Multicenter Prospective Validation of an Updated Proprietary Sepsis Prediction Model
Open accessAbstract
Importance: The Epic Sepsis Model version 2 (ESM v2) is a widely implemented proprietary sepsis prediction model, but no multicenter, external validation of its performance has been reported to guide adoption and use. Objective: To conduct a multicenter validation of the ESM v2 to compare performance against the original ESM v1, outline differences across heterogenous clinical sites, and compare model performance against clinician recognition of sepsis. Design, Setting, and Participants: This prognostic study included adult inpatient encounters at 4 large US health systems between August 31, 2023, and March 11, 2025. At each site, data were collected for a consecutive period immediately following new model implementation. Data were analyzed from July 23 to August 19, 2025. Main Outcomes and Measures: Sepsis was defined using Sepsis-3 clinical consensus criteria. Model discrimination was assessed using area under the receiver operating characteristic curve (AUROC) at the encounter level and prediction level with 4-hour, 12-hour, and hospitalization-wide time horizons. Performance against clinician recognition of sepsis was measured using antibiotics, lactate, and body culture orders. Results: Of 227 091 inpatient encounters, 7401 (3.3%; median [IQR] age, 65 [54-75] years; 3359 [45.4%] female; 2.7% Asian; 24.6% Black; 64.6% White; 7.1% Hispanic ethnicity) met sepsis criteria and 219 690 (96.7%; median [IQR] age, 48 [33-65] years; 123 563 [56.2%] female; 2.5% Asian; 38.8% Black; 49.6% White; 9.6% Hispanic ethnicity) did not. At the encounter level, the AUROC ranged from 0.82 (95% CI, 0.81-0.83) to 0.92 (95% CI, 0.92-0.93) across study sites. At the prediction level with a 12-hour time horizon, the AUROC ranged from 0.75 (95% CI, 0.74-0.75) to 0.85 (95% CI, 0.85-0.85). Comparison against clinician recognition of sepsis yielded a minor decrease in performance, with the resulting encounter-level AUROC ranging from 0.80 (95% CI, 0.79-0.81) to 0.90 (95% CI, 0.89-0.90) across sites. Positive predictive values remained low, from 0.13 (95% CI, 0.13-0.14) to 0.26 (95% CI, 0.25-0.27), with a high number needed to evaluate and high alert burden. Conclusions and Relevance: In this prognostic study of a new sepsis prediction model, a multicenter prospective validation performed across 4 major US health systems found improved discrimination for the early prediction of sepsis but noted high institutional variability, low positive predictive value, and high alert burden.
AI snapshot
Written from the paper’s full text.
TL;DR
This multicenter prospective validation of the Epic Sepsis Model version 2 (ESM v2) across 227,091 inpatient encounters at 4 US health systems found encounter-level AUROC between 0.82 and 0.92, but with high institutional variability, low positive predictive value, and high alert burden. ESM v2 outperformed ESM v1 across all metrics and sites, though performance was lower against clinician recognition of sepsis.
Key findings
- Among 227,091 encounters, 7,401 (3.3%) met Sepsis-3 criteria. Encounter-level AUROC for ESM v2 ranged from 0.82 (95% CI, 0.81-0.83) at Michigan to 0.92 (95% CI, 0.92-0.93) at MetroHealth. At the 60% sensitivity threshold, specificity ranged from 0.83 to 0.96, PPV from 0.13 to 0.26, and NPV from 0.97 to 0.99; threshold scores ranged from 14 to 37 across sites.
- At the prediction level with a 4-hour horizon, AUROC ranged from 0.75 to 0.86, sensitivity from 0.25 to 0.44, PPV from 0.02 to 0.04, and NNE from 24 to 69. At 12 hours, NNE ranged from 21 to 35; at the hospitalization-wide horizon, NNE improved to 4 to 8.
- ESM v2 outperformed ESM v1 across all performance metrics, thresholds, and sites. At 60% sensitivity, ESM v1 had encounter-level AUROC from 0.65 to 0.84 and PPV from 0.07 to 0.14.
- Against a composite clinician recognition definition, ESM v2 AUROC ranged from 0.80 to 0.90, with median prediction lead time ahead of clinician recognition from 1.4 to 7.1 hours. A fairness audit found no major deviations suggesting disproportionately better or worse performance by age, sex, race, or ethnicity; performance was closely associated with baseline sepsis rate. Alert burden was high, and an 8-hour silencing strategy reduced total alerts but low PPV and high NNE persisted.
Methods
- Prospective validation at 4 large US health systems (University of Michigan, Oregon Health & Science University, Emory Healthcare, MetroHealth) using consecutive post-implementation periods. Included adults aged 18 years or older evaluated in the ED or hospitalized with at least 1 prediction score from both models; excluded patients who met sepsis criteria, were discharged, or died before a model score.
- Sepsis outcome used Sepsis-3 criteria: suspected infection defined as body fluid culture plus first dose of at least 2 antibiotic doses from 72 hours before to 24 hours after culture order; organ dysfunction defined as a 2-point or greater change in SOFA score from encounter baseline between 48 hours before and 24 hours after suspected infection. Models generated scores every 15 minutes; ESM v2 was fine-tuned on site-specific historical data before implementation, and ESM v1 scores were calculated silently after implementation.
- Analysis assessed AUROC, and at each institution’s 60% sensitivity threshold calculated specificity, PPV, NPV, and NNE, with 95% CIs from 1000 bootstrap resamples. Performance was analyzed at encounter level and prediction level with 4-hour, 12-hour, and hospitalization-wide horizons; calibration plots, sensitivity analyses against clinician recognition indicators, a fairness audit, and alert burden simulations with an 8-hour silencing strategy were also performed.
Limitations
- The paper states that Sepsis-3 criteria have imperfect concordance with manual physician review, limiting analysis to cases that received cultures and antibiotic orders; postimplementation integration may introduce confirmation bias or model drift; the study did not differentiate ED, floor, and ICU sepsis; all sites fine-tuned the model, so base-model performance without fine-tuning is unknown; and the observational design was not intended to evaluate mortality or other clinical outcomes.
- The text also makes evident that the first-hour no-CBC exclusion removed 9.8% to 30.1% of sepsis-positive encounters across sites, potentially limiting early prediction for a substantial proportion of sepsis cases.
- The paper notes that simultaneous silent testing of both models was not feasible because sites depended on the models for clinical care, and the proprietary, site-fine-tuned nature of ESM v2 may limit generalizability of these performance estimates.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
18 of 21 cited sources checked · 5 supported · 0 flagged · accuracy not yet measured
- Study design and conductcitation
This study used Sepsis-3 clinical criteria to label sepsis cases, an approach that has imperfect concordance with the criterion standard approach of manual physician review.
“First, this study used Sepsis-3 clinical criteria to label sepsis cases, an approach that has imperfect concordance with the criterion standard approach of manual physician review.25,26,27,28”
Quote in the paperSubstantial claim3 of 3 sources checked- cites [25] Lindner, 2022, Ground truth labels challenge the validity of sepsis consensus definitions in critical illness., J Transl Med source
The Results section ('Validation of Sepsis-1/2 and Sepsis-3 clinical criteria against ground truth labels'; page unavailable) reports only fair agreement between Sepsis-3 criteria and expert sepsis-onset labels, supporting the imperfect-concordance point. The Methods describe those reference labels as daily judgments by senior physicians using a questionnaire, not sepsis labels established through manual physician chart review. The cited paper also cannot establish how the citing study labeled its own cases. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [26] Henry, 2019, Comparison of automated sepsis identification methods and electronic health record-based sepsis phenotyping: improving case identification accuracy by accounting for confounding comorbid conditions., Crit Care Explor source
The Discussion reports that automated Sepsis-3 can identify many false-positive cases, supporting imperfect agreement with physician assessment. But it says no gold standard for sepsis exists and physician case review is subjective. The paper also reports a direct physician-review comparison for ESP, not Sepsis-3, so it does not establish the stated criterion-standard comparison for Sepsis-3. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [27] Rhee, 2019, Variation in identifying sepsis and organ dysfunction using administrative versus electronic clinical data and impact on hospital outcome comparisons., Crit Care Med source
The Discussion says the paper’s EHR-based clinical criteria are an imperfect reference standard and that there is no true gold standard for sepsis. But the paper did not review medical records to confirm its criteria (Discussion, limitations), so it does not establish their concordance with manual physician review or describe that review as the criterion standard. The citing study’s own use of Sepsis-3 is not a finding attributed to this source. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
Patient complexity and baseline sepsis rates affect the performance of sepsis prediction models.
