The87Sr optical frequency standard at PTB
Open accessAbstract
With 87 Sr atoms confined in a one-dimensional optical lattice, the frequency of the optical clock transition 5s 2 1 S 0 –5s5p 3 P 0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a femtosecond-frequency comb against one of Physikalisch-Technische Bundesanstalt (PTB's) H-masers whose frequency was measured simultaneously by the PTB Cs-fountain clock CSF1. The Sr optical frequency standard contributes with a fractional uncertainty of 1.5 × 10 −16 to the total uncertainty. The agreement of the measured transition frequency with previous measurements at other institutes supports the status of this transition as the secondary representation of the second with the currently smallest uncertainty.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
With a lifetime of the excited clock state of about 120 s and the light shift coefficient of about -13 Hz cm^2 W^-1, the clock laser induced light shift is estimated to be negligible, of few 10^-19.
“With a lifetime of the excited clock state of about 120 s [44-46] and the light shift coefficient of about -13 Hzcm 2 W -1 [47], we estimate a negligible clock laser induced light shift of few 10 -19 .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [46]
The citation is attached to the light-shift coefficient, not the lifetime or the citing authors’ estimate. Section 3.1 (page unavailable) gives the clock-laser coefficient as +13(2) Hz (W cm⁻²)⁻¹, whereas the citing sentence gives −13; the magnitudes agree, but the signs are opposite. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · see citing works
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903 · see citing works
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828 · see citing works
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 576 · see citing works
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554 · see citing works
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. R. (2004) · Science · doi:10.1126/science.1105497 · Cited by 302 · see citing works
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279 · see citing works
Sub-Hertz Optical Frequency Comparisons between Two Trapped Yb+171 Ions
Schneider, T., Peik, E., & Tamm, C. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.230801 · Cited by 205 · see citing works
Nuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186 · see citing works
Suppression of Collisional Shifts in a Strongly Interacting Lattice Clock
Swallows, M. D., Bishof, M., Lin, Y., Blatt, S., Martin, M. J., Rey, A. M., & Ye, J. (2011) · Science · doi:10.1126/science.1196442 · Cited by 181 · see citing works
Blakestad, R. B., Ospelkaus, C., VanDevender, A. P., Amini, J. M., Britton, J., Leibfried, D., & Wineland, D. J. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.153002 · Cited by 167 · see citing works
Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
Weyers, S., bner, U. H., der, R. S., Tamm, C., & Bauch, A. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/7 · Cited by 160 · see citing works
Self-citationThe absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 153 · see citing works
Cascaded multiplexed optical link on a telecommunication network for frequency dissemination
Lopez, O., Haboucha, A., Kéfélian, F., Jiang, H., Chanteau, B., Roncin, V., Chardonnet, C., Amy‐Klein, A., & Santarelli, G. (2010) · Optics Express · doi:10.1364/oe.18.016849 · Cited by 143 · see citing works
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10−17 Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137 · see citing works
Recoil-Limited Laser Cooling of Sr87 Atoms near the Fermi Temperature
Mukaiyama, T., Katori, H., Ido, T., Li, Y., & Kuwata‐Gonokami, M. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.113002 · Cited by 131 · see citing works
Ultra-low-noise microwave extraction from fiber-based optical frequency comb
Millo, J., Boudot, R., Lours, M., Bourgeois, P. Y., Luiten, A. N., Coq, Y. L., Kersalé, Y., & Santarelli, G. (2009) · Optics Letters · doi:10.1364/ol.34.003707 · Cited by 125 · see citing works
Probing Interactions Between Ultracold Fermions
Campbell, G. K., Boyd, M. M., Thomsen, J. W., Martin, M. J., Blatt, S., Swallows, M. D., Nicholson, T., Fortier, T. M., Oates, C. W., Diddams, S. A., et al. (2009) · Science · doi:10.1126/science.1169724 · Cited by 121 · see citing works
Hyperpolarizability Effects in a Sr Optical Lattice Clock
