The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.
Self-Measured Blood Pressure Monitoring in the Management of Hypertension: A Systematic Review and Meta-analysis
Abstract
BACKGROUND: Clinical guidelines recommend that adults with hypertension self-monitor their blood pressure (BP). PURPOSE: To summarize evidence about the effectiveness of self-measured blood pressure (SMBP) monitoring in adults with hypertension. DATA SOURCES: MEDLINE (inception to 8 February 2013) and Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews (fourth quarter 2012). STUDY SELECTION: 52 prospective comparative studies of SMBP monitoring with or without additional support versus usual care or an alternative SMBP monitoring intervention in persons with hypertension. DATA EXTRACTION: Data on population, interventions, BP, other outcomes, and study method were extracted. Random-effects model meta-analyses were done. DATA SYNTHESIS: For SMBP monitoring alone versus usual care (26 comparisons), moderate-strength evidence supports a lower BP with SMBP monitoring at 6 months (summary net difference, -3.9 mm Hg and -2.4 mm Hg for systolic BP and diastolic BP) but not at 12 months. For SMBP monitoring plus additional support versus usual care (25 comparisons), high-strength evidence supports a lower BP with use of SMBP monitoring, ranging from -3.4 to -8.9 mm Hg for systolic BP and from -1.9 to -4.4 mm Hg for diastolic BP, at 12 months in good-quality studies. For SMBP monitoring plus additional support versus SMBP monitoring alone or with less intense additional support (13 comparisons), low-strength evidence fails to support a difference. Across all comparisons, evidence for clinical outcomes is insufficient. For other surrogate or intermediate outcomes, low-strength evidence fails to show differences. LIMITATION: Clinical heterogeneity in protocols for SMBP monitoring, additional support, BP targets, and management; follow-up of 1 year or less in most studies, with sparse clinical outcome data. CONCLUSION: Self-measured BP monitoring with or without additional support lowers BP compared with usual care, but the BP effect beyond 12 months and long-term benefits remain uncertain. Additional support enhances the BP-lowering effect. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previous meta-analyses have revealed that HBPM can lower BP [5–8].”
From Self-measurement of blood pressure at home using a cuff device for change in blood pressure levels: systematic review and meta-analysis (2025) · cites this paper as [8]
In the citing paper
“and that additional co-interventions (such as telemonitoring) are preferable to achieving an adequate BP-lowering effect [5, 7, 8].”
From Self-measurement of blood pressure at home using a cuff device for change in blood pressure levels: systematic review and meta-analysis (2025) · cites this paper as [8]
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Whelton, P. K. (2002) · JAMA · doi:10.1001/jama.288.15.1882 · Cited by 1,473
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Interventions used to improve control of blood pressure in patients with hypertension
Glynn, L. G., Murphy, A. W., Smith, S. M., Schroeder, K., & Fahey, T. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005182.pub4 · Cited by 668
Green, B. B. (2008) · JAMA · doi:10.1001/jama.299.24.2857 · Cited by 659
McManus, R. J., Mant, J., Bray, E. P., Holder, R., Jones, M. I., Greenfield, S., Kaambwa, B., Banting, M., Bryan, S., Little, P., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60964-6 · Cited by 597
Owens, D. K., Lohr, K. N., Atkins, D., Treadwell, J. R., Reston, J. T., Bass, E. B., Chang, S., & Helfand, M. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.03.009 · Cited by 513
IMPROVEMENT OF MEDICATION COMPLIANCE IN UNCONTROLLED HYPERTENSION
Haynes, R. B., Gibson, E., Hackett, B., Sackett, D., Taylor, D. W., Roberts, R., & Johnson, A. (1976) · The Lancet · doi:10.1016/s0140-6736(76)91737-2 · Cited by 513
Friedman, R. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00353-3 · Cited by 510
Research works printed but not linked: 8
- Cheltsova A, 2010, Hypertension, 56, 109
- Johnson AL, 1978, Can Med Assoc J, 119, 1034
- Magid DJ, 2011, Am J Manag Care, 17, 96
- Midanik LT, 1991, Public Health Rep, 106, 85
- 10.1016/s0895-7061(04)00867-2 · DOI
- Shea S, 2007, Trans Am Clin Climatol Assoc, 118, 289
- 10.1001/jama.291.8.955 · DOI · Paper page
- Glynn LG, 2010, Cochrane Database Syst Rev, CD005182
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Meschia, J. F., Bushnell, C., Boden-Albala, B., Braun, L. T., Bravata, D. M., Chaturvedi, S., Creager, M. A., Eckel, R. H., Elkind, M. S. V., Fornage, M., et al. (2014) · Stroke · doi:10.1161/str.0000000000000046 · Cited by 2,650
2024 ESC Guidelines for the management of elevated blood pressure and hypertension
McEvoy, J. W., McCarthy, C. P., Bruno, R. M., Brouwers, S., Canavan, M. D., Ceconi, C., Christodorescu, R. M., Daskalopoulou, S. S., Ferro, C. J., Gerdts, E., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae178 · Cited by 2,298
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Metadata
- Authors
- Uhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M.
- Affiliations
- Lahey Hospital and Medical Center (US)
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2013-08-06
- Volume
- 159
- Issue
- 3
- Pages
- 185-194
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2063641811
- Cited by
- 368
- References
- 74
- Citations by year
- 2026: 10 · 2025: 24 · 2024: 32 · 2023: 23 · 2022: 29 · 2021: 31 · 2020: 47 · 2019: 35 · 2018: 28 · 2017: 35 · 2016: 28 · 2015: 28 · 2014: 14 · 2013: 4
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Annals of Internal Medicine
- Funders
- U.S. Public Health Service (HHSA 290 2007 10055-I 1)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Health Sciences › Nursing › Nutrition and Dietetics › Sodium Intake and Health
- Keywords
- self-measured blood pressure, hypertension, blood pressure control, patient support, usual care, systolic blood pressure, diastolic blood pressure
- MeSH terms
- Adult, Blood Pressure, Counseling, Humans, Hypertension, Patient Education as Topic, Social Support, Blood Pressure Monitoring, Ambulatory, Comparative Effectiveness Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-Measured Blood Pressure Monitoring in the Management of Hypertension: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.7326/0003-4819-159-3-201308060-00008
- The paper
- Uhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M. (2013). Self-Measured Blood Pressure Monitoring in the Management of Hypertension: A Systematic Review and Meta-analysis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-159-3-201308060-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.