Optical Coherence Tomography Angiography of the Peripapillary Retina in Glaucoma
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Vascular factors may have important roles in the pathophysiology of glaucoma. A practical method for the clinical evaluation of ocular perfusion is needed to improve glaucoma management. OBJECTIVE: To detect peripapillary retinal perfusion in glaucomatous eyes compared with normal eyes using optical coherence tomography (OCT) angiography. DESIGN, SETTING, AND PARTICIPANTS: Prospective observational study performed from July 24, 2013, to April 17, 2014. Participants were recruited and tested at Casey Eye Institute, Oregon Health & Science University. In total, 12 glaucomatous eyes and 12 age-matched normal eyes were analyzed. The optic disc region was imaged twice using a 3 × 3-mm scan by a 70-kHz, 840-nm-wavelength spectral OCT system. The split-spectrum amplitude-decorrelation angiography algorithm was used. Peripapillary flow index was calculated as the mean decorrelation value in the peripapillary region, defined as a 700-µm-wide elliptical annulus around the disc. Peripapillary vessel density was the percentage area occupied by vessels. The data statistical analysis was performed from October 30, 2013, to May 30, 2014. MAIN OUTCOMES AND MEASURES: Variability was assessed by the coefficient of variation. The Mann-Whitney test was used to compare the 2 groups of eyes. Correlations between vascular and visual field variables were assessed by linear regression analysis. RESULTS: In 12 normal eyes, a dense microvascular network around the disc was visible on OCT angiography. In 12 glaucomatous eyes, this network was visibly attenuated globally and focally. In normal eyes, between-visit reproducibilities of peripapillary flow index and peripapillary vessel density were 4.3% and 2.7% of the coefficient of variation, respectively, while the population variabilities of peripapillary flow index and peripapillary vessel density were 8.2% and 3.0% of the coefficient of variation, respectively. Peripapillary flow index and peripapillary vessel density in glaucomatous eyes were lower than those in normal eyes (P < .001 for both). Peripapillary flow index (Pearson r = -0.808) and peripapillary vessel density (Pearson r = -0.835) were highly correlated with visual field pattern standard deviation in glaucomatous eyes (P = .001 for both). The areas under the receiver operating characteristic curve for normal vs glaucomatous eyes were 0.892 for peripapillary flow index and 0.938 for peripapillary vessel density. CONCLUSIONS AND RELEVANCE: Using OCT angiography, reduced peripapillary retinal perfusion in glaucomatous eyes can be visualized as focal defects and quantified as peripapillary flow index and peripapillary vessel density, with high repeatability and reproducibility. Quantitative OCT angiography may have value in future studies to determine its potential usefulness in glaucoma evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The number of people with glaucoma worldwide in 2010 and 2020
Quigley, H. A. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.081224 · Cited by 7,394
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Self-citationThe impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
Jia, Y., Wei, E., Wang, X., Zhang, X., Morrison, J. C., Parikh, M., Lombardi, L. H., Gattey, D. M., Armour, R. L., Edmunds, B., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.021 · Cited by 740
Self-citationVascular risk factors for primary open angle glaucoma The Egna-Neumarkt Study
Bonomi, L. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00138-x · Cited by 728
Important Causes of Visual Impairment in the World Today
Congdon, N. G. (2003) · JAMA · doi:10.1001/jama.290.15.2057 · Cited by 698
Wong, T., & Mitchell, P. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60198-6 · Cited by 585
The vascular concept of glaucoma
Flammer, J. (1994) · Survey of Ophthalmology · doi:10.1016/0039-6257(94)90041-8 · Cited by 439
Kraus, M. F., Potsaid, B., Mayer, M. A., Bock, R., Baumann, B., Liu, J. J., Hornegger, J., & Fujimoto, J. G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001182 · Cited by 366
Open-Angle Glaucoma—An Epidemiologic Overview
Leske, M. C. (2007) · Ophthalmic Epidemiology · doi:10.1080/09286580701501931 · Cited by 272