Brusch, A., Targat, R. L., Baillard, X., Fouché, M., & Lemonde, P. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.103003 · Cited by 120 · see citing works
Calcium optical frequency standard with ultracold atoms: Approaching 10−15 relative uncertainty
Degenhardt, C., Stoehr, H., Lisdat, C., Wilpers, G., Schnatz, H., Lipphardt, B., Nazarova, T., Pottie, P.-É., Sterr, U., Helmcke, J., et al. (2005) · Physical Review A · doi:10.1103/physreva.72.062111 · Cited by 117 · see citing works
Self-citationOptical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114 · see citing works
Measuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer
Hong, F.-L., Musha, M., Takamoto, M., Inaba, H., Yanagimachi, S., Takamizawa, A., Watabe, K.-I., Ikegami, T., Imae, M., Fujii, Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000692 · Cited by 113 · see citing works
An optical lattice clock with spin-polarized 87Sr atoms
Baillard, X., Fouché, M., Targat, R. L., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, D., Laurent, P., Rosenbusch, P., et al. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00330-3 · Cited by 112 · see citing works
Self-citationAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100 · see citing works
Total variance, an estimator of long-term frequency stability [standards]
Greenhall, C. A., Howe, D. A., & Percival, D. B. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.796124 · Cited by 89 · see citing works
Collisional Losses, Decoherence, and Frequency Shifts in Optical Lattice Clocks with Bosons
Lisdat, C., Winfred, J. S. R. V., Middelmann, T., Riehle, F., & Sterr, U. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.090801 · Cited by 87 · see citing works
Self-citationWeyers, S., Lipphardt, B., & Schnatz, H. (2009) · Physical Review A · doi:10.1103/physreva.79.031803 · Cited by 86 · see citing works
Self-citationDetermination of Sr properties for a high-accuracy optical clock
Porsev, S. G., Ludlow, A. D., Boyd, M. M., & Ye, J. (2008) · Physical Review A · doi:10.1103/physreva.78.032508 · Cited by 79 · see citing works
Decoherence and Collisional Frequency Shifts of Trapped Bosons and Fermions
Gibble, K. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.113202 · Cited by 78 · see citing works
Cancellation of the Collisional Frequency Shift in Caesium Fountain Clocks
Szymaniec, K., Chałupczak, W., Tiesinga, E., Williams, C. J., Weyers, S., & Wynands, R. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.153002 · Cited by 69 · see citing works
Self-citationTackling the Blackbody Shift in a Strontium Optical Lattice Clock
Middelmann, T., Lisdat, C., Falke, S., Winfred, J. S. R. V., Riehle, F., & Sterr, U. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2088470 · Cited by 62 · see citing works
Self-citationDemonstration of a transportable 1 Hz-linewidth laser
Vogt, S., Lisdat, C., Legero, T., Sterr, U., Ernsting, I., Nevsky, A. Y., & Schiller, S. (2011) · Applied Physics B · doi:10.1007/s00340-011-4652-7 · Cited by 61 · see citing works
Self-citationТайченачев, А. В., Yudin, V. I., Ovsiannikov, V. D., Pal'chikov, V. G., & Oates, C. W. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.193601 · Cited by 56 · see citing works
Many-Body Treatment of the Collisional Frequency Shift in Fermionic Atoms
Rey, A. M., Gorshkov, A. V., & Rubbo, C. P. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.260402 · Cited by 49 · see citing works
Three dimensional cooling and trapping with a narrow line
Chanelière, T., He, L., Kaiser, R., & Wilkowski, D. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00329-8 · Cited by 35 · see citing works
Influence of Chirped Excitation Pulses in an Optical Clock With Ultracold Calcium Atoms
Degenhardt, C., Nazarova, T., Lisdat, C., Stoehr, H., Sterr, U., & Riehle, F. (2005) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2004.843388 · Cited by 31 · see citing works
Self-citationRecent atomic clock comparisons at NIST
Lorini, L., Ashby, N., Brusch, A., Diddams, S. A., Drullinger, R. E., Eason, E., Fortier, T. M., Hastings, P., Heavner, T. P., Hume, D. B., et al. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00807-7 · Cited by 29 · see citing works
Pape, A., Terra, O., Friebe, J., Riedmann, M., Wübbena, T., Rasel, E. M., Predehl, K., Legero, T., Lipphardt, B., Schnatz, H., et al. (2010) · Optics Express · doi:10.1364/oe.18.021477 · Cited by 27 · see citing works
Self-citationOptical frequency synthesis and measurement using fibre-based femtosecond lasers
