In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 7,801–7,900 of 14,770
Park, E. J., Son, J. H., & Choi, S. H. (2022) · Abdominal Radiology · doi:10.1007/s00261-022-03499-0 · Cited by 14
Cozzolino, A., Filardi, T., Simonelli, I., Grani, G., Virili, C., Stramazzo, I., Santaguida, M. G., Locantore, P., Maurici, M., Gianfrilli, D., et al. (2022) · European Thyroid Journal · doi:10.1530/etj-22-0039 · Cited by 11
C-reactive protein for diagnosing late-onset infection in newborn infants
Brown, J. V. E., Meader, N., Cleminson, J. S., & McGuire, W. L. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012126 · Cited by 11
Sun, C., Zhang, Y., Han, X., & Du, X. (2018) · Otolaryngology · doi:10.1177/0194599818758302 · Cited by 11
Zhang, W., Wang, Y. J., Yao, Y., Zhang, G. X., Zhang, Y. N., & Gao, S. (2022) · Neurología · doi:10.1016/j.nrl.2022.03.002 · Cited by 11
Wu, J., Li, Z., Zou, J., Li, L., Cui, N., Hao, T., Yi, K., Yang, J., & Wu, Y. (2022) · PLoS ONE · doi:10.1371/journal.pone.0274282 · Cited by 11
Efficacy of Imaging Methods in the Detection and Diagnosis of Cerebrospinal Fluid Rhinorrhea
Hwang, S. H., Kim, S. W., & Kim, D. H. (2022) · The Laryngoscope · doi:10.1002/lary.30388 · Cited by 11
Hua, K.-F., Wu, Y., & Zhang, S.-T. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.1032070 · Cited by 11
Cao, R., Chen, B., Xu, H. X., Cai, Y., & Liu, W. (2022) · Medicine · doi:10.1097/md.0000000000031922 · Cited by 11
Ferreira, F. B. M. D., Puchnick, A., Garcia, D. A. L., Regacini, R., Perez, P. D. T. K., Pinto, M. B. R., Guimarães, J. B., & Fernandes, A. D. R. C. (2022) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2022.12.467 · Cited by 11
Ahmadi, S., Dizaji, S. R., Babahajian, A., Alizadeh, M., Sarveazad, A., & Yousefifard, M. (2023) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v11i1.1682 · Cited by 14
“using the Quality Assessment of Diagnostic Accuracy Studies Version 2 (QUADAS-2) tool (18).”
Boer, G. J., van Engen, L., van Dam, L., van de Luijtgaarden, K. M., Bokkers, R. P. H., de Vries, J. P. P. M., & Fioole, B. (2023) · Diagnostics · doi:10.3390/diagnostics13050829 · Cited by 11
Accuracy of Raman spectroscopy in the diagnosis of Alzheimer's disease
Xu, Y., Pan, X., Li, H., Cao, Q., Xu, F., & Zhang, J. (2023) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2023.1112615 · Cited by 14
Kisspeptin as a predictor of miscarriage: a systematic review
da Silva, P. H. A., Romão, L. G. D. M., de Freitas, N. P. A., Carvalho, T. R., Porto, M. E. M. P., Júnior, E. A., & Cavalcante, M. B. (2023) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2023.2197097 · Cited by 11
Wang, Y., Lo, C.-Y., Chen, L.-Y., Chang, C., Huang, Y.-T., Huang, Y.-Y., & Huang, Y.-H. (2023) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000004646 · Cited by 11
Radiomics; Contemporary Applications in the Management of Anal Cancer; A Systematic Review
Temperley, H. C., O’Sullivan, N. J., Waters, C., Corr, A., Mehigan, B. J., O'Kane, G. M., McCormick, P. H., Gillham, C., Rausa, E., Larkin, J. O., et al. (2023) · The American Surgeon · doi:10.1177/00031348231216494 · Cited by 14
da Rosa, M. I., Perucchi, J. L., Medeiros, L. R., Fernandes, B. B., dos Reis, M. E. F., & Silva, B. R. (2014) · Journal of Alzheimer s Disease · doi:10.3233/jad-132264 · Cited by 16
“[9].”