“These factors support prior evidence that patient complexity and baseline sepsis rates affect the performance of sepsis prediction models.13”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [13] Lyons, 2023, Factors associated with variability in the performance of a proprietary sepsis prediction model across 9 networked hospitals in the US., JAMA Intern Med source
- Interpretationcitation
The overall AUROC of the new model was generally lower than that reported in other frontier sepsis prediction models, such as COMPOSER, Targeted Real-time Early Warning System, and SepsisWatch.
“While the overall performance (eg, AUROC) of the new model was generally lower than that reported in other frontier sepsis prediction models, such as COMPOSER,18 Targeted Real-time Early Warning System,19 and SepsisWatch,20”
Quote in the paperNot a substantial claim3 of 3 sources checked- cites [18] Boussina, 2024, Impact of a deep learning sepsis prediction model on quality of care and survival., NPJ Digit Med source
- cites [19] Henry, 2022, Factors driving provider adoption of the TREWS machine learning-based early warning system and its effects on sepsis treatment timing., Nat Med source
The 'Targeted Real-time Early Warning System (TREWS)' section identifies TREWS as a machine-learning sepsis early warning system, so the citation supports its identification as an example. The Discussion reports sensitivity and precision, but our copy does not report a TREWS AUROC; it therefore does not substantiate the implied AUROC comparison with the citing paper's new model. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [20] Valan, 2025, Evaluating sepsis watch generalizability through multisite external validation of a sepsis machine learning model., NPJ Digit Med source
- Interpretationcitation
The new model outperforms other more commonly deployed prediction models and clinical prediction scores, such as Systemic Inflammatory Response Syndrome, SOFA, and Quick SOFA.
“it outperforms other more commonly deployed prediction models21 and clinical prediction scores, such as Systemic Inflammatory Response Syndrome, SOFA, and Quick SOFA.22”
Quote in the paperSubstantial claim2 of 2 sources checked- cites [21] Wallgren, 2021, Performance of NEWS2, RETTS, clinical judgment and the Predict Sepsis screening tools with respect to identification of sepsis among ambulance patients with suspected infection: a prospective cohort study., Scand J Trauma Resusc Emerg Med source
The Results section compares Predict Sepsis tools with NEWS2, RETTS and clinical judgment, but does not compare them with SIRS, SOFA or qSOFA. A search for those named scores found SOFA used to define the sepsis outcome, not as a competing prediction score. Our copy therefore does not establish the attributed outperformance claim. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [22] Schertz, 2023, Sepsis prediction model for determining sepsis vs SIRS, qSOFA, and SOFA., JAMA Netw Open source
The Findings report that the SPM had better balanced accuracy than SIRS, SOFA, and qSOFA at a predicting sepsis score threshold of 8 or greater. The Conclusions describe that advantage as marginal and note poorer timeliness, so the unqualified claim that it outperforms these scores overstates the result. The separate claim about other prediction models is attached to citation 21, not this source. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Premisecitation
The Epic Sepsis Model version 1 was found to have poor discrimination and calibration in several external validations across different health systems.
“Despite its widespread deployment, this model was found to have poor discrimination and calibration in several external validations across different health systems.12,13,14,15”
Quote in the paperSubstantial claim3 of 4 sources checked- cites [12] Wong, 2021, External validation of a widely implemented proprietary sepsis prediction model in hospitalized patients., JAMA Intern Med source
The Results and Discussion report poor discrimination and calibration for the Epic Sepsis Model in this external validation. The Methods and Discussion specify that it was conducted at a single academic health system, Michigan Medicine; this paper therefore does not establish the claim about several external validations across different health systems. The passages do not identify the model as version 1. Page numbers are unavailable in our copy. (LLM, conf=0.89)
Experimental — accuracy not yet measured - cites [13] Lyons, 2023, Factors associated with variability in the performance of a proprietary sepsis prediction model across 9 networked hospitals in the US., JAMA Intern Med source
The Results report that ESM discrimination varied across nine hospitals in one network, with a C-statistic of 0.55 at the largest hospital. The Methods describe measuring discrimination, not calibration; the Discussion only suggests that increased COVID-19-related alerting may reflect miscalibration. This paper therefore supports poor discrimination at some hospitals, but not poor calibration established by several validations across different health systems. (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [14] Ostermayer, 2024, External validation of the Epic sepsis predictive model in 2 county emergency departments., JAMIA Open source
The Discussion reports poor diagnostic performance for ESPMv1 and says the results align with prior external validations. But the Limitations specify that this study covered one health system with two emergency departments, and our copy does not report poor calibration or establish the claim about several validations across different health systems. No page numbers are provided in the copy. (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [15] Kamran, 2024, Evaluation of sepsis prediction models before onset of treatment., NEJM AI source
- Findingown data
The Epic Sepsis Model version 2 had an encounter-level area under the receiver operating curve between 0.82 and 0.92 across the 4 study sites.
“This prognostic study of 227 091 inpatient encounters across 4 major US health systems found that the model had an area under the receiver operating curve between 0.82 and 0.92 but demonstrated high institutional variability, low positive predictive value, and high alert burden.”
- Also stated in: § Model Performance Across Study Sites · plain
“At the encounter level, the model had an AUROC ranging between 0.82 (95% CI, 0.81-0.83) and 0.92 (95% CI, 0.92-0.93).”
Quote in the paperSubstantial claim - Also stated in: § Model Performance Across Study Sites · plain
- Findingown data
At the 60% sensitivity threshold, negative predictive value ranged from 0.97 to 0.99 across study sites.
“At this threshold, specificity ranged from 0.83 (95% CI, 0.83-0.84) to 0.96 (95% CI, 0.96-0.96), PPV ranged from 0.13 (95% CI, 0.13-0.14) to 0.26 (95% CI, 0.25-0.27), and NPV ranged from 0.97 (95% CI, 0.97-0.97) to 0.99 (95% CI, 0.99-0.99).”
Quote in the paperNot a substantial claim - Findingown data
For true-positive cases, the median prediction lead time before sepsis positivity ranged from 1.9 to 10.3 hours across study sites.
“For true-positive cases, the median (IQR) prediction lead time before sepsis positivity ranged from 1.9 (0.7-6.6) hours to 10.3 (1.3-81.4) hours.”
Quote in the paperNot a substantial claim - Findingown data
The Epic Sepsis Model version 2 had low positive predictive value.
“This prognostic study of 227 091 inpatient encounters across 4 major US health systems found that the model had an area under the receiver operating curve between 0.82 and 0.92 but demonstrated high institutional variability, low positive predictive value, and high alert burden.”
Quote in the paperSubstantial claim - Findingown data
At the prediction level with a 4-hour time horizon, specificity ranged from 0.93 to 0.97 across study sites.
