A Clinical Decision Support System for Prevention of Venous Thromboembolism: Effect on Physician Behavior
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
CONTEXT: Computer-based clinical decision support systems (CDSSs) have been promoted for their potential to improve quality of health care. However, given the limited range of clinical settings in which they have been tested, such systems must be evaluated rigorously before widespread introduction into clinical practice. OBJECTIVE: To determine whether presentation of venous thromboembolism prophylaxis guidelines using a CDSS increases the proportion of appropriate clinical practice decisions made. DESIGN: Time-series study conducted between December 1997 and July 1999. SETTING: Orthopedic surgery department of a teaching hospital in Paris, France. PARTICIPANTS: A total of 1971 patients who underwent orthopedic surgery. INTERVENTION: A CDSS designed to provide immediate information pertaining to venous thromboembolism prevention among surgical patients was integrated into daily medical practice during three 10-week intervention periods, alternated with four 10-week control periods, with a 4-week washout between each period. MAIN OUTCOME MEASURE: Proportion of appropriate prescriptions ordered for anticoagulation, according to preestablished clinical guidelines, during intervention vs control periods. RESULTS: Physicians complied with guidelines in 82.8% (95% confidence interval [CI], 77.6%-87.1%) of cases during control periods and in 94.9% (95% CI, 92.5%-96.6%) of cases during intervention periods. During each intervention period, the appropriateness of prescription increased significantly (P<.001). Each time the CDSS was removed, physician practice reverted to that observed before initiation of the intervention. The relative risk of inappropriate practice decisions during control periods vs intervention periods was 3.8 (95% CI, 2.7-5.4). CONCLUSIONS: In our study, implementation of clinical guidelines for venous thromboembolism prophylaxis through a CDSS used routinely in an orthopedic surgery department and integrated into the hospital information system changed physician behavior and improved compliance with guidelines. JAMA. 2000;283:2816-2821
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davis, D. A. (1995) · JAMA · doi:10.1001/jama.1995.03530090032018 · Cited by 1,763
Hunt, D. L., Haynes, R. B., Hanna, S. E., & Smith, K. (1998) · JAMA · doi:10.1001/jama.280.15.1339 · Cited by 1,669
Generalized linear mixed models a pseudo-likelihood approach
Wolfinger, R., & O'connell, M. (1993) · Journal of Statistical Computation and Simulation · doi:10.1080/00949659308811554 · Cited by 1,271 · cited 1×
“Model parameters were estimated using the iteratively reweighted restricted likelihood method and fixed effects were tested with the Fisher exact test (SAS GLIMIX macro).(14) Mean probability of appropriateness of prescription according to study period was then generated by taking the exponential transformation of the…”
MethodWalker, P. M. (1992) · Journal of Vascular Surgery · doi:10.1016/0741-5214(92)90773-2 · Cited by 828
Shea, S., DuMouchel, W., & Bahamonde, L. (1996) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1996.97084513 · Cited by 542
Improving Drug Prescribing in Primary Care: A Critical Analysis of the Experimental Literature
SOUMERAI, S. B., McLAUGHLIN, T. J., & AVORN, J. (2005) · The Milbank Quarterly · doi:10.1111/j.1468-0009.2005.00435.x · Cited by 327 · cited 1×
“The rate of reversion of compliance to guidelines to baseline values during each control period, even after 15 months, showed that a CDSS cannot be considered an educational tool or that education alone is unable to sustain substantial changes in physician practice as has been suggested previously.(25,26) Our study ha…”
BackgroundMant, J., & Hicks, N. (1995) · BMJ · doi:10.1136/bmj.311.7008.793 · Cited by 303 · cited 1×
“Statistical analyses require an adequate number of outcomes for the results to be meaningful.(29,32) Conversely, the use of process measures can identify specific shortcomings (eg, proportion of inappropriate prescriptions) and point toward what needs to be changed.”
