QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 7,501–7,600 of 14,770
Liu, Y., Ye, X., Zhang, N., Zhang, B., Guo, C., Huang, W., Jing, L., Wang, M., Yang, G., Wei, X., et al. (2015) · Prenatal Diagnosis · doi:10.1002/pd.4626 · Cited by 12
Menke, J. (2014) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.12173 · Cited by 14
Yang, J., Li, J., Zhu, R., Zhang, H., Zheng, Y., Dai, W., Wang, F., Shen, M., Chen, K., Cheng, P., et al. (2014) · Disease Markers · doi:10.1155/2014/573783 · Cited by 12
Henschke, N., Keuerleber, J., Ferreira, M. L., Maher, C. G., & Verhagen, A. P. (2014) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.11.008 · Cited by 15
A systematic review of the PTSD Checklist’s diagnostic accuracy studies using QUADAS.
McDonald, S. D., Brown, W. L., Benesek, J., & Calhoun, P. S. (2015) · Psychological Trauma Theory Research Practice and Policy · doi:10.1037/tra0000001 · Cited by 13
Wei, C., Wen-En, L., Yang-Ming, L., Shan, L., & Yi-Ming, Z. (2015) · PubMed Central · doi:10.5114/aoms.2015.54846 · Cited by 11
“To assess trial methodology, included publications were reviewed independently by two authors and given a quality score by using the QUADAS (quality assessment for studies of diagnostic accuracy, an evidence-based quality assessment tool to be used in systematic reviews of diagnostic accuracy studies, maximum score 14…”
Monothermal Caloric Screening Test Accuracy
Adams, M. E., Telian, S. A., Kane, R. L., & Butler, M. E. (2016) · Otolaryngology · doi:10.1177/0194599816630963 · Cited by 12
Suwanpasu, S., & Sattayasomboon, Y. (2016) · Journal of Intensive and Critical Care · doi:10.21767/2471-8505.100029 · Cited by 12
18F-FDG PET for diagnosing painful arthroplasty/prosthetic joint infection
Hao, R., Yuan, L., Kan, Y., & Yang, J. (2017) · Clinical and Translational Imaging · doi:10.1007/s40336-017-0237-8 · Cited by 12
Luo, M., Song, H., Liu, G., Lin, Y., Luo, L., Zhou, X., & Chen, B. (2017) · Oncotarget · doi:10.18632/oncotarget.21055 · Cited by 12
Pai, N. P., Chiavegatti, T., Vijh, R., Karatzas, N., Daher, J., Smallwood, M., Wong, T., & Engel, N. (2017) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0000000000000147 · Cited by 12
How to conduct a high-quality systematic review on diagnostic research topics
Yao, X., Vella, E. T., & Brouwers, M. C. (2017) · Surgical Oncology · doi:10.1016/j.suronc.2017.11.010 · Cited by 12
Frank, E. D., Ale‐Salvo, D., Park, J., Liu, Y., Simental, A., & Inman, J. C. (2018) · Head & Neck · doi:10.1002/hed.25111 · Cited by 12
Waterfield, T., Fairley, D., Lynn, F. A., Blackwood, B., & Shields, M. D. (2018) · Systematic Reviews · doi:10.1186/s13643-018-0747-0 · Cited by 12
“The risk of bias of each article will be evaluated independently by two investigators (TW, MDS) and reported according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [23].”
