The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Routine single particle CryoEM sample and grid characterization by tomography
Open accessAbstract
Single particle cryo-electron microscopy (cryoEM) is often performed under the assumption that particles are not adsorbed to the air-water interfaces and in thin, vitreous ice. In this study, we performed fiducial-less tomography on over 50 different cryoEM grid/sample preparations to determine the particle distribution within the ice and the overall geometry of the ice in grid holes. Surprisingly, by studying particles in holes in 3D from over 1000 tomograms, we have determined that the vast majority of particles (approximately 90%) are adsorbed to an air-water interface. The implications of this observation are wide-ranging, with potential ramifications regarding protein denaturation, conformational change, and preferred orientation. We also show that fiducial-less cryo-electron tomography on single particle grids may be used to determine ice thickness, optimal single particle collection areas and strategies, particle heterogeneity, and de novo models for template picking and single particle alignment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UCSF Chimera—A visualization system for exploratory research and analysis
Pettersen, E. F., Goddard, T. D., Huang, C. C., Couch, G. S., Greenblatt, D. M., Meng, E. C., & Ferrin, T. E. (2004) · Journal of Computational Chemistry · doi:10.1002/jcc.20084 · Cited by 45,828
cryoSPARC: algorithms for rapid unsupervised cryo-EM structure determination
Punjani, A., Rubinstein, J. L., Fleet, D. J., & Brubaker, M. A. (2017) · Nature Methods · doi:10.1038/nmeth.4169 · Cited by 11,626
MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy
Zheng, S. Q., Palovcak, E., Armache, J.-P., Verba, K. A., Cheng, Y., & Agard, D. A. (2017) · Nature Methods · doi:10.1038/nmeth.4193 · Cited by 7,777
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
Gctf: Real-time CTF determination and correction
Zhang, K. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.11.003 · Cited by 3,537
EMAN: Semiautomated Software for High-Resolution Single-Particle Reconstructions
Ludtke, S. J., Baldwin, P. R., & Chiu, W. (1999) · Journal of Structural Biology · doi:10.1006/jsbi.1999.4174 · Cited by 2,391
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389
THE CONSTITUTION AND FUNDAMENTAL PROPERTIES OF SOLIDS AND LIQUIDS. II. LIQUIDS.1
Langmuir, I. (1917) · Journal of the American Chemical Society · doi:10.1021/ja02254a006 · Cited by 2,350
Automated molecular microscopy: The new Leginon system
Suloway, C., Pulokas, J., Fellmann, D., Cheng, A., Guerra, F., Quispe, J., Stagg, S., Potter, C. S., & Carragher, B. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.03.010 · Cited by 1,764
Self-citationUnderstanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
Cryo-electron microscopy of viruses
Adrian, M., Dubochet, J., Lepault, J., & McDowall, A. W. (1984) · Nature · doi:10.1038/308032a0 · Cited by 1,342
Spontaneous assembly of a self-complementary oligopeptide to form a stable macroscopic membrane.