“At the prediction level with a 4-hour time horizon, AUROC ranged from 0.75 (95% CI, 0.75-0.76) to 0.86 (95% CI, 0.86-0.86), sensitivity ranged from 0.25 (95% CI, 0.24-0.26) to 0.44 (95% CI, 0.43-0.44), specificity ranged from 0.93 (95% CI, 0.93-0.93) to 0.97 (95% CI, 0.97-0.97), PPV ranged from 0.02 (95% CI, 0.01-0.02) to 0.04 (95% CI, 0.04-0.04), and the NNE ranged from 24 to 69 (Table 2).”
Quote in the paperNot a substantial claim - Findingown data
At the prediction level with a 4-hour time horizon, AUROC ranged from 0.75 to 0.86 across study sites.
“At the prediction level with a 4-hour time horizon, AUROC ranged from 0.75 (95% CI, 0.75-0.76) to 0.86 (95% CI, 0.86-0.86), sensitivity ranged from 0.25 (95% CI, 0.24-0.26) to 0.44 (95% CI, 0.43-0.44), specificity ranged from 0.93 (95% CI, 0.93-0.93) to 0.97 (95% CI, 0.97-0.97), PPV ranged from 0.02 (95% CI, 0.01-0.02) to 0.04 (95% CI, 0.04-0.04), and the NNE ranged from 24 to 69 (Table 2).”
Quote in the paperSubstantial claim - Findingown data
The Epic Sepsis Model version 2 demonstrated high institutional variability in performance across study sites.
“This prognostic study of 227 091 inpatient encounters across 4 major US health systems found that the model had an area under the receiver operating curve between 0.82 and 0.92 but demonstrated high institutional variability, low positive predictive value, and high alert burden.”
Quote in the paperSubstantial claim - Findingown data
At the prediction level with a 4-hour time horizon, positive predictive value ranged from 0.02 to 0.04 across study sites.
“At the prediction level with a 4-hour time horizon, AUROC ranged from 0.75 (95% CI, 0.75-0.76) to 0.86 (95% CI, 0.86-0.86), sensitivity ranged from 0.25 (95% CI, 0.24-0.26) to 0.44 (95% CI, 0.43-0.44), specificity ranged from 0.93 (95% CI, 0.93-0.93) to 0.97 (95% CI, 0.97-0.97), PPV ranged from 0.02 (95% CI, 0.01-0.02) to 0.04 (95% CI, 0.04-0.04), and the NNE ranged from 24 to 69 (Table 2).”
Quote in the paperNot a substantial claim - Findingown data
The Epic Sepsis Model version 2 had high alert burden.
“This prognostic study of 227 091 inpatient encounters across 4 major US health systems found that the model had an area under the receiver operating curve between 0.82 and 0.92 but demonstrated high institutional variability, low positive predictive value, and high alert burden.”
Quote in the paperSubstantial claim - Findingown data
At the 60% sensitivity threshold, positive predictive value ranged from 0.13 to 0.26 across study sites.
“At this threshold, specificity ranged from 0.83 (95% CI, 0.83-0.84) to 0.96 (95% CI, 0.96-0.96), PPV ranged from 0.13 (95% CI, 0.13-0.14) to 0.26 (95% CI, 0.25-0.27), and NPV ranged from 0.97 (95% CI, 0.97-0.97) to 0.99 (95% CI, 0.99-0.99).”
Quote in the paperNot a substantial claim - Findingown data
The model score threshold matching 60% sensitivity ranged from 14 to 37 across institutions.
“The model score threshold score matching 60% sensitivity ranged from 14 to 37 across institutions.”
Quote in the paperNot a substantial claim - Findingown data
At the prediction level with a 4-hour time horizon, sensitivity ranged from 0.25 to 0.44 across study sites.
“At the prediction level with a 4-hour time horizon, AUROC ranged from 0.75 (95% CI, 0.75-0.76) to 0.86 (95% CI, 0.86-0.86), sensitivity ranged from 0.25 (95% CI, 0.24-0.26) to 0.44 (95% CI, 0.43-0.44), specificity ranged from 0.93 (95% CI, 0.93-0.93) to 0.97 (95% CI, 0.97-0.97), PPV ranged from 0.02 (95% CI, 0.01-0.02) to 0.04 (95% CI, 0.04-0.04), and the NNE ranged from 24 to 69 (Table 2).”
Quote in the paperNot a substantial claim - Findingown data
At the 60% sensitivity threshold, specificity ranged from 0.83 to 0.96 across study sites.
“At this threshold, specificity ranged from 0.83 (95% CI, 0.83-0.84) to 0.96 (95% CI, 0.96-0.96), PPV ranged from 0.13 (95% CI, 0.13-0.14) to 0.26 (95% CI, 0.25-0.27), and NPV ranged from 0.97 (95% CI, 0.97-0.97) to 0.99 (95% CI, 0.99-0.99).”
Quote in the paperNot a substantial claim - Findingown data
ESM v2 demonstrated moderate to strong discrimination for early sepsis prediction.
“we found that the ESM v2 demonstrated moderate to strong discrimination for early sepsis prediction”
Quote in the paperSubstantial claim - Findingown data
Median time from hospital presentation to sepsis positivity ranged from 3.7 to 10.3 hours across study sites.
“Median (IQR) time from hospital presentation to sepsis positivity ranged from 3.7 (1.8-9.3) hours to 10.3 (1.3-81.4) hours.”
Quote in the paperNot a substantial claim - Findingown data
No major deviations from the trend of model performance being associated with baseline sepsis rate were observed that suggested disproportionately better or worse performance based independently on age, sex, race, or ethnicity.
“No major deviations from this trend were observed that suggested disproportionately better or worse performance based independently on age, sex, race, or ethnicity.”
Quote in the paperSubstantial claim - Findingown data
The median prediction lead time to sepsis positivity was 1.9 to 10.2 hours.
“The median prediction lead time to sepsis positivity (1.9-10.2 hours)”
Quote in the paperSubstantial claim - Findingown data
At all sites, a high frequency of alerts occurred immediately after admission, followed by a gradual decline as patients progressed further into their hospital course.
“At all sites, a high frequency of alerts occurred immediately after admission, followed by a gradual decline as patients progressed further into their hospital course.”
Quote in the paperNot a substantial claim - Findingown data
Baseline sepsis incidence ranged from 2.2% to 7.1% across study sites.
“The baseline sepsis incidence ranged from 2.2% to 7.1% across sites, with higher sepsis rates observed at tertiary care centers (Table 2).”
Quote in the paperNot a substantial claim - Findingown data
NNE ranged from 21 to 35 at the 12-hour time horizon.
“For instance, NNE ranged from 21 to 35 at the 12-hour time horizon.”
Quote in the paperSubstantial claim - Findingown data
The number needed to evaluate improved with longer time horizons.
“AUROC dropped and PPV and NNE improved with longer time horizons.”
Quote in the paperNot a substantial claim - Findingown data
For true-positive cases, the median prediction lead time ahead of clinician recognition ranged from 1.4 to 7.1 hours across study sites.
“For true-positive cases, the median (IQR) prediction lead time ahead of clinician recognition ranged from 1.4 (0.6-4.0) hours to 7.1 (2.4-15.1) hours.”
Quote in the paperSubstantial claim - Findingown data
Following implementation of the new model, sepsis incidence rates remained consistent with historical rates at all study sites.
“Following implementation of the new model, sepsis incidence rates remained consistent with historical rates at all study sites.”
Quote in the paperNot a substantial claim - Findingown data
The new model demonstrated weaker performance at sites with only tertiary care centers (University of Michigan and Oregon Health & Sciences University) than at sites that included community and safety net hospitals (Emory University and MetroHealth).