Grosche, G., Lipphardt, B., & Schnatz, H. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2008-00065-7 · Cited by 25 · see citing works
Self-citationCryogenic fountain development at NIST and INRIM: preliminary characterization
Levi, F., Calosso, C. E., Calonico, D., Lorini, L., Bertacco, E. K., Godone, A., Costanzo, G. A., Mongino, B., Jefferts, S. R., Heavner, T. P., et al. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1453 · Cited by 22 · see citing works
Interrogation Laser for a Strontium Lattice Clock
Legero, T., Lisdat, C., Winfred, J. S. R. V., Schnatz, H., Grosche, G., Riehle, F., & Sterr, U. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2007042 · Cited by 19 · see citing works
Self-citationSpecular Spectral Reflectance Of ALS1304 Stainless Steel At Near-Normal Incidence
Namba, Y. (1983) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.934138 · Cited by 5 · see citing works
Rey, A. M., Gorshkov, A. V., & Rubbo, C. P. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.049901 · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 3
- Gill P and Riehle F 2006 Proc. 2006 Meeting of the European Frequency and Time Forum (Braunschweig, Germany) pp 282-8 available at http://www.eftf.org/proceeding/ index.html
- Weyers S, Bauch A, Schröder R and Tamm C 2002 Frequency Standards and Metrology, Proc. 6th Symp. ed P Gill (Singapore: World Scientific) pp 64-71
- Namba Y 1982 Proc. SPIE 362 93
Cited by
Sorted by citations
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385 · see citing works
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · see citing works
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · see citing works
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · see citing works
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495 · see citing works
Self-citationNew Method for Gravitational Wave Detection with Atomic Sensors
Graham, P. W., Hogan, J. M., Kasevich, M. A., & Rajendran, S. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.171102 · Cited by 346 · see citing works
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324 · see citing works
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281 · see citing works
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250 · see citing works
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238 · see citing works
Self-citationMatter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)
Abe, M., Adamson, P., Borcean, M., Bortoletto, D., Bridges, K., Carman, S. P., Chattopadhyay, S., Coleman, J. P., Curfman, N. M., DeRose, K., et al. (2021) · Quantum Science and Technology · doi:10.1088/2058-9565/abf719 · Cited by 243 · see citing works
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174 · see citing works
Self-citationA strontium lattice clock with 3 × 10<sup>−17</sup>inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182 · see citing works
Self-citationHigh Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 153 · see citing works
Self-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149 · see citing works
Self-citationBlackbody-radiation shift in the Sr optical atomic clock
Safronova, M. S., Porsev, S. G., Safronova, M. S., Kozlov, M. G., & Clark, C. W. (2013) · Physical Review A · doi:10.1103/physreva.87.012509 · Cited by 140 · see citing works
Towards the optical second: verifying optical clocks at the SI limit
McGrew, W. F., Zhang, X., Leopardi, H., Fasano, R., Nicolodi, D., Beloy, K., Yao, J., Sherman, J. A., Schäffer, S. A., Savory, J., et al. (2019) · Optica · doi:10.1364/optica.6.000448 · Cited by 134 · see citing works
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102 · see citing works
Optical atomic clocksPreprint
Poli, N., Oates, C. W., Gill, P. R., & Tino, G. M. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1401.2378 · Cited by 93 · see citing works
Noise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84 · see citing works
Self-citationMatsubara, K., Hachisu, H., Li, Y., Nagano, S., Locke, C., Nogami, A., Kajita, M., Hayasaka, K., Ido, T., & Hosokawa, M. (2012) · Optics Express · doi:10.1364/oe.20.022034 · Cited by 87 · see citing works
Optical frequency standards for time and length applications
Hong, F.-L. (2016) · Measurement Science and Technology · doi:10.1088/1361-6501/28/1/012002 · Cited by 84 · see citing works
Contributing to TAI with a secondary representation of the SI second
