Cited by 1Forensic Toxicology and Drug AnalysisBiosensors and Analytical DetectionOpioid Use Disorder Treatment

Decoding the Unseen: A Systematic Review of the Analytical Performance of Nitazene Test Strips for Identifying Synthetic Opioids in Seized Drug Materials

Open access
Al-Juhani, Abdulkreem, Alasmari, Abdulelah, Aljohani, Omar O, Hakeem, Hatoon, Desoky, Rodan, Badghaish, Muhannad A, Aljohani, Naif, Alanazi, Fai A·2025·Cureus

Abstract

Nitazenes are highly potent synthetic opioids increasingly detected in illicit drug markets and associated with significant public-health and forensic challenges. Rapid identification tools, such as lateral-flow immunoassay (LFA) test strips, are widely used in harm-reduction and forensic settings; however, their analytical performance for detecting nitazene-class opioids remains insufficiently characterized. This systematic review aims to evaluate the analytical performance of nitazene LFA test strips when used on seized drug materials and laboratory-prepared solutions, compared with mass spectrometry (MS) reference methods (liquid chromatography-tandem mass spectrometry (LC-MS/MS), liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF-MS), and gas chromatography-mass spectrometry (GC-MS)). Outcomes included sensitivity, specificity, cross-reactivity, limits of detection, and operational interferences. Adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses - Diagnostic-Test Accuracy (PRISMA-DTA) guidelines and applying Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) framework, five eligible studies were synthesized, including laboratory evaluations and field-paired analyses. Only studies evaluating LFAs on drug materials - not biological samples - were included. Our results showed that two studies provided paired LFA-mass-spectrometry datasets. Under concentrated preparation conditions (10 mg/1 mL), LFAs demonstrated complete agreement with MS. Sensitivity declined at higher dilution (10 mg/5 mL), while specificity remained high. Analytical detectability varied substantially across nitazene analogues, with N-desethyl-metonitazene exhibiting the greatest sensitivity. Matrix effects, caffeine adulteration (~300 µg/mL), solvent concentrations >10% acetonitrile, and elevated temperatures all reduced line intensity or hindered wicking. In conclusion, Nitazene LFA test strips show potential value as preliminary material-based screening tools in forensic and harm-reduction applications, but should not be interpreted as confirmatory. Their use requires standardized protocols, conservative interpretation rules, and mandatory mass-spectrometric confirmation. Large, independent, multi-site analytical validation studies are needed to establish reliability, optimize field use, and support integration into drug-checking programs.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7759/cureus.99109

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Nitazene immunoassay test strips detected 28 of 36 nitazene compounds, showing partial effectiveness as rapid screening tools.

    “Recent work on nitazene immunoassays test strips show partial effectiveness as a rapid screening tools, with these strips detecting 28 of 36 nitazene compounds [43].”

    From Novel 2-Benzylbenzimidazole Opioids: Emerging Drugs of Abuse and Pharmacological Considerations with Nitazene Analogs (2026) · cites this paper as [43]

    The Review’s analogue-level detection section reports that 24 of 33 nitazene analogues were identified at concentrations below 9000 ng/mL, not that 28 of 36 were detected. The Conclusions support the broader point that the strips may serve as preliminary screening tools, subject to confirmatory testing. The claimed detection count is unsupported by our copy. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • Nitazene immunoassay test strip performance limitations include false negatives and false positives linked to high caffeine concentrations.

    “However, performance limitations are observed, with false negatives, and false positives, both being linked to high caffeine concentrations [43].”