“Second, the new model demonstrated weaker performance at sites with only tertiary care centers (University of Michigan and Oregon Health & Sciences University) than at sites that included community and safety net hospitals (Emory University and MetroHealth).”
Quote in the paperSubstantial claim - Findingown data
The new model demonstrated better performance than the original when compared against clinician recognition of sepsis.
“The new model also demonstrated better performance than the original when compared against clinician recognition of sepsis.”
Quote in the paperSubstantial claim - Findingown data
At the prediction level with a 4-hour time horizon, the number needed to evaluate ranged from 24 to 69 across study sites.
“At the prediction level with a 4-hour time horizon, AUROC ranged from 0.75 (95% CI, 0.75-0.76) to 0.86 (95% CI, 0.86-0.86), sensitivity ranged from 0.25 (95% CI, 0.24-0.26) to 0.44 (95% CI, 0.43-0.44), specificity ranged from 0.93 (95% CI, 0.93-0.93) to 0.97 (95% CI, 0.97-0.97), PPV ranged from 0.02 (95% CI, 0.01-0.02) to 0.04 (95% CI, 0.04-0.04), and the NNE ranged from 24 to 69 (Table 2).”
Quote in the paperNot a substantial claim - Findingown data
Against a composite of clinical indicators of clinician recognition, the model's AUROC ranged from 0.80 to 0.90 across study sites.
“Comparison of the model against a composite of clinical indicators of clinician recognition (ie, antibiotics, lactate, and body culture orders) resulted in a small drop in discriminatory performance, with a resulting AUROC ranging from 0.80 (95% CI, 0.79-0.81) to 0.90 (95% CI, 0.89-0.90) across sites.”
Quote in the paperSubstantial claim - Findingown data
The NNE improves to a range of 4 to 8 alerts at the hospitalization-wide time horizon.
“The NNE improves to a range of 4 to 8 alerts at the hospitalization-wide time horizon”
Quote in the paperSubstantial claim - Findingown data
The new sepsis prediction model achieved an overall encounter-level AUROC between 0.82 and 0.92 across sites.
“The new sepsis prediction model achieved an overall encounter-level AUROC between 0.82 and 0.92 across sites”
Quote in the paperSubstantial claim - Findingown data
AUROC dropped with longer time horizons.
“AUROC dropped and PPV and NNE improved with longer time horizons.”
Quote in the paperNot a substantial claim - Findingreasoning
Up to 30% of patients with sepsis at the University of Michigan did not have any reliable model predictions prior to sepsis onset.
“which can result in a substantial proportion of patients with sepsis (eg, up to 30% at the University of Michigan) not having any reliable model predictions prior to sepsis onset.”
Quote in the paperNot a substantial claim- Rests on an assumption: The new sepsis prediction model cannot produce accurate predictions in the first hour of admission in absence of a CBC result.
- Findingown data
Positive predictive value improved with longer time horizons.
“AUROC dropped and PPV and NNE improved with longer time horizons.”
Quote in the paperNot a substantial claim - Findingnone given
Model performance was closely associated with baseline sepsis rate.
“Model performance was closely associated with baseline sepsis rate.”
Quote in the paperNot a substantial claim - Study design and conductown data
The percentage of sepsis-positive encounters excluded due to the first-hour no complete blood count exclusion ranged from 9.8% to 30.1% across study sites.
“The percentage of sepsis positive encounters excluded due to the first hour no CBC exclusion ranged from 9.8% to 30.1% across sites.”
Quote in the paperNot a substantial claim - Study design and conductnone given
The use of prospective, real-time data collected immediately following implementation of the new model at each study site closely reflects model performance under real-world deployment conditions.
“Second, the use of prospective, real-time data collected immediately following implementation of the new model at each study site closely reflects model performance under real-world deployment conditions.”
Quote in the paperSubstantial claim - Interpretationown data
A health system using this model would need to manage or silence approximately 21 to 35 alerts to catch a single sepsis case that occurs within the next 12 hours.
“This means that a health system using this model would need to manage or silence approximately 21 to 35 alerts to catch a single sepsis case of sepsis that occurs within the next 12 hours.”
Quote in the paperSubstantial claim - Study design and conductreasoning
Simultaneous silent testing of both models was not feasible because study sites were dependent on these models for clinical care.
“While an ideal solution would have been simultaneous silent testing of both models, this was not feasible, as study sites were dependent on these models for clinical care.”
Quote in the paperSubstantial claim - Study design and conductnone given
Model performance analysis was conducted after the new model was already integrated into clinical workflows.
“Second, model performance analysis was conducted after the new model was already integrated into clinical workflows.”
Quote in the paperSubstantial claim - Interpretationown data
The median prediction lead time suggested an adequate time window to reevaluate patients, order additional diagnostic testing, or initiate treatment.
“suggested an adequate time window to reevaluate patients, order additional diagnostic testing, or initiate treatment.”
Quote in the paperSubstantial claim - Study design and conductnone given
This was the first large-scale multicenter validation study of this new sepsis prediction model with diverse representation across US geographic locations and health system types.
“First, this was the first large-scale multicenter validation study of this new sepsis prediction model with diverse representation across US geographic locations (Midwest, Pacific Northwest, South) and health system types (tertiary care center, community hospital, safety net hospital)”
Quote in the paperSubstantial claim - Interpretationreasoning
Direct replacement of the original model with the new version was less likely to induce postimplementation model drift than the introduction of a novel system.
“Therefore, direct replacement of the original model with the new version was less likely to induce postimplementation model drift than the introduction of a novel system.”
Quote in the paperSubstantial claim - Study design and conductown data
The study was a prospective validation conducted at 4 large US health systems.
“We conducted a prospective validation study at 4 large US health systems (University of Michigan, Ann Arbor, Michigan; Oregon Health & Science University, Portland, Oregon; Emory Healthcare, Atlanta, Geogia; and MetroHealth, Cleveland, Ohio).”
Quote in the paperSubstantial claim - Interpretationown data
The new sepsis prediction model is likely more effective at identifying community-onset than hospital-onset sepsis.
“First, the new sepsis prediction model is likely more effective at identifying community-onset than hospital-onset sepsis.”
Quote in the paperSubstantial claim
- Classified as probably not a substantial claim. 15
- May combine two claims. 20
- The quote only partly states this claim. 1
Classified as probably not a substantial claim.
PremisecitationPrior sepsis research has suggested physiologic and epidemiologic heterogeneity between community-acquired and hospital-acquired sepsis populations.
“Prior sepsis research has suggested physiologic and epidemiologic heterogeneity between community-acquired and hospital-acquired sepsis populations30”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [30] Markwart, 2020, Epidemiology and burden of sepsis acquired in hospitals and intensive care units: a systematic review and meta-analysis., Intensive Care Med source
The Introduction distinguishes community-acquired from hospital-acquired sepsis, and the Discussion reports that patients with hospital-acquired sepsis have longer hospital or ICU stays than patients with community-acquired sepsis. This supports a difference between the populations, but the passages do not establish physiologic heterogeneity between them; the reported inter-study heterogeneity concerns variation across studies, not that comparison. Page numbers were not available in our copy. (LLM, conf=0.86)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationHospital-onset sepsis is more clinically complex and harder to predict than community-acquired sepsis.