Byrne, A., Bennett, M. H., Pace, N. L., & Thomas, P. S. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010841 · Cited by 11
Buczinski, S., Fecteau, G., Chigerwe, M., & Vandeweerd, J. (2016) · Animal Health Research Reviews · doi:10.1017/s1466252316000074 · Cited by 11
Accuracy of transient elastography in the assessment of chronic hepatitis C-related liver cirrhosis
Ying, H.-Y., Lu, L., Jing, D.-D., & Ni, X. (2016) · Clinical and investigative medicine · doi:10.25011/cim.v39i5.27147 · Cited by 11
Urinary Protein Markers for the Detection and Prognostication of Urothelial Carcinoma
Szarvas, T., Nyírády, P., Ogawa, O., Furuya, H., Rosser, C. J., & Kobayashi, T. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7234-0_19 · Cited by 12
Gupta, R., Talwar, P., Talwar, P., Khurana, S., Kushwaha, S. S., Jalan, N., & Thakur, R. (2018) · Journal of Infection · doi:10.1016/j.jinf.2018.04.017 · Cited by 11
Goto, E. (2018) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.12517 · Cited by 11
MiR-139 in digestive system tumor diagnosis and detection: Bioinformatics and meta-analysis
Wang, Y.-H., Ji, J., Weng, H., Wang, B., & Wang, X. (2018) · Clinica Chimica Acta · doi:10.1016/j.cca.2018.06.006 · Cited by 13
New Technologies for Glaucoma Detection
Uña, I. R., & Azuara‐Blanco, A. (2018) · Asia-Pacific Journal of Ophthalmology · doi:10.22608/apo.2018349 · Cited by 17
Electrophysiological testing in concussion: A guide to clinical applications
Papathanasiou, E. S., Cronin, T., Seemungal, B. M., & Sandhu, J. S. (2018) · Journal of Concussion · doi:10.1177/2059700218812634 · Cited by 14
Pang, C., Ma, H., Qin, J., Wang, S., Wan, C., Yang, T., Shen, Y., & Wang, D. (2019) · Medicine · doi:10.1097/md.0000000000015450 · Cited by 13
Wickremeratne, T., Turner, S. B., & O’Beirne, J. P. (2019) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.15282 · Cited by 11
Berardino, S. D., Capolupo, G. T., Caricato, C., & Caricato, M. (2019) · Medicine · doi:10.1097/md.0000000000016310 · Cited by 12
Schafer, J. M., Welwarth, J., Novack, V., Balk, D., Beals, T., Naraghi, L., Khattab, E., & Hoffmann, B. (2019) · South African Medical Journal · doi:10.7196/samj.2019.v109i8.13783 · Cited by 11
Xie, T., Liu, Y., Liang, C., Huang, Y., Li, J., Li, Z., Fan, S.-J., Chen, J., Xia, Y., Li, X., et al. (2019) · Bioscience Reports · doi:10.1042/bsr20190859 · Cited by 13
Tu, X., Liu, Z., Zhang, C., Chang, T., Xu, H., Bao, Y., Li, J., Jin, K., Yuan, Q., Qiu, S., et al. (2019) · Urologia Internationalis · doi:10.1159/000504028 · Cited by 11
Zhu, W., Ling, X.-X., Shang, W., Du, Y., Liu, J., Cao, Y., Yang, M., Zhu, G., Cao, J., & Huang, J. (2020) · Journal of Global Health · doi:10.7189/jogh.10.010411 · Cited by 11
Hadjivasilis, A., Tzanis, A. Α., Ioakim, K. J., Poupoutsi, I., Agouridis, A. P., & Κouis, P. (2020) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000001813 · Cited by 11
Baldon, I. V., Amorim, A. C., Santana, L. M., Solla, D. J. F., Kolias, A. G., Hutchinson, P. J., Paiva, W. S., & Júnior, M. R. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235561 · Cited by 11
Noubiap, J. J., Agbaedeng, T. A., Nyaga, U. F., Nkoké, C., & Jingi, A. M. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13923 · Cited by 13
Travaglino, A., Raffone, A., Santoro, A., Gencarelli, A., Angelico, G., Spadola, S., Marzullo, L., Zullo, F., Insabato, L., & Zannoni, G. F. (2021) · Apmis · doi:10.1111/apm.13114 · Cited by 11
van Leeuwen, C. A. T., Krijnen, P., Hoogendoorn, J. M., & Schipper, I. B. (2021) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-021-03850-y · Cited by 11
Biological measures and diagnostic tools for Gulf War Illness – A systematic review
Gean, E. G., Ayers, C. K., Winchell, K. A., Freeman, M., Press, A. M., Paynter, R. A., Kansagara, D. L., & Nugent, S. M. (2021) · Life Sciences · doi:10.1016/j.lfs.2021.119360 · Cited by 11
de Carvalho, C. C., Neto, J. M. D. S., & de Orange, F. V. A. (2021) · Brazilian Journal of Anesthesiology (English Edition) · doi:10.1016/j.bjane.2021.06.015 · Cited by 12
