 · Cited by 25
Analysis of circulating microRNA biomarkers for breast cancer detection: a meta-analysis
Liu, L., Wang, S., Cao, X., & Liu, J. (2014) · Tumor Biology · doi:10.1007/s13277-014-2533-5 · Cited by 26
Liu, Y., Wu, H.-Y., Xiang, Y., Xu, H., Chen, D., Huang, Q. Y., & Fu, W. (2014) · Scientific Reports · doi:10.1038/srep07521 · Cited by 29
Predictive power of circulating miRNAs in detecting colorectal cancer
Zeng, W., Tu, Y., Zhu, Y., Wang, Z., Li, C., Lao, L., & Wu, G. (2014) · Tumor Biology · doi:10.1007/s13277-014-2872-2 · Cited by 30
Lee, C. I., Gold, L. S., Nelson, H. D., Chou, R., Ramsey, S. D., & Sullivan, S. D. (2014) · The Breast · doi:10.1016/j.breast.2014.11.009 · Cited by 25
Quality of reporting of studies evaluating time to diagnosis: a systematic review in paediatrics
Launay, E., Morfouace, M., Deneux‐Tharaux, C., Guen, C. G., Ravaud, P., & Chalumeau, M. (2013) · Archives of Disease in Childhood · doi:10.1136/archdischild-2013-304778 · Cited by 25
Gomes, C. M., Mazin, S. C., dos Santos, E. R., Cesetti, M. V., Bächtold, G. A. B., Cordeiro, J. H. D. F., Theodoro, F. C. E. T., Damasco, F. D. S., Vernal, S., Santos, A. D. O., et al. (2015) · Memórias do Instituto Oswaldo Cruz · doi:10.1590/0074-02760140280 · Cited by 25
Thombs, B. D., Roseman, M., & Kloda, L. A. (2012) · Systematic Reviews · doi:10.1186/2046-4053-1-58 · Cited by 26
Clinical Diagnostic Implications of Body Fluid MiRNA in Oral Squamous Cell Carcinoma
Tian, X., Chen, Z., Shi, S., Wang, X., Wang, W., Li, N., & Wang, J. (2015) · Medicine · doi:10.1097/md.0000000000001324 · Cited by 25
“The QUADAS-2 tool contains 4 key domains: patient selection, index test, reference standard, and flow and timing, which gives a maximum score of 7.(17) This tool is especially used to evaluate the quality of diagnostic accuracy of included studies.”
MiR-16 family as potential diagnostic biomarkers for cancer: a systematic review and meta-analysis.
Cui, J. (2015) · PubMed · Cited by 25
Wang, Z., Hu, Y., Wang, Y., Han, W., Wang, L., Xue, F., Sui, X., Song, W., Shi, R., & Jiang, J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0164416 · Cited by 25
Plasma fibrin D-dimer and the risk of left atrial thrombus: A systematic review and meta-analysis
Wan, H., Wu, S., Yang, Y., Zhu, J., Zhang, A., & Liang, Y. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172272 · Cited by 27
Accuracy of high b-value diffusion-weighted MRI for prostate cancer detection: a meta-analysis
Godley, K. C., Syer, T., Toms, A. P., Smith, T. O., Johnson, G., Cameron, D., & Malcolm, P. N. (2017) · Acta Radiologica · doi:10.1177/0284185117702181 · Cited by 25
Vogel, A. P., Rommel, N., Sauer, C., Horger, M. S., Krumm, P., Himmelbach, M., & Synofzik, M. (2017) · Journal of Neurology · doi:10.1007/s00415-017-8499-7 · Cited by 27
Eguchi, H., Horita, N., Ushio, R., Kato, I., Nakajima, Y., Ota, E., & Kaneko, T. (2017) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2017.05.009 · Cited by 28
Chi, S., Shen, L., Teng, H., Liu, S., Zhuang, G., Wang, X., Zhou, X., Wang, G., & Wang, H. (2017) · Oncotarget · doi:10.18632/oncotarget.18323 · Cited by 25
Schols, A. M. R., Stakenborg, J., Dinant, G., Willemsen, R. T. A., & Cals, J. (2017) · Family Practice · doi:10.1093/fampra/cmx066 · Cited by 25
Zhang, M., He, Y., Zhang, X., Zhang, M., & Kong, L. (2017) · Biomedical Reports · doi:10.3892/br.2017.970 · Cited by 25
Diagnostic accuracy of anorectal manometry for fecal incontinence: a meta-analysis
Yeap, Z. H., Simillis, C., Qiu, S., Ramage, L., Kontovounisios, C., & Tekkis, P. P. (2017) · Acta chirurgica Belgica · doi:10.1080/00015458.2017.1394674 · Cited by 25
Tan, E. H., Low, E. X. S., Dan, Y. Y., & Tai, B. C. (2018) · Liver International · doi:10.1111/liv.13646 · Cited by 24
Chen, L., Zhu, Z., Wang, Z.-T., Liang, L., Liang, L., JIN, J.-Y., & Wang, Z. (2017) · European Radiology · doi:10.1007/s00330-017-5141-0 · Cited by 27
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [25] was used to extract the appropriate study design characteristics from each study, and consisted of 11 items: each was answered with Byes^, Bno^, or Bunknown^.”
