The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Effect of Continuous Glucose Monitoring on Hypoglycemia in Older Adults With Type 1 Diabetes: A Randomized Clinical Trial
Open accessAbstract
Importance: Continuous glucose monitoring (CGM) provides real-time assessment of glucose levels and may be beneficial in reducing hypoglycemia in older adults with type 1 diabetes. Objective: To determine whether CGM is effective in reducing hypoglycemia compared with standard blood glucose monitoring (BGM) in older adults with type 1 diabetes. Design, Setting, and Participants: Randomized clinical trial conducted at 22 endocrinology practices in the United States among 203 adults at least 60 years of age with type 1 diabetes. Interventions: Participants were randomly assigned in a 1:1 ratio to use CGM (n = 103) or standard BGM (n = 100). Main Outcomes and Measures: The primary outcome was CGM-measured percentage of time that sensor glucose values were less than 70 mg/dL during 6 months of follow-up. There were 31 prespecified secondary outcomes, including additional CGM metrics for hypoglycemia, hyperglycemia, and glucose control; hemoglobin A1c (HbA1c); and cognition and patient-reported outcomes, with adjustment for multiple comparisons to control for false-discovery rate. Results: Of the 203 participants (median age, 68 [interquartile range {IQR}, 65-71] years; median type 1 diabetes duration, 36 [IQR, 25-48] years; 52% female; 53% insulin pump use; mean HbA1c, 7.5% [SD, 0.9%]), 83% used CGM at least 6 days per week during month 6. Median time with glucose levels less than 70 mg/dL was 5.1% (73 minutes per day) at baseline and 2.7% (39 minutes per day) during follow-up in the CGM group vs 4.7% (68 minutes per day) and 4.9% (70 minutes per day), respectively, in the standard BGM group (adjusted treatment difference, -1.9% (-27 minutes per day); 95% CI, -2.8% to -1.1% [-40 to -16 minutes per day]; P <.001). Of the 31 prespecified secondary end points, there were statistically significant differences for all 9 CGM metrics, 6 of 7 HbA1c outcomes, and none of the 15 cognitive and patient-reported outcomes. Mean HbA1c decreased in the CGM group compared with the standard BGM group (adjusted group difference, -0.3%; 95% CI, -0.4% to -0.1%; P <.001). The most commonly reported adverse events using CGM and standard BGM, respectively, were severe hypoglycemia (1 and 10), fractures (5 and 1), falls (4 and 3), and emergency department visits (6 and 8). Conclusions and Relevance: Among adults aged 60 years or older with type 1 diabetes, continuous glucose monitoring compared with standard blood glucose monitoring resulted in a small but statistically significant improvement in hypoglycemia over 6 months. Further research is needed to understand the long-term clinical benefit. Trial Registration: ClinicalTrials.gov Identifier: NCT03240432.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“There is emerging evidence that CGM is efficacious in reducing hyperglycemia and A1C levels in insulin-treated persons with T2D, including those taking 1 or 2 doses of basal insulin.169–172”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [170]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Emerging evidence suggests benefits of CGM use in insulin-treated persons with T2D170,1074”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [170]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Among secondary outcomes, time spent in range between 70 and 180 mg/dL increased by 8% (95% CI 6.0-11.5)and glycemic variability (%CV) decreased.”
From 13. Older Adults: Standards of Care in Diabetes—2024 (2024) · cites this paper as [39]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Among secondary outcomes, time spent in range between 70 and 180 mg/dL increased by 8% (95% CI 6.0-11.5)and glycemic variability (%CV) decreased.”
From 13. Older Adults: Standards of Care in Diabetes—2025 (2025) · cites this paper as [41]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The use of advanced technologies in older individuals is useful and should not be discontinued or a priori excluded because of the older age (78,274).”
From The management of type 1 diabetes in adults. A consensus report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) (2021) · cites this paper as [78]
Experimental — accuracy not yet measured
The cited source says what the claim attributes to it.
In the citing paper
“Compared to capillary blood glucose monitoring, real-time continuous glucose monitoring has been shown to consistently improve glycaemic metrics in children,14 adolescents15 and adults,16 including older adults,17 with type 1 diabetes.”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [17]
The cited source says what the claim attributes to it.
In the citing paper
“Although most RCTs have not been powered to detect reductions in the rate of severe hypoglycemia, a study in people over the age of 60 with type 1 diabetes (a population at high risk of hypoglycemia) showed significant reductions in both time in the hypoglycemic range and severe hypoglycemic events (162).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [162]
The cited source says what the claim attributes to it.
