Whole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
CONTEXT: Deciding on the appropriate therapy for patients with malignant diseases mandates accurate tumor staging with whole-body coverage. Magnetic resonance imaging (MRI) and a combined modality including positron emission tomography (PET) and computed tomography (CT) provide whole-body tumor staging in a single session. OBJECTIVE: To determine the staging accuracies of both whole-body PET/CT and whole-body MRI for different malignant diseases. DESIGN, SETTING, AND PATIENTS: Prospective, blinded, investigator-initiated study of 98 patients (mean age, 58 years; range, 27-94 years) with various oncological diseases who underwent back-to-back whole-body glucose analog [18F]-fluorodeoxyglucose-PET/CT and whole-body MRI for tumor staging. The study was conducted at a university hospital from December 2001 through October 2002 and had a mean follow-up of 273 days (range, 75-515 days). The images were evaluated by 2 different, blinded reader teams. The diagnostic accuracies of the 2 imaging procedures were compared. MAIN OUTCOME MEASURES: Correct classification of the primary tumor, regional lymph nodes, and distant metastasis (overall TNM stage) using whole-body PET/CT and whole-body MRI. Secondary outcome measures were accurate assessment of T-stage, N-stage, and M-stage by the 2 imaging procedures. RESULTS: Of 98 patients, the overall TNM stage was correctly determined in 75 with PET/CT (77%; 95% confidence interval [CI], 67%-85%) and in 53 with MRI (54%; 95% CI, 44%-64%) (P<.001). Compared with MRI, PET/CT had a direct impact on patient management in 12 patients. Results from MRI changed the therapy regimen in 2 patients compared with PET/CT. Separate assessment of T-stage (with pathological verification) in 46 patients revealed PET/CT to be accurate in 37 (80%; 95% CI, 66%-91%) and MRI to be accurate in 24 (52%; 95% CI, 37%-67%) (P<.001). Of 98 patients, N-stage was correctly determined in 91 patients with PET/CT (93%; 95% CI, 86%-97%) and in 77 patients with MRI (79%; 95% CI, 69%-86%) (P =.001). Both imaging procedures showed a similar performance in detecting distant metastases. CONCLUSIONS: The feasibility and diagnostic accuracy of the whole-body staging strategies of PET/CT and MRI are established. Superior performance in overall TNM staging suggests the use of [18F]-fluorodeoxyglucose-PET/CT as a possible first-line modality for whole-body tumor staging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Preoperative Staging of Non–Small-Cell Lung Cancer with Positron-Emission Tomography
Pieterman, R. M., van Putten, J. W. G., Meuzelaar, J. J., Mooyaart, E. L., Vaalburg, W., Koëter, G. H., Fidler, V., Pruim, J., & Groen, H. J. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007273430404 · Cited by 1,111
Gould, M. K., Maclean, C. C., Kuschner, W. G., Rydzak, C. E., & Owens, D. K. (2001) · JAMA · doi:10.1001/jama.285.7.914 · Cited by 1,094
Noninvasive Staging of Non-small Cell Lung Cancer*
Toloza, E. M., Harpole, L., & McCrory, D. C. (2003) · Chest · doi:10.1378/chest.123.1_suppl.137s · Cited by 745
Kinkel, K., Lu, Y., Both, M., Warren, R. S., & Thoeni, R. F. (2002) · Radiology · doi:10.1148/radiol.2243011362 · Cited by 621
Non–Small Cell Lung Cancer: Dual-Modality PET/CT in Preoperative Staging
Antoch, G., Stattaus, J., Nemat, A. T., Marnitz, S., Beyer, T., Kuehl, H., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2003) · Radiology · doi:10.1148/radiol.2292021598 · Cited by 540
Self-citationFocal pulmonary abnormalities: evaluation with F-18 fluorodeoxyglucose PET scanning.
Patz, E. F., Lowe, V. J., Hoffman, J. M., Paine, S. S., Burrowes, P., Coleman, R. E., & Goodman, P. C. (1993) · Radiology · doi:10.1148/radiology.188.2.8327702 · Cited by 511
Pastorino, U., Bellomi, M., Landoni, C., De Fiori, E., Arnaldi, P., Picchio, M., Pelosi, G., Boyle, P., & Fazio, F. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14188-8 · Cited by 452
Daldrup-Link, H. E., Franzius, C., Link, T. M., Laukamp, D., Sciuk, J., Jürgens, H., Schober, O., & Rummeny, E. J. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.1.1770229 · Cited by 444
Upper abdominal lymph nodes: criteria for normal size determined with CT.
Dorfman, R. E., Alpern, M. B., Gross, B. H., & Sandler, M. A. (1991) · Radiology · doi:10.1148/radiology.180.2.2068292 · Cited by 348
PET Diagnostic Accuracy: Improvement with In-Line PET-CT System: Initial Results
Hany, T. F., Steinert, H. C., Goerres, G. W., Buck, A., & von Schulthess, G. K. (2002) · Radiology · doi:10.1148/radiol.2252011568 · Cited by 323
Beyer, T., Antoch, G., Blodgett, T., Freudenberg, L. F., Akhurst, T., & Mueller, S. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1097-6 · Cited by 298
Self-citationSemelka, R. C., Martin, D. R., Balci, C., & Lance, T. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1057 · Cited by 274
Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients.