“prior research suggesting that hospital-onset sepsis is more clinically complex and harder to predict than community-acquired sepsis.23,24”
Quote in the paperSubstantial claim2 of 2 sources checked- cites [23] Rhee, 2019, Epidemiology of hospital-onset versus community-onset sepsis in U.S. hospitals and association with mortality: a retrospective analysis using electronic clinical data., Crit Care Med source
The Results (Patient Characteristics; page not provided) show that hospital-onset sepsis patients had more comorbidities and higher SOFA scores, supporting the description of greater clinical complexity. The Discussion (page not provided) suggests hospital-onset sepsis may be slower to recognize, but it does not establish that it is harder to predict. The paper also distinguishes community-onset sepsis from infections necessarily acquired in the community. (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [24] Page, 2015, Community-, healthcare-, and hospital-acquired severe sepsis hospitalizations in the University HealthSystem Consortium., Crit Care Med source
The Discussion (page unavailable) says hospital-acquired and community-acquired severe sepsis likely differ in clinical presentation and may require different detection strategies; it also notes that inpatient wards often lack frequent monitoring. This supports a distinction in detection challenges, but the paper does not establish that hospital-onset sepsis is more clinically complex or harder to predict than community-acquired sepsis. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Classified as probably not a substantial claim.
PremisecitationThe Sepsis-3 consensus framework for sepsis coding and research recommends using concomitant orders for blood cultures and antibiotics within a specified period to define suspected infection.
“The Sepsis-3 consensus framework for sepsis coding and research recommends using concomitant orders for blood cultures and antibiotics within a specified period to define suspected infection.4”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [4] Singer, 2016, The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3)., JAMA source
In Results/Recommendations, the paper describes a research cohort in which suspected infection was identified by cultures being sampled and antibiotics being received. It does not recommend concomitant orders within a specified period as a definition for coding and research; the Implications section instead discusses proxies such as antibiotic commencement or clinical probability of infection. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationPostimplementation model drift due to changes in clinician behavior is a widely recognized challenge in the evaluation of clinical prediction models with no standard solution.
“Postimplementation model drift due to changes in clinician behavior is a widely recognized challenge in the evaluation of clinical prediction models with no standard solution.29”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [29] Ansari, 2025, Challenges in the postmarket surveillance of clinical prediction models., NEJM AI source
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductcitationThe reporting of this study was guided by TRIPOD+AI reporting guidelines.
“The reporting of this study was guided by Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis updated for artificial intelligence (TRIPOD+AI) reporting guidelines.16”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [16] Collins, 2024, TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods., BMJ source
May combine two claims.
Findingown dataHigher rates of sepsis were observed in older patients, male patients, White patients, and patients with non-Hispanic ethnicity.
“Higher rates of sepsis were observed in older patients, male patients, White patients, and patients with non-Hispanic ethnicity.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingown dataHigher sepsis rates were observed at tertiary care centers.
“The baseline sepsis incidence ranged from 2.2% to 7.1% across sites, with higher sepsis rates observed at tertiary care centers (Table 2).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataA theoretical 8-hour silencing strategy substantially decreased total alert burden, but low PPV and high NNE persisted.
“A theoretical 8-hour silencing strategy substantially decreased total alert burden, but low PPV and high NNE persisted.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataOur analysis found low PPV and high NNE associated with this model.
“Our analysis found low PPV and high NNE associated with this model.”
Quote in the paperSubstantial claimMay combine two claims.
Findingnone givenThe new model maintained a moderate level of performance when compared against clinician recognition of sepsis, where the original model did not.
“The new model also maintained a moderate level of performance when compared against clinician recognition of sepsis, where the original model did not.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataAt the threshold matching a sensitivity of 0.60, the original ESM v1 had an encounter-level AUROC ranging from 0.65 to 0.84 and a PPV ranging from 0.07 to 0.14.
“At the threshold matching a sensitivity of 0.60, the original had an encounter-level AUROC ranging from 0.65 (95% CI, 0.64-0.65) to 0.84 (95% CI, 0.83-0.85) and a PPV ranging from 0.07 (95% CI, 0.07-0.08) to 0.14 (95% CI, 0.14-0.15).”
Quote in the paperSubstantial claimMay combine two claims.
FindingreasoningTertiary care sites had higher baseline sepsis rates, longer median times to sepsis positivity, longer median length of stay, a higher number of predictions per patient, and lower overall model performance against clinician recognition.
“Tertiary care sites had higher baseline sepsis rates, longer median times to sepsis positivity, longer median length of stay, a higher number of predictions per patient, and lower overall model performance against clinician recognition.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataESM v2 performance varied significantly across study sites, including in AUROC, thresholds matching 60% sensitivity, prediction lead time, and performance against clinician suspicion.
“with high variation in performance among institutions.”
- Also stated in: § Discussion · plain
“High variability was noted in model performance across study sites”
- Also stated in: § Discussion · plain
“Discriminative accuracy (AUROC, 0.82-0.92), thresholds matching 60% sensitivity (14 to 37), prediction lead time (1.5-9.1 hours) and decrease in model performance against clinician suspicion all varied significantly across institutions.”
Quote in the paperSubstantial claim- Also stated in: § Discussion · plain
May combine two claims.
Findingown dataThe new model outperformed ESM v1 across all performance metrics, at all model thresholds, and at all study sites.
“The new model outperformed the ESM v1 across all performance metrics, at all model thresholds, and at all study sites.”
- Also stated in: § Discussion · plain
“ESM v2 performance was superior to that of ESM v1 across all metrics.”
Quote in the paperSubstantial claim- Also stated in: § Discussion · plain
May combine two claims. The quote only partly states this claim.
FindingreasoningThe new model demonstrated stronger performance at institutions with earlier sepsis onset times, a higher proportion of sepsis cases occurring in the ED, and lower sepsis incidence rates.
“The new model demonstrated stronger performance at institutions with earlier sepsis onset times and a higher proportion of sepsis cases occurring in the ED, which is consistent with community-acquired cases.”
- Also stated in: § Strengths and Limitations · hedged
“This is consistent with our findings that suggested superior performance of this model at sites with lower sepsis incidence rates and earlier times to sepsis positivity.”
Quote in the paperSubstantial claim- Also stated in: § Strengths and Limitations · hedged
May combine two claims.
Findingown dataComparison of sepsis incidence rates following model integration against historical rates found no significant difference at our study sites, suggesting that introduction of the new model did not significantly change sepsis labeling rates.
“First, comparison of sepsis incidence rates following model integration against historical rates found no significant difference at our study sites, suggesting that introduction of the new model did not significantly change sepsis labeling rates.”
Quote in the paperSubstantial claimMay combine two claims.
Study design and conductreasoningUse of this clinical sepsis definition limited the analysis to sepsis cases that eventually received cultures and antibiotic orders and did not include any sepsis cases that did not eventually receive treatment.
“Use of this clinical sepsis definition limited the analysis to sepsis cases that eventually received cultures and antibiotic orders and did not include any sepsis cases that did not eventually receive treatment.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Study design and conductnone givenAt each site, data were collected for a consecutive time period immediately following model implementation.
“At each site, data were collected for a consecutive time period immediately following model implementation.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Study design and conductnone givenThe analysis of model performance against multiple clinician recognition metrics and at multiple time horizons provides a nuanced perspective of the real-world clinical trade-offs among model precision, timeliness, and false-positive rates.
“Furthermore, the analysis of model performance against multiple clinician recognition metrics and at multiple time horizons provides a nuanced perspective of the real-world clinical trade-offs among model precision, timeliness, and false-positive rates.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationAutomated sepsis prediction tools often lack generalizability and are commonly implemented by health systems without internal validation.
“However, such tools often lack generalizability and are commonly implemented by health systems without internal validation,8 potentially compromising sepsis care through missed or delayed treatment.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Nong, 2025, Current use and evaluation of artificial intelligence and predictive models in US hospitals., Health Aff (Millwood) source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductreasoningThe study was approved by the institutional review board at each participating site, and informed consent was waived due to a minimal risk exemption for secondary research.
“This prognostic study was approved by the institutional review board at each participating site. The requirement for informed consent was waived due to a minimal risk exemption for secondary research.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductreasoningChanges in alert performance may have affected clinician behavior, including the frequency and timing of antibiotic or body culture orders.