Zhang, S., Holmes, T., Lockshin, C., & Rich, A. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.8.3334 · Cited by 1,304
(2017) · Effective Library and Information Centre Management · doi:10.4324/9781315256894-38 · Cited by 1,119
Addressing preferred specimen orientation in single-particle cryo-EM through tilting
Tan, Y. Z., Baldwin, P. R., Davis, J. H., Williamson, J. R., Potter, C. S., Carragher, B., & Lyumkis, D. (2017) · Nature Methods · doi:10.1038/nmeth.4347 · Cited by 903
Self-citationcisTEM, user-friendly software for single-particle image processing
Grant, T., Rohou, A., & Grigorieff, N. (2018) · eLife · doi:10.7554/elife.35383 · Cited by 865
Graham, D. E., & Phillips, M. C. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90048-1 · Cited by 843
Appion: An integrated, database-driven pipeline to facilitate EM image processing
Lander, G. C., Stagg, S. M., Voss, N. R., Cheng, A., Fellmann, D., Pulokas, J., Yoshioka, C., Irving, C., Mulder, A., Lau, P.-W., et al. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.01.002 · Cited by 835
Self-citationGrant, T., & Grigorieff, N. (2015) · eLife · doi:10.7554/elife.06980 · Cited by 826
Mastronarde, D. N. (2003) · Microscopy and Microanalysis · doi:10.1017/s1431927603445911 · Cited by 540
Proteins and emulsifiers at liquid interfaces
Wilde, P., Mackie, A., Husband, F., Gunning, P., & Morris, V. (2004) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2003.10.011 · Cited by 517
Castaño-Díez, D., Kudryashev, M., Arheit, M., & Stahlberg, H. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.017 · Cited by 509
Electron microscopy of frozen water and aqueous solutions
Dubochet, J., Lepault, J., Freeman, R., Berriman, J. A., & Homo, J. (1982) · Journal of Microscopy · doi:10.1111/j.1365-2818.1982.tb04625.x · Cited by 486
Electron Diffraction of Frozen, Hydrated Protein Crystals
Taylor, K. A., & Glaeser, R. M. (1974) · Science · doi:10.1126/science.186.4168.1036 · Cited by 440
Beam-induced motion of vitrified specimen on holey carbon film
Brilot, A. F., Chen, J. Z., Cheng, A., Pan, J., Harrison, S. C., Potter, C. S., Carragher, B., Henderson, R., & Grigorieff, N. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.02.003 · Cited by 411
Self-citationDisentangling conformational states of macromolecules in 3D-EM through likelihood optimization
Scheres, S. H. W., Gao, H., Valle, M., Herman, G. T., Eggermont, P. P. B., Frank, J., & Carazo, J.-M. (2007) · Nature Methods · doi:10.1038/nmeth992 · Cited by 407
Ultrastable gold substrates for electron cryomicroscopy
Russo, C. J., & Passmore, L. A. (2014) · Science · doi:10.1126/science.1259530 · Cited by 400
Kedersha, N. L., & Rome, L. H. (1986) · The Journal of cell biology · doi:10.1083/jcb.103.3.699 · Cited by 368
Orogenic Displacement of Protein from the Air/Water Interface by Competitive Adsorption
Mackie, A. R., Gunning, A. P., Wilde, P. J., & Morris, V. J. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5941 · Cited by 353
Image processing for electron microscopy single-particle analysis using XMIPP
Scheres, S. H. W., Núñez-Ramírez, R., Sorzano, C. O. S., Carazo, J. M., & Marabini, R. (2008) · Nature Protocols · doi:10.1038/nprot.2008.62 · Cited by 325
Fast tomographic reconstruction on multicore computers
Agulleiro, J. I., & Fernandez, J. J. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btq692 · Cited by 260
Reducing effects of particle adsorption to the air–water interface in cryo-EM
Noble, A. J., Wei, H., Dandey, V. P., Zhang, Z., Tan, Y. Z., Potter, C. S., & Carragher, B. (2018) · Nature Methods · doi:10.1038/s41592-018-0139-3 · Cited by 212
Self-citationMeasuring the effects of particle orientation to improve the efficiency of electron cryomicroscopy
Naydenova, K., & Russo, C. J. (2017) · Nature Communications · doi:10.1038/s41467-017-00782-3 · Cited by 206
