Noninvasive Glucose Monitoring: Comprehensive Clinical Results
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
CONTEXT: Intensive diabetes management using frequent blood glucose measurements to guide therapy has been shown to significantly improve short- and long-term outcomes. Development of a device that makes possible frequent, automatic, painless, and accurate measurements of glucose would facilitate intensive management. OBJECTIVE: To determine the accuracy of the GlucoWatch automatic glucose biographer (Cygnus Inc) compared with that of serial blood glucose measurements. DESIGN: Multicenter comparative study of the GlucoWatch biographer and the HemoCue blood glucose analyzer (Aktiebolaget Leo) performed between August 29 and October 17, 1998. Participants wore up to 2 biographers during the 15-hour study session and performed 2 fingersticks per hour for comparative blood glucose measurements. The biographers were calibrated with a single HemoCue measurement after a 3-hour warm-up period. Diet and insulin were manipulated to produce a broad glycemic range during the study. SETTING: Controlled clinical environment at 2 diabetes centers and 3 contract research organizations in the United States. PARTICIPANTS: A total of 92 subjects (mean [SD] age, 42.1 [15.1] years; 59.8% women) with type 1 or 2 diabetes requiring treatment with insulin. MAIN OUTCOME MEASURES: Mean error, mean absolute error, correlation, slope, and intercept using Deming regression, and clinical significance of differences between biographer readings and blood glucose measurements using the Clarke error grid. RESULTS: Results showed close tracking of blood glucose over a range of 2.2 to 22.2 mmol/L (40-400 mg/dL) for up to 12 hours using a single point calibration. The biographer readings lagged behind serial blood glucose values by a mean of 18 minutes. An analysis of 2167 data pairs shows a linear relationship (r = 0.88; slope = 1.03; intercept = -0.33 mmol/L [-6 mg/dL]) between biographer readings and serial glucose measurements. The mean absolute error between the 2 measurements was 15.6% (mean error [SD], -0.07 [1.82] mmol/L [-1 [33] mg/dL]), and 96.8% of the data fell in the therapeutically relevant regions of the error grid analysis. CONCLUSION: These results demonstrate close agreement between GlucoWatch biographer readings and blood glucose measurements using repeated fingerstick blood samples. The automatic, frequent, and noninvasive measurements obtained with the biographer provides more information about glucose levels than the current standard of care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“One of the first commercial wearable sensing devices, a wrist-worn glucose monitor, used iontophoresis to extract ISF for analysis77.”
From End-to-end design of wearable sensors (2022) · cites this paper as [77]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
DRAIZE, J. H., WOODARD, G., & CALVERY, H. O. (1944) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)08751-8 · Cited by 2,602
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
Tamada, J. A., Bohannon, N. J. V., & Potts, R. O. (1995) · Nature Medicine · doi:10.1038/nm1195-1198 · Cited by 182
Self-citationReverse Iontophoresis: Noninvasive Glucose Monitoring in Vivo in Humans
Rao, G. S., Guy, R. H., Glikfeld, P., LaCourse, W. R., Leung, L., Tamada, J. A., Potts, R. O., & Azimi, N. (1995) · Pharmaceutical Research · doi:10.1023/a:1016271301814 · Cited by 138
Self-citationMeyerhoff, C., Bischof, F., Sternberg, F., Zier, H., & Pfeiffer, E. F. (1992) · Diabetologia · doi:10.1007/bf02221686 · Cited by 126
Validation of home blood glucose meters with respect to clinical and analytical approaches
Brunner, G. A., Ellmerer, M., Sendlhofer, G., Wutte, A., Trajanoski, Z., Schaupp, L., Quehenberger, F., Wach, P., Krejs, G. J., & Pieber, T. R. (1998) · Diabetes Care · doi:10.2337/diacare.21.4.585 · Cited by 119
Cited by
Items 201–299 of 299
Sacks, D. B. (2012) · Tietz Textbook of Clinical Chemistry and Molecular Diagnostics · doi:10.1016/b978-1-4160-6164-9.00046-9 · Cited by 7
Point-of-Care Testing for Diabetes
Blake, D. R., & Nathan, D. M. (2002) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/01.poc.0000023103.92641.7f · Cited by 7
New Developments in Home Glucose Monitoring: Minimizing the Pain
Gabbay, R. A., Phd, M., & Gabbay, R. A. (2015) · Cited by 7
Iontophoresis Enhanced Transdermal Drug Delivery
Ning, X., Seeni, R. Z., & Xu, C. (2019) · Wiley eBooks · doi:10.1002/9783527814633.ch12 · Cited by 7
Iontophoresis: Clinical Applications and Future Challenges
Abla, N., Kalia, Y. N., Guy, R. H., & Naik, A. (2005) · CRC Press eBooks · doi:10.1201/9781420039207.pt3 · Cited by 7
