Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Platelet–Leukocyte Hybrid Membrane‐Coated Immunomagnetic Beads for Highly Efficient and Highly Specific Isolation of Circulating Tumor Cells

Rao, Lang, Meng, Qian‐Fang, Huang, Qinqin, Wang, Zixiang, Yu, Guang‐Tao, Li, Andrew, Ma, Weijie, Zhang, Nangang, Guo, Shi‐Shang, Zhao, Xing‐Zhong, Liu, Kan, Yuan, Yufeng, Liu, Wei·2018·Advanced Functional Materials

Abstract

Biomimetic cell‐membrane‐camouflaged nanoparticles with desirable features have been widely used for various biomedical applications. However, the current research focuses on single cell membrane coating and using multiple cell membranes for nanoparticle functionalization is still challenging. In this work, platelet (PLT) and leukocyte (WBC) membranes are fused, PLT–WBC hybrid membranes are coated onto magnetic beads, and then their surface is modified with specific antibodies. The resulting PLT–WBC hybrid membrane‐coated immunomagnetic beads (HM‐IMBs) inherit enhanced cancer cell binding ability from PLTs and reduce homologous WBC interaction from WBCs, and are further used for highly efficient and highly specific isolation of circulating tumor cells (CTCs). By using spiked blood samples, it is found that, compared with commercial IMBs, the cell separation efficiency of HM‐IMBs is improved to 91.77% from 66.68% and the cell purity is improved to 96.98% from 66.53%. Furthermore, by using the HM‐IMBs, highly pure CTCs are successfully identified in 19 out of 20 clinical blood samples collected from breast cancer patients. Finally, the robustness of HM‐IMBs is verified in downstream CTC analysis such as the detection of PIK3CA gene mutations. It is anticipated that this novel hybrid membrane coating strategy will open new possibilities for overcoming the limitations of current theranostic platforms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201803531

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 226

Metadata

Authors
Rao, L., Meng, Q., Huang, Q., Wang, Z., Yu, G., Li, A., Ma, W., Zhang, N., Guo, S., Zhao, X., Liu, K., Yuan, Y., & Liu, W.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2018-07-13
Volume
28
Issue
34
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2885017820
Cited by
226
References
5
FWCI
9.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Platelet–Leukocyte Hybrid Membrane‐Coated Immunomagnetic Beads for Highly Efficient and Highly Specific Isolation of Circulating Tumor Cells. https://app.cochat.ai/papers/10.1002/adfm.201803531
The paper
Rao, L., Meng, Q., Huang, Q., Wang, Z., Yu, G., Li, A., Ma, W., Zhang, N., Guo, S., Zhao, X., Liu, K., Yuan, Y., & Liu, W. (2018). Platelet–Leukocyte Hybrid Membrane‐Coated Immunomagnetic Beads for Highly Efficient and Highly Specific Isolation of Circulating Tumor Cells. Advanced Functional Materials. https://doi.org/10.1002/adfm.201803531

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.