Abstract
CONTEXT: A thin, cobalt-chromium stent eluting the antiproliferative agent everolimus from a nonadhesive, durable fluoropolymer has shown promise in preliminary studies in improving clinical and angiographic outcomes in patients with coronary artery disease. OBJECTIVE: To evaluate the safety and efficacy of an everolimus-eluting stent compared with a widely used paclitaxel-eluting stent. DESIGN, SETTING, AND PATIENTS: The SPIRIT III trial, a prospective, randomized, single-blind, controlled trial enrolling patients at 65 academic and community-based US institutions between June 22, 2005, and March 15, 2006. Patients were 1002 men and women undergoing percutaneous coronary intervention in lesions 28 mm or less in length and with reference vessel diameter between 2.5 and 3.75 mm. Angiographic follow-up was prespecified at 8 months in 564 patients and completed in 436 patients. Clinical follow-up was performed at 1, 6, 9, and 12 months. INTERVENTIONS: Patients were randomized 2:1 to receive the everolimus-eluting stent (n = 669) or the paclitaxel-eluting stent (n = 333). MAIN OUTCOME MEASURES: The primary end point was noninferiority or superiority of angiographic in-segment late loss. The major secondary end point was noninferiority assessment of target vessel failure events (cardiac death, myocardial infarction, or target vessel revascularization) at 9 months. An additional secondary end point was evaluation of major adverse cardiac events (cardiac death, myocardial infarction, or target lesion revascularization) at 9 and 12 months. RESULTS: Angiographic in-segment late loss was significantly less in the everolimus-eluting stent group compared with the paclitaxel group (mean, 0.14 [SD, 0.41] mm vs 0.28 [SD, 0.48] mm; difference, -0.14 [95% CI, -0.23 to -0.05]; P < or = .004). The everolimus stent was noninferior to the paclitaxel stent for target vessel failure at 9 months (7.2% vs 9.0%, respectively; difference, -1.9% [95% CI, -5.6% to 1.8%]; relative risk, 0.79 [95% CI, 0.51 to 1.23]; P < .001). The everolimus stent compared with the paclitaxel stent resulted in significant reductions in composite major adverse cardiac events both at 9 months (4.6% vs 8.1%; relative risk, 0.56 [95% CI, 0.34 to 0.94]; P = .03) and at 1 year (6.0% vs 10.3%; relative risk, 0.58 [95% CI, 0.37 to 0.90]; P = .02), due to fewer myocardial infarctions and target lesion revascularization procedures. CONCLUSIONS: In this large-scale, prospective randomized trial, an everolimus-eluting stent compared with a paclitaxel-eluting stent resulted in reduced angiographic late loss, noninferior rates of target vessel failure, and fewer major adverse cardiac events during 1 year of follow-up. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00180479.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Self-citationMintz, G. S., Nissen, S. E., Anderson, W. D., Bailey, S. R., Erbel, R., Fitzgerald, P. J., Pinto, F. J., Rosenfield, K., Siegel, R. J., Tuzcu, E. M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01175-5 · Cited by 2,185
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Self-citationFinn, A. V., Joner, M., Nakazawa, G., Kolodgie, F., Newell, J., John, M. C., Gold, H. K., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.107.693739 · Cited by 1,277
Eisen, H. J., Tuzcu, E. M., Dorent, R., Kobashigawa, J., Mancini, D., Valantine-von Kaeppler, H. A., Starling, R. C., Sørensen, K., Hummel, M., Lind, J. M., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022171 · Cited by 1,198
Stone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., et al. (2005) · JAMA · doi:10.1001/jama.294.10.1215 · Cited by 765
Self-citationA Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Spaulding, C., Daemen, J., Boersma, E., Cutlip, D. E., & Serruys, P. W. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066633 · Cited by 704
Cited by
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
Palmerini, T., Biondi-Zoccai, G., Riva, D. D., Stettler, C., Sangiorgi, D., D'Ascenzo, F., Kimura, T., Briguori, C., Sabatè, M., Kim, H.-S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60324-9 · Cited by 959
Self-citationEverolimus-Eluting versus Paclitaxel-Eluting Stents in Coronary Artery Disease
Stone, G. W., Rizvi, A., Newman, W., Mastali, K., Wang, J. C., Caputo, R., Doostzadeh, J., Cao, S., Simonton, C. A., Sudhir, K., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0910496 · Cited by 902
Self-citationUrban, P., Mehran, R., Colleran, R., Angiolillo, D. J., Byrne, R. A., Capodanno, D., Cuisset, T., Cutlip, D., Eerdmans, P., Eikelboom, J., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.040167 · Cited by 823
Kedhi, E., Joesoef, K. S., McFadden, E., Wassing, J., van Mieghem, C., Goedhart, D., & Smits, P. C. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62127-9 · Cited by 687
Comparison of Zotarolimus-Eluting and Everolimus-Eluting Coronary Stents
