Effectiveness of Standard vs Enhanced Self-measurement of Blood Pressure Paired With a Connected Smartphone Application: A Randomized Clinical Trial
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Importance: Self-measured blood pressure (SMBP) with commercially available connected smartphone applications may help patients effectively use SMBP measurements. Objective: To determine if enhanced SMBP paired with a connected smartphone application was superior to standard SMBP for blood pressure (BP) reduction or patient satisfaction. Design, Setting, and Participants: This randomized clinical trial was conducted among 23 health systems participating in PCORnet, the National Patient-Centered Clinical Research Network, and included patients who reported having uncontrolled BP at their last clinic visit, a desire to lower their BP, and a smartphone. Enrollment and randomization occurred from August 3, 2019, to December 31, 2020, which was followed by 6 months of follow-up for each patient. Analysis commenced shortly thereafter. Interventions: Eligible participants were randomly assigned to enhanced SMBP using a device that paired with a connected smartphone application (enhanced) or a standard device (standard). Participants received their device in the mail, along with web-based educational materials and phone-based support as needed. No clinician engagement was undertaken, and the study provided no special mechanisms for delivering measurements to clinicians for use in BP management. Main Outcomes and Measures: Reduction in systolic BP, defined as the difference between clinic BP at baseline and the most recent clinic BP extracted from electronic health records at 6 months. Results: Enrolled participants (1051 enhanced [50.0%] vs 1050 standard [50.0%]; 1191 women [56.7%]) were mostly middle-aged or older (mean [SD] age, 58 [13] years), nearly a third were Black or Hispanic (645 [31%]), and most were relatively comfortable using technology (mean [SD], 4.1 [1.1] of 5). The mean (SD) change in systolic BP from baseline to 6 months was −10.8 (18) mm Hg vs −10.6 (18) mm Hg (enhanced vs standard: adjusted difference, −0.19 mm Hg; 95% CI, −1.83 to 1.44;P = .81). Secondary outcomes were mostly null, except for documented attainment of BP control to lower than 140/<90 mm Hg, which occurred in 32% enhanced vs 29% standard groups (odds ratio, 1.15; 95% CI, 1.01-1.34). Most participants were very likely to recommend their SMBP device to a friend (70% vs 69%). Conclusions and Relevance: This randomized clinical trial found that enhanced SMBP paired with a smartphone application is not superior to standard SMBP for BP reduction or patient satisfaction. Trial Registration: ClinicalTrials.gov Identifier:NCT03796689
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
2020 International Society of Hypertension global hypertension practice guidelines
Unger, T., Borghi, C., Charchar, F., Khan, N. A., Poulter, N. R., Prabhakaran, D., Ramirez, A., Schlaich, M., Stergiou, G. S., Tomaszewski, M., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002453 · Cited by 1,283
Tuckson, R. V., Edmunds, M., & Hodgkins, M. L. (2017) · New England Journal of Medicine · doi:10.1056/nejmsr1503323 · Cited by 907
Tucker, K. L., Sheppard, J. P., Stevens, R., Bosworth, H. B., Bove, A., Bray, E. P., Earle, K., George, J., Godwin, M., Green, B. B., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002389 · Cited by 658
Margolis, K. L., Asche, S. E., Bergdall, A. R., Dehmer, S. P., Groen, S. E., Kadrmas, H. M., Kerby, T. J., Klotzle, K. J., Maciosek, M. V., Michels, R. D., et al. (2013) · JAMA · doi:10.1001/jama.2013.6549 · Cited by 591
McManus, R. J., Mant, J., Haque, M. S., Bray, E. P., Bryan, S., Greenfield, S. M., Jones, M. I., Jowett, S., Little, P., Penaloza, C., et al. (2014) · JAMA · doi:10.1001/jama.2014.10057 · Cited by 408
Shimbo, D., Artinian, N. T., Basile, J. N., Krakoff, L. R., Margolis, K. L., Rakotz, M. K., Wozniak, G., & On behalf of the American Heart Association and the American Medical Association (2020) · Circulation · doi:10.1161/cir.0000000000000803 · Cited by 389
Self-citationUhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-3-201308060-00008 · Cited by 368
Bray, E. P., Holder, R., Mant, J., & McManus, R. J. (2010) · Annals of Medicine · doi:10.3109/07853890.2010.489567 · Cited by 245
Cited by
Writing Committee Members*, Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., et al. (2025) · Hypertension · doi:10.1161/hyp.0000000000000249 · Cited by 310
Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., Bress, A. P., et al. (2025) · JACC · doi:10.1016/j.jacc.2025.05.007 · Cited by 280
Self-citationTang, M., Nakamoto, C. H., Stern, A. D., Zubizarreta, J. R., Marcondes, F. O., Uscher-Pines, L., Schwamm, L. H., & Mehrotra, A. (2023) · Annals of Internal Medicine · doi:10.7326/m23-1182 · Cited by 30
Motta-Yanac, E., Riley, V., Ellis, N. J., Mankoo, A., & Gidlow, C. J. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2024.105755 · Cited by 5
Metadata
- Authors
- Pletcher, M. J., Fontil, V., Modrow, M. F., Carton, T., Chamberlain, A. M., Todd, J., O’Brien, E. C., Sheer, A., Vittinghoff, E., Park, S., Orozco, J., Lin, F., Maeztu, C., Wozniak, G., Rakotz, M., Shay, C. M., & Cooper-DeHoff, R. M.
- Venue
- JAMA Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2022-10-01
- Volume
- 182
- Issue
- 10
- Pages
- 1025
- ISSN
- 2168-6106 (ISSN-L)
- OpenAlex
- W4293735888
- Cited by
- 42
- References
- 14
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effectiveness of Standard vs Enhanced Self-measurement of Blood Pressure Paired With a Connected Smartphone Application: A Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jamainternmed.2022.3355
- The paper
- Pletcher, M. J., Fontil, V., Modrow, M. F., Carton, T., Chamberlain, A. M., Todd, J., O’Brien, E. C., Sheer, A., Vittinghoff, E., Park, S., Orozco, J., Lin, F., Maeztu, C., Wozniak, G., Rakotz, M., Shay, C. M., & Cooper-DeHoff, R. M. (2022). Effectiveness of Standard vs Enhanced Self-measurement of Blood Pressure Paired With a Connected Smartphone Application: A Randomized Clinical Trial. JAMA Internal Medicine. https://doi.org/10.1001/jamainternmed.2022.3355
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.