Magnetocardiography and magnetoencephalography measurements at room temperature using tunnel magneto-resistance sensors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Magnetocardiography (MCG) and magnetoencephalography (MEG) signals were detected at room temperature using tunnel magneto-resistance (TMR) sensors. TMR sensors developed with low-noise amplifier circuits detected the MCG R wave without averaging, and the QRS complex was clearly observed with averaging at a high signal-to-noise ratio. Spatial mapping of the MCG was also achieved. Averaging of MEG signals triggered by electroencephalography (EEG) clearly observed the phase inversion of the alpha rhythm with a correlation coefficient as high as 0.7 between EEG and MEG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Cited by
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“[18]) achieve a limit of detection of 14 pT/ √ Hz.”
BackgroundSub-pT magnetic field detection by tunnel magneto-resistive sensors
Oogane, M., Fujiwara, K., Kanno, A., Nakano, T., Wagatsuma, H., Arimoto, T., Mizukami, S., Kumagai, S., Matsuzaki, H., Nakasato, N., et al. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac3809 · Cited by 110
Self-citationMillimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Kurashima, K., Kataoka, M., Nakano, T., Fujiwara, K., Kato, S., Nakamura, T., Yuzawa, M., Masuda, M., Ichimura, K., Okatake, S., et al. (2023) · Sensors · doi:10.3390/s23020646 · Cited by 56
“5Si15B10 with excellent flatness and a soft magnetic property [23,25,26], which has been reported to lead the small anisotropy field and high sensitivity.”
BackgroundSelf-citationTunnel-magnetoresistance sensors with sub-pT detectivity for detecting bio-magnetic fields
Nakano, T., Fujiwara, K., & Oogane, M. (2025) · Applied Physics Letters · doi:10.1063/5.0263879 · Cited by 22
Self-citation
Metadata
- Authors
- Fujiwara, K., Oogane, M., Kanno, A., Imada, M., Jono, J., Terauchi, T., Okuno, T., Aritomi, Y., Morikawa, M., Tsuchida, M., Nakasato, N., & Ando, Y.
- Venue
- Applied Physics Express
- Publisher
- IOP Publishing
- Published
- 2018-01-18
- Volume
- 11
- Issue
- 2
- Pages
- 023001
- ISSN
- 1882-0778 (ISSN-L)
- 1882-0786
- OpenAlex
- W2792538345
- Cited by
- 133
- References
- 1
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetocardiography and magnetoencephalography measurements at room temperature using tunnel magneto-resistance sensors. https://app.cochat.ai/papers/10.7567/apex.11.023001
- The paper
- Fujiwara, K., Oogane, M., Kanno, A., Imada, M., Jono, J., Terauchi, T., Okuno, T., Aritomi, Y., Morikawa, M., Tsuchida, M., Nakasato, N., & Ando, Y. (2018). Magnetocardiography and magnetoencephalography measurements at room temperature using tunnel magneto-resistance sensors. Applied Physics Express. https://doi.org/10.7567/apex.11.023001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.