MethodCodorniu, A., Lemasle, L., Legrand, M. M., Blet, A., Mebazaa, A., & Gayat, É. (2018) · Biomarkers · doi:10.1080/1354750x.2018.1493616 · Cited by 12
Yao, C., Liu, H., Wu, H., Chen, Y., Yu, L., Fang, Y., Shen, X., & Liu, T. (2018) · Journal of Cancer · doi:10.7150/jca.25351 · Cited by 12
Reiman, M. P., Décary, S., Mathew, B., & Reiman, C. K. (2018) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2019.8476 · Cited by 12
Waterfield, T., Fairley, D., Blackwood, B., McKenna, J. P., & Shields, M. D. (2019) · BMC Pediatrics · doi:10.1186/s12887-019-1403-0 · Cited by 12
Gbinigie, O. A., Ordóñez-Mena, J. M., Fanshawe, T. R., Plüddemann, A., & Heneghan, C. J. (2019) · BMC Geriatrics · doi:10.1186/s12877-019-1061-y · Cited by 16
Device assisted enteroscopy in the elderly — A systematic review and meta-analysis
Zammit, S. C., Sanders, D. S., & Sidhu, R. (2019) · Digestive and Liver Disease · doi:10.1016/j.dld.2019.04.001 · Cited by 12
Accurate GFR in obesity—protocol for a systematic review
Sriperumbuduri, S., Dent, R., Malcolm, J., Hiremath, S. S., Klein, R., White, C. A., Brown, P. A., & Akbari, A. (2019) · Systematic Reviews · doi:10.1186/s13643-019-1052-2 · Cited by 17
Alabousi, M., Gauthier, I. D., Li, N., dos Santos, G. M., Golev, D., Patlas, M. N., & Alabousi, A. (2019) · Emergency Radiology · doi:10.1007/s10140-019-01696-x · Cited by 12
Luca, A. D., Mariani, M., Riccardi, M. T., & Damiani, G. (2019) · Open Access Emergency Medicine · doi:10.2147/oaem.s178544 · Cited by 12
McAleenan, A., Jones, H. E., Kernohan, A., Faulkner, C., Palmer, A., Dawson, S., Wragg, C., Jefferies, S., Brandner, S., Vale, L. D., et al. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013387 · Cited by 12
Parenti, N., Scalese, M., Palazzi, C., Agrusta, F., Cahill, J., & Agnelli, G. (2019) · PubMed Central · doi:10.6705/j.jacme.201906_9(2).0001 · Cited by 12
Accuracy of proton magnetic resonance for diagnosing non-alcoholic steatohepatitis: a meta-analysis
Kim, T., Jeong, C., Jun, H. Y., Lee, C., Noh, S.-H., Kim, J. E., Kim, S.-J., & Yoon, K. (2019) · Scientific Reports · doi:10.1038/s41598-019-51302-w · Cited by 15
Shen, L., Li, Y., Li, N., Zhao, Y., Zhou, Q., & Li, Z. (2019) · Cancer Medicine · doi:10.1002/cam4.2635 · Cited by 12
Jin, H., Lin, T., Han, P., Yao, Y., Zheng, D., Hao, J., Hu, Y., & Zeng, R. (2019) · Medicine · doi:10.1097/md.0000000000018066 · Cited by 14
Kim, D.-H., & Kim, S. (2020) · Clinical Imaging · doi:10.1016/j.clinimag.2020.04.030 · Cited by 15
Kuipers, H., Hoogwater, F. J. H., Holtman, G. A., van der Hoorn, A., de Boer, M. T., & de Haas, R. J. (2020) · Acta Radiologica · doi:10.1177/0284185120950115 · Cited by 12
Liang, X., & Xiang, J. (2020) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-020-01252-5 · Cited by 12
RetractedGibbs, N. M., & Weightman, W. M. (2020) · Anaesthesia and Intensive Care · doi:10.1177/0310057x20948868 · Cited by 12
Li, C., Ojeda‐Thies, C., Xu, C., & Trampuž, A. (2020) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-020-01864-7 · Cited by 12
Systematic review of diagnostic methods for acute respiratory distress syndrome
Hagens, L. A., Heijnen, N. F. L., Smit, M. R., Schultz, M. J., Bergmans, D. C. J. J., Schnabel, R. M., & Bos, L. D. J. (2021) · ERJ Open Research · doi:10.1183/23120541.00504-2020 · Cited by 9