Noninvasive evaluation of glucose concentration in the human blood based on electrocardiograms
Pulavskyi, A. A., Krivenko, S., & Krivenko, S. A. (2015) · IEEE International Conference on Electronics and Nanotechnology (ELNANO) · doi:10.1109/elnano.2015.7146890 · Cited by 7
Srivastava, A., Chowdhury, M. K., Sharma, S., & Sharma, N. (2016) · British Biotechnology Journal · doi:10.9734/bbj/2016/24861 · Cited by 7
Halimi, S., Wion-Barbot, N., Lambert, S., & Benhamou, P. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(03)72771-2 · Cited by 7
Analysis: A Noninvasive Ocular Glucose Sensor
March, W. F. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/152091501300209561 · Cited by 7
Chen, C.-S., Wang, K.-K., Jan, M.-Y., Hsu, W.-C., Li, S.-P., Wang, Y. L., & Bau, J.-G. (2008) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2007.03.011 · Cited by 7
Tanojo, H., & Maïbach, H. I. (2001) · Current Problems in Dermatology · doi:10.1016/s1040-0486(01)70006-3 · Cited by 7
Li, A., Li, X., Xu, Y., Wu, C., Geng, Z., Zhang, J., Wang, X., Li, Y., Li, H., Guo, X., et al. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01402-8 · Cited by 6
Preventive Systems for the Late Complications of Diabetes
Ładyżyński, P., Wojcicki, J. M., & Foltyński, P. (2011) · Journal of Applied Biomedicine · doi:10.1016/s0208-5216(11)70007-9 · Cited by 6
Wearable and Fexible Sensor Sheets toward Periodic Health Monitoring
Takei, K. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2_7 · Cited by 6
Seo, T., Jeon, W., & Choi, Y. (2023) · Chemosensors · doi:10.3390/chemosensors11090485 · Cited by 6
Mesure en continu de la glycémie : différents sites, différentes ambitions
Choleau, C., & Reach, G. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(03)72769-4 · Cited by 6
The Insulin Pump: Making life with diabetes easier.
Olohan, K., & Zappitelli, D. (2003) · AJN American Journal of Nursing · doi:10.1097/00000446-200304000-00020 · Cited by 6
Poonguzhali, S., & Chakravarthi, R. (2019) · International Conference on Power and Embedded Drive Control (ICPEDC) · doi:10.1109/icpedc47771.2019.9036551 · Cited by 6
Mo, X., Wen, Z., Zhao, S., Mo, J., Liu, F., Chen, M., Zhan, C., Zhang, M., Wang, J., Wen, S., et al. (2022) · Materials & Design · doi:10.1016/j.matdes.2022.110812 · Cited by 6
Giannola, L. I., Caro, V. D., & Sutera, F. M. (2015) · Advances in delivery science and technology · doi:10.1007/978-1-4899-7558-4_5 · Cited by 6
Technology advances in glucose monitoring
Pickup, J. C. (2002) · Pediatric Diabetes · doi:10.1034/j.1399-5448.2002.30301.x · Cited by 6
Transdermal Microfluidic Continuous Monitoring Systems
Cunningham, D. D. (2009) · Wiley eBooks · doi:10.1002/9780470567319.ch7 · Cited by 5
Advances in continuous in vivo glucose monitoring
Leitao, E., Kaushal, K., Gill, A., & Vadgama, P. M. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.19.s5.7.x · Cited by 5
Continuous Subcutaneous Glucose Monitoring in Children With Type 1 Diabetes
Zung, A., & Zadik, Z. (2002) · PEDIATRICS · doi:10.1542/peds.109.2.347b · Cited by 5
Guillet, J.-F. (2017) · theses.fr (ABES) · doi:10.70675/c697fdfaz7ef7z481az88aaz6f494a16769b · Cited by 5
Remote photonic sensing of glucose concentration via analysis of time varied speckle patterns
Ozana, N. N., Talman, R., Shemer, A., Schwartz, A., Polani, S., Califa, R., Beiderman, Y., Ruiz-Rivas, J., & Garc, J. (2018) · Advanced Materials Letters · doi:10.5185/amlett.2018.2054 · Cited by 5
Continuous Subcutaneous Glucose Monitoring in Children With Type 1 Diabetes
Zung, A., Zadik, Z., & Chase, H. P. (2002) · PEDIATRICS · doi:10.1542/peds.109.2.347-a · Cited by 5
Chen, J., Yu, K., Zhuang, S., & Zhang, D. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1342744 · Cited by 4
Quality of care for the woman with diabetes at pregnancy
de Leiva, A., Corcoy, R., de Leiva-Pérez, A., & Brugués, E. (2018) · CRC Press eBooks · doi:10.1201/9781315382104-58 · Cited by 4
Application of an enteric coat increases the resistance to gastric juices for swallowable biosensors
Murakami, Y., Zhang, Y., Takeuchi, T., Noda, T., Noda, K., & Kuroda, A. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.07.064 · Cited by 4
Hydrogel-based electrochemical sensor for non-invasive and continuous glucose monitoring
Park, H., Lee, J., Kim, D.-C., Koh, Y. G., & Cha, J. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2268332 · Cited by 4
Iontophoresis: Clinical Applications and Future Challenges
Abla, N., Naik, A., Guy, R. H., & Kalia, Y. N. (2005) · CRC Press eBooks · doi:10.1201/9781420039207-21 · Cited by 4
Ferrari, G. L. (2008) · Americanae (AECID Library) · Cited by 4
New therapies for type 1 diabetes mellitus.
