Automated Interpretation of Clinical Electroencephalograms Using Artificial Intelligence
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Importance: Electroencephalograms (EEGs) are a fundamental evaluation in neurology but require special expertise unavailable in many regions of the world. Artificial intelligence (AI) has a potential for addressing these unmet needs. Previous AI models address only limited aspects of EEG interpretation such as distinguishing abnormal from normal or identifying epileptiform activity. A comprehensive, fully automated interpretation of routine EEG based on AI suitable for clinical practice is needed. Objective: To develop and validate an AI model (Standardized Computer-based Organized Reporting of EEG–Artificial Intelligence [SCORE-AI]) with the ability to distinguish abnormal from normal EEG recordings and to classify abnormal EEG recordings into categories relevant for clinical decision-making: epileptiform-focal, epileptiform-generalized, nonepileptiform-focal, and nonepileptiform-diffuse. Design, Setting, and Participants: In this multicenter diagnostic accuracy study, a convolutional neural network model, SCORE-AI, was developed and validated using EEGs recorded between 2014 and 2020. Data were analyzed from January 17, 2022, until November 14, 2022. A total of 30 493 recordings of patients referred for EEG were included into the development data set annotated by 17 experts. Patients aged more than 3 months and not critically ill were eligible. The SCORE-AI was validated using 3 independent test data sets: a multicenter data set of 100 representative EEGs evaluated by 11 experts, a single-center data set of 9785 EEGs evaluated by 14 experts, and for benchmarking with previously published AI models, a data set of 60 EEGs with external reference standard. No patients who met eligibility criteria were excluded. Main Outcomes and Measures: Diagnostic accuracy, sensitivity, and specificity compared with the experts and the external reference standard of patients’ habitual clinical episodes obtained during video-EEG recording. Results: The characteristics of the EEG data sets include development data set (N = 30 493; 14 980 men; median age, 25.3 years [95% CI, 1.3-76.2 years]), multicenter test data set (N = 100; 61 men, median age, 25.8 years [95% CI, 4.1-85.5 years]), single-center test data set (N = 9785; 5168 men; median age, 35.4 years [95% CI, 0.6-87.4 years]), and test data set with external reference standard (N = 60; 27 men; median age, 36 years [95% CI, 3-75 years]). The SCORE-AI achieved high accuracy, with an area under the receiver operating characteristic curve between 0.89 and 0.96 for the different categories of EEG abnormalities, and performance similar to human experts. Benchmarking against 3 previously published AI models was limited to comparing detection of epileptiform abnormalities. The accuracy of SCORE-AI (88.3%; 95% CI, 79.2%-94.9%) was significantly higher than the 3 previously published models ( P < .001) and similar to human experts. Conclusions and Relevance: In this study, SCORE-AI achieved human expert level performance in fully automated interpretation of routine EEGs. Application of SCORE-AI may improve diagnosis and patient care in underserved areas and improve efficiency and consistency in specialized epilepsy centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Rajpurkar, P., Chen, E., Banerjee, O., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-021-01614-0 · Cited by 3,212
Thijs, R. D., Surges, R., O'Brien, T. J., & Sander, J. W. (2019) · The Lancet · doi:10.1016/s0140-6736(18)32596-0 · Cited by 2,183
Computing inter‐rater reliability and its variance in the presence of high agreement
Gwet, K. L. (2008) · British Journal of Mathematical and Statistical Psychology · doi:10.1348/000711006x126600 · Cited by 2,167
Prevalence and incidence of epilepsy: A systematic review and meta-analysis of international studies
Fiest, K. M., Sauro, K. M., Wiebe, S., Patten, S. B., Kwon, C.-S., Dykeman, J., Pringsheim, T., Lorenzetti, D. L., & Jetté, N. (2017) · Neurology · doi:10.1212/wnl.0000000000003509 · Cited by 1,902
An introduction to power and sample size estimation
Jones, S. R., Carley, S., & Harrison, M. (2003) · Emergency Medicine Journal · doi:10.1136/emj.20.5.453 · Cited by 643
