Routine single particle CryoEM sample and grid characterization by tomography
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Single particle cryo-electron microscopy (cryoEM) is often performed under the assumption that particles are not adsorbed to the air-water interfaces and in thin, vitreous ice. In this study, we performed fiducial-less tomography on over 50 different cryoEM grid/sample preparations to determine the particle distribution within the ice and the overall geometry of the ice in grid holes. Surprisingly, by studying particles in holes in 3D from over 1000 tomograms, we have determined that the vast majority of particles (approximately 90%) are adsorbed to an air-water interface. The implications of this observation are wide-ranging, with potential ramifications regarding protein denaturation, conformational change, and preferred orientation. We also show that fiducial-less cryo-electron tomography on single particle grids may be used to determine ice thickness, optimal single particle collection areas and strategies, particle heterogeneity, and de novo models for template picking and single particle alignment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UCSF Chimera—A visualization system for exploratory research and analysis
Pettersen, E. F., Goddard, T. D., Huang, C. C., Couch, G. S., Greenblatt, D. M., Meng, E. C., & Ferrin, T. E. (2004) · Journal of Computational Chemistry · doi:10.1002/jcc.20084 · Cited by 45,828
cryoSPARC: algorithms for rapid unsupervised cryo-EM structure determination
Punjani, A., Rubinstein, J. L., Fleet, D. J., & Brubaker, M. A. (2017) · Nature Methods · doi:10.1038/nmeth.4169 · Cited by 11,626
MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy
Zheng, S. Q., Palovcak, E., Armache, J.-P., Verba, K. A., Cheng, Y., & Agard, D. A. (2017) · Nature Methods · doi:10.1038/nmeth.4193 · Cited by 7,777
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
Gctf: Real-time CTF determination and correction
Zhang, K. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.11.003 · Cited by 3,537
EMAN: Semiautomated Software for High-Resolution Single-Particle Reconstructions
Ludtke, S. J., Baldwin, P. R., & Chiu, W. (1999) · Journal of Structural Biology · doi:10.1006/jsbi.1999.4174 · Cited by 2,391
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389
THE CONSTITUTION AND FUNDAMENTAL PROPERTIES OF SOLIDS AND LIQUIDS. II. LIQUIDS.1
Langmuir, I. (1917) · Journal of the American Chemical Society · doi:10.1021/ja02254a006 · Cited by 2,350
Automated molecular microscopy: The new Leginon system
Suloway, C., Pulokas, J., Fellmann, D., Cheng, A., Guerra, F., Quispe, J., Stagg, S., Potter, C. S., & Carragher, B. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.03.010 · Cited by 1,764
Self-citation
Cited by
Real-time cryo-electron microscopy data preprocessing with Warp
Tegunov, D., & Cramer, P. (2019) · Nature Methods · doi:10.1038/s41592-019-0580-y · Cited by 1,332
Cryo-EM in drug discovery: achievements, limitations and prospects
Renaud, J.-P., Chari, A., Ciferri, C., Liu, W.-T., Rémigy, H.-W., Stark, H., & Wiesmann, C. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.77 · Cited by 461
Structure of a Signaling Cannabinoid Receptor 1-G Protein Complex
Krishna Kumar, K., Shalev-Benami, M., Robertson, M. J., Hu, H., Banister, S. D., Hollingsworth, S. A., Latorraca, N. R., Kato, H. E., Hilger, D., Maeda, S., et al. (2019) · Cell · doi:10.1016/j.cell.2018.11.040 · Cited by 419
Challenges and opportunities in cryo-EM single-particle analysis
Lyumkis, D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev118.005602 · Cited by 356
Structure of the M2 muscarinic receptor–β-arrestin complex in a lipid nanodisc
Staus, D. P., Hu, H., Robertson, M. J., Kleinhenz, A. L. W., Wingler, L. M., Capel, W. D., Latorraca, N. R., Lefkowitz, R. J., & Skiniotis, G. (2020) · Nature · doi:10.1038/s41586-020-1954-0 · Cited by 351
Isotropic reconstruction for electron tomography with deep learning
Liu, Y.-T., Zhang, H., Wang, H., Tao, C.-L., Bi, G.-Q., & Zhou, Z. H. (2022) · Nature Communications · doi:10.1038/s41467-022-33957-8 · Cited by 349
Protein denaturation at the air-water interface and how to prevent it
D'Imprima, E., Floris, D., Joppe, M., Sánchez, R., Grininger, M., & Kühlbrandt, W. (2019) · eLife · doi:10.7554/elife.42747 · Cited by 297
FACT caught in the act of manipulating the nucleosome
Liu, Y., Zhou, K., Zhang, N., Wei, H., Tan, Y. Z., Zhang, Z., Carragher, B., Potter, C. S., D’Arcy, S., & Luger, K. (2020) · Nature · doi:10.1038/s41586-019-1820-0 · Cited by 227
Self-citationRoutine determination of ice thickness for cryo-EM grids
Rice, W. J., Cheng, A., Noble, A. J., Eng, E. T., Kim, L. Y., Carragher, B., & Potter, C. S. (2018) · Journal of Structural Biology · doi:10.1016/j.jsb.2018.06.007 · Cited by 161
Self-citationVisualization of clustered protocadherin neuronal self-recognition complexes
Brasch, J., Goodman, K. M., Noble, A. J., Rapp, M., Mannepalli, S., Bahna, F., Dandey, V. P., Bepler, T., Berger, B., Maniatis, T., et al. (2019) · Nature · doi:10.1038/s41586-019-1089-3 · Cited by 99
Self-citationMicrotubule architecture in vitro and in cells revealed by cryo-electron tomography
Atherton, J., Stouffer, M., Francis, F., & Moores, C. A. (2018) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798318001948 · Cited by 85
Castells-Graells, R., Meador, K., Arbing, M. A., Sawaya, M. R., Gee, M., Cascio, D., Gleave, E., Debreczeni, J. É., Breed, J., Leopold, K., et al. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2305494120 · Cited by 48
Zhang, H., Zheng, D., Wu, Q., Yan, N., Peng, H., Hu, Q., Peng, Y., Yan, Z., Shi, Z., Bao, C., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-59797-w · Cited by 12
Factors affecting macromolecule orientations in thin films formed in cryo-EM
Yadav, S., & Vinothkumar, K. R. (2024) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798324005229 · Cited by 7
Shatarupa, A., Brown, D., Olinares, P. D. B., Chase, J., Isiorho, E., Chait, B. T., & Jeruzalmi, D. (2025) · Nucleic Acids Research · doi:10.1093/nar/gkaf1139 · Cited by 3
Self-citation
Metadata
- Authors
- Noble, A. J., Dandey, V. P., Wei, H., Brasch, J., Chase, J., Acharya, P., Tan, Y. Z., Zhang, Z., Kim, L. Y., Scapin, G., Rapp, M., Eng, E. T., Rice, W. J., Cheng, A., Negro, C. J., Shapiro, L., Kwong, P. D., Jeruzalmi, D., des Georges, A., Potter, C. S., & Carragher, B.
- Venue
- eLife
- Publisher
- eLife Sciences Publications, Ltd
- Published
- 2018-05-29
- Volume
- 7
- ISSN
- 2050-084X (ISSN-L)
- OpenAlex
- W2949882099
- Cited by
- 296
- References
- 65
- FWCI
- 15.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.