    From Novel 2-Benzylbenzimidazole Opioids: Emerging Drugs of Abuse and Pharmacological Considerations with Nitazene Analogs (2026) · cites this paper as [43]

    The Review’s “Interferences, Matrix Effects, and Operational Findings” section and Table 4 link caffeine at about 300 µg/mL to a false-negative risk. The paper discusses false positives generally, but the cited passages do not link them to high caffeine concentrations; the paired accuracy data report no false positives. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 31

  1. [5]Beyond fentanyl test strips: investigating other urine drug test strips for drug checking applications Forensic Chem Sisco E Appley MG Pyfrom EM 40 2024 https://doi.org/10.1016/j.forc.2024.100594 PMC11450658 39371371 · DOI · Paper page
  2. [7]Validation of a lateral flow chromatographic immunoassay for the detection of fentanyl in drug samples Drug Alcohol Depend Park JN Sherman SG Sigmund V Breaud A Martin K Clarke WA 109610 240 2022 https://doi.org/10.1016/j.drugalcdep.2022.109610 36115223 PMC9588631 · DOI · Paper page
  3. [9]Mu-opioid receptor selective superagonists produce prolonged respiratory depression iScience Malcolm NJ Palkovic B Sprague DJ 107121 26 2023 37416459 PMC10320493
  4. [10]The emergence of nitazenes: a new chapter in the synthetic opioid crisis Arch Toxicol Caprari C Ferri E Rossetti P Gregori A Citti C Cannazza G 3877 3896 99 2025 40490529
  5. [11]Rapid GC-MS method for screening seized drugs in forensic investigations: optimization and validation Front Chem Askar AM Al Ali AY Khalifa MK Salem AA Alkhuwaildi BM Shah I 1559279 13 2025 40556732 PMC12185466
  6. [13]Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement JAMA McInnes MD Moher D Thombs BD 388 396 319 2018 29362800
  7. [14]QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies Ann Intern Med Whiting PF Rutjes AW Westwood ME 529 536 155 2011 22007046
  8. [15]Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey Anal Bioanal Chem Posthuma-Trumpie GA Korf J van Amerongen A 569 582 393 2009 18696055
  9. [16]Lateral flow assays Essays Biochem Koczula KM Gallotta A 111 120 60 2016 27365041 PMC4986465
  10. [17]Isotonitazene quantitation and metabolite discovery in authentic forensic casework J Anal Toxicol Krotulski AJ Papsun DM Kacinko SL Logan BK 521 530 44 2020 32091095
  11. [19]Analytical characterization of "etonitazepyne," a new pyrrolidinyl-containing 2-benzylbenzimidazole opioid sold online Drug Test Anal Blanckaert P Balcaen M Vanhee C 1627 1634 13 2021 34145779
  12. [20]Intoxications in an Australian Emergency Department involving 'nitazene' benzylbenzimidazole synthetic opioids (etodesnitazene, butonitazene and protonitazene) J Anal Toxicol Schumann JL Syrjanen R Alford K 0 9 47 2023 35983900
  13. [23]An assessment of the limits of detection, sensitivity and specificity of three devices for public health-based drug checking of fentanyl in street-acquired samples Int J Drug Policy Green TC Park JN Gilbert M 102661 77 2020 31951925
  14. [24]Fentanyl test strips as an opioid overdose prevention strategy: findings from a syringe services program in the Southeastern United States Int J Drug Policy Peiper NC Clarke SD Vincent LB Ciccarone D Kral AH Zibbell JE 122 128 63 2019 30292493
  15. [25]High willingness to use rapid fentanyl test strips among young adults who use drugs Harm Reduct J Krieger MS Yedinak JL Buxton JA 7 15 2018 29422052 PMC5806485
  16. [26]Testing the test strips: laboratory performance of fentanyl test strips Harm Reduct J Halifax JC Lim L Ciccarone D Lynch KL 14 21 2024 38238757 PMC10795297
  17. [27]Assessment of two brands of fentanyl test strips with 251 synthetic opioids reveals "blind spots" in detection capabilities Harm Reduct J Hayes KL Lieberman M 175 20 2023 38057832 PMC10702106