Mincarone, P., Bodini, A., Tumolo, M. R., Vozzi, F., Rocchiccioli, S., Pelosi, G., Caselli, C., Sabina, S., & Leo, C. G. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047677 · Cited by 13
The potential diagnostic accuracy of circulating microRNAs for Alzheimer's disease: A meta-analysis
Zhang, W., Zhang, G. X., & Gao, S. (2021) · Neurología · doi:10.1016/j.nrl.2021.06.001 · Cited by 11
Wang, Y., Xu, Y., Kan, Y., Wang, W., & Yang, J. (2021) · Contrast Media & Molecular Imaging · doi:10.1155/2021/5333366 · Cited by 11
Diagnostic accuracy of clinical tests to rule out elbow fracture: a systematic review
Breda, G., Marco, G. D., Cesaraccio, P., & Pillastrini, P. (2022) · Clinics in Shoulder and Elbow · doi:10.5397/cise.2022.00948 · Cited by 11
Odenbach, J., Newton, A. S., Gokiert, R., Falconer, C., Courchesne, C., Campbell, S., & Curtis, S. J. (2014) · Systematic Reviews · doi:10.1186/2046-4053-3-19 · Cited by 11
Typical rise and fall of troponin in (peri-procedural) myocardial infarction: A systematic review
van Beek, D. E. C., van Zaane, B., Looije, M. F., Peelen, L. M., & van Klei, W. A. (2016) · World Journal of Cardiology · doi:10.4330/wjc.v8.i3.293 · Cited by 11
Probst, H., & Ramlaul, A. (2020) · Springer eBooks · doi:10.1007/978-3-030-37944-5_12 · Cited by 11
Vogel, R., Balzer, J. R., Gertsch, J. H., Holdefer, R. N., Lee, G. R., Moreira, J. J., Wilent, W. B., & Shils, J. L. (2018) · Neurosurgery · doi:10.1093/neuros/nyy093 · Cited by 11
Biomarker-Guided Imaging and AI-Augmented Diagnosis of Degenerative Joint Disease
Kumar, R., Sporn, K., Borole, A., Khanna, A., Gowda, C., Paladugu, P., Ngo, A., Jagadeesan, R., Zaman, N., & Tavakkoli, A. (2025) · Diagnostics · doi:10.3390/diagnostics15111418 · Cited by 13
de Pablo, P., Dinnes, J., Berhane, S., Osman, A., Lim, Z. N., Coombe, A., Raza, K., Filer, A. D., & Deeks, J. J. (2021) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2021.10.003 · Cited by 10
Self-citationDiagnostic accuracy of tests for tuberculous pericarditis: A network meta-analysis
Pervez, A., Hasan, S. U., Hamza, M., Asghar, S., Qaiser, M. H., Zaidi, S., & Mustansar, I. (2023) · Indian Journal of Tuberculosis · doi:10.1016/j.ijtb.2023.05.013 · Cited by 12
Klingberg, G., Benchimol, D., Berlin, H., Bring, J., Gornitzki, C., Odeberg, J., Tranæus, S., Twetman, S., Wernersson, E., Östlund, P., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285252 · Cited by 10
Mu, D., Ma, Y., Cheng, J. H., Qiu, L., Chen, S., & Cheng, X. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.05.006 · Cited by 12
Bhalla, D., Jana, M., & Kandasamy, D. (2023) · Pediatric Radiology · doi:10.1007/s00247-023-05775-7 · Cited by 10
Manco, L., Albano, D., Urso, L., Arnaboldi, M., Castellani, M., Florimonte, L., Guidi, G., Turra, A., Castello, A., & Panareo, S. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12247669 · Cited by 10
Pradi, N., Vieira, D. S. R., Ramalho, O., Lemes, Í. R., Cordeiro, E. C., Arpini, M., Hulzebos, E. H. J., Lanza, F. C., & Montemezzo, D. (2023) · Brazilian Journal of Physical Therapy · doi:10.1016/j.bjpt.2023.100587 · Cited by 10
Haara, S. R. T., de Rezende, H. A., & Wang, C. (2024) · Sultan Qaboos University medical journal · doi:10.18295/squmj.1.2024.007 · Cited by 13
Giampietro, R. R., Cabral, M. V. G., Pereira, E. G., Machado, M. C., Vilar, L., & Nogueira, V. D. S. N. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1332120 · Cited by 12
Klokman, V. W., Koningstein, F. N., Dors, J. W. W., Sanders, M. S., Koning, S. W., de Kleijn, D. P. V., & Jie, K. E. (2024) · Academic Emergency Medicine · doi:10.1111/acem.14864 · Cited by 10
Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis
Rivera, A. K. U., Seeliger, B., Goffin, L., Garcia-Vazquez, A., Mutter, D., & Giménez, M. (2024) · Annals of Surgery Open · doi:10.1097/as9.0000000000000406 · Cited by 10
Soman, C., Hawzah, A. A. A. A., Alsomali, M., Alghamdi, S., & ALOsaimi, M. M. (2024) · Annals of dental specialty · doi:10.51847/lnn8bswowj · Cited by 10
“While the studies were scrutinized for quality and inclusion, any disagreement among the investigators was mutually discussed and clarified, and an agreement was reached [20].”