Wang, L., & Li, J. (2021) · Journal of obstetrics and gynaecology research · doi:10.1111/jog.14681 · Cited by 13
Pinto, S. H. P. S., Huang, D. Y., Dinesh, A. A., Sidhu, P. S., & Ahmed, K. (2021) · Urology · doi:10.1016/j.urology.2021.02.012 · Cited by 12
Accuracy of clinical staging for T2N0 oesophageal cancer: systematic review and meta-analysis
Wolfson, P., Ho, K. M. A., Bassett, P., Haidry, R. J., Olivo, A., Lovat, L. B., & Sami, S. S. (2021) · Diseases of the Esophagus · doi:10.1093/dote/doab002 · Cited by 12
Saghir, S. M., Dhindsa, B. S., Daid, S. G. S., Mashiana, H. S., Dhaliwal, A., Cross, C. L., Singh, S., Bhat, I., Ohning, G., & Adler, D. G. (2021) · Endoscopic Ultrasound · doi:10.4103/eus-d-20-00122 · Cited by 13
Slot, S., van de Donk, N. W. C. J., Otten, R. H. J., Boden, B. J. H., Zijlstra, J. M., Raijmakers, P. G. H. M., & Zweegman, S. (2021) · Cancer Imaging · doi:10.1186/s40644-021-00405-7 · Cited by 12
Systematic Review of Diagnostic Sensors for Intra-Abdominal Pressure Monitoring
Liao, C., Cheng, C., Chen, C.-C., Wang, Y.-H., Chiu, H.-T., Peng, C.-C., Jow, U.-M., Lai, Y.-L., Chen, Y.-C., & Ho, D. (2021) · Sensors · doi:10.3390/s21144824 · Cited by 12
Li, W., Dong, A., Hong, G., Shang, W., & Shen, X. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109896 · Cited by 13
Can Ultrasound Elastography Discriminate between Rectal Adenoma and Cancer? A Systematic Review
Loft, M. K., Pedersen, M. R. V., Rahr, H. B., & Rafaelsen, S. R. (2021) · Cancers · doi:10.3390/cancers13164158 · Cited by 12
Trevisan, C., Damme, I. V., Ngowi, B. J., Schmidt, V., Stelzle, D., Møller, K. S., Kabululu, M. L., Makasi, C. E., Magnussen, P., Bottieau, E., et al. (2021) · Diagnostics · doi:10.3390/diagnostics11091528 · Cited by 13
Zhou, Q., Liu, J., Chen, S.-C., Xu, W., Han, Y., & Yin, Y.-P. (2021) · Antibiotics · doi:10.3390/antibiotics10091027 · Cited by 12
Ali, H., Pamarthy, R., Sarfraz, S., & Ali, E. (2021) · Cureus · doi:10.7759/cureus.17560 · Cited by 18
Nasopharyngeal versus nasal swabs for detection of SARS-CoV-2: a systematic review
Gadenstaetter, A. J., Mayer, C. D., & Landegger, L. D. (2021) · Rhinology Journal · doi:10.4193/rhin21.162 · Cited by 14
“Risk of bias within the included studies was assessed using the validated Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, which judges possible bias in four different domains: 1) patient selection, 2) index test, 3) reference standard, and 4) flow and timing (31) .”
Bakogiannis, C., Mouselimis, D., Tsarouchas, A., Papatheodorou, E., Vassilikos, V. P., & Androulakis, E. S. (2021) · European Journal of Sport Science · doi:10.1080/17461391.2021.2001576 · Cited by 12
Qin, S., Sun, N., Xu, L., Xu, Y., Tang, Q., Tan, L., Chen, A., Zhang, L., & Liu, S. (2021) · Reproductive Sciences · doi:10.1007/s43032-021-00799-6 · Cited by 12
Heo, S., Kim, D. W., Choi, S. H., Kim, S. W., & Jang, J. K. (2022) · European Radiology · doi:10.1007/s00330-021-08436-1 · Cited by 12
Flores, G. L., da Mota, J. C., Andrade, L. T. D. S., Lopes, R. S., Bastos, F. I., & Villar, L. M. (2022) · BioMed Research International · doi:10.1155/2022/7348755 · Cited by 12
“We used the QUADAS-2 standard (Evaluation of the Quality of Diagnostic accuracy studies 2) to assess the quality and risk of bias in the included studies [17].”
