Association of Single- vs Dual-Chamber ICDs With Mortality, Readmissions, and Complications Among Patients Receiving an ICD for Primary Prevention
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Randomized trials of implantable cardioverter-defibrillators (ICDs) for primary prevention predominantly used single-chamber devices. In clinical practice, patients often receive dual-chamber ICDs, even without clear indications for pacing. The outcomes of dual- vs single-chamber devices are uncertain. OBJECTIVE: To compare outcomes of single- and dual-chamber ICDs for primary prevention of sudden cardiac death. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort study of admissions in the National Cardiovascular Data Registry's (NCDR) ICD registry from 2006-2009 that could be linked to Centers for Medicare & Medicaid Services fee-for-service Medicare claims data. Patients were included if they received an ICD for primary prevention and did not have a documented indication for pacing. MAIN OUTCOMES AND MEASURES: Adjusted risks of 1-year mortality, all-cause readmission, heart failure readmission, and device-related complications within 90 days were estimated with propensity-score matching based on patient, clinician, and hospital factors. RESULTS: Among 32,034 patients, 12,246 (38%) received a single-chamber device and 19,788 (62%) received a dual-chamber device. In a propensity-matched cohort, rates of complications were lower for single-chamber devices (3.51% vs 4.72%; P < .001; risk difference, -1.20 [95% CI, -1.72 to -0.69]), but device type was not significantly associated with 1-year mortality (unadjusted rate, 9.85% vs 9.77%; hazard ratio [HR], 0.99 [95% CI, 0.91 to 1.07]; P = .79), 1-year all-cause hospitalization (unadjusted rate, 43.86% vs 44.83%; HR, 1.00 [95% CI, 0.97-1.04]; P = .82), or hospitalization for heart failure (unadjusted rate, 14.73% vs 15.38%; HR, 1.05 [95% CI, 0.99-1.12]; P = .19). CONCLUSIONS AND RELEVANCE: Among patients receiving an ICD for primary prevention without indications for pacing, the use of a dual-chamber device compared with a single-chamber device was associated with a higher risk of device-related complications and similar 1-year mortality and hospitalization outcomes. Reasons for preferentially using dual-chamber ICDs in this setting remains unclear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Self-citationACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Comparison of Multivariate Matching Methods: Structures, Distances, and Algorithms
Gu, X. S., & Rosenbaum, P. R. (1993) · Journal of Computational and Graphical Statistics · doi:10.1080/10618600.1993.10474623 · Cited by 702 · cited 1×
“This matching interval has been shown to eliminate approximately 90% of the bias in observed confounders.(11) The success of matching was evaluated by examining standardized differences in the observed patient and clinician characteristics between singleand dual-chamber treatment groups.”
Cited by
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
Heart Disease and Stroke Statistics—2020 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Delling, F. N., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000757 · Cited by 9,175
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
Heart disease and stroke statistics-2018 update: a report from the american heart association
Benjamin, E. J., Virani, S. S., Callaway, C. W., Chamberlain, A. M., Chang, A. R., Cheng, S., Chiuve, S. E., Cushman, M., Delling, F. N., Deo, R., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000558 · Cited by 7,146
Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000350 · Cited by 6,596
Self-citationHeart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Heart Disease and Stroke Statistics—2021 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Aparicio, H. J., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Cheng, S., Delling, F. N., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000950 · Cited by 5,784
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator
Burke, M. C., Gold, M. R., Knight, B. P., Barr, C. S., Theuns, D. A. M. J., Boersma, L. V. A., Knops, R. E., Weiss, R., Leon, A. R., Herre, J. M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.02.047 · Cited by 505
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Prutkin, J. M., Reynolds, M. R., Bao, H., Curtis, J. P., Al-Khatib, S. M., Aggarwal, S., & Uslan, D. Z. (2014) · Circulation · doi:10.1161/circulationaha.114.009081 · Cited by 199
“Several studies have used ICD-9 codes and administrative databases, including MedPAR and the National Hospital Discharge Survey, to look at CIED infections.(1,2,4,6,41,42) As noted by other investigators,(2,41) although the practice of coding for complications of CIEDs may be subject to bias, it is more likely that th…”
MethodSelf-citation
Metadata
- Authors
- Peterson, P. N., Varosy, P. D., Heidenreich, P. A., Wang, Y., Dewland, T. A., Curtis, J. P., Go, A. S., Greenlee, R. T., Magid, D. J., Normand, S.-L. T., & Masoudi, F. A.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2013-05-15
- Volume
- 309
- Issue
- 19
- Pages
- 2025
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2088150211
- Cited by
- 132
- References
- 4
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.