The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Sub-pT magnetic field detection by tunnel magneto-resistive sensors
Open accessAbstract
We developed tunnel magneto-resistive (TMR) sensors based on magnetic tunnel junctions (MTJs) that are able to detect a weak, sub-pT, magnetic field at a low frequency. Small detectivities of 0.94 pT/Hz 1/2 at 1 Hz and 0.05 pT/Hz 1/2 at 1 kHz were achieved by lowering the resistance of MTJs and enhancement of the signal using a thick CoFeSiB layer and magnetic flux concentrators. We demonstrated real-time measurement of magnetocardiography (MCG) and nuclear magnetic resonance (NMR) of protons using developed sensors. This result shows that both MCG and NMR can be measured by the same measurement system with ultra-sensitive TMR sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In parallel, advances in tunnel magnetoresistance (TMR) sensors demonstrate rapid progress towards compact, room-temperature biomagnetic detection. Studies report sub-picotesla sensitivity in miniaturized silicon-compatible architectures that enable real-time MCG and neuronal spike detection without cryogenic cooling.”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [50]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These developments position TMR sensors as emerging practical alternatives to cryogenic SQUID platforms, with potential applications in wearable systems and brain–machine interfaces [48,49,50].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giant room-temperature magnetoresistance in single-crystal Fe/MgO/Fe magnetic tunnel junctions
Yuasa, S., Nagahama, T., Fukushima, A., Suzuki, Y., & Ando, K. (2004) · Nature Materials · doi:10.1038/nmat1257 · Cited by 3,331
Giant tunnelling magnetoresistance at room temperature with MgO (100) tunnel barriers
Parkin, S. S. P., Kaiser, C., Panchula, A., Rice, P. M., Hughes, B., Samant, M., & Yang, S.-H. (2004) · Nature Materials · doi:10.1038/nmat1256 · Cited by 3,320
Spin-dependent tunneling conductance ofFe|MgO|Fesandwiches
Butler, W. H., Zhang, X.-G., Schulthess, T. C., & MacLaren, J. M. (2001) · Physical Review B · doi:10.1103/physrevb.63.054416 · Cited by 2,102
Ikeda, S., Hayakawa, J., Ashizawa, Y., Lee, Y. M., Miura, K., Hasegawa, H., Tsunoda, M., Matsukura, F., & Ohno, H. (2008) · Applied Physics Letters · doi:10.1063/1.2976435 · Cited by 1,596
Theory of tunneling magnetoresistance of an epitaxial Fe/MgO/Fe(001) junction
Mathon, J., & Umerski, A. (2001) · Physical Review B · doi:10.1103/physrevb.63.220403 · Cited by 1,302
The Nuclear Induction Experiment
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.70.474 · Cited by 1,192
230% room-temperature magnetoresistance in CoFeB∕MgO∕CoFeB magnetic tunnel junctions
Djayaprawira, D. D., Tsunekawa, K., Nagai, M., Maehara, H., Yamagata, S., Watanabe, N., Yuasa, S., Suzuki, Y., & Ando, K. (2005) · Applied Physics Letters · doi:10.1063/1.1871344 · Cited by 967
Yuasa, S., Fukushima, A., Nagahama, T., Ando, K., & Suzuki, Y. (2004) · Japanese Journal of Applied Physics · doi:10.1143/jjap.43.l588 · Cited by 298
Magnetoresistive Random Access Memory: Present and Future
Ikegawa, S., Mancoff, F. B., Janesky, J., & Aggarwal, S. (2020) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2020.2965403 · Cited by 270
Yoda, H., Kishi, T., Nagase, T., Yoshikawa, M., Nishiyama, K., Kitagawa, E., Daibou, T., Amano, M., Shimomura, N., Takahashi, S., et al. (2010) · Current Applied Physics · doi:10.1016/j.cap.2009.12.021 · Cited by 179
Self-citation
Research works printed but not linked: 1
- Uchiyama, 2019, IEEE Trans. Magn., 55
Cited by
Scalp attached tangential magnetoencephalography using tunnel magneto-resistive sensors
Kanno, A., Nakasato, N., Oogane, M., Fujiwara, K., Nakano, T., Arimoto, T., Matsuzaki, H., & Ando, Y. (2022) · Scientific Reports · doi:10.1038/s41598-022-10155-6 · Cited by 70
Self-citationSpintronic devices for biomedical applications
Mostufa, S., Liang, S. A., Chugh, V. K., Wang, J., & Wu, K. (2024) · npj Spintronics · doi:10.1038/s44306-024-00031-6 · Cited by 68
Kurashima, K., Kataoka, M., Nakano, T., Fujiwara, K., Kato, S., Nakamura, T., Yuzawa, M., Masuda, M., Ichimura, K., Okatake, S., et al. (2023) · Sensors · doi:10.3390/s23020646 · Cited by 56
“5Si15B10 with excellent flatness and a soft magnetic property [23,25,26], which has been reported to lead the small anisotropy field and high sensitivity.”
BackgroundSelf-citationA review on soft pneumatic actuators with integrated or embedded soft sensors
Gariya, N., Kumar, S., Shaikh, A., Prasad, B., & Nautiyal, H. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115364 · Cited by 55
Enhanced performance and functionality in spintronic sensors
Leitão, D. C., van Riel, F. J. F., Rasly, M., Araujo, P. D. R., Salvador, M., Paz, E., & Koopmans, B. (2024) · npj Spintronics · doi:10.1038/s44306-024-00058-9 · Cited by 41
Metadata
- Authors
- Oogane, M., Fujiwara, K., Kanno, A., Nakano, T., Wagatsuma, H., Arimoto, T., Mizukami, S., Kumagai, S., Matsuzaki, H., Nakasato, N., & Ando, Y.
- Affiliations
- Tohoku University (JP)
- Konica Minolta (Japan) (JP)
- Corresponding author
- Oogane, Mikihiko
- ORCID
- Venue
- Applied Physics Express
- Publisher
- IOP Publishing
- Published
- 2021-11-22
- Volume
- 14
- Issue
- 12
- Pages
- 123002
- ISSN
- 1882-0778 (ISSN-L)
- 1882-0786
- OpenAlex
- W3213224992
- Cited by
- 110
- References
- 34
- Citations by year
- 2026: 28 · 2025: 24 · 2024: 23 · 2023: 26 · 2022: 8 · 2021: 1
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Applied Physics Express (publishedVersion, cc-by)
- Funders
- Japan Science and Technology Agency
- Center for Spintronics Research Network, Tohoku University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Magnetic properties of thin films
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetic tunnel junctions, detectivity, magnetic flux concentrators, magnetocardiography, 1H NMR
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sub-pT magnetic field detection by tunnel magneto-resistive sensors. https://app.cochat.ai/papers/10.35848/1882-0786/ac3809
- The paper
- Oogane, M., Fujiwara, K., Kanno, A., Nakano, T., Wagatsuma, H., Arimoto, T., Mizukami, S., Kumagai, S., Matsuzaki, H., Nakasato, N., & Ando, Y. (2021). Sub-pT magnetic field detection by tunnel magneto-resistive sensors. Applied Physics Express. https://doi.org/10.35848/1882-0786/ac3809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.