Artificial Intelligence in Anterior Chamber Evaluation: A Systematic Review and Meta-Analysis
Olyntho, M. A. D. C., Jorge, C. A. C., Castanha, E. B., Gonçalves, A. N., da Silva, B., Nogueira, B. V., Lima, G. M., Gracitelli, C. P. B., & Tatham, A. J. (2024) · Journal of Glaucoma · doi:10.1097/ijg.0000000000002428 · Cited by 10
Tseriotis, V., Mavridis, T., Eleftheriadou, K., Konstantis, G., Chlorogiannis, D., Pavlidis, P., Pourzitaki, C., Arnaoutoglou, M., & Spyridon, K. (2024) · Journal of Neurology · doi:10.1007/s00415-024-12381-6 · Cited by 10
“For quality assessment, we utilized the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [22], provided in Review Manager (RevMan) 5.4.”
InfluentialAccuracy of 3D Printing in Orthodontics: A Systematic Review and Meta-analysis
Rajagopalan, A., Verma, S., Kumar, V., Verma, R. K., & Singh, S. P. (2024) · The Journal of Indian Orthodontic Society · doi:10.1177/03015742241253947 · Cited by 10
“9,12,33,34 Dental models printed with the PolyJet technology are fully cured during the building process and do not need a postcuring process, which leads to a faster and more efficient printing process.”
Tang, R., Liu, M., Shu, Q., Chen, X., & Cai, L. (2024) · European Radiology · doi:10.1007/s00330-024-10843-z · Cited by 11
“We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tools to evaluate the risk of bias and applicability for the studies included in this meta-analysis [15].”
Pelletti, G., Rafael Boscolo-berto, A., Anniballi, L., Giorgetti, A., Pirani, F., Cavallaro, M. C., Giorgini, L., Fais, P., Pascali, J. P., & Pelotti, S. (2024) · International Journal of Legal Medicine · doi:10.1007/s00414-024-03291-3 · Cited by 11
Wudhikulprapan, W., Phinyo, P., Hadi, A., Kanthawang, T., & Choudur, H. N. (2024) · Clinical Radiology · doi:10.1016/j.crad.2024.07.015 · Cited by 11
Shen, Y., & Yang, Y. (2024) · Clinical Imaging · doi:10.1016/j.clinimag.2024.110248 · Cited by 11
Connecting the dots – A systematic review on coherence analysis in dystonia
Lagerweij, S. A. J. E. A., Smit, M., Centen, L. M., van Dijk, J. M. C., van Egmond, M. E., Elting, J. W. J., & Tijssen, M. A. J. (2024) · Neurobiology of Disease · doi:10.1016/j.nbd.2024.106616 · Cited by 12
“The quality of the papers was assessed with the QUADAS-2 checklist as advised by the Cochrane Collaboration (Whiting et al., 2011).”
MethodLópez‐Lázaro, S., & Castillo-Alonso, C. (2024) · International Journal of Legal Medicine · doi:10.1007/s00414-024-03304-1 · Cited by 10
“The risk of bias was assessed using QUADAS-2, as sug - gested by the Cochrane Collaboration for Systematic Reviews [ 35].”