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Yarmohammadi, A., Zangwill, L. M., Diniz-Filho, A., Suh, M. H., Manalastas, P. I., Fatehee, N., Yousefi, S., Belghith, A., Saunders, L. J., Medeiros, F. A., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18944 · Cited by 494
Self-citationOptical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Projection-resolved optical coherence tomographic angiography
Zhang, M., Hwang, T. S., Campbell, J. P., Bailey, S. T., Wilson, D. J., Huang, D., & Jia, Y. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000816 · Cited by 335
Self-citationTakusagawa, H. L., Liu, L., Ma, K. N., Jia, Y., Gao, S. S., Zhang, M., Edmunds, B., Parikh, M., Tehrani, S., Morrison, J. C., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.06.002 · Cited by 290
Self-citationRao, H. L., Pradhan, Z. S., Weinreb, R. N., Reddy, H. B., Riyazuddin, M., Dasari, S., Palakurthy, M., Puttaiah, N. K., Rao, D. A. S., & Webers, C. A. B. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.08.030 · Cited by 269
Yarmohammadi, A., Zangwill, L. M., Diniz-Filho, A., Saunders, L. J., Suh, M. H., Wu, Z., Manalastas, P. I. C., Akagi, T., Medeiros, F. A., & Weinreb, R. N. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.01.004 · Cited by 243
Akagi, T., Iida, Y., Nakanishi, H., Terada, N., Morooka, S., Yamada, H., Hasegawa, T., Yokota, S., Yoshikawa, M., & Yoshimura, N. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.06.009 · Cited by 233
“On the other hand, in a previous study by Liu et al.16, the peripapillary vessel densities significantly correlated with VF PSD, but not with VF MD or RNFLT.”
MethodResultInfluentialWang, Q., Chan, S., Yang, J. Y., You, B., Wang, Y. X., Jonas, J. B., & Wei, W. B. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.05.005 · Cited by 203
Koustenis, A., Harris, A., Gross, J., Januleviciene, I., Shah, A., & Siesky, B. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-309389 · Cited by 181
Mammo, Z., Heisler, M., Balaratnasingam, C., Lee, S., Yu, D.-Y., Mackenzie, P., Schendel, S., Merkur, A., Kirker, A., Albiani, D., et al. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.07.015 · Cited by 179
Moghimi, S., Zangwill, L. M., Penteado, R. C., Hasenstab, K., Ghahari, E., Hou, H., Christopher, M., Yarmohammadi, A., Manalastas, P. I. C., Shoji, T., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.05.006 · Cited by 177
Retinal vasculature in glaucoma: a review
Chan, K. K. W., Tang, F., Tham, C. C. Y., Young, A. L., & Cheung, C. Y. (2017) · BMJ Open Ophthalmology · doi:10.1136/bmjophth-2016-000032 · Cited by 170
Optical coherence tomography angiography: a review of current and future clinical applications
Ang, M., Tan, A. C. S., Cheung, C. M. G., Keane, P. A., Dolz-Marco, R., Sng, C. C. A., & Schmetterer, L. (2018) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-017-3896-2 · Cited by 166
“As primary open angle glaucoma (POAG) is an optic neuropathy with a possible vascular component in its multifactorial etiology [37], OCTA imaging suggests attenuation of the vasculature associatedwith the optic nerve headmicrovasculature [38, 39].”
BackgroundHuang, D., Hagag, A., Gao, S., & Jia, Y. (2017) · Taiwan Journal of Ophthalmology · doi:10.4103/tjo.tjo_31_17 · Cited by 164
“[22] Moreover, the correlation of glaucoma stage[157] with peripapillary OCTA measurements was higher than VF PSD or MD.[22] OCTA parameters could differentiate glaucoma suspects from both healthy subjects and confirmed glaucoma patients.”
BackgroundInfluentialSelf-citationNormal‐tension glaucoma: Current concepts and approaches‐A review
Leung, D. Y. L., & Tham, C. C. (2022) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.14043 · Cited by 99
Optical coherence tomography imaging for glaucoma - today and tomorrow
Leung, C. K.-S. (2016) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000179 · Cited by 17
Metadata
- Authors
- Liu, L., Jia, Y., Takusagawa, H. L., Pechauer, A. D., Edmunds, B., Lombardi, L., Davis, E., Morrison, J. C., & Huang, D.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2015-09-01
- Volume
- 133
- Issue
- 9
- Pages
- 1045
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W1580861603
- Cited by
- 657
- References
- 18
- FWCI
- 67.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.