Guéna, J., Abgrall, M., Clairon, A., & Bize, S. (2014) · Metrologia · doi:10.1088/0026-1394/51/1/108 · Cited by 81 · see citing works
Ultrastable laser with average fractional frequency drift rate below 5 × 10^−19/s
Hagemann, C., Grebing, C., Lisdat, C., Falke, S., Legero, T., Sterr, U., Riehle, F., Martin, M. J., & Ye, J. (2014) · Optics Letters · doi:10.1364/ol.39.005102 · Cited by 78 · see citing works
Self-citationPark, C. Y., Yu, D., Lee, W., Park, S. E., Kim, E. B., Lee, S. K., Cho, J. W., Yoon, T. H., Mun, J., Park, S. J., et al. (2013) · Metrologia · doi:10.1088/0026-1394/50/2/119 · Cited by 74 · see citing works
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72 · see citing works
Self-citationScattering of Cold-Atom Coherences by Hot Atoms: Frequency Shifts from Background-Gas Collisions
Gibble, K. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.180802 · Cited by 72 · see citing works
Observation and cancellation of a perturbing dc stark shift in strontium optical lattice clocks
Lodewyck, J., Zawada, M., Lorini, L., Gurov, M., & Lemonde, P. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2209 · Cited by 72 · see citing works
Determination of the 5d6s 3D1 state lifetime and blackbody-radiation clock shift in Yb
Beloy, K., Sherman, J. A., Lemke, N., Hinkley, N., Oates, C. W., & Ludlow, A. D. (2012) · Physical Review A · doi:10.1103/physreva.86.051404 · Cited by 68 · see citing works
Kuraptsev, A. S., & Sokolov, I. M. (2014) · Physical Review A · doi:10.1103/physreva.90.012511 · Cited by 67 · see citing works
First Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM
Lin, Y., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Zang, E., Sun, Z. G., Fang, F., Li, T., & Fang, Z. (2015) · Chinese Physics Letters · doi:10.1088/0256-307x/32/9/090601 · Cited by 66 · see citing works
Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64 · see citing works
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64 · see citing works
Self-citationDemonstration of a transportable 1 Hz-linewidth laser
Vogt, S., Lisdat, C., Legero, T., Sterr, U., Ernsting, I., Nevsky, A. Y., & Schiller, S. (2011) · Applied Physics B · doi:10.1007/s00340-011-4652-7 · Cited by 61 · see citing works
Self-citationLattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60 · see citing works
Self-citationA compact and efficient strontium oven for laser-cooling experiments
Schioppo, M., Poli, N., Prevedelli, M., Falke, S., Lisdat, C., Sterr, U., & Tino, G. M. (2012) · Review of Scientific Instruments · doi:10.1063/1.4756936 · Cited by 60 · see citing works
Self-citationYamaguchi, A., Shiga, N., Nagano, S., Li, Y., Ishijima, H., Hachisu, H., Kumagai, M., & Ido, T. (2012) · Applied Physics Express · doi:10.1143/apex.5.022701 · Cited by 60 · see citing works
Delivering pulsed and phase stable light to atoms of an optical clock
Falke, S., Misera, M., Sterr, U., & Lisdat, C. (2012) · Applied Physics B · doi:10.1007/s00340-012-4952-6 · Cited by 57 · see citing works
Self-citationDirect comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53 · see citing works
Self-citationHachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53 · see citing works
Providing $10^{-16}$ Short-Term Stability of a 1.5-$\mu\hbox{m}$ Laser to Optical Clocks
Hagemann, C., Grebing, C., Keßler, T., Falke, S., Lemke, N., Lisdat, C., Schnatz, H., Riehle, F., & Sterr, U. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2242597 · Cited by 52 · see citing works
Self-citationAkamatsu, D., Inaba, H., Hosaka, K., Yasuda, M., Onae, A., Suzuyama, T., Amemiya, M., & Hong, F.-L. (2013) · Applied Physics Express · doi:10.7567/apex.7.012401 · Cited by 50 · see citing works
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48 · see citing works
Frequency ratio measurement of ^171Yb and ^87Sr optical lattice clocks
Akamatsu, D., Yasuda, M., Inaba, H., Hosaka, K., Tanabe, T., Onae, A., & Hong, F.-L. (2014) · Optics Express · doi:10.1364/oe.22.007898 · Cited by 48 · see citing works
Hobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P. R., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 48 · see citing works
A low maintenance Sr optical lattice clock
Hill, I. R., Hobson, R., Bowden, W., Bridge, E. M., Donnellan, S., Curtis, E. A., & Gill, P. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012019 · Cited by 37 · see citing works
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33 · see citing works
“9(4) × 10 − 17 .”