In the citing paper
“Over 6 months, use of CGM resulted in a small but statistically significant reduction in time spent with hypoglycemia (glucose level <70 mg/dL) compared with standard blood glucose monitoring (adjusted treatment difference À1.9% [À27 min/day]; 95% CI À2.8% to À1.1% [À40 to À16 min/day]; P < 0.001) (38,39).”
From 13. Older Adults: Standards of Care in Diabetes—2024 (2024) · cites this paper as [39]
The cited source says what the claim attributes to it.
In the citing paper
“Over 6 months, use of CGM resulted in a small but statistically significant reduction in time spent with hypoglycemia (glucose level <70 mg/dL) compared with standard blood glucose monitoring (adjusted treatment difference À1.9% [À27 min/day]; 95% CI À2.8% to À1.1% [À40 to À16 min/day]; P < 0.001) (40,41).”
From 13. Older Adults: Standards of Care in Diabetes—2025 (2025) · cites this paper as [41]
The cited source says what the claim attributes to it.
In the citing paper
“Continuous glucose monitoring (CGM) devices have been shown to be effective at improving glycemic management and acceptable to people of all age-groups, including older individuals with type 1 diabetes (44–48) or insulin-requiring type 2 diabetes (49,50).”
From 13. Older Adults: Standards of Care in Diabetes—2026 (2026) · cites this paper as [45]
The cited source says what the claim attributes to it.
In the citing paper
“Continuous glucose monitoring (CGM) devices have been shown to be effective at improving glycemic management and acceptable to people of all age-groups, including older individuals with type 1 diabetes (44–48) or insulin-requiring type 2 diabetes (49,50).”
From 13. Older Adults: Standards of Care in Diabetes—2026 (2026) · cites this paper as [45]
The cited source says what the claim attributes to it.
In the citing paper
“rt-CGM is beneficial in reducing the burden of hypoglycemia in older adults with type 1 diabetes (78) and those with IAH (44).”
In the citing paper
“The primary outcome was met and showed benefit in adults of all ages (38,53,54), including seniors (55-57).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [55]
In the citing paper
“A report in people with type 1 diabetes over the age of 60 years revealed a small but statistically significant decrease in hypoglycemia (125).”
From 6. Glycemic Targets: Standards of Care in Diabetes—2023 (2023) · cites this paper as [125]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“Time with glucose >250 mg/dL, mean (SD), % 10 (6-21) 13 (5-20) 9 (3-15) 13 (8-23) −3.”
Self-citationOn the adaptive control of the false discovery rate in multiple testing with independent statistics
Benjamini, Y., & Hochberg, Y. (2000) · Journal of Educational and Behavioral Statistics · doi:10.3102/10769986025001060 · Cited by 2,015
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Estimates of Location Based on Rank Tests
Hodges, J. L., & Lehmann, E. L. (1963) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177704172 · Cited by 1,276
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185 · cited 4×
“Time with glucose >180 mg/dL, mean (SD), % 37 (16) 38 (17) 34 (14) 39 (16) −5.”
