Cerebral near-infrared spectroscopy (NIRS) for perioperative monitoring of brain oxygenation in children and adults
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Various techniques have been employed for the early detection of perioperative cerebral ischaemia and hypoxia. Cerebral near-infrared spectroscopy (NIRS) is increasingly used in this clinical scenario to monitor brain oxygenation. However, it is unknown whether perioperative cerebral NIRS monitoring and the subsequent treatment strategies are of benefit to patients. OBJECTIVES: To assess the effects of perioperative cerebral NIRS monitoring and corresponding treatment strategies in adults and children, compared with blinded or no cerebral oxygenation monitoring, or cerebral oxygenation monitoring based on non-NIRS technologies, on the detection of cerebral oxygen desaturation events (CDEs), neurological outcomes, non-neurological outcomes and socioeconomic impact (including cost of hospitalization and length of hospital stay). SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL 2016, Issue 12), Embase (1974 to 20 December 2016) and MEDLINE (PubMed) (1975 to 20 December 2016). We also searched the World Health Organization (WHO) International Clinical Trials Registry Platform for ongoing studies on 20 December 2016. We updated this search in November 2017, but these results have not yet been incorporated in the review. We imposed no language restriction. SELECTION CRITERIA: We included all relevant randomized controlled trials (RCTs) dealing with the use of cerebral NIRS in the perioperative setting (during the operation and within 72 hours after the operation), including the operating room, the postanaesthesia care unit and the intensive care unit. DATA COLLECTION AND ANALYSIS: statistic). We created a 'Summary of findings' table using GRADEpro. MAIN RESULTS: = 0%; 3 studies, 390 participants; low-quality evidence). There was no evidence to determine whether routine use of NIRS-based cerebral oxygenation monitoring causes adverse effects. AUTHORS' CONCLUSIONS: The effects of perioperative active cerebral NIRS monitoring of brain oxygenation in adults for reducing the occurrence of short-term, mild POCD are uncertain due to the low quality of the evidence. There is uncertainty as to whether active cerebral NIRS monitoring has an important effect on postoperative stroke, delirium or death because of the low number of events and wide confidence intervals. The conclusions of this review may change when the eight ongoing studies are published and the 12 studies awaiting assessment are classified. More RCTs performed in the paediatric population and high-risk patients undergoing non-cardiac surgery (e.g. neurosurgery, carotid endarterectomy and other surgery) are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Cochrane Handbook for Systematic Reviews of Interventions Version 5.0.1. The Cochrane Collaboration
Higgins, J. P. T., Green, S. R., & Higgins, J. P. T. (2008) · Cited by 7,261
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899 · cited 1×
“The work by Jöbsis pioneered the use of NIRS to monitor rScO2 (Jöbsis 1977). rScO2 is the percentage of oxy-haemoglobin over the sum of oxy- and deoxy-haemoglobin in pooled arterial, capillary and venous blood in the illuminated brain region. rScO2 is essentially determined by cerebral metabolic…”
MethodWhat is ‘quality of evidence’ and why is it important to clinicians?
