Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Conductive and Stretchable Adhesive Electronics with Miniaturized Octopus‐Like Suckers against Dry/Wet Skin for Biosignal Monitoring

Chun, Sungwoo, Kim, Da Wan, Baik, Sangyul, Lee, Heon Joon, Lee, Jung Heon, Bhang, Suk Ho, Pang, Changhyun·2018·Advanced Functional Materials

Abstract

High adhesion and water resistance on skin surfaces are highly demanded properties for wearable and skin‐attachable electronics in various medical applications. Here, stretchable electronics with octopus‐like patterns (OPs) imprinted on a carbon‐based conductive polymer composite (CPC) film are presented. The bioinspired conductive suckers with dome‐like architectures are successfully exploited to sustain weight (500 g) in underwater, wherein this performance is known to be challenging. In addition, the artificial patch allows highly adhesive capabilities under both dry and wet conditions on various surfaces such as silicon (max. 5.24 N cm−2) and skin replica (max. 1.89 N cm−2) without contamination after detachment with an effortless peel‐off technique. The resulting device with low volumetric ratio of conductive carbon black presents sensitive and reliable piezoresistive responses to lateral strain and vertical pressure. By controlling the ratio of the carbon nanoplatelets in the polymeric matrix, electronic patch demonstrates both detection of electrocardiogram (ECG) and bending motions of wrist in dry and wet environments. Based on the characteristics shown in this work, the proposed electronic patch is a promising approach to realize wearable and skin‐attachable sensor devices for in vitro and in vivo monitoring of various biosignals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201805224

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 195

Metadata

Authors
Chun, S., Kim, D. W., Baik, S., Lee, H. J., Lee, J. H., Bhang, S. H., & Pang, C.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2018-11-09
Volume
28
Issue
52
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2900054861
Cited by
195
References
7
FWCI
6.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conductive and Stretchable Adhesive Electronics with Miniaturized Octopus‐Like Suckers against Dry/Wet Skin for Biosignal Monitoring. https://app.cochat.ai/papers/10.1002/adfm.201805224
The paper
Chun, S., Kim, D. W., Baik, S., Lee, H. J., Lee, J. H., Bhang, S. H., & Pang, C. (2018). Conductive and Stretchable Adhesive Electronics with Miniaturized Octopus‐Like Suckers against Dry/Wet Skin for Biosignal Monitoring. Advanced Functional Materials. https://doi.org/10.1002/adfm.201805224

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.