CoChat

Oral appliances for obstructive sleep apnoea

Lim, J, Lasserson, TJ, Fleetham, J, Wright, J · 2004 · Cochrane Database of Systematic Reviews
Cited by 117

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Obstructive sleep apnoea-hypopnoea is a syndrome characterised by recurrent episodes of partial or complete upper airway obstruction during sleep that are usually terminated by an arousal. Nasal continuous positive airway pressure is the primary treatment for obstructive sleep apnoea-hypopnoea, but many patients are unable or unwilling to comply with this treatment. Oral appliances are an alternative treatment for sleep apnoea. OBJECTIVES: The objective was to review the effects of oral appliance in the treatment of sleep apnoea in adults. SEARCH STRATEGY: We searched the Cochrane Airways Group Sleep Apnoea RCT Register. Searches were current as of June 2004. Reference lists of articles were also searched. SELECTION CRITERIA: Randomised trials comparing oral appliance with control or other treatments in adults with sleep apnoea. DATA COLLECTION AND ANALYSIS: Trial quality was assessed and two reviewers extracted data independently. Study authors were contacted for missing information. MAIN RESULTS: Thirteen trials involving 553 participants were included. All the studies had some shortcomings, such as small sample size, under-reporting of methods and data, and lack of blinding. Oral appliances versus control appliances (five studies): Oral appliances reduced daytime sleepiness in two crossover trials (WMD -1.81 [95%CI: -2.72, -0.90]), and improved apnoea-hypopnoea index (AHI) (-13.17 [-18.53 to -7.80] parallel group data - four studies). Oral appliances versus CPAP (seven studies): Oral appliances were less effective than continuous positive pressure in reducing apnoea-hypopnoea index (WMD 13 [95% CI: 7.63, 18.36], parallel studies - two trials; WMD 6.96 [4.82, 9.10] cross-over studies - six trials). However, no significant difference was observed on symptom scores. Nasal continuous positive pressure was more effective at improving minimum arterial oxygen saturation during sleep compared with oral appliance. In two small crossover studies, participants preferred oral appliance therapy to continuous positive airways pressure. Oral appliances versus surgery (one study): Symptoms of daytime sleepiness were initially lower with surgery, but this difference disappeared at 12 months. AHI did not differ significantly initially, but did so after 12 months in favour of OA. REVIEWERS' CONCLUSIONS: There is some evidence suggesting that oral appliance improves subjective sleepiness and sleep disordered breathing compared with a control. Nasal continuous positive airways pressure appears to be more effective in improving sleep disordered breathing than oral appliance. Until there is more definitive evidence on the effectiveness of oral appliances, it would appear to be appropriate to restrict oral appliance therapy to patients with sleep apnoea who are unwilling or unable to comply with continuous positive airways pressure therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd004435.pub2

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 117

Metadata

Authors
Lim, J., Lasserson, T., Fleetham, J., & Wright, J.
Venue
Cochrane Database of Systematic Reviews
Published
2004-10-18
Issue
4
Pages
CD004435-CD004435
ISSN
1361-6137 (ISSN-L)
OpenAlex
W4243215475
Cited by
117
References
18
Type
reference entry
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.