Biomimetic Cilia‐Patterned Rubber Electrode Using Ultra Conductive Polydimethylsiloxane
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this paper, a biomimetic cilia‐patterned flexible electrode using ultra conductive polydimethylsiloxane (PDMS) is presented. Due to the flexibility and cilia patterns, the developed electrode can have conformal contact with the human skin without interruptions of hair and rough skin. The conductive PDMS is prepared by mixing PDMS prepolymer and curing agent with Ag particles at different ratios. The performance of the best composite‐made ciliated electrode is evaluated under different skin‐like physical environments, and compared to the nonciliated flat electrode. For a typical flat electrode, hair and rough surface of the human skin disturb electrical contact, increasing contact impedance, whereas flexible ciliary structures of the proposed electrode show significantly improved conductivity passing through the furs to penetrate well into the gap on the alloyed skin, thus increasing the contact areas. Furthermore, bio‐signal measurement using rigid metal electrodes suffers from motion artifacts causing signal errors due to bodily movement, which is remarkably addressed by ciliated flexible electrode. Therefore, the proposed electrode is applied to recording electrocardiography signal and compared with signal measured with conventional metal electrode, which showed about 20% enhancement than that of metal counterpart in identifying electrical activity of heart muscle of a person, as point‐of‐care clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Electrocardiographic Artifacts
Keller, K. B., & Lemberg, L. (2007) · American Journal of Critical Care · doi:10.4037/ajcc2007.16.1.90 · Cited by 4
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Metadata
- Authors
- Jin, G. J., Uddin, M. J., & Shim, J. S.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-09-11
- Volume
- 28
- Issue
- 50
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2892011247
- Cited by
- 35
- References
- 2
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomimetic Cilia‐Patterned Rubber Electrode Using Ultra Conductive Polydimethylsiloxane. https://app.cochat.ai/papers/10.1002/adfm.201804351
- The paper
- Jin, G. J., Uddin, M. J., & Shim, J. S. (2018). Biomimetic Cilia‐Patterned Rubber Electrode Using Ultra Conductive Polydimethylsiloxane. Advanced Functional Materials. https://doi.org/10.1002/adfm.201804351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.