NIR‐II Excitable Conjugated Polymer Dots with Bright NIR‐I Emission for Deep In Vivo Two‐Photon Brain Imaging Through Intact Skull
Abstract
Methods for noninvasive brain imaging are highly desirable to study brain structures in neuroscience. Two‐photon fluorescence microscopy (2PFM) with near‐infrared (NIR) light excitation is a relatively noninvasive approach commonly used to study brain with high spatial resolution and large imaging depth. However, most of the current studies require cranial window implantation or skull‐thinning methods due to attenuation of excitation light. 2PFM through intact mouse skull is challenging due to strong scattering induced by skull bone. Herein, NIR‐II light excitable single‐chain conjugated polymer dots (CPdots) with bright fluorescence in NIR‐I region (peak at ≈725 nm and quantum yield of 20.6 ± 1.0%) are developed for deep in vivo two‐photon fluorescence (2PF) imaging of intact mouse brain. The synthesized CPdots exhibit good biocompatibility, high photostability, and large two‐photon absorption cross section. The CPdots allow 2PF images acquired upon excitation at 800, 1040 and 1200 nm with the highest signal‐to‐background ratio of 208 demonstrated for 1200 nm excitation. Moreover, a 3D reconstruction of the brain blood vessel network is obtained with a large vertical depth of 400 µm through intact skull. This work demonstrates great potential of bright NIR fluorophores for in vivo deep tissue imaging.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Through-skull two-photon microscopy revealed blood vasculature architectures in bone marrow within the skull and beneath the skull with a high image contrast at a depth of 400 μm.
“Through-skull two-photon microscopy revealed blood vasculature architectures in bone marrow within the skull and beneath the skull with a high image contrast at the depth of 400 μm.201”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [201]
Two-photon fluorescence microscopy imaging of blood vessels in mouse brain with a cranial window stained by PIDTDBT Pdots reached a depth of 1010 μm using 1200 nm fs laser excitation.
“Two-photon fluorescence microscopy imaging of blood vessels in mouse brain with a cranial window stained by the Pdots reached the depth of 1010 μm using 1200 nm fs laser excitation provided.”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [201]
Cites
Deep optical imaging of tissue using the second and third near-infrared spectral windows
Sordillo, L. A., Pu, Y., Pratavieira, S., Budansky, Y., & Alfano, R. R. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.056004 · Cited by 407 · see citing works
Chronic optical access through a polished and reinforced thinned skull
Drew, P. J., Shih, A. Y., Driscoll, J. D., Knutsen, P. M., Blinder, P., Davalos, D., Akassoglou, K., Tsai, P. S., & Kleinfeld, D. (2010) · Nature Methods · doi:10.1038/nmeth.1530 · Cited by 406 · see citing works
Wang, Y., Chen, M., Alifu, N., Li, S., Qin, W., Qin, A., Tang, B. Z., & Qian, J. (2017) · ACS Nano · doi:10.1021/acsnano.7b05645 · Cited by 177 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Fluorination Enhances NIR‐II Fluorescence of Polymer Dots for Quantitative Brain Tumor Imaging
Liu, Y., Liu, J., Chen, D., Wang, X., Zhang, Z., Yang, Y., Jiang, L., Qi, W., Ye, Z., He, S., et al. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202007886 · Cited by 173 · see citing works
Self-citationWang, S., Liu, J., Goh, C. C., Ng, L. G., & Liu, B. (2019) · Advanced Materials · doi:10.1002/adma.201904447 · Cited by 148 · see citing works
Self-citationTwo-Photon Absorption: An Open Door to the NIR-II Biological Window?
Shaw, P. A., Forsyth, E., Haseeb, F., Yang, S., Bradley, M., & Klausen, M. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.921354 · Cited by 75 · see citing works
Piwoński, H., Nozue, S., & Habuchi, S. (2022) · ACS Nanoscience Au · doi:10.1021/acsnanoscienceau.1c00038 · Cited by 39 · see citing works
- Authors
- Wang, S., Liu, J., Feng, G., Ng, L. G., & Liu, B.
- Affiliations
- National University of Singapore (SG)
- Nanjing Tech University (CN)
- Agency for Science, Technology and Research (SG)
- Corresponding author
- Liu, Bin
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-01-21
- Volume
- 29
- Issue
- 15
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2911303457
- Cited by
- 110
- References
- 3
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 14 · 2023: 15 · 2022: 23 · 2021: 16 · 2020: 26 · 2019: 9
- FWCI
- 6.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Functional Materials (publishedVersion)
- National University of Singapore (submittedVersion)
- Funders
- National Research Foundation Singapore (R279‐000‐483‐281)
- National University of Singapore (R279‐000‐482‐133)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
- Keywords
- two-photon fluorescence imaging, deep tissue imaging, neuroimaging, two-photon absorption cross section, biocompatibility, photostability, mouse brain
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review