  18. [28]Selectivity and sensitivity of urine fentanyl test strips to detect fentanyl analogues in illicit drugs Int J Drug Policy Bergh MS Øiestad ÅML Baumann MH Bogen IL 103065 90 2021 33333419
  19. [29]Evaluating the sensitivity, stability, and cross-reactivity of commercial fentanyl immunoassay test strips J Forensic Sci Rodriguez-Cruz SE 1555 1569 68 2023 37420315
  20. [30]Validation of an analytical method for quantitation of metonitazene and isotonitazene in plasma, blood, urine, liver and brain and application to authentic postmortem casework in New York City J Anal Toxicol Pardi J Ford S Cooper G 648 655 47 2023 37638699
  21. [31]Scientific Working Group for Forensic Toxicology (SWGTOX) standard practices for method validation in forensic toxicology J Anal Toxicol 452 474 37 2013 23934984
  22. [32]ANSI/ASB Standard 036 for method validation in forensic toxicology has replaced SWGTOX's version J Anal Toxicol LeBeau MA 414 44 2020 32091110
  23. [33]Assessing the limit of detection of Fourier-transform infrared spectroscopy and immunoassay strips for fentanyl in a real-world setting Drug Alcohol Rev McCrae K Tobias S Grant C Lysyshyn M Laing R Wood E Ti L 98 102 39 2020 31746056
  24. [34]Fentanyl test strip use and overdose risk reduction behaviors among people who use drugs JAMA Netw Open Vickers-Smith RA Gelberg KH Childerhose JE 0 8 2025 PMC12076174 40358945
  25. [35]A lot testing protocol for quality assurance of fentanyl test strips for harm reduction applications Harm Reduct J Fernando H Amate A Hayes KL 152 21 2024 39169393 PMC11337861
  26. [36]Highlighting variability in fentanyl test strip instructions using thematic content analysis Harm Reduct J Piercey CJ Pince CL Karoly HC 110 22 2025 40551121 PMC12186409
  27. [37]The use of confidence or fiducial limits Biometrika Clopper CJ Pearson ES 404 413 26 1934
  28. [38]Perspectives on rapid fentanyl test strips as a harm reduction practice among young adults who use drugs: a qualitative study Harm Reduct J Goldman JE Waye KM Periera KA Krieger MS Yedinak JL Marshall BD 3 16 2019 30621699 PMC6325714
  29. [39]Fentanyl test strip distribution acceptability and use among substance-related emergency department visits Acad Emerg Med Kannam A Cowett A Caruso K 925 928 31 2024 38708827
  30. [40]Clinical toxicity of nitazene detections in two Australian emergency department toxicosurveillance systems Drug Alcohol Rev Isoardi KZ Alfred S Weber C 0 45 2026 39828943
  31. [41]Prospective cohort study of fentanyl test strip use and distribution in three states: the stay safe study protocol and implementation recommendations for researchers Harm Reduct J Childerhose JE Gelberg K Vickers-Smith R 146 22 2025 40855432 PMC12379525

Cited by

Sorted by citations

Authors
Al-Juhani, A., Alasmari, A., Aljohani, O. O., Hakeem, H., Desoky, R., Badghaish, M. A., Aljohani, N., & Alanazi, F. A.
Affiliations
  • King Abdulaziz University (SA)
  • Ministry of Health (SA)
  • Prince Mohammed bin Abdulaziz Hospital (SA)
  • Alfaisal University (SA)
  • Naif Arab University for Security Sciences (SA)
Corresponding author
Al-Juhani, Abdulkreem
Venue
Cureus
Published
2025-12-13
Volume
17
Issue
12
Pages
e99109-e99109
ISSN
2168-8184 (ISSN-L)
OpenAlex
W7114996372
Cited by
1
References
7
Citations by year
2026: 1
FWCI
0.18
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Cureus (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Opioid Use Disorder Treatment
Keywords
nitazenes, synthetic opioids, lateral flow immunoassay, drug checking, diagnostic accuracy, sensitivity and specificity, matrix effects, harm reduction, forensic drug analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review