Clonality, Mutation and Kaposi Sarcoma: A Systematic Review
Ruiz, B. I. I., Armon, S., Watanabe, R., Uttley, L., White, V. A., Lazar, A. J., & Cree, I. A. (2022) · Cancers · doi:10.3390/cancers14051201 · Cited by 12
Park, S. H. (2022) · Korean Journal of Radiology · doi:10.3348/kjr.2021.0963 · Cited by 13
Philip, M. R., & Alfotawi, R. A. (2022) · Oral and Maxillofacial Surgery · doi:10.1007/s10006-022-01059-w · Cited by 12
Mazrani, W., Cook, G., & Bomanji, J. B. (2022) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001557 · Cited by 12
Chen, W., Fang, L.-X., Chen, H., & Zheng, J. (2022) · World Journal of Clinical Cases · doi:10.12998/wjcc.v10.i11.3436 · Cited by 12
Rapid diagnostic tests for plague
Jullien, S., Dissanayake, H. A., & Chaplin, M. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013459 · Cited by 12
Chan, C. C., Fage, B. A., Smailagic, N., Gill, S. S., Herrmann, N., Nikolaou, V., & Seitz, D. P. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011414 · Cited by 12
Lee, S. J., Kim, D., Suh, C. H., Heo, H., Shim, W. H., & Kim, S. J. (2022) · European Radiology · doi:10.1007/s00330-022-08845-w · Cited by 12
Santoro, A., Angelico, G., Travaglino, A., Inzani, F. S., Arciuolo, D., Valente, M., D’Alessandris, N., Scaglione, G., Piermattei, A., Cianfrini, F., et al. (2022) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2022.06.031 · Cited by 12
Clinical Applications of Immuno-PET in Lymphoma: A Systematic Review
Triumbari, E. K. A., Morland, D., Laudicella, R., Bauckneht, M., Albano, D., & Annunziata, S. (2022) · Cancers · doi:10.3390/cancers14143488 · Cited by 12
Liu, X., Jiang, T., Gao, C., Liu, H., Sun, Y., Zou, Q., Tang, R., & Zeng, W. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.911146 · Cited by 12
Dansero, L., Ricceri, F., Marco, L. D., Fiano, V., Nesi, G., Padroni, L., Milani, L., Caini, S., Masala, G., Agnoli, C., et al. (2022) · Biomedicines · doi:10.3390/biomedicines10092224 · Cited by 12
Balakrishnan, B., Owens, B., Hayes, R., & Wen, S. (2022) · Cureus · doi:10.7759/cureus.32185 · Cited by 12
Zangiabadian, M., Ghorbani, A., Nojookambari, N. Y., Ahmadbeigi, Y., Hosseini, S. S., Karimi-Yazdi, M., Goudarzi, M., Chirani, A. S., & Nasiri, M. J. (2022) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2022.106657 · Cited by 13
van Leeuwen, F. H. P., Timmer, M. A., de Jong, P. A., Fischer, K., & Foppen, W. (2023) · Haemophilia · doi:10.1111/hae.14737 · Cited by 12
Assessing Metabolic Markers in Glioblastoma Using Machine Learning: A Systematic Review
Neil, Z. D., Pierzchajlo, N., Boyett, C., Little, O., Kuo, C.-C. J., Brown, N. J., & Gendreau, J. L. (2023) · Metabolites · doi:10.3390/metabo13020161 · Cited by 11
Kohil, A., Abdallah, A. M., Hussain, K., & Al-Shafai, M. N. (2023) · Orphanet Journal of Rare Diseases · doi:10.1186/s13023-023-02614-8 · Cited by 12
Sijbrandij, M., Reitsma, J. B., Roberts, N. P., Engelhard, I. M., Olff, M., Sonneveld, L. P., & Bisson, J. I. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010575 · Cited by 13
Self-citationFu-bin, Y., Guo, W., Sheng, M., Sun, L., Ding, Y., Xu, Q., Xu, M., & Lv, H. (2015) · Saudi Medical Journal · doi:10.15537/smj.2015.10.12415 · Cited by 12
Circulating MicroRNA as Potential Source for Neurodegenerative Diseases Biomarkers
Zi, Y., Yin, Z., Xiao, W., Liu, X., Gao, Z., Li, J., & Deng, L. (2014) · Molecular Neurobiology · doi:10.1007/s12035-014-8944-x · Cited by 12
The creation of the diagnostic accuracy quality scale (DAQS)