“Changes in alert performance may have affected clinician behavior, including the frequency and timing of antibiotic or body culture orders.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSepsis prediction models may be more effective in identifying early-onset community-acquired sepsis cases in the ED than on the floor and intensive care unit.
“and that sepsis prediction models may be more effective in identifying early-onset community-acquired sepsis cases in the ED than on the floor and intensive care unit.31”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [31] Tarabichi, 2022, Improving timeliness of antibiotic administration using a provider and pharmacist facing sepsis early warning system in the emergency department setting: a randomized controlled quality improvement initiative., Crit Care Med source
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataA fairness audit was performed to determine if the model had variable performance across subpopulations stratified by age, sex, race, and ethnicity.
“A fairness audit was performed to determine if the model had variable performance across subpopulations stratified by age, sex, race, and ethnicity.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
InterpretationreasoningThe first hour CBC exclusion rate may have affected model performance differently across sites.
“Finally, the first hour CBC exclusion rate may have affected model performance differently across sites.”
Quote in the paperSubstantial claim- Rests on an assumption: The new sepsis prediction model cannot produce accurate predictions in the first hour of admission in absence of a CBC result.
- Rests on an assumption: Health systems differ in their ability to consistently draw and run a CBC within the first hour of care due to variations in clinical workflows, patient volume, and laboratory access.
May combine two claims.
Study design and conductreasoningThis may have introduced confirmation bias in our Sepsis-3 abstracted outcome labels and inflated model accuracy.
“This may have introduced confirmation bias in our Sepsis-3 abstracted outcome labels and inflated model accuracy.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataBecause all study sites performed model fine-tuning prior to implementation, we cannot comment on the performance of the base model without fine-tuning.
“Fourth, because all our study sites performed model fine-tuning prior to implementation, we cannot comment on the performance of the base model without fine-tuning.”
Quote in the paperNot a substantial claimMay combine two claims.
Study design and conductown dataThis study analyzed observational data collected immediately after implementation of the new model at each study site and was not designed to evaluate its impact on clinical outcomes, such as mortality.
“Fifth, this study analyzed observational data collected immediately after implementation of the new model at each study site and was not designed to evaluate its impact on clinical outcomes, such as mortality.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Study design and conductnone givenThe standardized evaluation approach using Sepsis-3 criteria and a 60% sensitivity benchmark allowed for a clear comparison of performance between sites and models.
“The standardized evaluation approach using Sepsis-3 criteria and a 60% sensitivity benchmark allowed for a clear comparison of performance between sites and models.”
Quote in the paperSubstantial claimMay combine two claims.
Study design and conductreasoningThe use of Sepsis-3 abstraction for sepsis labeling allowed for a standardized approach to large-scale model validation across multiple study sites but limited the model performance analysis to clinician-centered outcomes.
“The use of Sepsis-3 abstraction for sepsis labeling allowed for a standardized approach to large-scale model validation across multiple study sites but limited the model performance analysis to clinician-centered outcomes”
Quote in the paperSubstantial claimMay combine two claims.
Study design and conductnone givenAll study sites previously used the original model for sepsis alerting, and no changes to the clinical workflow were made following implementation of the new model other than which model triggered sepsis alerts.
“Second, all study sites previously used the original model for sepsis alerting, and no changes to the clinical workflow were made following implementation of the new model other than which model triggered sepsis alerts.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown dataImplementation of alert silencing strategies can help reduce total alert burden, but cannot improve alert accuracy.
“The implementation of alert silencing strategies can help reduce total alert burden, but cannot improve alert accuracy.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim. May combine two claims.
Study design and conductnone givenThis study reported on model performance across the entire hospitalization and did not differentiate between sepsis diagnosed in the ED, on the inpatient floor, and in the intensive care unit.
“Third, this study reported on model performance across the entire hospitalization and did not differentiate between sepsis diagnosed in the ED, on the inpatient floor, and in the intensive care unit.”
Quote in the paperSubstantial claim
The paper relies on this without support.
An external multicenter validation of the Epic Sepsis Model version 2 had not been reported before this study.
“Despite broad adoption, an external multicenter validation of the new sepsis prediction model has yet to be reported.”
The paper relies on this without support.
The new sepsis prediction model is currently deployed at hundreds of US hospitals.
“the new sepsis prediction model is currently deployed at hundreds of US hospitals”
The paper relies on this without support.
The new sepsis prediction model cannot produce accurate predictions in the first hour of admission in absence of a CBC result.
“Per developer guidelines, the new sepsis prediction model cannot produce accurate predictions in the first hour of admission in absence of a CBC result.”
The paper relies on this without support.
Health systems differ in their ability to consistently draw and run a CBC within the first hour of care due to variations in clinical workflows, patient volume, and laboratory access.
“Health systems differ in their ability to consistently draw and run a CBC within the first hour of care due to variations in clinical workflows, patient volume, and laboratory access.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Evidence for Epic Sepsis Model version 1 must not be assumed to apply to version 2 or later versions.
“Evidence for version 1 must not be assumed to apply to version 2 or later versions [52,53].”
From The AI Hospital Formulary: A Practical Governance Framework for Prescribing, Monitoring, and Deprescribing Artificial Intelligence in Hospitals (2026) · cites this paper as [53]
In the multicenter prospective validation of Epic Sepsis Model version 2, encounter-level discrimination ranged from 0.82 to 0.92, but the positive predictive value remained 0.13 to 0.26, the alert burden was high, and thresholds and performance varied across institutions.
“Encounter-level discrimination ranged from 0.82 to 0.92, but the positive predictive value remained 0.13 to 0.26, the alert burden was high, and thresholds and performance varied across institutions [53].”
From The AI Hospital Formulary: A Practical Governance Framework for Prescribing, Monitoring, and Deprescribing Artificial Intelligence in Hospitals (2026) · cites this paper as [53]
A multicenter prospective validation published in 2026 evaluated version 2 of the Epic Sepsis Model in 227,091 encounters across four health systems.
“A multicenter prospective validation published in 2026 evaluated version 2 in 227,091 encounters across four health systems.”
From The AI Hospital Formulary: A Practical Governance Framework for Prescribing, Monitoring, and Deprescribing Artificial Intelligence in Hospitals (2026) · cites this paper as [53]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
OHSU sepsis in-hospital mortality percentage is too low
MinorTable 1 reports 309 in-hospital deaths among 2326 OHSU sepsis encounters. That is 13.3%, not the reported 12%.
Reported 12 · recomputed 13.284609
“| In-hospital mortality | 187 (0.6) | 90 (0.3) | 97 (7.2) | 574 (1.6) | 265 (0.8) | 309 (12)”
OHSU sepsis 30-day mortality percentage is too low
MinorTable 1 reports 330 deaths within 30 days among 2326 OHSU sepsis encounters. That is 14.2%, not the reported 13.0%.
Reported 13 · recomputed 14.187446
“| 30-d mortality | 338 (1.0) | 205 (0.7) | 133 (9.9) | 797 (2.2) | 467 (1.4) | 330 (13.0)”
Clinician-recognition lead-time IQR differs from Table 3
MinorThe text gives the lower end of the cross-site lead-time range an upper IQR bound of 4.0 hours, while Table 3 gives 5.2 hours for the corresponding Emory value.
“the median (IQR) prediction lead time ahead of clinician recognition ranged from 1.4 (0.6-4.0) hours to 7.1 (2.4-15.1) hours.”