Serruys, P. W., Silber, S., Garg, S., van Geuns, R. J., Richardt, G., Buszman, P. E., Kelbæk, H., van Boven, A. J., Hofma, S. H., Linke, A., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1004130 · Cited by 670
Windecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease
Ellis, S. G., Kereiakes, D. J., Metzger, D. C., Caputo, R. P., Rizik, D. G., Teirstein, P. S., Litt, M. R., Kini, A., Kabour, A., Marx, S. O., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509038 · Cited by 630
Self-citationUrban, P., Mehran, R., Colleran, R., Angiolillo, D. J., Byrne, R. A., Capodanno, D., Cuisset, T., Cutlip, D., Eerdmans, P., Eikelboom, J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz372 · Cited by 621
Bangalore, S., Kumar, S., Fusaro, M., Amoroso, N., Attubato, M. J., Feit, F., Bhatt, D. L., & Slater, J. (2012) · Circulation · doi:10.1161/circulationaha.112.097014 · Cited by 574
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Paclitaxel-Eluting Stents versus Bare-Metal Stents in Acute Myocardial Infarction
Stone, G. W., Lansky, A. J., Pocock, S. J., Gersh, B. J., Dangas, G., Wong, S. C., Witzenbichler, B., Guagliumi, G., Peruga, J. Z., Brodie, B. R., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810116 · Cited by 443
Self-citationSarno, G., Lagerqvist, B., Fröbert, O., Nilsson, J., Olivecrona, G., Omerovic, E., Saleh, N., Venetzanos, D., & James, S. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr479 · Cited by 378
Acute Coronary Syndromes: Diagnosis and Management, Part II
Kumar, A., & Cannon, C. P. (2009) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)60674-5 · Cited by 336
Stettler, C., Allemann, S., Wandel, S., Kastrati, A., Morice, M. C., Schomig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., Lezo, J. S. D., et al. (2008) · BMJ · doi:10.1136/bmj.a1331 · Cited by 320
“Rapid technological developments led to novel, second generation drug eluting stents using different antiproliferative substances, absorbable polymers used as drug carriers, and fully bioabsorbable stent systems. Although the short term results for effectiveness of these new generation devices are encouraging,”
BackgroundSelf-citationCoronary stents: historical development, current status and future directions
Iqbal, J., Gunn, J., & Serruys, P. W. (2013) · British Medical Bulletin · doi:10.1093/bmb/ldt009 · Cited by 319
Smits, P. C., Hofma, S., Togni, M., Vázquez, N., Valdés, M., Voudris, V., Slagboom, T., Goy, J.-J., Vuillomenet, A., Serra, A., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61852-2 · Cited by 293
Kandzari, D. E., Mauri, L., Koolen, J. J., Massaro, J. M., Doros, G., Garcia-Garcia, H. M., Bennett, J., Roguin, A., Gharib, E. G., Cutlip, D. E., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32249-3 · Cited by 279
Bosiers, M., Scheinert, D., Peeters, P., Torsello, G., Zeller, T., Deloose, K., Schmidt, A., Tessarek, J., Vinck, E., & Schwartz, L. B. (2012) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.07.099 · Cited by 277
Pilgrim, T., Heg, D., Roffi, M., Tüller, D., Muller, O., Vuilliomenet, A., Cook, S., Weilenmann, D., Kaiser, C., Jamshidi, P., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61038-2 · Cited by 267
Drug-Eluting versus Bare-Metal Stents in Large Coronary Arteries
Kaiser, C., Galatius, S., Erne, P., Eberli, F., Alber, H., Rickli, H., Pedrazzini, G., Hornig, B., Bertel, O., Bonetti, P., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1009406 · Cited by 267
Bioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease
Gao, R., Yang, Y., Han, Y., Huo, Y., Chen, J., Yu, B., Su, X., Li, L., Kuo, H.-C., Ying, S.-W., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.09.054 · Cited by 252
Self-citationByrne, R. A., Kastrati, A., Kufner, S., Massberg, S., Birkmeier, K. A., Laugwitz, K.-L., Schulz, S., Pache, J., Fusaro, M., Seyfarth, M., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp352 · Cited by 220
Munk, P. S., Staal, E. M., Butt, N., Isaksen, K., & Larsen, A. I. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.08.021 · Cited by 161
The Evolution of Coronary Stents: A Brief Review
Simard, T., Hibbert, B., Ramirez, F. D., Froeschl, M., Chen, Y.-X., & O'Brien, E. R. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2013.09.012 · Cited by 160
“Similarly, the SPIRIT III trial compared the Xience-V and Taxus Express demonstrating improvements in late lumen loss and lower MACE rates largely because of fewer MIs.(80) The subsequent SecondGeneration Everolimus-Eluting and Paclitaxel-Eluting Stents in Real-Life Practice (COMPARE) trial demonstrated improved stent…”
Allocco, D. J., Cannon, L. A., Britt, A., Heil, J. E., Nersesov, A., Wehrenberg, S., Dawkins, K. D., & Kereiakes, D. J. (2010) · Trials · doi:10.1186/1745-6215-11-1 · Cited by 159
Metadata
- Authors
- Stone, G. W.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2008-04-23
- Volume
- 299
- Issue
- 16
- Pages
- 1903
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2120754408
- Cited by
- 582
- References
- 21
- FWCI
- 70.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.