The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Complex 3D‐Printed Microchannels within Cell‐Degradable Hydrogels
Abstract
3D‐printing is emerging as a technology to introduce microchannels into hydrogels, for the perfusion of engineered constructs. Although numerous techniques have been developed, new techniques are still needed to obtain the complex geometries of blood vessels and with materials that permit desired cellular responses. Here, a printing process where a shear‐thinning and self‐healing hydrogel “ink” is injected directly into a “support” hydrogel with similar properties is reported. The support hydrogel is further engineered to undergo stabilization through a thiol‐ene reaction, permitting (i) the washing of the ink to produce microchannels and (ii) tunable properties depending on the crosslinker design. When adhesive peptides are included in the support hydrogel, endothelial cells form confluent monolayers within the channels, across a range of printed configurations (e.g., straight, stenosis, spiral). When protease‐degradable crosslinkers are used for the support hydrogel and gradients of angiogenic factors are introduced, endothelial cells sprout into the support hydrogel in the direction of the gradient. This printing approach is used to investigate the influence of channel curvature on angiogenic sprouting and increased sprouting is observed at curved locations. Ultimately, this technique can be used for a range of biomedical applications, from engineering vascularized tissue constructs to modeling in vitro cultures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Local force and geometry sensing regulate cell functions
Vogel, V., & Sheetz, M. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1890 · Cited by 2,328
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Hydrogel bioprinted microchannel networks for vascularization of tissue engineering constructs
Bertassoni, L. E., Cecconi, M., Manoharan, V., Nikkhah, M., Hjortnaes, J., Cristino, A. L., Barabaschi, G., Demarchi, D., Dokmeci, M. R., Yang, Y., et al. (2014) · Lab Chip · doi:10.1039/c4lc00030g · Cited by 944
Direct 3D bioprinting of perfusable vascular constructs using a blend bioink
Jia, W., Gungor-Ozkerim, P. S., Zhang, Y. S., Yue, K., Zhu, K., Liu, W., Pi, Q., Byambaa, B., Dokmeci, M. R., Shin, S. R., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.07.038 · Cited by 922
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
Creating perfused functional vascular channels using 3D bio-printing technology
Lee, V. K., Kim, D. Y., Ngo, H., Lee, Y., Seo, L., Yoo, S.-S., Vincent, P. A., & Dai, G. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.05.083 · Cited by 494
Werner, M., Blanquer, S. B. G., Haimi, S. P., Korus, G., Dunlop, J. W. C., Duda, G. N., Grijpma, D. W., & Petersen, A. (2017) · Advanced Science · doi:10.1002/advs.201600347 · Cited by 345
A quantitative microfluidic angiogenesis screen for studying anti-angiogenic therapeutic drugs
Kim, C., Kasuya, J., Jeon, J., Chung, S., & Kamm, R. D. (2015) · Lab on a Chip · doi:10.1039/c4lc00866a · Cited by 143
A multilayered microfluidic blood vessel-like structure
Hasan, A., Paul, A., Memic, A., & Khademhosseini, A. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9993-2 · Cited by 139
Cited by
Translational Applications of Hydrogels
Correa, S., Grosskopf, A. K., Lopez Hernandez, H., Chan, D., Yu, A. C., Stapleton, L. M., & Appel, E. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01177 · Cited by 1,143
From Shape to Function: The Next Step in Bioprinting
Levato, R., Jungst, T., Scheuring, R. G., Blunk, T., Groll, J., & Malda, J. (2020) · Advanced Materials · doi:10.1002/adma.201906423 · Cited by 476
Daly, A. C., Davidson, M. D., & Burdick, J. A. (2021) · Nature Communications · doi:10.1038/s41467-021-21029-2 · Cited by 470
Self-citationFundamentals and Applications of Photo-Cross-Linking in Bioprinting
Lim, K. S., Galarraga, J. H., Cui, X., Lindberg, G. C. J., Burdick, J. A., & Woodfield, T. B. F. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00812 · Cited by 416
Self-citationExtrusion 3D Printing of Polymeric Materials with Advanced Properties
Jiang, Z., Diggle, B., Tan, M. L., Viktorova, J., Bennett, C. W., & Connal, L. A. (2020) · Advanced Science · doi:10.1002/advs.202001379 · Cited by 408
Metadata
- Authors
- Song, K. H., Highley, C. B., Rouff, A., & Burdick, J. A.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-06-07
- Volume
- 28
- Issue
- 31
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2807117701
- Cited by
- 241
- References
- 10
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complex 3D‐Printed Microchannels within Cell‐Degradable Hydrogels. https://app.cochat.ai/papers/10.1002/adfm.201801331
- The paper
- Song, K. H., Highley, C. B., Rouff, A., & Burdick, J. A. (2018). Complex 3D‐Printed Microchannels within Cell‐Degradable Hydrogels. Advanced Functional Materials. https://doi.org/10.1002/adfm.201801331
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.