Guyatt, G. H., Oxman, A. D., Kunz, R., Vist, G. E., Falck-Ytter, Y., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39490.551019.be · Cited by 3,250
Predictors of Cognitive Dysfunction after Major Noncardiac Surgery
Monk, T. G., Weldon, B. C., Garvan, C. W., Dede, D. E., van der Aa, M. T., Heilman, K. M., & Gravenstein, J. S. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296071.19434.1e · Cited by 1,534
Near-infrared spectroscopy as an index of brain and tissue oxygenation
Murkin, J. M., & Arango, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep299 · Cited by 877
Monitoring Brain Oxygen Saturation During Coronary Bypass Surgery: A Randomized, Prospective Study
Murkin, J. M., Adams, S. J., Novick, R. J., Quantz, M., Bainbridge, D., Iglesias, I., Cleland, A., Schaefer, B., Irwin, B., & Fox, S. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000246814.29362.f4 · Cited by 813
Slater, J. P., Guarino, T., Stack, J., Vinod, K., Bustami, R. T., Brown, J. M., Rodriguez, A. L., Magovern, C. J., Zaubler, T., Freundlich, K., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.08.070 · Cited by 626
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
Arterial and Venous Contributions to Near-infrared Cerebral Oximetry
Watzman, H. M., Kurth, C. D., Montenegro, L. M., Rome, J., Steven, J. M., & Nicolson, S. C. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00012 · Cited by 451
Casati, A., Fanelli, G. C., Pietropaoli, P., Proietti, R., Tufano, R., Danelli, G. F., Fierro, G., COSMO, G. D., & Servillo, G. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000166974.96219.cd · Cited by 368
A Proposed Algorithm for the Intraoperative Use of Cerebral Near-Infrared Spectroscopy
Denault, A. Y., Deschamps, A., & Murkin, J. M. (2007) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253207311685 · Cited by 367
Yao, F.-S. F., Tseng, C.-C. A., Ho, C.-Y. A., Levin, S. K., & Illner, P. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.007 · Cited by 351
Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics
MCCORMICK, P. W., STEWART, M., GOETTING, M. G., DUJOVNY, M., LEWIS, G., & AUSMAN, J. I. (1991) · Critical Care Medicine · doi:10.1097/00003246-199101000-00020 · Cited by 322
Zheng, F., Sheinberg, R., Yee, M.-S., Ono, M., Zheng, Y., & Hogue, C. W. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318277a255 · Cited by 299
Stys, P. K. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199801000-00002 · Cited by 287 · cited 1×
“B A C K G R O U N D Description of the condition The human brain is one of the organs with high oxygen utilization; thus it is extremely susceptible to hypoxic conditions (Gale 2004; Stys 1998).”
BackgroundCerebral Near-Infrared Spectroscopy in Adults: A Work in Progress
Ghosh, A., Elwell, C., & Smith, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31826dd6a6 · Cited by 277
Stroke after cardiac surgery: short- and long-term outcomes
Salazar, J. D., Wityk, R. J., Grega, M. A., Borowicz, L. M., Doty, J. R., Petrofski, J. A., & Baumgartner, W. A. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)02929-0 · Cited by 260
Ballard, C., Jones, E., Gauge, N., Aarsland, D., Nilsen, O. B., Saxby, B. K., Lowery, D., Corbett, A., Wesnes, K., Katsaiti, E., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037410 · Cited by 240
NIRS in clinical neurology — a ‘promising’ tool?
Obrig, H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.045 · Cited by 227 · cited 1×
“In addition, real-time brain oxygenation monitoring with cerebral NIRS may be beneficial for detecting ischaemic events during cerebrovascular procedures and in the neurosurgical ICU (Calderon-Arnulphi 2007; Grinspan 2014; Mazzeo 2012; Obrig 2014).”
