CoChat

Defining the Incidence of Cardiorespiratory Instability in Patients in Step-down Units Using an Electronic Integrated Monitoring System

Open access
Hravnak, Marilyn · 2008 · Archives of Internal Medicine
Cited by 132

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: To our knowledge, detection of cardiorespiratory instability using noninvasive monitoring via electronic integrated monitoring systems (IMSs) in intermediate or step-down units (SDUs) has not been described. We undertook this study to characterize respiratory status in an SDU population, to define features of cardiorespiratory instability, and to evaluate an IMS index value that should trigger medical emergency team (MET) activation. METHODS: This descriptive, prospective, single-blinded, observational study evaluated all patients in a 24-bed SDU in a university medical center during 8 weeks from November 16, 2006, to January 11, 2007. An IMS (BioSign; OBS Medical, Carmel, Indiana) was inserted into the standard noninvasive hardwired monitoring system and used heart rate, blood pressure, respiratory rate, and peripheral oxygen saturation by pulse oximetry to develop a single neural networked signal, or BioSign Index (BSI). Data were analyzed for cardiorespiratory instability according to BSI trigger value and local MET activation criteria. Staff were blinded to BSI data collected in 326 patients (total census). RESULTS: Data for 18 248 hours of continuous monitoring were captured. Data for peripheral oxygen saturation by pulse oximetry were absent in 30% of monitored hours despite being a standard of care. Cardiorespiratory status in most patients (243 of 326 [74.5%]) was stable throughout their SDU stay, and instability in the remaining patients (83 of 326 [25%]) was exhibited infrequently. We recorded 111 MET activation criteria events caused by cardiorespiratory instability in 59 patients, but MET activation for this cause occurred in only 7 patients. All MET events were detected by BSI in advance (mean, 6.3 hours) in a bimodal distribution (>6 hours and < or =45 minutes). CONCLUSIONS: Cardiorespiratory instability, while uncommon and often unrecognized, was preceded by elevation of the IMS index. Continuous noninvasive monitoring augmented by IMS provides sensitive detection of early instability in patients in SDUs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.168.12.1300

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 132

Metadata

Authors
Hravnak, M.
Venue
Archives of Internal Medicine
Published
2008-06-23
Volume
168
Issue
12
Pages
1300
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2070274899
Cited by
132
References
3
FWCI
13.90
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Defining the Incidence of Cardiorespiratory Instability in Patients in Step-down Units Using an Electronic Integrated Monitoring System. https://app.cochat.ai/papers/10.1001/archinte.168.12.1300
The paper
Hravnak, M. (2008). Defining the Incidence of Cardiorespiratory Instability in Patients in Step-down Units Using an Electronic Integrated Monitoring System. Archives of Internal Medicine. https://doi.org/10.1001/archinte.168.12.1300

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.