Xia, J., Zhang, H., Hu, Q., Liu, S., Zhang, L., Zhang, A., Zhang, X., Wang, Y., & Liu, A.-G. (2017) · Current Medical Science · doi:10.1007/s11596-017-1785-x · Cited by 25
A Comparative Analysis of the ADOS-G and ADOS-2 Algorithms: Preliminary Findings
Dorlack, T. P., Myers, O., & Kodituwakku, P. W. (2018) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-018-3475-3 · Cited by 26
Cantoni, V., Sollini, M., Green, R., Berchiolli, R. N., Lazzeri, E., Mannarino, T., Acampa, W., & Erba, P. A. (2018) · Clinical and Translational Imaging · doi:10.1007/s40336-018-0265-z · Cited by 29
Clinical usefulness of the SAMe-TT2R2 score: A systematic review and simulation meta-analysis
van Miert, J. H. A., Bos, S., Veeger, N. J. G. M., & Meijer, K. (2018) · PLoS ONE · doi:10.1371/journal.pone.0194208 · Cited by 25
“We rated the overall quality of evidence using the revised Tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2 [15]; see S2 Table).”
Baron, B. J., Benabbas, R., Kohler, C., Biggs, C., Roudnitsky, V., Paladino, L., & Sinert, R. H. (2018) · Academic Emergency Medicine · doi:10.1111/acem.13380 · Cited by 25
Choi, J., Cho, Y., & Woo, H. (2018) · JMIR mhealth and uhealth · doi:10.2196/mhealth.8554 · Cited by 29
Li, J., Wang, T., Jin, B., Li, W., Wang, Z., Zhang, H., Song, Y., & Li, N. (2018) · The International Journal of Biological Markers · doi:10.1177/1724600818784409 · Cited by 26
Guo, Y., Wang, L., Hu, J., Feng, D., & Xu, L. (2018) · PLoS ONE · doi:10.1371/journal.pone.0203400 · Cited by 27
Tai, Q., Yi, H., Wei, X., Xie, W., Zeng, O., Zheng, D., Sun, J., Wang, G., Wang, S., & Liu, G. (2018) · Journal of Intensive Care Medicine · doi:10.1177/0885066618807124 · Cited by 25
Evidence-Based Practice Guideline for Surgical Treatment of Gastroesophageal Reflux Disease 2018
Seo, H. S., Choi, M., Son, S., Kim, M. G., Han, D., & Lee, H. H. (2018) · Journal of the Korean Gastric Cancer Association · doi:10.5230/jgc.2018.18.e41 · Cited by 28
Diagnostic Accuracy of MRI-Based Sacroiliitis Scoring Systems: A Systematic Review
Swami, V. G., Jaremko, J. L., Rumsey, D. G., Stimec, J., Tse, S. M. L., Otobo, T. M., Adams-Webber, T., & Doria, A. S. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.17.19429 · Cited by 26
The diagnostic value of circulating tumor cells and ctDNA for gene mutations in lung cancer
Lyu, M., Zhou, J. H., Kang, N., & Ying, B. (2019) · OncoTargets and Therapy · doi:10.2147/ott.s195342 · Cited by 29
Hu, X., Huang, X., Chen, H., Zhang, T., Hou, J., Song, A., Ding, L., Liu, W., Wu, H., & Meng, F. (2019) · BMC Gastroenterology · doi:10.1186/s12876-019-0976-2 · Cited by 30
Xiong, Y., Tan, J., Liu, Y., Li, Y., You, F., Zhang, M., Chen, Q., Zou, K., & Sun, X. (2019) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2019.06.006 · Cited by 25
Park, S., & Park, Y. (2019) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000412 · Cited by 25
Routine screening of ACEs: should we or shouldn’t we?