BackgroundComputerized Prescribing: Building the Electronic Infrastructure for Better Medication Usage
Schiff, G. D., & Rucker, T. D. (1998) · JAMA · doi:10.1001/jama.279.13.1024 · Cited by 247 · cited 1×
“In particular, it has been suggested that physicians have difficulties processing complex information(2) and will improve their prescription practices in response to electronically delivered recommendations.(3) However, given their rapid rate of development and the limited range of clinical settings in which they have…”
BackgroundThe clinical value of computerized information services. A review of 98 randomized clinical trials
Balas, E. A. (1996) · Archives of Family Medicine · doi:10.1001/archfami.5.5.271 · Cited by 190 · cited 1×
“15-18 A significant effect on physician behavior was observed despite a high baseline compliance to guidelines (84.1”
BackgroundInfluentialAnderson, F. A. (1994) · Archives of Internal Medicine · doi:10.1001/archinte.1994.00420060103011 · Cited by 156
Randolph, A. G., Haynes, R. B., Wyatt, J. C., Cook, D. J., & Guyatt, G. H. (1999) · JAMA · doi:10.1001/jama.282.1.67 · Cited by 136
Schriger, D. L. (1997) · JAMA · doi:10.1001/jama.278.19.1585 · Cited by 114
Davies, H. T. O., & Crombie, I. K. (1995) · BMJ · doi:10.1136/bmj.311.7008.766 · Cited by 99
Utilization of Venous Thromboembolism Prophylaxis in a Medical-Surgical ICU
Ryskamp, R. P., & Trottier, S. J. (1998) · CHEST Journal · doi:10.1378/chest.113.1.162 · Cited by 46 · cited 1×
“In 2 recent studies performed in surgical and medical-surgicalpatients, 86%and85%, respectively, received venous thromboembolism prophylaxis before any intervention.(10,19) The CDSS was able to maintain a sustained effect of guidelines for a relatively long period.”
BackgroundIndicators of clinical performance
McKee, M. (1997) · BMJ · doi:10.1136/bmj.315.7101.142 · Cited by 44
McNally, E., de Lacey, G., Lovell, P., & Welch, T. (1995) · BMJ · doi:10.1136/bmj.310.6980.640 · Cited by 28
Computerized reminder for prophylaxis of deep vein thrombosis in surgical patients
Patterson, R. (2012) · PubMed Central · doi:10.26053/0h-frgc-exg0 · Cited by 17
Durieux, P., & Ravaud, P. (1997) · International Journal for Quality in Health Care · doi:10.1093/intqhc/9.3.215 · Cited by 9 · cited 2×
“Clinical guidelines for venous thromboembolism prophylaxis were developed at Assistance Publique–Hôpitaux de Paris.(12,13) These local guidelines for general surgery, urologic surgery, gynecologic surgery, and orthopedic surgery were created by local hospital experts.”
BackgroundSelf-citation(1995) · PubMed
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Heit, J. A., Clagett, G. P., Pineo, G. F., Colwell, C. W., Anderson, F. A., & Wheeler, H. B. (2001) · Chest · doi:10.1378/chest.119.1_suppl.132s · Cited by 4,373
Automation bias: a systematic review of frequency, effect mediators, and mitigators
Goddard, K., Roudsari, A., & Wyatt, J. C. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000089 · Cited by 1,162
Electronic Alerts to Prevent Venous Thromboembolism among Hospitalized Patients
Kucher, N., Koo, S., Quiroz, R., Cooper, J. M., Paterno, M. D., Soukonnikov, B., & Goldhaber, S. Z. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa041533 · Cited by 942
Rotter, T., Kinsman, L., James, E. L., Machotta, A., Gothe, H., Willis, J., Snow, P., & Kugler, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006632.pub2 · Cited by 800
Antoniadi, A. M., Du, Y., Guendouz, Y., Wei, L., Mazo, C., Becker, B. A., & Mooney, C. (2021) · Applied Sciences · doi:10.3390/app11115088 · Cited by 629
“…[35], oncology [36] and specifically, breast cancer [37], chronic obstructive pulmonary disease [38], the prevention of venous thromboembolism [39], the prediction of chronic kidney disease [40] and Alzheimer’s disease [41], for diabetes care [42], and risk-level prediction of heart disease…”
Background
Metadata
- Authors
- Durieux, P., Nizard, R., Ravaud, P., Mounier, N., & Lepage, E.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2000-06-07
- Volume
- 283
- Issue
- 21
- Pages
- 2816
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2059798728
- Cited by
- 240
- References
- 19
- FWCI
- 24.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.