InfluentialSelf-citationLind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Self-citationClarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Fear of hypoglycemia: quantification, validation, and utilization
Cox, D. J., Irvine, A., Gonder-Frederick, L., Nowacek, G., & Butterfield, J. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.617 · Cited by 579
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 496
Flagged first, then by citations
Cited by
Sorted by citations
Items 301–375 of 375
Diabetes mellitus; Diagnosis and treatment in the elderly
Tentolouris, A., Eleftheriadou, I., & Tentolouris, N. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13825-6.00301-0 · Cited by 1
Special Considerations in the Management and Education of Older Persons With Diabetes
Mobley-Bukstein, W., Reece, S. W., & Hebdon, K. (2021) · ADCES in Practice · doi:10.1177/2633559x211015972
Paradigmenwechsel in der Glukosekontrolle: Urin-, Blut-, interstitielle Glukosemessung
Forst, T. M. (2022) · Diabetologie und Stoffwechsel · doi:10.1055/a-1225-8678
Omeara, M., Acuña, J. C. M., & Uribe, A. (2022) · Research Square · doi:10.21203/rs.3.rs-1688540/v1
Kröger, J. (2022) · Die Diabetologie · doi:10.1007/s11428-022-00941-1
Omeara, M., Acuña, J. C. M., & Uribe, A. (2022) · Research Square · doi:10.21203/rs.3.rs-1688540/v2
Significant publications in diabetes pharmacotherapy and technology in 2020
Clements, J. N., Franks, R. B., Isaacs, D. M., Malloy, K., Meade, L. T., Reece, S. W., Reid, D. J., & Ward, E. D. (2023) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2023.2187618
Jacobsen, L. M., Sherr, J. L., Considine, E. G., Chen, A., Peeling, S., Hulsmans, M., Charleer, S., Urazbayeva, M., Tosur, M., ALAMARIE, S. A., et al. (2023) · medRxiv · doi:10.1101/2023.04.15.23288624
Self-citationBehandlung alter Menschen mit Typ-1- oder insulinbehandeltem Typ-2-Diabetes
Meitner-Schellhaas, B., & Haak, T. (2023) · Die Diabetologie · doi:10.1007/s11428-023-01068-7
Van evidencebased medicine naar shared decision-making bij diabetes mellitus
D'Hoore, L., Verroken, C., Matthys, I., & Biesen, W. V. (2023) · Tijdschrift voor Geneeskunde · doi:10.47671/tvg.79.23.024
Perioperatives Management bei alten Menschen mit Diabetes mellitus
Lee-Barkey, Y., & Stratmann, B. (2023) · Die Diabetologie · doi:10.1007/s11428-023-01093-6
Валерьевич, П. В., Александровна, Д. Т., Patrakeeva, E. M., & Taraikovich, A. A. (2023) · Meditsinskiy sovet = Medical Council · doi:10.21518/ms2023-329
Current and Emerging Technologies for the Diagnosis and Treatment of Diabetes Mellitus
Kollman, P., & Burke, E. (2024) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-024-00281-y
A Method to Transform Datasets into Knowledge Graphs
Bravo, M., Barbosa, J. L., & Sánchez-Martínez, L. D. (2024) · Lecture notes in networks and systems · doi:10.1007/978-3-031-47715-7_37
Zhang, D., Yang, Y., Zhang, J., Chen, J., Huang, L., Zhang, L., & Liu, X. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4791181
Kang, E. Y., Shen, C., Huang, X., Kang, C., Lin, T., Hong, W.-H., Yang, L., Wu, W., & Hwang, Y. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.4.047001
Other Considerations in Pump Therapy Management
(2024) · American Diabetes Association eBooks · doi:10.2337/9781580408363.ch07
(2024) · American Diabetes Association eBooks · doi:10.2337/9781580408363.ch05
Diabetes Technology in the Geriatric Population
Pisano, M., Mazzola, N., & Nguyen, N. M. (2024) · Contemporary Endocrinology · doi:10.1007/978-3-031-75352-7_7
李, 康. (2024) · Journal of Clinical Personalized Medicine · doi:10.12677/jcpm.2024.34367
(2022) · American Diabetes Association eBooks · doi:10.2337/9781580407700.ch04
(2022) · American Diabetes Association eBooks · doi:10.2337/9781580407700.ch5
Glycemic Goals and Assessment of Glycemia
(2022) · American Diabetes Association eBooks · doi:10.2337/9781580407700.ch02
Wang, Y., Alexandre‐Heymann, L., Messier, V., Boudreau, V., Bandini, A., Kelly, B., Gravel, A., Gagnon, C., Brazeau, A., & RABASA-LHORET, R. P. R. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.03.009