Tomo3D 2.0 – Exploitation of Advanced Vector eXtensions (AVX) for 3D reconstruction
Agulleiro, J.-I., & Fernandez, J.-J. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2014.11.009 · Cited by 205
Winkler, H., & Taylor, K. A. (2006) · Ultramicroscopy · doi:10.1016/j.ultramic.2005.07.007 · Cited by 201
Fully automated, sequential tilt-series acquisition with Leginon
Suloway, C., Shi, J., Cheng, A., Pulokas, J., Carragher, B., Potter, C. S., Zheng, S. Q., Agard, D. A., & Jensen, G. J. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.03.019 · Cited by 181
Self-citationTaylor, K. A., & Glaeser, R. M. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.06.004 · Cited by 163
Opinion: hazards faced by macromolecules when confined to thin aqueous films
Glaeser, R. M., & Han, B.-G. (2016) · Biophysics Reports · doi:10.1007/s41048-016-0026-3 · Cited by 161
Billsten, P., Wahlgren, M., Arnebrant, T., McGuire, J., & Elwing, H. (1995) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1995.1431 · Cited by 159
Spotiton: A prototype for an integrated inkjet dispense and vitrification system for cryo-TEM
Jain, T., Sheehan, P., Crum, J. K., Carragher, B. O., & Potter, C. S. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.04.020 · Cited by 153
Self-citationDamodaran, S., & Song, K. B. (1988) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/0167-4838(88)90080-5 · Cited by 146
Castaño‐Díez, D., Kudryashev, M., & Stahlberg, H. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.06.005 · Cited by 145
Time-resolved cryo-electron microscopy: Recent progress
Frank, J. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2017.06.005 · Cited by 143
A new method for vitrifying samples for cryoEM
Razinkov, I., Dandey, V. P., Wei, H. A., Zhang, Z., Melnekoff, D. T., Rice, W. J., Wigge, C., Potter, C. S., & Carragher, B. O. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.06.001 · Cited by 136
Self-citationKinetics of protein unfolding at interfaces
Yano, Y. F. (2012) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/24/50/503101 · Cited by 130
Cryo-EM structure of human DNA-PK holoenzyme
Yin, X., Liu, M., Tian, Y., Wang, J., & Xu, Y. (2017) · Cell Research · doi:10.1038/cr.2017.110 · Cited by 126
Feng, X., Fu, Z., Kaledhonkar, S., Jia, Y., Shah, B., Jin, A. T., Liu, Z., Sun, M., Chen, B., Grassucci, R. A., et al. (2017) · Structure · doi:10.1016/j.str.2017.02.005 · Cited by 123
Arnold, S. A., Albiez, S., Bieri, A., Syntychaki, A., Adaixo, R., McLeod, R. A., Goldie, K. N., Stahlberg, H., & Braun, T. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.11.002 · Cited by 110
Emerging techniques: Cryo-electron microscopy of vitrified biological specimens
Dubochet, J., Adrian, M., Lepault, J., & McDowall, A. W. (1985) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(85)90150-1 · Cited by 107
The adsorbed conformation of globular proteins at the air/water interface
Lad, M. D., Birembaut, F., Matthew, J. M., Frazier, R. A., & Green, R. J. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b515934b · Cited by 106
Design of a molecular support for cryo-EM structure determination
Martin, T. G., Bharat, T. A. M., Joerger, A. C., Bai, X., Praetorius, F., Fersht, A. R., Dietz, H., & Scheres, S. H. W. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612720113 · Cited by 102
SIMPLE: Software for ab initio reconstruction of heterogeneous single-particles
Elmlund, D., & Elmlund, H. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.07.010 · Cited by 98
Factors that Influence the Formation and Stability of Thin, Cryo-EM Specimens
Glaeser, R. M., Han, B.-G., Csencsits, R., Killilea, A. N., Pulk, A., & Cate, J. H. D. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.07.050 · Cited by 87