“| Prediction lead time to clinician recognition, median (IQR), h | 7.1 (2.4-15.1) | 3.4 (0.0-42.6) | 1.4 (0.6-5.2) | 3.2 (0.5-13.4) |”
Discussion gives a different prediction lead-time range
MinorThe discussion states a cross-institution prediction lead-time range of 1.5 to 9.1 hours. Table 2 reports site medians ranging from 1.9 to 10.3 hours.
“prediction lead time (1.5-9.1 hours) and decrease in model performance against clinician suspicion all varied significantly across institutions.”
“| Prediction lead time to sepsis onset, median (IQR), h | 7.3 (2.7-16.7) | 10.3 (1.3-81.4) | 1.9 (0.7-6.6) | 4.2 (0.9-27.4) |”
Sepsis-positivity time range uses a prediction lead-time value
MinorThe text gives 10.3 hours as the upper end of the median time from presentation to sepsis positivity. Table 2 instead gives 8.7 hours as the highest median sepsis-positivity time; 10.3 hours is its OHSU prediction lead time.
“Median (IQR) time from hospital presentation to sepsis positivity ranged from 3.7 (1.8-9.3) hours to 10.3 (1.3-81.4) hours.”
“| Median sepsis positivity, (IQR), h | 8.7 (3.4-26.8) | 7.2 (2.0-75.8) | 3.7 (1.8-9.3) | 4.9 (1.9-21.1) |”
Cites
The third international consensus definitions for sepsis and septic shock (Sepsis-3).
Singer, M., Deutschman, C. S., Seymour, C. W., Shankar-Hari, M., Annane, D., Bauer, M., Bellomo, R., Bernard, G. R., Chiche, J.-D., Coopersmith, C. M., et al. (2016) · JAMA · doi:10.1001/jama.2016.0287 · Cited by 28,250 · see citing works
Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06506-y · Cited by 5,082 · see citing works
Collins, G. S., Moons, K. G. M., Dhiman, P., Riley, R. D., Beam, A. L., Van Calster, B., Ghassemi, M., Liu, X., Reitsma, J. B., van Smeden, M., et al. (2024) · BMJ · doi:10.1136/bmj-2023-078378 · Cited by 4,718 · see citing works
Self-citationTime to treatment and mortality during mandated emergency care for sepsis.
Seymour, C. W., Gesten, F., Prescott, H. C., Friedrich, M. E., Iwashyna, T. J., Phillips, G. S., Lemeshow, S., Osborn, T., Terry, K. M., & Levy, M. M. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1703058 · Cited by 2,225 · see citing works
Incidence and trends of sepsis in US hospitals using clinical vs claims data, 2009-2014.
Rhee, C., Dantes, R., Epstein, L., Murphy, D. J., Seymour, C. W., Iwashyna, T. J., Kadri, S. S., Angus, D. C., Danner, R. L., Fiore, A. E., et al. (2017) · JAMA · doi:10.1001/jama.2017.13836 · Cited by 1,884 · see citing works
Self-citationWong, A., Otles, E., Donnelly, J. P., Krumm, A., McCullough, J., DeTroyer-Cooley, O., Pestrue, J., Phillips, M., Konye, J., Penoza, C., et al. (2021) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2021.2626 · Cited by 995 · see citing works
Self-citationFleischmann-Struzek, C., Mellhammar, L., Rose, N., Cassini, A., Rudd, K. E., Schlattmann, P., Allegranzi, B., & Reinhart, K. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06151-x · Cited by 982 · see citing works
Markwart, R., Saito, H., Harder, T., Tomczyk, S., Cassini, A., Fleischmann-Struzek, C., Reichert, F., Eckmanns, T., & Allegranzi, B. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06106-2 · Cited by 399 · see citing works
Making Machine Learning Models Clinically Useful
Shah, N. H., Milstein, A., & Bagley, P. (2019) · JAMA · doi:10.1001/jama.2019.10306 · Cited by 294 · see citing works
There is no such thing as a validated prediction model
Van Calster, B., Steyerberg, E. W., Wynants, L., & van Smeden, M. (2023) · BMC Medicine · doi:10.1186/s12916-023-02779-w · Cited by 286 · see citing works
Cabitza, F., Campagner, A., Soares, F., García de Guadiana-Romualdo, L., Challa, F., Sulejmani, A., Seghezzi, M., & Carobene, A. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106288 · Cited by 284 · see citing works
Impact of a deep learning sepsis prediction model on quality of care and survival
Boussina, A., Shashikumar, S. P., Malhotra, A., Owens, R. L., El-Kareh, R., Longhurst, C. A., Quintero, K., Donahue, A., Chan, T. C., Nemati, S., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-023-00986-6 · Cited by 170 · see citing works
Page, D. B., Donnelly, J. P., & Wang, H. E. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001164 · Cited by 157 · see citing works
Henry, K. E., Adams, R., Parent, C., Soleimani, H., Sridharan, A., Johnson, L., Hager, D. N., Cosgrove, S. E., Markowski, A., Klein, E. Y., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-01895-z · Cited by 127 · see citing works
Rhee, C., Wang, R., Zhang, Z., Fram, D., Kadri, S. S., & Klompas, M. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003817 · Cited by 122 · see citing works
Nong, P., Adler-Milstein, J., Apathy, N. C., Holmgren, A. J., & Everson, J. (2025) · Health Affairs · doi:10.1377/hlthaff.2024.00842 · Cited by 104 · see citing works
Rhee, C., Jentzsch, M. S., Kadri, S. S., Seymour, C. W., Angus, D. C., Murphy, D. J., Martin, G. S., Dantes, R. B., Epstein, L., Fiore, A. E., et al. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003554 · Cited by 85 · see citing works
Self-citationSepsis prediction model for determining sepsis vs SIRS, qSOFA, and SOFA
Schertz, A. R., Lenoir, K. M., Bertoni, A. G., Levine, B. J., Mongraw-Chaffin, M., & Thomas, K. W. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.29729 · Cited by 78 · see citing works
Tarabichi, Y., Cheng, A., Bar-Shain, D., McCrate, B. M., Reese, L. H., Emerman, C., Siff, J., Wang, C., Kaelber, D. C., Watts, B., et al. (2022) · Critical Care Medicine · doi:10.1097/ccm.0000000000005267 · Cited by 76 · see citing works
Self-citationEvaluation of sepsis prediction models before onset of treatment
Kamran, F., Tjandra, D., Heiler, A., Virzi, J., Singh, K., King, J. E., Valley, T. S., & Wiens, J. (2024) · NEJM AI · doi:10.1056/aioa2300032 · Cited by 74 · see citing works
Self-citationLyons, P. G., Hofford, M. R., Yu, S. C., Michelson, A. P., Payne, P. R. O., Hough, C. L., & Singh, K. (2023) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.7182 · Cited by 62 · see citing works
Self-citationDantes, R., Kaur, H., Bouwkamp, B. A., Haass, K. A., Patel, P. R., Dudeck, M. A., Srinivasan, A., Magill, S. S., Wilson, W. W., Whitaker, M., et al. (2023) · MMWR Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm7234a2 · Cited by 43 · see citing works
Self-citationHenry, K. E., Hager, D. N., Osborn, T. M., Wu, A. W., & Saria, S. (2019) · Critical Care Explorations · doi:10.1097/cce.0000000000000053 · Cited by 22 · see citing works
Challenges in the postmarket surveillance of clinical prediction models.
Ansari, S., Baur, B., Singh, K., & Admon, A. J. (2025) · NEJM AI · doi:10.1056/aip2401116 · Cited by 22 · see citing works
Self-citationValan, B., Prakash, A., Ratliff, W., Gao, M., Muthya, S., Thomas, A., Eaton, J. L., Gardner, M., Nichols, M., Revoir, M., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01664-5 · Cited by 21 · see citing works
Benthin, C., Pannu, S., Khan, A., & Gong, M. (2016) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201603-172bc · Cited by 18 · see citing works
Ground truth labels challenge the validity of sepsis consensus definitions in critical illness.