Self-citationThe CIPM list ‘Recommended values of standard frequencies’: 2021 update
Margolis, H. S., Panfilo, G., Petit, G., Oates, C. W., Ido, T., & Bize, S. (2024) · Metrologia · doi:10.1088/1681-7575/ad3afc · Cited by 29 · see citing works
Zeeman slowers for strontium based on permanent magnets
Hill, I. R., Ovchinnikov, Y. B., Bridge, E. M., Curtis, E. A., & Gill, P. (2014) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/47/7/075006 · Cited by 28 · see citing works
Skomorowski, W., Moszyński, R., & Koch, C. P. (2012) · Physical Review A · doi:10.1103/physreva.85.043414 · Cited by 28 · see citing works
Two-Color Grating Magneto-Optical Trap for Narrow-Line Laser Cooling
Bondza, S., Lisdat, C., Kroker, S., & Leopold, T. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.044002 · Cited by 25 · see citing works
Self-citationA Novel Scheme for Hundred-Hertz Linewidth Measurements with the Self-Heterodyne Method
Peng, Y. (2013) · Chinese Physics Letters · doi:10.1088/0256-307x/30/8/084208 · Cited by 24 · see citing works
Dynamical decoupling of laser phase noise in compound atomic clocks
Dörscher, S., Al-Masoudi, A., Bober, M., Schwarz, R., Hobson, R., Sterr, U., & Lisdat, C. (2020) · Communications Physics · doi:10.1038/s42005-020-00452-9 · Cited by 23 · see citing works
Self-citationCoherent Excitation of the Highly Forbidden Electric Octupole Transition in Yb+172
Fürst, H. A., Yeh, C.-H., Kalincev, D., Kulosa, A. P., Dreissen, L. S., Lange, R., Benkler, E., Huntemann, N., Peik, E., & Mehlstäubler, T. E. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.163001 · Cited by 23 · see citing works
Long-range transport of ultracold atoms in a far-detuned one-dimensional optical lattice
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/7/073020 · Cited by 23 · see citing works
Self-citationA transportable optical lattice clock at the National Time Service Center*
Kong, D., Wang, Z., Guo, F., Zhang, Q., Lu, X., Wang, Y., & Chang, H. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab9290 · Cited by 20 · see citing works
Development of 8-branch Er:fiber frequency comb for Sr and Yb optical lattice clocks
Hisai, Y., Akamatsu, D., Kobayashi, T., Okubo, S., Inaba, H., Hosaka, K., Yasuda, M., & Hong, F.-L. (2019) · Optics Express · doi:10.1364/oe.27.006404 · Cited by 18 · see citing works
Cold atom clocks and their applications in precision measurements*
Dai, S., Zheng, F., Liu, K., Chen, W., Lin, Y., Li, T., & Fang, F. (2020) · Chinese Physics B · doi:10.1088/1674-1056/abbbee · Cited by 18 · see citing works
Magic Radio-Frequency Dressing of Nuclear Spins in High-Accuracy Optical Clocks
Zanon-Willette, T., de Clercq, E., & Arimondo, E. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.223003 · Cited by 18 · see citing works
Reducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles
Zheng, X., Dolde, J., & Kolkowitz, S. (2024) · Physical Review X · doi:10.1103/physrevx.14.011006 · Cited by 17 · see citing works
Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms
Akamatsu, D., Kobayashi, T., Hisai, Y., Tanabe, T., Hosaka, K., Yasuda, M., & Hong, F.-L. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2819888 · Cited by 16 · see citing works
Characterization of the Frequency Stability of a Multibranch Optical Frequency Comb
Terra, O. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2986422 · Cited by 15 · see citing works
Clock-transition spectrum of171Yb atoms in a one-dimensional optical lattice
Chen, N., Zhou, M., Chen, H.-Q., Fang, S., Huang, L., Zhang, X., Gao, Q., Jiang, Y.-Y., Bi, Z., Ma, L.-S., et al. (2013) · Chinese Physics B · doi:10.1088/1674-1056/22/9/090601 · Cited by 14 · see citing works
Achromatic, planar Fresnel-reflector for a single-beam magneto-optical trap
Bondza, S., Leopold, T., Schwarz, R., & Lisdat, C. (2024) · Review of Scientific Instruments · doi:10.1063/5.0174674 · Cited by 12 · see citing works