Martin, A. H., Meinders, M. B. J., Bos, M. A., Stuart, M. A. C., & van Vliet, T. (2003) · Langmuir · doi:10.1021/la0208629 · Cited by 83
Morris, V. J., & Gunning, A. P. (2008) · Soft Matter · doi:10.1039/b718904d · Cited by 81
Flexible Architecture of IP3R1 by Cryo-EM
Ludtke, S. J., Tran, T. P., Ngo, Q. T., Moiseenkova‐Bell, V. Y., Chiu, W., & Serysheva, I. I. (2011) · Structure · doi:10.1016/j.str.2011.05.003 · Cited by 78
Automated batch fiducial-less tilt-series alignment in Appion using Protomo
Noble, A. J., & Stagg, S. M. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.10.003 · Cited by 66
Self-citationThe structure of latherin, a surfactant allergen protein from horse sweat and saliva
Vance, S., McDonald, R. E., Cooper, A., Smith, B. O., & Kennedy, M. W. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0453 · Cited by 61
An Improved Holey Carbon Film for Cryo-Electron Microscopy
Quispe, J. D., Damiano, J., Mick, S., Nackashi, D. P., Fellmann, D., Ajero, T. G., Carragher, B. O., & Potter, C. S. (2007) · Microscopy and Microanalysis · doi:10.1017/s1431927607070791 · Cited by 58
Self-citationPhospholipid, Nature's own slide and cover slip for cryo‐electron microscopy
Frederik, P. M., Stuart, M. C. A., Bomans, P. H. H., & Busing, W. M. (1989) · Journal of Microscopy · doi:10.1111/j.1365-2818.1989.tb01469.x · Cited by 57
Getting the feel of food structure with atomic force microscopy
Gunning, A. P., & Morris, V. J. (2017) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2017.05.017 · Cited by 47
Meinders, M. B. J., van den Bosch, G. G. M., & de Jongh, H. H. J. (2001) · European Biophysics Journal · doi:10.1007/s002490000124 · Cited by 43
Floch‐Fouéré, C. L., Beaufils, S., Lechevalier-Datin, V., Nau, F., Pézolet, M., Renault, A., & Pezennec, S. (2009) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2009.10.006 · Cited by 39
Single Particle Analysis at High Resolution
Cong, Y., & Ludtke, S. J. (2010) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(10)82009-9 · Cited by 37
Vos, M. R. J., Bomans, P. H. H., Frederik, P. M., & Sommerdijk, N. A. J. M. (2008) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.03.014 · Cited by 23
Cited by
Real-time cryo-electron microscopy data preprocessing with Warp
Tegunov, D., & Cramer, P. (2019) · Nature Methods · doi:10.1038/s41592-019-0580-y · Cited by 1,332
Cryo-EM in drug discovery: achievements, limitations and prospects
Renaud, J.-P., Chari, A., Ciferri, C., Liu, W.-T., Rémigy, H.-W., Stark, H., & Wiesmann, C. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.77 · Cited by 461
Structure of a Signaling Cannabinoid Receptor 1-G Protein Complex
Krishna Kumar, K., Shalev-Benami, M., Robertson, M. J., Hu, H., Banister, S. D., Hollingsworth, S. A., Latorraca, N. R., Kato, H. E., Hilger, D., Maeda, S., et al. (2019) · Cell · doi:10.1016/j.cell.2018.11.040 · Cited by 419
Challenges and opportunities in cryo-EM single-particle analysis
Lyumkis, D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev118.005602 · Cited by 356
Structure of the M2 muscarinic receptor–β-arrestin complex in a lipid nanodisc
Staus, D. P., Hu, H., Robertson, M. J., Kleinhenz, A. L. W., Wingler, L. M., Capel, W. D., Latorraca, N. R., Lefkowitz, R. J., & Skiniotis, G. (2020) · Nature · doi:10.1038/s41586-020-1954-0 · Cited by 351
Metadata
- Authors
- Noble, A. J., Dandey, V. P., Wei, H., Brasch, J., Chase, J., Acharya, P., Tan, Y. Z., Zhang, Z., Kim, L. Y., Scapin, G., Rapp, M., Eng, E. T., Rice, W. J., Cheng, A., Negro, C. J., Shapiro, L., Kwong, P. D., Jeruzalmi, D., des Georges, A., Potter, C. S., & Carragher, B.
- Venue
- eLife
- Publisher
- eLife Sciences Publications, Ltd
- Published
- 2018-05-29
- Volume
- 7
- ISSN
- 2050-084X (ISSN-L)
- OpenAlex
- W2949882099
- Cited by
- 296
- References
- 65
- FWCI
- 15.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.