Lindner, H. A., Schamoni, S., Kirschning, T., Worm, C., Hahn, B., Centner, F.-S., Schoettler, J. J., Hagmann, M., Krebs, J., Mangold, D., et al. (2022) · Journal of Translational Medicine · doi:10.1186/s12967-022-03228-7 · Cited by 14 · see citing works
Karlic, K. J., Clouse, T., Hogan, C. K., Garland, A., Seelye, S. M., Sussman, J. B., & Prescott, H. C. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202302-105oc · Cited by 14 · see citing works
Wallgren, U. M., Sjölin, J., Järnbert-Pettersson, H., & Kurland, L. (2021) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/s13049-021-00958-3 · Cited by 13 · see citing works
External validation of the Epic sepsis predictive model in 2 county emergency departments.
Ostermayer, D. G., Braunheim, B., Mehta, A. M., Ward, J., Andrabi, S., & Sirajuddin, A. M. (2024) · JAMIA Open · doi:10.1093/jamiaopen/ooae133 · Cited by 13 · see citing works
Currey, D., & Tarabichi, Y. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.07.056 · Cited by 9 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Lipskiy, N., & Flowerday, S. (2026) · Future Internet · doi:10.3390/fi18050232 · Cited by 2 · see citing works
Țocu, G., Ștefănescu, B., Țocu, L., Dimofte, F., Luțenco, V., Mihailov, O., Mihailov, R., & Matei, L. S. (2026) · Biomedicines · doi:10.3390/biomedicines14061271 · Cited by 1 · see citing works
“Therefore, before such models can be considered for broader clinical use, their discrimination, calibration, and incremental value over established clinical scores should be assessed carefully [25].”
Liu, B. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1896492 · Cited by 1 · see citing works
Epelde, F. (2026) · Hospitals · doi:10.3390/hospitals3030015
“Evidence for version 1 must not be assumed to apply to version 2 or later versions [52,53].”
InfluentialPatient Versus Prediction-Level Evaluation of a Dynamic Clinical Prediction Model of SepsisPreprint
Tuttle, M. L., Maas, C. C. H. M., An, J., Wessler, B. S., Harvey, W. F., Selker, H. P., Klaveren, D. V., & Kent, D. M. (2026) · Research Square · doi:10.21203/rs.3.rs-9726164/v1
“11 A third study using the localized version of ESMv2 demonstrated overall improved performance in both the hospitalization level (AUC 0.89) and prediction-level (AUC 0.84 with an 8 hour time horizon) analyses, but is not directly comparable as it has been reweighted to the characteristics of the…”
InfluentialAuthorised Interruption Capability in AI-intensive organisations
Velotto, G. (2026) · AI and Ethics · doi:10.1007/s43681-026-01207-y
“The same study reported substantial variation between hospitals, low positive predictive value, and high alert burden for staff [23].”
Cracks in the AI Crystal Ball: Why Clinical Prediction Tools Fall Short in the Real World
GAMBLE, D., Wong, A. H., & Baduashvili, A. (2026) · Journal of General Internal Medicine · doi:10.1007/s11606-026-10601-5
Self-citationDetecting infection after trauma: why clinical context still matters
Boyle, M., & Park, P. K. (2026) · Trauma Surgery & Acute Care Open · doi:10.1136/tsaco-2026-002504
Sandu, A. S., & Nistor, P. P. (2026) · Societies · doi:10.3390/soc16090289
“…proved acceptable, yet performance varied markedly by institution, positive predictive value remained low, and the alert burden was high—leading the investigators to conclude that adopting institutions must conduct their own local validation rather than rely upon the manufacturer’s figures [58].”
Finding time zero: how smart diagnostics and AI are reshaping sepsis care
McCurdy, M. T. (2026) · Frontiers in Disaster and Emergency Medicine · doi:10.3389/femer.2026.1898207
Hadler, R. A., Lakamana, S. K., Moorman, T., et al. (2026) · Critical Care Explorations · doi:10.1097/cce.0000000000001442
Knowing whether to rely: continuous awareness as a moral right in human-AI interaction
Sawaf, K. (2026) · AI and Ethics · doi:10.1007/s43681-026-01387-7
“Validation of the replacement, published in 2026, found performance varying widely across institutions [11].”
Lee, G.-M., Won, J.-Y., Cho, E. Y., Kim, J., Kim, K. J., Lee, Y. S., Lee, H. J., & Kim, J. (2026) · Journal of Medical Internet Research · doi:10.2196/95665
“In contrast, external evaluations of the Epic Sepsis Model, including Wong et al [82,83] and a subsequent multicenter prospective validation of version 2 of the Epic Sepsis Model published during paper revision, demonstrated that discrimination, calibration, transportability, and alert burden may…”
In silico biomedicine in the era of artificial intelligence: opportunities and challenges
Mustaffa, F.-E., Sajid, T., Ali, M., & Ashraf, N. M. (2026) · In Silico Research in Biomedicine · doi:10.1016/j.insi.2026.100629
Wang, B., Franciosi, A. N., O’Neill, L. M., Holden, S., McDonald, K., Gallagher, J., & Doran, P. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.126.053665
Zhang, Y., Trinh, S. H., Phelan, T., Byrd, T. F., Tourani, R., Kumar, V., Caraballo, P. J., Melton, G. B., & Simon Gyorgy, J. (2026) · Applied Clinical Informatics · doi:10.1055/a-2962-8091
POCUS en el choque séptico: de herramienta complementaria a estándar de cuidado
Vargas, I. E. V., & Huancollo, J. E. (2026) · Emergencia · doi:10.65920/rpmed.202613.48
When Risk Scores Become Trajectories: Interpreting Change After Model Updating
Bair, H. (2026) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.70654
Jia, Z., Zhao, X., Liu, X., & 李小丽 (2026) · Frontiers in Pharmacology · doi:10.3389/fphar.2026.1962609
Koca, H., & Ayvat, P. U. (2026) · Infection · doi:10.1007/s15010-026-03019-y
Garba, M., & Sharma, V. P. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7596238
- Authors
- Wong, A., Currey, D., Schwinne, M., Park-Egan, B., Meyer, S., Gutting, A., Cao, J., Khan, S., Dantes, R., Pan, T., Buchman, T., Singh, K., Bhavani, S. V., Lyons, P. G., Sjoding, M. W., & Tarabichi, Y.
- Affiliations
- University of Michigan (US)
- MetroHealth (US)
- Emory University (US)
- Oregon Health & Science University (US)
- UC San Diego Health System (US)
- Corresponding author
- Wong, Andrew
- ORCID
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2026-02-27
- Volume
- 9
- Issue
- 2
- Pages
- e260181
- ISSN
- 2574-3805 (ISSN-L)
- PMC
- PMC12949446
- OpenAlex
- W7131855346
- Semantic Scholar
- d13076c7b24c9600443063b2a42da33eb1c8cd75
- Cited by
- 21
- References
- 31
- Citations by year
- 2026: 21
- FWCI
- 85.31
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JAMA Network Open (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (submittedVersion, cc-by)
- Funders
- National Institutes of Health (1k08ca270383-01a1, 5r01hl158626-04)
- Topics
- Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
- Keywords
- sepsis prediction model, sepsis, external validation, model discrimination, Sepsis-3 criteria, inpatient encounters, lactate, body culture, model adoption, sepsis mortality, sepsis-related organ dysfunction
- MeSH terms
- Prediction Algorithms, Adult, Aged, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Prognosis, Prospective Studies, ROC Curve, United States, Sepsis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-27.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-27.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review