Sadava, E. E., Laxague, F., Valinoti, A. C., Angeramo, C. A., & Schlottmann, F. (2024) · Hernia · doi:10.1007/s10029-024-03142-5 · Cited by 10
Kapsali, I., Brinia, M.-E., & Constantinides, V. C. (2024) · Biomedicines · doi:10.3390/biomedicines12102266 · Cited by 12
Łajczak, P. M., Sirek, S., & Wyględowska‐Promieńska, D. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109350 · Cited by 11
de Vries, T. A. C., Mallick, I. U., Bhagirath, V. C., Eikelboom, J. W., Gomes, C., Yi, Q., McGrath, S., Hirsh, J., & Chan, N. (2024) · Thrombosis and Haemostasis · doi:10.1055/a-2446-1348 · Cited by 10
Yang, B., Dong, H., Zhang, S., Ming, S., Yang, R., Peng, Y., & Gao, X. (2024) · Academic Radiology · doi:10.1016/j.acra.2024.11.029 · Cited by 11
Systematic Review and Meta‐Analysis: Taurine and Its Association With Colorectal Carcinoma
Sinha, A., Griffith, L., & Acharjee, A. (2024) · Cancer Medicine · doi:10.1002/cam4.70424 · Cited by 12
“Risk of bias in the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) assessment tool [32].”
Valle, L. D., Piergianni, M., Khalil, A. A., Rizzo, G., Mappa, I., Matarrelli, B., Lucidi, A., Manzoli, L., Flacco, M. E., Stuppia, L., et al. (2024) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.29131 · Cited by 11
“Each item was scored as having high or low risk, except if there was insufficient information to make an accurate judgment, in which case the risk was deemed unclear 14 .”
Rosa, G. R. M. L., Angjelova, A., Jovanova, E., Apostolska, S., Santos, J. M., & Pedullá, E. (2024) · Odontology · doi:10.1007/s10266-024-01039-4 · Cited by 10
“Similarly, if two or more key domains are marked as unclear, the study is considered to have an “unclear risk” of bias [18].”
Becker, L. M., Peper, J., van Ginkel, D. J., Overduin, D. C., van Es, H. W., Rensing, B. J. M. W., Timmers, L., ten Berg, J. M., Hoesein, F. A. A. M., Leiner, T., et al. (2024) · European Radiology · doi:10.1007/s00330-024-11211-7 · Cited by 11
“Bias assessment was performed using the revised tool for Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [26].”
Wang, T., Hong, J., Lee, W., Lin, Y., Yang, H., Lee, C., Chen, H.-C., Wu, H., You, W.-C., & Wu, Y. (2024) · Neuroinformatics · doi:10.1007/s12021-024-09704-3 · Cited by 11
Bisschop, J. M., de Jonge, H. J. M., Brunsveld‐Reinders, A. H., van de Mheen, D., Mathijssen, J. J. P., & Rozema, A. D. (2025) · Drug and Alcohol Review · doi:10.1111/dar.13987 · Cited by 12
“Finally, performing the risk of bias assessment using the QUADAS-2 tool showed that the greatest inconsistency was in blinding the results, which may have led to bias related to sub-jectivity [24].”
Zahwe, M., Ghzaiel, A., Najia, A., Soueid, L., Asmar, K. E., Ghezzawi, M., Iskandarani, S. E., Diab, M., Jibbawi, M. E., Hoteit, R., et al. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000002275 · Cited by 10
“We assessed the risk of bias of each study using the Quality Assessment of Diagnostic Accuracy Studies-2 tool [16] (Fig.”
Clinical and Pathological Staging Discrepancies in Laryngeal Cancer: A Systematic Review
Pecorari, G., Lorenzi, A., Caria, M., Motatto, G. M., & Riva, G. (2025) · Cancers · doi:10.3390/cancers17030455 · Cited by 10
“The risk of bias in all included studies was systematically evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool, which is specifically designed to assess the quality of primary diagnostic accuracy studies [9].”
Oliveira, S. B., Machado, M., Sousa, D., Pereira, S. S., & Pignatelli, D. (2025) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-025-09945-w · Cited by 10
“The methodological quality of included studies was assessed by three reviewers (SBO, MQM and SSP) using the revised Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2), which includes four key domains: “patient selection”, “index test”, “reference standard” and “flow and timing” [42].”