MethodFactors Affecting the Performance of 5 Cerebral Oximeters During Hypoxia in Healthy Volunteers
Bickler, P. E., Feiner, J. R., & Rollins, M. D. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318297d763 · Cited by 222
Deschamps, A., Hall, R., Grocott, H., Mazer, C. D., Choi, P. T., Turgeon, A. F., de Medicis, E., Bussières, J. S., Hudson, C., Syed, S., et al. (2016) · Anesthesiology · doi:10.1097/aln.0000000000001029 · Cited by 218
Perioperative Stroke in Noncardiac, Nonneurosurgical Surgery
Ng, J. L. W., Chan, M. T. V., Gelb, A. W., & Warner, D. S. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31822e9499 · Cited by 209
Hoffman, G. M., Stuth, E. A., Jaquiss, R. D., Vanderwal, P. L., Staudt, S. R., Troshynski, T. J., Ghanayem, N. S., & Tweddell, J. S. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2003.08.021 · Cited by 197
Kussman, B. D., Wypij, D., Laussen, P. C., Soul, J. S., Bellinger, D. C., DiNardo, J. A., Robertson, R., Pigula, F. A., Jonas, R. A., & Newburger, J. W. (2010) · Circulation · doi:10.1161/circulationaha.109.902338 · Cited by 195
GALE, S. D., & HOPKINS, R. O. (2004) · Journal of the International Neuropsychological Society · doi:10.1017/s1355617704101082 · Cited by 195
Colak, Z., Borojevic, M., Bogovic, A., Ivancan, V., Biocina, B., & Majeric-Kogler, V. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu193 · Cited by 183
Neurological Monitoring for Congenital Heart Surgery
Andropoulos, D. B., Stayer, S. A., Diaz, L. K., & Ramamoorthy, C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000134808.52676.4d · Cited by 163
Taillefer, M.-C., & Denault, A. Y. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03018586 · Cited by 154
Near-infrared spectroscopy for monitoring cerebral ischemia during selective cerebral perfusion
Orihashi, K. (2004) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.06.014 · Cited by 150
Olsson, C., & Thelin, S. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.08.068 · Cited by 145
Cerebral oximetry and postoperative delirium after cardiac surgery: a randomised, controlled trial
Lei, L., Katznelson, R., Fedorko, L., Carroll, J., Poonawala, H., Machina, M. A., Styra, R. G., Rao, V. A., & Djaiani, G. N. (2017) · Anaesthesia · doi:10.1111/anae.14056 · Cited by 143
Near-infrared spectroscopy as a hemodynamic monitor in critical illness
Ghanayem, N. S., Wernovsky, G., & Hoffman, G. M. (2011) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e318221173a · Cited by 141
Hirsch, J. C., Charpie, J. R., Ohye, R. G., & Gurney, J. G. (2008) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.08.005 · Cited by 127
Near Infrared Brain and Muscle Oximetry: From the Discovery to Current Applications
Ferrari, M., & Quaresima, V. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.973 · Cited by 116
Guo, L., & Gelb, A. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.09.001 · Cited by 114
Yoshitani, K., Kawaguchi, M., Iwata, M., Sasaoka, N., Inoue, S., Kurumatani, N., & Furuya, H. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aei046 · Cited by 95
Lovell, A. T., Owen-Reece, H., Elwell, C. E., Smith, M., & Goldstone, J. C. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199903000-00017 · Cited by 93
Near Infrared Spectroscopy as a Hemodynamic Monitor in Critical Illness
Ghanayem, N. S., & Hoffman, G. M. (2016) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000000780 · Cited by 89
Calderon‐Arnulphi, M., Alaraj, A. M., Amin‐Hanjani, S., Mantulin, W. W., Polzonetti, C. M., Gratton, E., & Charbel, F. T. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.2.283 · Cited by 89
Recent Advances in Application of Cerebral Oximetry in Adult Cardiovascular Surgery
Fischer, G. W. (2008) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253208316443 · Cited by 84 · cited 1×
“The refined algorithm has improved the accuracy of cerebral NIRS (Fischer 2008).”