Jayarag, K., Davis, E. D., & McNeill, D. (2001) · Europe PMC (PubMed Central) · Cited by 4
KAWANAKA, K., UETSUJI, Y., Tsuchiya, K., & NAKAMACHI, E. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.810478 · Cited by 4
Nonlinear Dielectric Spectroscopy of Biological Systems: Principles ans Applications
Kell, D. B., Woodward, A. M., Davies, E. A., Todd, R. W., Evans, M. F., & Rowland, J. J. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/1-4020-2704-4_31 · Cited by 3
100 Years of insulin: A chemical engineering perspective
Bequette, B. W. (2023) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-022-1308-8 · Cited by 3
Non-Invasive Monitoring of Diabetes
Khalil, O. S. (2007) · Springer eBooks · doi:10.1007/0-387-33015-1_7 · Cited by 3
Nguyen, L. (2014) · OPUS - Open Publications of UTS Scholars (University of Technology Sydney) · Cited by 3
Glucose Monitoring by Reverse Iontophoresis
Tierney, M. J. (2000) · Springer eBooks · doi:10.1007/978-1-4615-1231-8_21 · Cited by 3
Giri, T. K., Chakrabarty, S., & Ghosh, B. (2018) · Current Pharmaceutical Analysis · doi:10.2174/1573412914666180910115059 · Cited by 3
Chen, Q., Kersten, B. R., Li, J., Wu, C. C., Jagasia, P., & Ewing, A. G. (2001) · Electroanalysis · doi:10.1002/1521-4109(200101)13:1<61::aid-elan61>3.0.co;2-h · Cited by 3
Koschwanez, H. E. (2009) · DukeSpace (Duke University) · Cited by 2
Laboratory Techniques for Recognition of Endocrine Disorders
Klee, G. G. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-0324-5.00006-7 · Cited by 2
Analysis: The "Hop, Skip, and Jump": On Exercise with a Continuous Glucose Sensor Device
WEINZIMER, S. A. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041705938 · Cited by 2
Modelling Net Energy of Selected Commercial Diets Fed to Domestic Adult Cats
Asaro, N. J. (2018) · The Atrium (University of Guelph) · Cited by 2
Development of a semi-quantitative tear film based method for public screening of diabetes mellitus
Takkar, B., Mukherjee, S., Chauhan, R. C., & Venkatesh, P. (2019) · Medical Hypotheses · doi:10.1016/j.mehy.2019.02.043 · Cited by 2
Garg, S. K. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.2499 · Cited by 2
Self-citationPoint-of-Care Biosensors for Glucose Sensing
Vyas, T., Choudhary, S., Kumar, N., & Joshi, A. (2022) · Springer eBooks · doi:10.1007/978-981-19-5141-1_5 · Cited by 2
Understanding the Routes of Administration
Gupta, D., Gupta, S. V., & Yang, N. (2018) · Springer eBooks · doi:10.1007/978-3-319-50909-9_12-1 · Cited by 2
Srour, M. (2017) · theses.fr (ABES) · doi:10.70675/a72de4eez38ddz4309zb7e5zc055b75b8f9c · Cited by 2
Feasibility of non-invasive optical blood-glucose detection using overtone circular dichroismPreprint
Hokr, B. H., Tovar, C., Meng, Z., Petrov, G. I., & Yakovlev, V. V. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1601.06143 · Cited by 2
QC Test for Noninvasive Glucose Monitoring System
Wu, C. C., Kersten, B. R., Chen, Q., Li, J., & Jagasia, P. (2001) · Electroanalysis · doi:10.1002/1521-4109(200102)13:2<117::aid-elan117>3.0.co;2-n · Cited by 2