Self-citationUrbańczyk, T., Strojecki, M., Krośnicki, M., Kędziorski, A., Żuchowski, P. S., & Koperski, J. (2017) · International Reviews in Physical Chemistry · doi:10.1080/0144235x.2017.1337371 · Cited by 13 · see citing works
Yuan, Y., Cui, K., Liu, D., Yuan, J., Cao, J. Z., Wang, D., Chao, S., Shu, H., & Huang, X.-R. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.044052 · Cited by 12 · see citing works
Robertsson, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1272 · Cited by 12 · see citing works
Lu, X., Yin, M.-J., Li, T., Wang, Y., & Chang, H. (2020) · Applied Sciences · doi:10.3390/app10041440 · Cited by 12 · see citing works
International timescales with optical clocks (ITOC)
Margolis, H. S., Godun, R. M., Gill, P., Johnson, L. A. M., Shemar, S. L., Whibberley, P. B., Calonico, D., Levi, F., Lorini, L., Pizzocaro, M., et al. (2013) · 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC) · doi:10.1109/eftf-ifc.2013.6702183 · Cited by 15 · see citing works
Self-citationAtom interferometer as a freely falling clock for time-dilation measurements
Roura, A. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad9e2e · Cited by 10 · see citing works
Analysis of the blackbody-radiation shift in an ytterbium optical lattice clock
Xu, Y., & Xu, X. (2016) · Chinese Physics B · doi:10.1088/1674-1056/25/10/103202 · Cited by 10 · see citing works
Optical Lattice Clocks as Candidates for a Possible Redefinition of the SI Second
Gurov, M., McFerran, J. J., Nagórny, B., Tyumenev, R., Xu, Z., Coq, Y. L., Targat, R. L., Lemonde, P., Lodewyck, J., & Bize, S. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2242638 · Cited by 9 · see citing works
Transportable strontium lattice clock with 4 × 10 − 19 blackbody radiation shift uncertainty
Nosske, I., Vishwakarma, C., Lücke, T., Rahm, J., Poudel, N., Weyers, S., Benkler, E., Dörscher, S., & Lisdat, C. (2025) · Quantum Science and Technology · doi:10.1088/2058-9565/ae1161 · Cited by 8 · see citing works
Self-citationCoherence transfer from 1064 nm to 578 nm using an optically referenced frequency comb
Fang, S., Jiang, Y., Chen, H.-Q., Yao, Y., Bi, Z., & Ma, L.-S. (2015) · Chinese Physics B · doi:10.1088/1674-1056/24/7/074202 · Cited by 8 · see citing works
Strontium optical lattice clock
Yi-Ge, L., & Fang, Z. (2018) · Acta Physica Sinica · doi:10.7498/aps.67.20181097 · Cited by 8 · see citing works
Kahmann, M., Tiemann, E., Appel, O., Sterr, U., & Riehle, F. (2014) · Physical Review A · doi:10.1103/physreva.89.023413 · Cited by 8 · see citing works
Self-citationLu, X., Yin, M.-J., Li, T., Wang, Y., & Chang, H. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab98d8 · Cited by 8 · see citing works
Lu, X., Zhou, C., Li, T., Wang, Y., & Chang, H. (2020) · Applied Physics Letters · doi:10.1063/5.0025097 · Cited by 8 · see citing works
Comparison of two Strontium optical lattice clocks in agreement at the 10−16 level
Targat, R. L., Lorini, L., Gurov, M., Zawada, M., Gartman, R., Nagórny, B., Lemonde, P., & Lodewyck, J. (2012) · European Frequency and Time Forum · doi:10.1109/eftf.2012.6502324 · Cited by 7 · see citing works
A compact and robust cooling laser system for an optical strontium lattice clock
Schwarz, R., Dörscher, S., Al-Masoudi, A., Vogt, S., Li, Y., & Lisdat, C. (2019) · Review of Scientific Instruments · doi:10.1063/1.5063552 · Cited by 7 · see citing works
Self-citationPROPOSAL: P-1101 Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)
Adamson, P., Northwestern, U., Liverpool, U., UC, B., Northern Illinois, U., Stanford, U., Chattopadhyay, S., Coleman, J. P., Graham, P. W., Geer, S., et al. (2018) · doi:10.2172/1605586 · Cited by 7 · see citing works
Subhertz-linewidth infrared frequency source with a long-term instability below 5 × 10−15
Raupach, S. M. F., Legero, T., Grebing, C., Hagemann, C., Keßler, T., Koczwara, A., Lipphardt, B., Misera, M., Schnatz, H., Grosche, G., et al. (2012) · Applied Physics B · doi:10.1007/s00340-012-5280-6 · Cited by 6 · see citing works