Eer, A., Hachem, M., Hearn, T., Koye, D. N., Atkinson‐Briggs, S., Jones, J. L., Eades, S., Braat, S., Twigg, S. M., Sinha, A. K., et al. (2025) · Pilot and Feasibility Studies · doi:10.1186/s40814-025-01607-7
Navigating Life with Type 1 Diabetes: Challenges, Innovations, and Daily Resilience
Saini, Y., Mohseen, M., & Sharma, R. (2025) · IntechOpen eBooks · doi:10.5772/intechopen.1009423
Chan, C., & Lau, D. H. H. (2025) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2025.103099
Wiles, J. (2025) · Springer eBooks · doi:10.1007/978-3-031-88835-9_7
Clin‐ STAR Corner: Practice Changing Advances in Diabetes Care
Kahkoska, A. R., Ortega, J., Bilal, A., & Pratley, R. E. (2025) · Journal of the American Geriatrics Society · doi:10.1111/jgs.19595
Self-citationOuslander, J. G. (2025) · Journal of the American Geriatrics Society · doi:10.1111/jgs.70076
Comment on: Editor's Note on Clin‐ STAR Corner: Practice‐Changing Advances in Diabetes Care
Kahkoska, A. R., & Pratley, R. E. (2025) · Journal of the American Geriatrics Society · doi:10.1111/jgs.70077
Self-citationStout, H. K., Planas, L. G., Sewell, H. E., Nadig, A. P., & O’Neal, K. S. (2025) · ADCES in Practice · doi:10.1177/2633559x251366099
Case Studies From India: Management of Diabetes Using Continuous Glucose Monitoring
Gupta, A. K., Krishnan, A. S., Kataria, M., & Jain, N. (2025) · Cureus · doi:10.7759/cureus.93177
Perioperative Medication Considerations for the Older Person
Bui, T., Burfield, T., & Mulqueen, C. (2025) · Springer eBooks · doi:10.1007/978-981-95-0665-1_6
Kahkoska, A. R., Smith, C., Young, L., & Hassmiller‐Lich, K. (2024) · Figshare · doi:10.6084/m9.figshare.26728954
Self-citationKahkoska, A. R., Smith, C., Young, L., & Hassmiller‐Lich, K. (2024) · Figshare · doi:10.6084/m9.figshare.26728957
Self-citationAssociation between therapeutic inertia and future hypoglycemia among patients with type 2 diabetes
Chen, H., Chung, L. P., Chen, Y., Schleyer, T., DeMeritt, K., Halm, E. A., Chow, L. S., Luo, L., & Wolfson, J. A. (2026) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2026.100305
Batir, D. M., Boev, M., Gurău, G., Matei, M. N., Nechita, A., & Maftei, N.-M. (2026) · IntechOpen eBooks · doi:10.5772/intechopen.1014475
Bilal, A., Horton, W. B., Kovatchev, B. P., Casu, A., Pratley, R., Kanapka, L., & Beck, R. W. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261432166
Self-citationNakayama, H., Hashinaga, T., Yamada, K., Wada, N., Inada, C., Iwata, S., Tokubuchi, I., Yoshinobu, S., Tanaka, Y., Nagayama, A., et al. (2026) · Diabetology International · doi:10.1007/s13340-026-00897-3
Coșovanu, E. O., Szilagyi, A., Szilágyi, A., Coșovanu, E. T., Corneanu, L. E., Sîngeap, M. S., Tamba, B.-I., Hriţcu, L., & Petriș, O. R. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15093194
Why glycemic control remains suboptimal in type 1 diabetes in the era of advanced technologies?
Joubert, M. (2026) · Diabetes & Metabolism · doi:10.1016/j.diabet.2026.101763
Hermanns, N., Ehrmann, D., Heinemann, L., Roos, T., Kulzer, B., Resl, M., Mader, J. K., Brandt, D., Trümpy, C., Koch, L. M., et al. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261444045
Deng, C., Fan, W., Xie, Y., Tang, X., Jiang, H., Niu, X., Yan, D., Su, H., Kuang, H., Tian, L., et al. (2026) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70833
Ishola, A. F., Eaton, A. A., Kim, S. K., Basina, M., Beilman, G. J., & Bellin, M. D. (2026) · Clinical Transplantation · doi:10.1111/ctr.70573
Domínguez-Navarro, A., Lee, M., Chen, Y., Batten, J., Mensah, B. A., & Nam, S. (2026) · Geriatric Nursing · doi:10.1016/j.gerinurse.2026.104075 · Cited by 1
Khan, M. S., Valabhji, J., Sattar, N. A., Murphy, H. R., Mehta, F., Kar, P., Hambling, C. E., Khunti, K. K., Tan, G. D., & Holman, N. (2026) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70929
Zhang, S.-H., Zhang, J.-P., Song, L.-L., Wu, L.-L., Li, Z.-Q., He, Y.-F., Deng, R.-F., Ma, W.-L., Zhang, C., Zhang, B., et al. (2026) · World Journal of Diabetes · doi:10.4239/wjd.119604