Osman, M., Cohade, C., Nakamoto, Y., Marshall, L. T., Leal, J. P., & Wahl, R. L. (2003) · PubMed · Cited by 252
Flamen, P., Stroobants, S., Van Cutsem, E., Dupont, P., Bormans, G., De Vadder, N., Penninckx, F., Van Hoe, L., & Mortelmans, L. (1999) · Journal of Clinical Oncology · doi:10.1200/jco.1999.17.3.894 · Cited by 242
Franzius, C., Daldrup-Link, H. E., Wagner-Bohn, A., Sciuk, J., Heindel, W. L., Jürgens, H., & Schober, O. (2002) · Annals of Oncology · doi:10.1093/annonc/mdf012 · Cited by 203
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-78-6-990_3 · Cited by 201
Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans.
Antoch, G., Freudenberg, L. S., Egelhof, T., Stattaus, J., Jentzen, W., Debatin, J. F., & Bockisch, A. (2002) · PubMed · Cited by 201
Self-citationHollinshead, W. H. (1954) · Harper & Row eBooks · Cited by 195
Evaluation of head and neck cancer with 18F-FDG PET: a comparison with conventional methods
Kresnik, E., Mikosch, P., Gallowitsch, H., Kogler, D., Wieser, S., Heinisch, M., Unterweger, O., Raunik, W., Kumnig, G., Gomez, I., et al. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100554 · Cited by 161
Dizendorf, E., Hany, T. F., Buck, A., von Schulthess, G. K., & Burger, C. (2003) · PubMed · Cited by 158
Initial experience with oral contrast in PET/CT: phantom and clinical studies.
Cohade, C., Osman, M., Nakamoto, Y., Marshall, L. T., Links, J. M., Fishman, E. K., & Wahl, R. L. (2003) · PubMed · Cited by 152
Dual-modality PET/CT tomography for clinical oncology.
Beyer, T., Townsend, D. W., & Blodgett, T. M. (2002) · PubMed · Cited by 137
Whole-Body Positron Emission Tomography—CT: Optimized CT Using Oral and IV Contrast Materials
Antoch, G., Freudenberg, L. S., Stattaus, J., Jentzen, W., Müeller, S., Debatin, J. F., & Bockisch, A. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.6.1791555 · Cited by 117
Self-citationFDG-PET as a "metabolic biopsy" tool in non-lung lesions with indeterminate biopsy
Beggs, A. D., Hain, S. F., Curran, K. M., & O'Doherty, M. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0736-7 · Cited by 109
Comparison of helical CT and MR imaging in detecting and staging small pancreatic adenocarcinoma
Irie, H., Honda, H., Kaneko, K., Kuroiwa, T., Yoshimitsu, K., & Masuda, K. (1997) · Abdominal Imaging · doi:10.1007/s002619900226 · Cited by 101
Harisinghani, M. G., Saini, S., Slater, G. J., Schnall, M. D., & Rifkin, M. D. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070124 · Cited by 79
Comparison of MR and PET imaging for the evaluation of liver metastases
Yang, M., Martín, D. R., Karabulut, N., & Frick, M. P. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10265 · Cited by 64
Martinelli, M. (2000) · Clinical Positron Imaging · doi:10.1016/s1095-0397(00)00073-x · Cited by 46
Bockisch, A., Brandt-Mainz, K., Görges, R., Muller, S., Stattaus, J., & Antoch, G. (2003) · Acta Medica Austriaca · doi:10.1046/j.1563-2571.2003.02045.x · Cited by 41
Self-citationImaging of lung cancer with CT, MRT and PET
Haberkorn, U., & Schoenberg, S. O. (2001) · Lung Cancer · doi:10.1016/s0169-5002(01)00369-5 · Cited by 29
Role of magnetic resonance imaging in the staging of gastrointestinal neoplasms
Ferraris, R., del Piano, A., & Galli, J. J. (2001) · Seminars in Surgical Oncology · doi:10.1002/ssu.1025 · Cited by 5
Cited by
American Thyroid Association Guidelines for Management of Patients with Anaplastic Thyroid Cancer
Smallridge, R. C., Ain, K. B., Asa, S. L., Bible, K. C., Brierley, J. D., Burman, K. D., Kebebew, E., Lee, N. Y., Nikiforov, Y. E., Rosenthal, M. S., et al. (2012) · Thyroid · doi:10.1089/thy.2012.0302 · Cited by 935
Bible, K. C., Kebebew, E., Brierley, J., Brito, J. P., Cabanillas, M. E., Clark, T. J., Di Cristofano, A., Foote, R., Giordano, T., Kasperbauer, J., et al. (2021) · Thyroid · doi:10.1089/thy.2020.0944 · Cited by 730
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Bone Imaging in Metastatic Breast Cancer
Hamaoka, T., Madewell, J. E., Podoloff, D. A., Hortobagyi, G. N., & Ueno, N. T. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.08.181 · Cited by 656
In vivo imaging of glucose uptake and metabolism in tumors
Walker-Samuel, S., Ramasawmy, R., Torrealdea, F., Rega, M., Rajkumar, V., Johnson, S. P., Richardson, S., Gonçalves, M., Parkes, H. G., Årstad, E., et al. (2013) · Nature Medicine · doi:10.1038/nm.3252 · Cited by 479
“FDG-PET is generally considered to be more expensive than MRI 29,30 , so glucoCEST could also offer considerable financial savings (although estimated costs for the two modalities can vary substantially from country to country 31 ).”
Metadata
- Authors
- Antoch, G.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2003-12-24
- Volume
- 290
- Issue
- 24
- Pages
- 3199
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2151669991
- Cited by
- 551
- References
- 32
- FWCI
- 22.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.