CoChat

Extended Transvaginal Sonography in Deep Infiltrating Endometriosis: Use of Bowel Preparation and an Acoustic Window With Intravaginal Gel: Preliminary Results

León, Mauricio, Vaccaro, Humberto, Alcázar, Juan Luis, Martinez, Jaime, Gutierrez, Jorge, Amor, Fernando, Iturra, Alberto, Sovino, Hugo · 2014 · Journal of Ultrasound in Medicine
Cited by 51

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objectives: The purpose of this study was to assess the diagnostic performance of extended transvaginal sonography for diagnosing deep infiltrating endometriosis. Methods: A prospective study was conducted comprising 51 women (mean age, 32.9 years; range, 23–43 years) with suspected deep infiltrating endometriosis based on clinical symptoms. All women underwent extended transvaginal sonography, which included assessment of 2 pelvic compartments (anterior compartment: bladder and distal ureters; and posterior compartment: posterior vaginal fornix, retrocervical area, pouch of Douglas, and rectosigmoid). The sliding sign for detecting pouch of Douglas obliteration was also assessed. All patients received bowel preparation before sonographic examinations. A single examiner performed all examinations. All women underwent laparoscopic surgery, and histologic confirmation of endometriosis was done. The sensitivity, specificity, positive likelihood ratio (LR+) and negative likelihood ratio (LR−) were calculated. Results: Some women had more than 1 lesion, giving a total of 55 histologically confirmed lesions (rectosigmoid, n = 13; vagina, n = 5; retrocervical, n = 32; bladder, n = 5). The sensitivity, specificity, and LR+ for rectosigmoid involvement were 100%, 93%, and 14.0, respectively. The sensitivity, specificity, LR+, and LR− for vaginal involvement were 60%, 98%, 30.0, and 0.41. The sensitivity, specificity, LR+, and LR− for retrocervical involvement were 84%, 96%, 19.4, and 0.16. The sensitivity, specificity, and LR− for bladder involvement were 20%, 100%, and 0.80. The sensitivity, specificity, LR+, and LR− of the sliding sign for diagnosing pouch of Douglas obliteration were 89%, 92%, 10.7, and 0.12. Conclusions: Except for bladder involvement, extended transvaginal sonography has good diagnostic performance for deep infiltrating endometriosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7863/ultra.33.2.315

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 51

Metadata

Authors
León, M., Vaccaro, H., Alcázar, J. L., Martinez, J., Gutierrez, J., Amor, F., Iturra, A., & Sovino, H.
Venue
Journal of Ultrasound in Medicine
Publisher
Wiley
Published
2014-02
Volume
33
Issue
2
Pages
315-321
ISSN
  • 0278-4297 (ISSN-L)
  • 1550-9613
OpenAlex
W2010664580
Cited by
51
References
6
FWCI
6.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extended Transvaginal Sonography in Deep Infiltrating Endometriosis: Use of Bowel Preparation and an Acoustic Window With Intravaginal Gel: Preliminary Results. https://app.cochat.ai/papers/10.7863/ultra.33.2.315
The paper
León, M., Vaccaro, H., Alcázar, J. L., Martinez, J., Gutierrez, J., Amor, F., Iturra, A., & Sovino, H. (2014). Extended Transvaginal Sonography in Deep Infiltrating Endometriosis: Use of Bowel Preparation and an Acoustic Window With Intravaginal Gel: Preliminary Results. Journal of Ultrasound in Medicine. https://doi.org/10.7863/ultra.33.2.315

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.