McLennan, J. D., McTavish, J. R., & MacMillan, H. L. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816065-7.00008-2 · Cited by 30
Edwards, G., Freeman, K., Llewelyn, M., & Hayward, G. (2020) · BMJ · doi:10.1136/bmj.m54 · Cited by 25
Sjögren Syndrome in Primary Salivary Gland Lymphoma
Travaglino, A., Giordano, C., Pace, M., Varricchio, S., Picardi, M., Pane, F., Staibano, S., & Mascolo, M. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaa005 · Cited by 25
He, Y., Wang, Y., Li, Z., Chen, H., Deng, J., Huang, H., He, X., Zeng, W., Liu, M., Huang, B., et al. (2020) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13842 · Cited by 28
Neuteboom, O. B., Heldeweg, M. L. A., Pisani, L., Smit, M. R., Lagrand, W. K., Cherpanath, T. G. V., Dondorp, A. M., Schultz, M. J., & Tuinman, P. R. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.02.014 · Cited by 25
Diagnostic value of ultrasound-guided needle biopsy in undiagnosed pleural effusions
Lin, Z., Wu, D., Wang, J., Wang, C., & Huang, M. (2020) · Medicine · doi:10.1097/md.0000000000021076 · Cited by 25
Jiang, J., Yang, J., Shi, Y., Jin, Y., Tang, S., Zhang, N., Lu, Y., & Sun, G. (2020) · Scandinavian Journal of Infectious Diseases · doi:10.1080/23744235.2020.1788222 · Cited by 26
Meta‐analysis of differentially expressed microRNAs in systemic sclerosis
Zhang, L., Wu, H., Zhao, M., & Lu, Q. (2020) · International Journal of Rheumatic Diseases · doi:10.1111/1756-185x.13924 · Cited by 25
Rjoob, K. W. Y., Bond, R., Finlay, D., McGilligan, V., Leslie, S. J., Rababah, A., Guldenring, D., Iftikhar, A., Knoery, C., McShane, A., et al. (2020) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2020.08.013 · Cited by 25
Lacorte, E., Bellomo, G., Nuovo, S., Corbo, M., Vanacore, N., & Piscopo, P. (2020) · The Cerebellum · doi:10.1007/s12311-020-01210-x · Cited by 27
Gupta, T., Manjali, J. J., Kannan, S., Purandare, N. C., & Rangarajan, V. (2021) · Clinical Lymphoma Myeloma & Leukemia · doi:10.1016/j.clml.2021.03.011 · Cited by 26
Rapid-sequence MRI for evaluation of pediatric traumatic brain injury: a systematic review
Kessler, B. A., Goh, J. L., Pajer, H. B., Asher, A. M., Northam, W. T., Hung, S., Selden, N. R. W., & Quinsey, C. S. (2021) · Journal of Neurosurgery Pediatrics · doi:10.3171/2021.2.peds20852 · Cited by 25
“16 The RSMRI protocols were summarized based on the MRI and acceleration techniques.”
Manzotti, C., Casazza, G., Štimac, T., Nikolova, D., & Gluud, C. N. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012546 · Cited by 27
Dariane, C., Ploussard, G., Barret, É., Beauval, J., Brureau, L., Créhange, G., Fromont, G., Gauthé, M., Mathiéu, R., Renard‐Penna, R., et al. (2022) · World Journal of Urology · doi:10.1007/s00345-022-04087-z · Cited by 25
Shen, H., Gao, W., Cheng, J.-J., Zhao, S., Sun, Y., Han, Z., & Hua, J. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.06.017 · Cited by 27
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.