Wang, T., Wang, C.-K., Hong, J., Chao, H., Chen, Y., & Wu, Y. (2025) · Cancers · doi:10.3390/cancers17040621 · Cited by 13
May, C., Ford, N. P., Welsh, G. I., & Saleem, M. A. (2025) · PLoS ONE · doi:10.1371/journal.pone.0312232 · Cited by 11
“The specific methodology is covered in detail here [21].”
Yan, G., Wang, Y., & Chen, L. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.02.044 · Cited by 11
Wang, S., Yang, H., Liao, H., He, P., Zhang, X., Liu, H., Qu, B., & Yang, H. (2025) · Global Spine Journal · doi:10.1177/21925682251327381 · Cited by 10
Lv, M., Xu, H., Yang, X., Li, S., Mao, Z., Zhang, X., & Yang, K. (2025) · Cancer Imaging · doi:10.1186/s40644-025-00861-5 · Cited by 14
“Risk of bias of included studies was assessed using the Quality Assessment Of Diagnostic Accuracy Studies-C (QUADAS-C) [37]and Assessment Of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [38].”
Mohammadi, I., Farahani, S., Karimi, A., Jahanian, S., Firouzabadi, S. R., Alinejadfard, M., Fatemi, A., Hajikarimloo, B., & Akhlaghpasand, M. (2025) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2025.1551959 · Cited by 11
Xie, D., Xu, H., Wang, F., Wen, W., & Dong, B. (2025) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2025.104038 · Cited by 10
Sunscreen and 25-Hydroxyvitamin D Levels: Friends or Foes? A Systematic Review and Meta-Analysis
Gatta, E., & Cappelli, C. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.03.014 · Cited by 10
Quality measures of two-stage newborn hearing screening: systematic review and meta-analysis
Manz, K. M., Nennstiel, U., Marzi, C., Mansmann, U., & Brockow, I. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1566478 · Cited by 10
Heart rate variability as a marker of multiple organ dysfunction syndromes: a systematic review
Wojtanowski, A., Hureau, M., Jeanne, M., Bureau, C., Recher, M., & Jonckheere, J. D. (2025) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-025-01296-w · Cited by 10
“With regards to the risk of bias in evaluations of MODS (as rated on the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) scale) [13], most of the reviewed studies included patients who had several clinical conditions, were sedated or were ventilated (Table 3).”
Agrotis, G., Pooch, E., Marsitopoulos, K., Vlychou, M., Benndorf, M., Beets‐Tan, R. G. H., & Schoots, I. G. (2025) · European Radiology · doi:10.1007/s00330-025-11618-w · Cited by 12
“The methodological quality, potential introduction of bias, and applicability of the included studies in the meta-analysis were evaluated using the revised tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [3].”
Wang, Y., Wang, Q., Yu, W., Cai, J., Shan, L., Wang, X., Fang, M., & Lu, X. (2025) · Journal of Oral Rehabilitation · doi:10.1111/joor.13992 · Cited by 10
“A total of 19 studies [11–13, 29–32, 36–38, 40, 41, 44, 46–48, 53–55] reported the interrater reliability (shown in Table S9).”
InfluentialThermography in Stroke—A Systematic Review
Podlasek, A., Petrov, I. S., Stankov, Z. I., Snyder, K. V., Alvarez, C. A., Musiałek, P., & Grunwald, I. Q. (2025) · Medicina · doi:10.3390/medicina61050854 · Cited by 10
Geysels, A., Garofalo, G., Timmerman, S., Barreñada, L., Moor, B. D., Timmerman, D., Froyman, W., & CALSTER, B. V. (2025) · Gynecologic and Obstetric Investigation · doi:10.1159/000545850 · Cited by 12
“Following QUADAS-2 guidelines, any study rated as “ high risk ” in one or more domains was at overall “ risk of bias ” [23].”
Alampritis, G., Thoukididou, S. N., Ramos, M., Georgiou, P., Kalofonou, M., & Simillis, C. (2025) · International Journal of Colorectal Disease · doi:10.1007/s00384-025-04904-y · Cited by 11
“Review Manager 5 software Version 5.4 was used for managing the QUADAS-2 data and creating figures [36].”
InfluentialWei, W., Yang, B., Zhu, Y., Liu, C., Huang, Y., Yang, L., Li, J. H., Ren, J., Ma, L., Zhang, L., et al. (2025) · Clinical and Experimental Medicine · doi:10.1007/s10238-025-01746-4 · Cited by 12
“The quality assessment and risk of bias for the 29 included studies were independently elevated by two authors (WW and YBY) following the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) [10].”
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.