Kinetics of Hypoglycemia in Diabetes Patients Informs Development of New Modes of Glucagon TherapyPreprint
Li, J., Byrne, C., Liang, J., Lee, S., Lyhne, M. K., Meng, A., Ling, S. R., Li, S., Lopes, A., Khosravi, P., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.05.729994
Nowakowska, M. K., Jerzyńska, O., Kałachurska, M., Rozek, M., Kowalewska-Kurek, A., Lisowska, A., Nowak, B., Sierant, M., Gural, M., & Guy, C. E. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.5407
Calhoun, P. M., Liggins, R., Li, Z., Riddell, M. C., Bergenstal, R. M., Simonson, G. D., Shah, V. N., Peers, S. H., Sherr, J. L., & Beck, R. W. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261461810
Self-citationCao, T., Fang, M., Wallace, A. S., Malek, N. D., Valint, A., Wang, D., Echouffo-Tcheugui, J. B., Zeger, S. L., & Selvin, E. (2026) · Clinical Chemistry · doi:10.1093/clinchem/hvag067
Dovč, K., Mianowska, B., Boettcher, C., Cardona‐Hernandez, R., Berge, T. V. D., Davis, E. A., Kosteria, I., Marigliano, M., Rami-Merhar, B. M., Scharf, M., et al. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261463841
When headache signals hypoglycemia: Clinical recognition and management
Burroughs, B. T. (2026) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2026.07.005
Su, H., Ni, J., Cai, J., Zhu, W., Wang, Y., Zhou, J., Lu, J., & Ma, X. (2026) · Diabetes Obesity and Metabolism · doi:10.1111/dom.71143
Advanced Technology in Diabetes: Sensors and Pumps
Forlenza, G. P. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-11985-9.00023-8
INSIGHT: Ingest and Standardize Glucose Harmonization Tool
Ehlert, B., -, K. S., Katarya, D., Wu, Y., Wang, T., & Snyder, M. P. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261467778
Taneri, P. E., Bongaerts, B. W. C., Shokraee, K., Thinakaran, K., Wolf, M. V., Metzendorf, M., Roglić, G., Franco, J. V. A., & Guo, Y. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016263
Pazmiño, S., Schmid, S., Steenackers, N., Sandig, R., van Laar, A., Weiskorn, J., Meulemeester, J. D., Mader, J. K., Charleer, S., Wosch, F. J., et al. (2026) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2026.101806
Beyond Glycemia: Entering the Era of Hard Outcomes for Continuous Glucose Monitoring
Alkabbani, W., CROMER, S. J., & Patorno, E. (2026) · Diabetes Care · doi:10.2337/dci26-0084
Digital Health Technologies and Hypoglycaemia
Villard, O., & Renard, É. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_24
Yang, T., Cai, J., Ni, J., Lu, J., & Zhou, J. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261485635
Efect of Continuios Glucose Monitoring Management Type 1 Diabetes: Meta-AnalysisPreprint
Ferreira, I. I. D. C., Costa, B. H. S., Dantas, E. D., Batista, M. M. D. L., Batista, A. F. D. M. B., de Araújo, L. F., & Batista, P. S. D. S. (2026) · Research Square · doi:10.21203/rs.3.rs-10539077/v1
Mkuu, R. S., Rahman, P., Rivero‐Mendoza, D., Donahoo, W. T., Shenkman, E. A., Ojo, D. P., & Lamas, M. R. (2026) · Journal of Diabetes Research · doi:10.1155/jdr/8650831
Holt, R. I. G., DeVries, J. H., Fischl, A. H., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, É., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06833-z
Self-citationYoo, J. H., Kim, S., Park, Y. J., Park, S., Chung, C. H., Kim, J. H., Kwak, S. H., & Kim, G. (2026) · Diabetes Care · doi:10.2337/dc26-1039
Knowledge and Attitudes Regarding Continuous Glucose Monitors as Predictors of Current Use
Gallegos, S. P., Zohn, J. H., Hutchins, A. M., Derksen, L. A., & Benton, M. J. (2026) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106261483745
Oktavian, P., Wungu, C. D. K., Amin, I. M., & Mudjanarko, S. W. (2026) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgag344
Benefits and Challenges of Diabetes Technology in the Older Adult
DeMarsilis, A. J., & Toschi, E. (2026) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2026.08.010
(2026) · ADA Clinical Compendia · doi:10.2337/db20261-33
