CoChat

Clinicians' Assessments of Electronic Medication Safety Alerts in Ambulatory Care

Weingart, Saul N., Simchowitz, Brett, Shiman, Lawrence, Brouillard, Daniela, Cyrulik, Adrienne, Davis, Roger B., Isaac, Thomas, Massagli, Michael, Morway, Laurinda, Sands, Daniel Z., Spencer, Justin, Weissman, Joel S. · 2009 · Archives of Internal Medicine
Cited by 93

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: While electronic prescribing (e-prescribing) systems with drug interaction and allergy alerts promise to improve medication safety in ambulatory care, clinicians often override these safety features. We undertook a study of respondents' satisfaction with e-prescribing systems, their perceptions of alerts, and their perceptions of behavior changes resulting from alerts. METHODS: Random sample survey of 300 Massachusetts ambulatory care clinicians who used a commercial e-prescribing system. RESULTS: A total of 184 respondents completed the survey (61%). Respondents indicated that e-prescribing improved the quality of care delivered (78%), prevented medical errors (83%), and enhanced patient satisfaction (71%) and clinician efficiency (75%). In addition, 35% of prescribers said that electronic alerts caused them to modify a potentially dangerous prescription in the last 30 days. They suggested that alerts also led to other changes in clinical care: counseling patients about potential reactions (49% of respondents), looking up information in medical references (44%), and changing the way a patient was monitored (33%). Altogether, 63% of clinicians reported taking action other than discontinuing or modifying an alerted prescription in the previous month in response to alerts. Despite these benefits, fewer than half of respondents were satisfied with drug interaction and allergy alerts (47%). Problems included alerts triggered by discontinued medications (58%), alerts that failed to account for appropriate drug combinations (46%), and excessive volume of alerts (37%). CONCLUSION: Although clinicians were critical of the quality of e-prescribing alerts, alerts may lead to clinically significant modifications in patient management not readily apparent based on "acceptance" rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinternmed.2009.300

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Improving Acceptance of Computerized Prescribing Alerts in Ambulatory Care

    Shah, N. R., Seger, A. C., Seger, D. L., Fiskio, J. M., Kuperman, G. J., Blumenfeld, B., Recklet, E. G., Bates, D. W., & Gandhi, T. K. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1868 · Cited by 353 · cited 6×

    “Alerts are not clinically relevant 160 21 (13) 26 (16) 41 (26) 72 (45) Alerts identify extremely rare complications 158 16 (10) 43 (27) 52 (33) 47 (30) Alerts are not based on persuasive scientific evidence 161 12 (7) 33 (20) 44 (27) 72 (45) Alerts offer recommendations that are contrary to guidelines or recommendatio…”
    BackgroundInfluential
  • Overrides of Medication Alerts in Ambulatory Care

    Isaac, T., Weissman, J. S., Davis, R. B., Massagli, M., Cyrulik, A., Sands, D. Z., & Weingart, S. N. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2008.551 · Cited by 309 · cited 3×

    “5 Practice duration, mean (SD) (range), y 22 (10) (2-46) Direct care time per week, mean (SD) (range), h 38 (12) (12-80) Comfort with computers and electronic technology Very comfortable 92 (52) Comfortable 56 (32) Somewhat comfortable 24 (14) Not at all comfortable 5 (3) Data missing, No.”
    BackgroundSelf-citation
  • Practitioners’ views on computerized drug-drug interaction alerts in the VA system

    Ko, Y., Abarca, J., Malone, D. C., Dare, D. C., Geraets, D., Houranieh, A., Jones, W. N., Nichol, W. P., Schepers, G. P., & Wilhardt, M. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2224 · Cited by 102 · cited 5×

    “In the last 30 days, how often has a drug allergy or interaction alert caused you to do any of the following? Counsel a patient about potential drug reactions or interactions 176 15 (9) 72 (41) 49 (28) 40 (23) Look something up in a drug or medical reference 175 13 (7) 64 (37) 51 (29) 47 (27) Write a new prescription…”
    BackgroundInfluential

Cited by

See all 93

Metadata

Authors
Weingart, S. N., Simchowitz, B., Shiman, L., Brouillard, D., Cyrulik, A., Davis, R. B., Isaac, T., Massagli, M., Morway, L., Sands, D. Z., Spencer, J., & Weissman, J. S.
Venue
Archives of Internal Medicine
Published
2009-09-28
Volume
169
Issue
17
Pages
1627-32
ISSN
0003-9926 (ISSN-L)
OpenAlex
W1980220833
Cited by
93
References
3
FWCI
22.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.