Cook, C. E., Cleland, J. A., Hegedus, E. J., Wright, A. A., & Hancock, M. J. (2013) · Journal of Manual & Manipulative Therapy · doi:10.1179/2042618613y.0000000032 · Cited by 12
E. multilocularis infection in animals
Casulli, A., Possenti, A., Torre, G. L., Boué, F., Busani, L., Colamesta, V., Conraths, F. J., D'Aguanno, S., Giusti, M. D., Vito, C. D., et al. (2015) · EFSA Supporting Publications · doi:10.2903/sp.efsa.2015.en-882 · Cited by 13
Mizer, A., Bachmann, A., Gibson, J., & Donaldson, M. B. (2017) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2017.06.002 · Cited by 12
Diagnostic accuracy of DNA methylation in detection of gastric cancer: a meta-analysis
Hu, W., Zheng, W., Liu, Q., Chu, H., Chen, S., Kim, J. J., Wu, J., & Si, J. (2017) · Oncotarget · doi:10.18632/oncotarget.22613 · Cited by 12
Zhang, R., Zhang, L., Yang, M., Huang, L., Chen, G., & Feng, Z. (2017) · Molecular Medicine Reports · doi:10.3892/mmr.2017.8167 · Cited by 14
Jeong, S., Yang, D., Lee, W., Kim, G.-T., Kim, H.-S., Ahn, H. S., & Kim, H. J. (2018) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2018.01.011 · Cited by 12
Piyasena, P., Murthy, G. V. S., Gilbert, C. E., Yip, J. L. Y., Pető, T., Macleod, D., Fonseka, C., Kulatunga, A., Bandutilake, B. G. W. M. K. C. B., Dhanapala, M., et al. (2018) · JMIR Research Protocols · doi:10.2196/10900 · Cited by 14
“The results of this study will be published in detail according to the Quality Assessment of Diagnostic Accuracy Study guidelines [26].”
Cell-free DNA and preoperative chemoradiotherapy for rectal cancer: a systematic review
Boysen, A. K., Schou, J. V., & Spindler, K. G. (2018) · Clinical & Translational Oncology · doi:10.1007/s12094-018-1997-y · Cited by 12
Seligman, H., Shun-Shin, M. J., Vasireddy, A., Cook, C., Ahmad, Y., Howard, J. P., Sen, S., Al-Lamee, R. K., Nijjer, S. S., Chamié, D., et al. (2019) · Open Heart · doi:10.1136/openhrt-2018-000971 · Cited by 12
Pruijn, N., Schuncken, A. C., Kosse, N. M., Hofstad, C. J., & Dorrestijn, O. (2020) · Shoulder & Elbow · doi:10.1177/1758573220913243 · Cited by 12
Involvement of Helicobacter Pylori in Ocular Adnexa Lymphoma
Travaglino, A., Pace, M., Varricchio, S., Russo, D., Pugliese, N., Severino, A., Picardi, M., Pane, F., Insabato, L., Staibano, S., et al. (2020) · Pathology & Oncology Research · doi:10.1007/s12253-020-00848-6 · Cited by 12
Lozano, F., Raventos, C. X., Carrión, A., Trilla, E., & Moróte, J. (2020) · BMC Urology · doi:10.1186/s12894-020-00670-x · Cited by 15
Meyer, J. E., Bartolomei, C., Sauer, A., Sajatovic, M., & Bailey, C. M. (2020) · Brain Injury · doi:10.1080/02699052.2020.1802780 · Cited by 12
Burr, M. R., Naze, G. S., Shaffer, S. M., & Kavchak, A. J. E. (2020) · Journal of Oral Rehabilitation · doi:10.1111/joor.13127 · Cited by 17
Blinding practices during acute point-of-care ultrasound research: the BLIND-US meta-research study
Prager, R. T., Wu, K., Bachar, R., Unni, R. R., Bowdridge, J., McGrath, T. A., Thavanathan, R., Woo, M. Y., & McInnes, M. D. F. (2020) · BMJ Evidence-Based Medicine · doi:10.1136/bmjebm-2020-111577 · Cited by 12
Letzkus, L., Fehlings, D. L., Ayala, L., Byrne, R., Gehred, A. P., Maitre, N. L., Noritz, G. H., Rosenberg, N. S., Tanner, K. J., Vargus‐Adams, J. N., et al. (2021) · Journal of Child Neurology · doi:10.1177/0883073821996916 · Cited by 13
Preoperative Lung Ultrasound to Detect Pleural Adhesions: A Systematic Review and Meta-Analysis
Shiroshita, A., Nakashima, K., Takeshita, M., & Kataoka, Y. (2021) · Cureus · doi:10.7759/cureus.14866 · Cited by 12
Supporting self-management in early dementia: a contribution towards ‘living well’?