Czupryniak, L., Mysliwiec, M., Gellert, R., Jankowski, P., Mastalerz–Migas, A., Strojek, K., Walczak, M., & Targowski, T. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.10.010
Diabetes mellitus im Alter – Praxisempfehlung der DDG
Zeyfang, A., Lee-Barkey, Y.-H., & Bahrmann, A. (2026) · Diabetologie und Stoffwechsel · doi:10.1055/a-2866-0305
Gupta, M., Dey, A. K., Goklani, R., MODI, R., & Saraogi, H. (2026) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_31_26
Assis, A. N., Siqueira, M. E. S., Ribeiro, V. S. O., Moreno, A. M., Viana, L. S., Gomes, D. G., & Siqueira, R. D. A. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113624
Metadata
- Authors
- Pratley, R. E., Kanapka, L. G., Rickels, M. R., Ahmann, A., Aleppo, G., Beck, R., Bhargava, A., Bode, B. W., Carlson, A., Chaytor, N. S., Fox, D. S., Goland, R., Hirsch, I. B., Kruger, D., Kudva, Y. C., Levy, C., McGill, J. B., Peters, A., Philipson, L., Philis-Tsimikas, A., Pop-Busui, R., Shah, V. N., Thompson, M., Vendrame, F., Verdejo, A., Weinstock, R. S., Young, L., Miller, K. M., & for the Wireless Innovation for Seniors With Diabetes Mellitus (WISDM) Study Group
- Affiliations
- AdventHealth Orlando (US)
- Jaeb Center for Health Research (US)
- University of Pennsylvania Health System (US)
- Oregon Health & Science University (US)
- Northwestern University (US)
- Iowa Diabetes and Endocrinology Research Center (US)
- Atlanta Diabetes Associates (US)
- Park Nicollet Health Services (US)
- Washington State University Spokane (US)
- University of Southern California (US)
- Columbia University (US)
- University of Washington (US)
- Henry Ford Health (US)
- Mayo Clinic (US)
- Icahn School of Medicine at Mount Sinai (US)
- Washington University in St. Louis (US)
- University of Chicago (US)
- Scripps Whittier Diabetes Institute, La Jolla, California
- University of Michigan, Ann Arbor
- University of Colorado Anschutz (US)
- University of Massachusetts Chan Medical School (US)
- University of Miami (US)
- SUNY Upstate Medical University (US)
- University of North Carolina at Chapel Hill (US)
- Corresponding author
- Pratley, Richard E.
- ORCID
- Pratley, Richard E.
- Kanapka, Lauren G.
- Rickels, Michael R.
- Ahmann, Andrew
- Aleppo, Grazia
- Beck, Roy
- Bhargava, Anuj
- Bode, Bruce W.
- Carlson, Anders
- Chaytor, Naomi S.
- Fox, D. Steven
- Hirsch, Irl B.
- Kruger, Davida
- Kudva, Yogish C.
- Levy, Carol
- McGill, Janet B.
- Peters, Anne
- Philipson, Louis
- Shah, Viral N.
- Thompson, Michael
- Vendrame, Francesco
- Verdejo, Alandra
- Weinstock, Ruth S.
- Young, Laura
- Miller, Kellee M.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2020-06-16
- Volume
- 323
- Issue
- 23
- Pages
- 2397
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- PMC
- PMC7298607
- OpenAlex
- W3034989043
- Semantic Scholar
- 1c097e3947a1ab456a4aec132a408f1d6419a62b
- Cited by
- 375
- References
- 28
- Citations by year
- 2026: 55 · 2025: 63 · 2024: 72 · 2023: 61 · 2022: 67 · 2021: 48 · 2020: 9
- FWCI
- 34.88
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- JAMA (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eli Lilly and Company
- AstraZeneca
- Sanofi
- Gilead Sciences
- McGill University
- Insulet Corporation
- MannKind Corporation
- Dexcom
- Mylan
- Jaeb Center for Health Research
- Novo Nordisk
- National Institutes of Health (UL1TR001422, UL1TR001878)
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK020541, P30DK020595, P30DK111022)
- National Center for Research Resources
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- continuous glucose monitoring, hypoglycemia, type 1 diabetes, older adults, blood glucose monitoring, hyperglycemia, glycemic control, HbA1c, cognitive function, patient-reported outcomes, insulin pump therapy, hypoglycemia awareness, hypoglycemia treatment, hypoglycemia prevention
- MeSH terms
- Patient Reported Outcome Measures, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hyperglycemia, Hypoglycemia, Hypoglycemic Agents, Male, Middle Aged, Blood Glucose Self-Monitoring, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review