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Self-citationOverintepretation of EEGs and Misdiagnosis of Epilepsy
Benbadis, S. R., & Tatum, W. O. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200302000-00005 · Cited by 257
Self-citationCriteria for defining interictal epileptiform discharges in EEG: A clinical validation study
Kural, M. A., Duez, L., Sejer Hansen, V., Larsson, P. G., Rampp, S., Schulz, R., Tankisi, H., Wennberg, R., Bibby, B. M., Scherg, M., et al. (2020) · Neurology · doi:10.1212/wnl.0000000000009439 · Cited by 215
Self-citationJing, J., Sun, H., Kim, J. A., Herlopian, A., Karakis, I., Ng, M., Halford, J. J., Maus, D., Chan, F., Dolatshahi, M., et al. (2020) · JAMA Neurology · doi:10.1001/jamaneurol.2019.3485 · Cited by 190
Errors in EEG Interpretation and Misdiagnosis of Epilepsy
Benbadis, S. R., & Lin, K. (2008) · European Neurology · doi:10.1159/000115641 · Cited by 178
Standardized computer-based organized reporting of EEG: SCORE – Second version
Beniczky, S., Aurlien, H., Brøgger, J. C., Hirsch, L. J., Schomer, D. L., Trinka, E., Pressler, R., Wennberg, R. A., Visser, G. H., Eisermann, M., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.07.418 · Cited by 159
Self-citationSpike detection: Inter-reader agreement and a statistical Turing test on a large data set
Scheuer, M. L., Bagic, A., & Wilson, S. B. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.11.005 · Cited by 154
Pavel, A. M., Rennie, J. M., de Vries, L. S., Blennow, M., Foran, A., Shah, D. K., Pressler, R. M., Kapellou, O., Dempsey, E. M., Mathieson, S. R., et al. (2020) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(20)30239-x · Cited by 151
Benbadis, S. R. (2007) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2007.05.013 · Cited by 126
Machine learning for detection of interictal epileptiform discharges
Lourenço, C. D. S., Tjepkema‐Cloostermans, M. C., & van Putten, M. J. A. M. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.02.403 · Cited by 113
Fürbass, F., Kural, M. A., Gritsch, G., Hartmann, M., Kluge, T., & Beniczky, S. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.02.032 · Cited by 106
Self-citationA Practical Guide for Routine EEG Studies in Epilepsy
Engel, J. (1984) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198404000-00001 · Cited by 91
Detecting abnormal electroencephalograms using deep convolutional networks
van Leeuwen, K. G., Sun, H., Tabaeizadeh, M., Struck, A. F., van Putten, M. J. A. M., & Westover, M. B. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.10.012 · Cited by 75
Japaridze, G., Loeckx, D., Buckinx, T., Larsen, S. A., Proost, R., Jansen, K., MacMullin, P., Paiva, N., Kasradze, S., Rotenberg, A., et al. (2022) · Epilepsia · doi:10.1111/epi.17200 · Cited by 74
Self-citationCharacteristics of EEG Interpreters Associated With Higher Interrater Agreement
Halford, J. J., Arain, A. M., Kalamangalam, G. P., LaRoche, S. M., Leonardo, B., Basha, M. M., Azar, N. J., Kutluay, E., Martz, G. U., Wolf, B. J., et al. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000344 · Cited by 56
Efficient use of clinical EEG data for deep learning in epilepsy
Lourenço, C. D. S., Tjepkema‐Cloostermans, M. C., & van Putten, M. J. A. M. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.01.035 · Cited by 44
Janmohamed, M., Nhu, D., Kuhlmann, L., Gilligan, A. K., Tan, C. W., Perucca, P., O'Brien, T. J., & Kwan, P. (2022) · Brain Communications · doi:10.1093/braincomms/fcac218 · Cited by 25
Cited by
Evaluating the Application of Large Language Models in Clinical Research Contexts
Perlis, R. H., & Fihn, S. D. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.35924 · Cited by 49
Metadata
- Authors
- Tveit, J., Aurlien, H., Plis, S., Calhoun, V. D., Tatum, W. O., Schomer, D. L., Arntsen, V., Cox, F., Fahoum, F., Gallentine, W. B., Gardella, E., Hahn, C. D., Husain, A. M., Kessler, S., Kural, M. A., Nascimento, F. A., Tankisi, H., Ulvin, L. B., Wennberg, R., & Beniczky, S.
- Venue
- JAMA Neurology
- Publisher
- American Medical Association (AMA)
- Published
- 2023-08-01
- Volume
- 80
- Issue
- 8
- Pages
- 805
- ISSN
- 2168-6149 (ISSN-L)
- OpenAlex
- W4381309178
- Cited by
- 242
- References
- 23
- FWCI
- 33.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.