Self-citationMagneto-optical trapping of strontium for use as a mobile frequency reference
Kock, B. O. (2013) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 6 · see citing works
A sub-40 mHz laser based on a silicon single-crystal optical cavity
Keßler, T., Hagemann, C., Sterr, U., Riehle, F., Martin, M. J., & Ye, J. (2012) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2012.6250907 · Cited by 5 · see citing works
Self-citationResearch progress on active optical clocks
Chen, J., & Zhang, W. (2015) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/n972014-00865 · Cited by 4 · see citing works
Lu, B., Lu, X., Li, J., & Chang, H. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac29a6 · Cited by 4 · see citing works
Zhou, C., Lu, X., Lu, B., Wang, Y., & Chang, H. (2021) · Applied Sciences · doi:10.3390/app11031206 · Cited by 4 · see citing works
Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI LimitPreprint
McGrew, W. F., Zhang, X., Leopardi, H., Fasano, R., Nicolodi, D., Beloy, K., Yao, J., Sherman, J. A., Schäffer, S. A., Savory, J., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1811.05885 · Cited by 4 · see citing works
Analysis of inhomogeneous-excitation frequency shifts of ytterbium optical lattice clocks
Chen, N., & Xu, X. (2014) · Laser Physics Letters · doi:10.1088/1612-2011/12/1/015501 · Cited by 3 · see citing works
Guodong, 赵. Z., Lu, X., & Chang, H. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop223237 · Cited by 3 · see citing works
Building a better atomic clock
Bloom, B. (2013) · Physics Today · doi:10.1063/pt.5.027159 · Cited by 3 · see citing works
Optical Lattice Clocks for Precision Time and Frequency Metrology
Takamoto, M., & Katori, H. (2015) · Lecture notes in physics · doi:10.1007/978-4-431-55756-2_5 · Cited by 3 · see citing works
Bilicki, S. (2017) · theses.fr (ABES) · doi:10.70675/4b3e81f4z8872z4d16z8156z517133a256ac · Cited by 4 · see citing works
Determining the Magic Wavelength Without Modulation of the Trap Depth
Xia, J., Guo, F., Zhou, Y., Lu, X., & Chang, H. (2024) · Optics · doi:10.3390/opt5040040 · Cited by 2 · see citing works
Noise-induced servo errors in optical clocks utilizing Rabi interrogation
Lindvall, T., Wallin, A. E., Hanhijärvi, K., & Fordell, T. (2023) · Metrologia · doi:10.1088/1681-7575/acdfd4 · Cited by 2 · see citing works
Arora, P., & Gupta, A. S. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_21 · Cited by 2 · see citing works
Peng, C., Zhang, T., Sun, C., Qi, Q., Jin, T., Lei, S., Zhao, C., Feng, S., Xia, Y., & Xu, X. (2024) · Applied Physics Letters · doi:10.1063/5.0222370 · Cited by 2 · see citing works
Effect of Thermal Fields on the Shift of Optical Standards of Frequency
Gurov, M., Gurova, E. G., & Дмитриев, А. К. (2015) · Russian Physics Journal · doi:10.1007/s11182-015-0442-8 · Cited by 2 · see citing works
Ido, T., Fujieda, M., Hachisu, H., Nagano, S., Gotoh, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., Lisdat, C., et al. (2014) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2014.6859906 · Cited by 2 · see citing works
Self-citationOptical Сlocks and Thermal Fields Impact
Gurov, M., & Gurova, E. G. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.698.561 · Cited by 2 · see citing works
- Authors
- Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2011-09-12
- Volume
- 48
- Issue
- 5
- Pages
- 399-407
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2016860894
- Cited by
- 129
- References
- 43
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 9 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 11 · 2019: 6 · 2018: 9 · 2017: 4 · 2016: 9 · 2015: 11 · 2014: 16 · 2013: 19 · 2012: 19
- FWCI
- 9.55
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- strontium-87, optical frequency standard, optical clock transition, one-dimensional optical lattice, femtosecond optical frequency comb, cesium fountain clock, atomic clocks
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review