Rapid Methods of Microbiological Analysis: An Update
Fung, D. Y. C. (2000) · Springer eBooks · doi:10.1007/978-1-4615-1231-8_22 · Cited by 2
Impact of New Technologies in Medicine: A Global Theme Issue
Mark, D. H., & Glass, R. M. (1999) · JAMA · doi:10.1001/jama.282.19.1875 · Cited by 2
Lu, D., Yang, C., Chen, L., Cao, C., Xia, W., Li, G., & Wen, D. (2024) · Electroanalysis · doi:10.1002/elan.202300385 · Cited by 1
On Non-Invasive Glucose Measurements
Aroutiounian, V. M. (2022) · Journal of Contemporary Physics (Armenian Academy of Sciences) · doi:10.1134/s1068337222040041 · Cited by 1
Point-of-Care Testing in the Management of Diabetes Mellitus
Winter, W. E. (2002) · CRC Press eBooks · doi:10.1201/b14092-11 · Cited by 1
Study of the effect of sugar concentration on the characteristic impedance of a magnetic coil
Yakubov, V. P., Makhmanazarov, R. M., Klokov, A., Сергеевич, З. А., Zavyalova, K., & Mironichev, A. S. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/516/1/012056 · Cited by 1
Noninvasive, Intrusive, and Nonintrusive Measurements
Sanei, S., Jarchi, D., & Constantinides, A. G. (2020) · Wiley eBooks · doi:10.1002/9781119390060.ch6 · Cited by 1
Daugherty, K. A. (2000) · Journal of the American Pharmaceutical Association (1996) · doi:10.1016/s1086-5802(16)31118-4 · Cited by 1
Introduction & Literature Review
Kochhar, J. S., Tan, J., Kwang, Y. C., & Kang, L. (2019) · Springer eBooks · doi:10.1007/978-3-030-15444-8_1 · Cited by 1
Wearable Non-Invasive System for Gestational Diabetes Mellitus Monitoring
Prabakar, S., Manikandan, K., Arunprasath, S., Bavithra, M., & Rajasekar, M. (2026) · International Conference on Artificial Intelligence and Machine Learning Applications Theme: Healthcare and Internet of Things (AIMLA) · doi:10.1109/aimla67915.2026.11522353 · Cited by 1
Consensus guidelines 2000 ISPAD
Regan, F. M. (2002) · Practical Diabetes · doi:10.1002/pdi.343 · Cited by 1
Ching, C. T., Camilleri, I. G., & Connolly, P. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmd.2004.1689553 · Cited by 1
Design and assessment of blood glucose regulation for type I diabetes
Lee, K. (2012) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/5106 · Cited by 1
The Role of Frequent Glucose Monitoring in Intensive Diabetes Management
(2001) · The Science of Diabetes Self-Management and Care · doi:10.1177/014572170102700212 · Cited by 1
Review: In Vivo Chemical Sensing—Opportunities and Challenges
Arnold, M. A. (2000) · e-biomed The Journal of Regenerative Medicine · doi:10.1089/152489000414615 · Cited by 1
Measurement with a chemical sensor and a dialysis probe supported by a null method
Otsuka, K., Sumino, T., Miyagi, M., Togawa, T., & Mitsubayashi, K. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.02.017 · Cited by 1
Iontophoresis: Applications in Drug Delivery and Noninvasive Monitoring
Guy, R. H., & Delgado-Charro, M. B. (2002) · CRC Press eBooks · doi:10.1201/9780203909683.ch5 · Cited by 1
A better mousetrap: What's new in blood glucose monitoring?
