We performed spectroscopic observations of the 698-nm clock transition in 87 Sr confined in an optical lattice using a laser linewidth transfer technique. A narrow-linewidth laser interrogating the clock transition was prepared by transferring the linewidth of a master laser (1064 nm) to that of a slave laser (698 nm) with a high-speed controllable fiber-based frequency comb. The Fourier-limited spectrum was then observed for an 80-ms interrogating pulse. We determined that the absolute frequency of the 5s 2 1 S 0 –5s5p 3 P 0 clock transition in 87 Sr is 429 228 004 229 872.0 (1.6) Hz referenced to the SI second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Frequency comparison of optical lattice clocks beyond the Dick limit
Takamoto, M., Takano, T., & Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.34 · Cited by 154
The87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Metadata
- Authors
- Akamatsu, D., Inaba, H., Hosaka, K., Yasuda, M., Onae, A., Suzuyama, T., Amemiya, M., & Hong, F.-L.
- Venue
- Applied Physics Express
- Publisher
- IOP Publishing
- Published
- 2013-12-18
- Volume
- 7
- Issue
- 1
- Pages
- 012401
- ISSN
- 1882-0778 (ISSN-L)
- 1882-0786
- OpenAlex
- W2032078432
- Cited by
- 49
- References
- 6
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.