Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.

Self-Measured Blood Pressure Monitoring in the Management of Hypertension: A Systematic Review and Meta-analysis

Uhlig, Katrin, Patel, Kamal, Ip, Stanley, Kitsios, Georgios D., Balk, Ethan M. · 2013 · Annals of Internal Medicine

Abstract

BACKGROUND: Clinical guidelines recommend that adults with hypertension self-monitor their blood pressure (BP). PURPOSE: To summarize evidence about the effectiveness of self-measured blood pressure (SMBP) monitoring in adults with hypertension. DATA SOURCES: MEDLINE (inception to 8 February 2013) and Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews (fourth quarter 2012). STUDY SELECTION: 52 prospective comparative studies of SMBP monitoring with or without additional support versus usual care or an alternative SMBP monitoring intervention in persons with hypertension. DATA EXTRACTION: Data on population, interventions, BP, other outcomes, and study method were extracted. Random-effects model meta-analyses were done. DATA SYNTHESIS: For SMBP monitoring alone versus usual care (26 comparisons), moderate-strength evidence supports a lower BP with SMBP monitoring at 6 months (summary net difference, -3.9 mm Hg and -2.4 mm Hg for systolic BP and diastolic BP) but not at 12 months. For SMBP monitoring plus additional support versus usual care (25 comparisons), high-strength evidence supports a lower BP with use of SMBP monitoring, ranging from -3.4 to -8.9 mm Hg for systolic BP and from -1.9 to -4.4 mm Hg for diastolic BP, at 12 months in good-quality studies. For SMBP monitoring plus additional support versus SMBP monitoring alone or with less intense additional support (13 comparisons), low-strength evidence fails to support a difference. Across all comparisons, evidence for clinical outcomes is insufficient. For other surrogate or intermediate outcomes, low-strength evidence fails to show differences. LIMITATION: Clinical heterogeneity in protocols for SMBP monitoring, additional support, BP targets, and management; follow-up of 1 year or less in most studies, with sparse clinical outcome data. CONCLUSION: Self-measured BP monitoring with or without additional support lowers BP compared with usual care, but the BP effect beyond 12 months and long-term benefits remain uncertain. Additional support enhances the BP-lowering effect. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.

Overview

Integrity signals

Registry

Crossref · 10.7326/0003-4819-159-3-201308060-00008

Cites

73 of 73 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 74 references

Research works printed but not linked: 8

  1. Cheltsova A, 2010, Hypertension, 56, 109
  2. Johnson AL, 1978, Can Med Assoc J, 119, 1034
  3. Magid DJ, 2011, Am J Manag Care, 17, 96
  4. Midanik LT, 1991, Public Health Rep, 106, 85
  5. 10.1016/s0895-7061(04)00867-2 · DOI
  6. Shea S, 2007, Trans Am Clin Climatol Assoc, 118, 289
  7. 10.1001/jama.291.8.955 · DOI · Paper page
  8. Glynn LG, 2010, Cochrane Database Syst Rev, CD005182

Cited by

See all 386

Metadata

Authors
Uhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M.
Affiliations
Lahey Hospital and Medical Center (US)
Venue
Annals of Internal Medicine
Published
2013-08-06
Volume
159
Issue
3
Pages
185-194
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2063641811
Cited by
368
References
74
Citations by year
2026: 10 · 2025: 24 · 2024: 32 · 2023: 23 · 2022: 29 · 2021: 31 · 2020: 47 · 2019: 35 · 2018: 28 · 2017: 35 · 2016: 28 · 2015: 28 · 2014: 14 · 2013: 4
FWCI
4.19
Type
journal article
Language
en
Open access
closed
Licence
www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
Locations
  • Annals of Internal Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Annals of Internal Medicine
Funders
U.S. Public Health Service (HHSA 290 2007 10055-I 1)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
  • Health Sciences › Nursing › Nutrition and Dietetics › Sodium Intake and Health
Keywords
self-measured blood pressure, hypertension, blood pressure control, patient support, usual care, systolic blood pressure, diastolic blood pressure
MeSH terms
Adult, Blood Pressure, Counseling, Humans, Hypertension, Patient Education as Topic, Social Support, Blood Pressure Monitoring, Ambulatory, Comparative Effectiveness Research

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-Measured Blood Pressure Monitoring in the Management of Hypertension: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.7326/0003-4819-159-3-201308060-00008
The paper
Uhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M. (2013). Self-Measured Blood Pressure Monitoring in the Management of Hypertension: A Systematic Review and Meta-analysis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-159-3-201308060-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.