Cox, M. A. (2002) · Journal of Pediatric Health Care · doi:10.1016/s0891-5245(02)00069-x · Cited by 1
ALZA Transdermal Drug Delivery Technologies
Padmanabhan, R., Phipps, J. B., Cormier, M., Tamada, J. A., Audett, J., Gyory, J. R., & Daddona, P. E. (2008) · CRC Press eBooks · doi:10.3109/9781420045260-22 · Cited by 1
Self-citationNear infrared fluorescent sensors and their use in vivo
Cooley, N. P. (2017) · MOspace Institutional Repository (University of Missouri) · doi:10.32469/10355/61913
Davey, R. J. (2010) · UWA Profiles and Research Repository (UWA)
Development of a continuous glucose monitor based on microfluidics
Moon, B. (2012) · University of Groningen research database (University of Groningen / Centre for Information Technology)
Messsysteme für das kontinuierliche Glukosemonitoring – Vergleich der verschiedenen Systeme
Siegmund, T., Kolassa, R., & Thomas, A. (2014) · Diabetes aktuell · doi:10.1055/s-0034-1372222
Mesotten, D., & den Berghe, G. V. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1367-1.00018-5
Quality of care for the woman with diabetes in pregnancy
de Leiva, A., Corcoy, R., & Brugués, E. (2008) · Series in maternal-fetal medicine · doi:10.3109/9781439802007.053
A non-invasive continuous glucose monitoring method based on the Bergman minimal model
Li, A., Zhao, L., Wu, C., Geng, Z., Yang, L., & Tang, F. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-025-03422-x
Xu, Y., Li, A., Wu, C., Geng, Z., Zhang, J., Wang, X., Li, Y., Li, H., Guo, X., & Tang, F. (2021) · doi:10.2196/preprints.32333
Development of a Persistent, Accessible and Non-invasive Glucose Monitoring Device
Biradar, V., Jana, A. K., Gadgay, B., Mohanty, S. C., Verma, A., & Patil, V. (2023) · International Conference on Computational Intelligence and Communication Networks (CICN) · doi:10.1109/cicn59264.2023.10402198
Advancements in Assistive Technology for Menstrual Period Management
Yamunarani, T., Santhoshkumar, S., Baskaran, D., Karthikeswaran, D., Duraisamy, B., & SanthaVinothini, A. G. (2026) · International Conference on Next Generation Electronics (NELEX) · doi:10.1109/nelex69209.2026.11590816
An Improved Blood Glucose Measurement Using Near-Infrared Light
Luong, D. T., Duc, N. M., Van, N. T., & Ha, N. T. (2022) · Advances in intelligent systems and computing · doi:10.1007/978-981-19-3590-9_48
Layer-by-Layer Technology and Its Implications in the Field of Glucose Nanobiosensors
Sasi, S. P. (2014) · Advances in chemical and materials engineering book series · doi:10.4018/978-1-4666-6363-3.ch019
Об не-инвазивных измерениях глюкозы
Арутюнян, В. М. (2022) · Proceedings of NAS RA Physics · doi:10.54503/0002-3035-2022-57.4-595
Invasive and Noninvasive Means of Diabetes Self-Management
Deiss, D., Hartmann, R., & Kordonouri, O. (2005) · KARGER eBooks · doi:10.1159/000085799
Hirsch, I. B. (2001) · Clinical Diabetes · doi:10.2337/diaclin.19.1.2
Open- and Closed-Loop Insulin Delivery Systems and Glucose Sensors
Pickup, J. C. (2003) · Humana Press eBooks · doi:10.1007/978-1-59259-310-1_12
Untari, I., Prasojo, I., Enikmawati, A., Sayono, S., & Kusumawati, Y. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6337702
Puech-Bret, N., & Hanaire, H. P. (2007) · Annales d Endocrinologie · doi:10.1016/s0003-4266(07)80006-0
Blood Glucose Sensors in Digital Health-Era
Murakami, Y. (2012) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.132.427
Non-Invasive Blood Glucose Meter
Sheth, M., Jadhav, M. M., & Deshmukh, S. (2021) · Journal of Science and Technology · doi:10.46243/jst.2021.v6.i04.pp67-74
NAKAMACHI, E., KAWANAKA, K., UETSUJI, Y., Tsuchiya, K., & Morita, Y. (2010) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.76.290
Development of portable health monitoring system for automatic self-blood glucose measurement
Kim, H., Mizuno, Y., NAKAMACHI, E., & Morita, Y. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.841522
非侵襲的血糖測定の現状と将来展望(<特集>非侵襲検査の最前線)
Noda, M. (2006) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/ikakikaigaku.76.12_903
Kini, D. P. (2002) · Memorial University Research Repository (Memorial University)
Three Generations of Transdermal Drug Delivery
Prausnitz, M. R. (2010)
A Brief Analysis of Wearable Electronic Medical Devices
Du, Y. (2020) · Advances in intelligent systems and computing · doi:10.1007/978-981-33-4572-0_60
Potts, R. O., Tamada, J. A., & Tierney, M. J. (2002) · Pest Management Science · doi:10.1002/dmrr.210.abs
Self-citation
Metadata
- Authors
- Tamada, J. A., Garg, S., Jovanovic, L., Pitzer, K. R., Fermi, S., Potts, R. O., & and the Cygnus Research Team
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1999-11-17
- Volume
- 282
- Issue
- 19
- Pages
- 1839
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2088032108
- Cited by
- 282
- References
- 18
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.