MethodWilliams, I. M., Picton, A., Farrell, A., Mead, G. E., Mortimer, A. J., & McCollum, C. N. (1994) · British journal of surgery · doi:10.1002/bjs.1800810911 · Cited by 83
Sood, E., Benzaquen, J. S., Davies, R. R., Woodford, E. J., & Pizarro, C. (2012) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.10.033 · Cited by 82
Hagino, I., Anttila, V., Zurakowski, D., Duebener, L. F., Lidov, H. G. W., & Jonas, R. A. (2005) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.02.058 · Cited by 77
Subramanian, B., Nyman, C. B., Fritock, M. D., Klinger, R. Y., Sniecinski, R. M., Roman, P., Huffmyer, J. L., Parish, M., Yenokyan, G., & Hogue, C. W. J. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001275 · Cited by 77
Kussman, B. D., Wypij, D., DiNardo, J. A., Newburger, J. W., Mayer, J. E., del Nido, P. J., BACHA, E. A., Pigula, F. A., McGrath, E. A., & Laussen, P. C. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318199dcd2 · Cited by 77
Hyttel-Sørensen, S., Greisen, G. O., Als-Nielsen, B. E. T., & Gluud, C. N. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011506.pub2 · Cited by 68
Kara, İ., Erkin, A., Saçlı, H., Demirtaş, M., Perçin, B., Diler, M. S., & Kırali, K. (2015) · Annals of Thoracic and Cardiovascular Surgery · doi:10.5761/atcs.oa.15-00118 · Cited by 65
Near Infrared Spectroscopy (NIRS) Should Not Be Standard of Care for Postoperative Management
Hirsch, J. C., Charpie, J. R., Ohye, R. G., & Gurney, J. G. (2010) · Seminars in Thoracic and Cardiovascular Surgery Pediatric Cardiac Surgery Annual · doi:10.1053/j.pcsu.2010.01.005 · Cited by 65
Vohra, H. A., Modi, A., & Ohri, S. K. (2009) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2009.206367 · Cited by 62
A multiwavelength frequency-domain near-infrared cerebral oximeter
Kurth, C. D., & Thayer, W. S. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/015 · Cited by 60
Bhatia, R., Hampton, T., Malde, S., Kandala, N., Muammar, M., Deasy, N., & Strong, A. J. (2007) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0b013e318031376d · Cited by 57
Inoue, T., Ohwaki, K., Tamura, A., Tsutsumi, K., Saito, I., & Saito, N. (2013) · Journal of neurosurgery · doi:10.3171/2013.1.jns121668 · Cited by 33
Meng, L., Mantulin, W. W., Alexander, B. S., Cerussi, A. E., Tromberg, B. J., Yu, Z., Laning, K., Kain, Z. N., Cannesson, M. P., & Gelb, A. W. (2012) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-011-9662-8 · Cited by 31
Self-citationMurkin, J. M., Adams, S. J., Pardy, E., Quantz, M., McKenzie, F., & Guo, L.-R. R. (2011) · The Heart Surgery Forum · doi:10.1532/hsf98.20101065 · Cited by 26
Specific Bypass Conditions Determine Safe Minimum Flow Rate
Anttila, V., Hagino, I., Zurakowski, D., et al. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2005.04.012 · Cited by 22
Regional venous oxygen saturation versus mixed venous saturation after paediatric cardiac surgery
Moreno, G. E., Pilán, M. L., MANARA, C., Magliola, R., Vassallo, J. C., BALESTRINI, M., Lenz, A. M., Krynski, M., Althabe, M., & Landry, L. (2012) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12016 · Cited by 21
Ellis, L. A., Murphy, G. J., Culliford, L. A., Dreyer, L., Clayton, G., Downes, R., Nicholson, E., Stoica, S. C., Reeves, B. C., & Rogers, C. A. (2015) · JMIR Research Protocols · doi:10.2196/resprot.4562 · Cited by 19
Grinspan, Z. M., Pon, S., Greenfield, J. P., Malhotra, S., & Kosofsky, B. E. (2014) · Seminars in Pediatric Neurology · doi:10.1016/j.spen.2014.10.005 · Cited by 18
Cerebral Oximetry to Reduce Perioperative Morbidity
Cowie, D. A., Nazareth, J. M., & Story, D. (2014) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1404200306 · Cited by 17
Cerebral perfusion monitoring in acute care surgery: current and perspective use
Tsai, H., Chung, P. C.-H., Lee, C., & Yu, H. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1219655 · Cited by 11
Metadata
- Authors
- Yu, Y., Zhang, K., Zhang, L., Zong, H., Meng, L., & Han, R.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2018-01-17
- Volume
- 2018
- Issue
- 1
- Pages
- CD010947-CD010947
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2124790768
- Cited by
- 179
- References
- 61
- FWCI
- 13.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.