Cheffey, J., Hill, L., Roberts, G. A., & Marlow, R. (2013) · Advances in Psychiatric Treatment · doi:10.1192/apt.bp.112.011023 · Cited by 12
Lee, J. W., Nam, S. B., & Kim, S. (2019) · Oncology · doi:10.1159/000501398 · Cited by 12
Davis, D. H. J., Creavin, S., Yip, J. L. Y., Noel-Storr, A. H., Brayne, C., & Cullum, S. J. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010775 · Cited by 10
Guay, J. M. Y., & Kopp, S. L. (2018) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2018.01.011 · Cited by 12
Dopamine transporter imaging for the diagnosis of dementia with Lewy bodies
McCleery, J. M., Morgan, S., Hyde, C., Bradley, K. M., & Ansorge, O. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010633 · Cited by 12
Applications of artificial intelligence in vasculitides: a systematic review
Omar, M., Agbareia, R., Naffaa, M. E., Watad, A., Glicksberg, B. S., Nadkarni, G. N., & Klang, E. (2025) · ACR Open Rheumatology · doi:10.1002/acr2.70016 · Cited by 11
Novel Screening and Monitoring Techniques for Deformational Plagiocephaly: A Systematic Review
Watt, A., Zammit, D., Lee, J., & Gilardino, M. S. (2022) · PEDIATRICS · doi:10.1542/peds.2021-051736 · Cited by 12
Karisani, N., Aminimoghaddam, S., Kashanian, M., Baradaran, H. R., & Moradi, Y. (2022) · Health Care For Women International · doi:10.1080/07399332.2021.1998059 · Cited by 13
Li, W., Cheung, R., & Malvankar‐Mehta, M. S. (2022) · Journal of American Association for Pediatric Ophthalmology and Strabismus · doi:10.1016/j.jaapos.2021.12.006 · Cited by 12
Al-Kaylani, A. H. A. Z., Schuurmann, R. C. L., Maathuis, W. D., Slart, R. H. J. A., de Vries, J. P. P. M., & Bokkers, R. P. H. (2022) · Diagnostics · doi:10.3390/diagnostics13010128 · Cited by 11
Padroni, L., Marco, L. D., Dansero, L., Fiano, V., Milani, L., Vasapolli, P., Manfredi, L., Caini, S., Agnoli, C., Ricceri, F., et al. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24043910 · Cited by 12
Beaufort, I. N., Akkerman, E., van Munster, S. N., & Weusten, B. L. A. M. (2023) · Endoscopy International Open · doi:10.1055/a-1967-1589 · Cited by 11
Bowden, S. J., Ellis, L. B., Kalliala, I. E. J., Paraskevaidi, M., Tighe, J., Kechagias, K. S., Doulgeraki, T., Paraskevaidis, E. A., Arbyn, M., Flanagan, J. M., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-071534 · Cited by 11
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.