Thermoresponsive Semiconducting Polymer Nanoparticles for Contrast‐Enhanced Photoacoustic Imaging
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Photoacoustic (PA) agents with biomarker‐activated signals are developed to enhance the signal‐to‐background ratios (SBRs) for in vivo imaging; however, their SBRs still heavily rely on the concentration difference of biomarkers between diseased and normal tissues. By contrast, external stimuli can provide a remote way to noninvasively control the signal generation from the PA agents and in turn enhance SBR, which are less exploited. This study reports the development of thermoresponsive semiconducting polymer brush with poly(N,N‐dimethylacrylamide)‐r‐(hydroxypropyl acrylate) (PDMA‐r‐HPA) grafts for contrast‐enhanced in vivo imaging. Such a polymer is amphiphilic and can self‐assemble into the nanoparticle (termed as SPNph1) in an aqueous medium, and has lower critical solution temperatures (LCSTs) at 48 °C. Thus, SPNph1 not only has higher photothermal conversion efficiency than the control polymer without PDMA‐r‐HPA grafts, but also can undergo phase separation to form large nanoparticles, leading to enhanced PA signals above LCST. The thermoresponsive PA property of SPNph1 enables in situ remote manipulation of PA signals by photoirradiation to further enhance the tumor SBR. Thus, this study introduces a new generation of organic PA agents with thermoresponsive signal for high‐contrast in vivo imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Highly Fluorescent Semiconducting Polymer Dots for Biology and Medicine
Wu, C., & Chiu, D. T. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201205133 · Cited by 1,101
Ultralong Phosphorescence of Water‐Soluble Organic Nanoparticles for In Vivo Afterglow Imaging
Zhen, X., Tao, Y., An, Z., Chen, P., Xu, C., Chen, R., Huang, W., & Pu, K. (2017) · Advanced Materials · doi:10.1002/adma.201606665 · Cited by 602
Self-citationHong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Cited by
Second near-infrared photothermal materials for combinational nanotheranostics
Xu, C., & Pu, K. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00664e · Cited by 941
Self-citationSemiconducting Polycomplex Nanoparticles for Photothermal Ferrotherapy of Cancer
He, S., Jiang, Y., Li, J., & Pu, K. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202003004 · Cited by 299
Self-citationZhen, X., Pu, K., & Jiang, X. (2021) · Small · doi:10.1002/smll.202004723 · Cited by 245
Self-citationChemical Design of Activatable Photoacoustic Probes for Precise Biomedical Applications
Liu, Y., Teng, L., Yin, B., Meng, H., Yin, X., Huan, S., Song, G., & Zhang, X.-B. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00875 · Cited by 245
Ultrasound-Based Micro-/Nanosystems for Biomedical Applications
Huang, H., Zheng, Y., Chang, M., Song, J., Xia, L., Wu, C., Jia, W., Ren, H., Feng, W., & Chen, Y. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00009 · Cited by 183
Metadata
- Authors
- Cui, D., Li, P., Zhen, X., Li, J., Jiang, Y., Yu, A., Hu, X., & Pu, K.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-07-19
- Volume
- 29
- Issue
- 38
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2963635670
- Cited by
- 74
- References
- 4
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.