Pro‐Healing Zwitterionic Skin Sensor Enables Multi‐Indicator Distinction and Continuous Real‐Time Monitoring
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In both artificial electronic and ionic skins, the distinction of multi‐stimuli response in a single sensing unit is challenging, due to unavoidable mutual signal interference. Here, a zwitterionic skin sensor system that can continuously monitor and differentiate three‐stimuli‐responsive information in real‐time is designed. This sandwich‐structured sensor system is based on a zwitterionic thermo–glucose‐sensitive skin‐like hydrogel at its upper and lower layers with a middle isolation elastomer layer, enabling monitoring and distinction of temperature, mechanical and glucose information without signal interference: 1) the capacitance of the upper/lower layers as glucose–temperature‐insensitive is variable to measure strain; 2) the resistance of the upper hydrogel as glucose‐insensitive is variable to measure strain and temperature; and 3) the resistance of the lower hydrogel can detect three indicators. Based on the skin sensor system, a smart wound dressing is developed to pro‐heal chronic diabetic wounds and enable continuous real‐time monitoring of three indicators—infection, swelling, and blood glucose. This work provides a new method of real‐time monitoring and the distinction of multi‐stimuli response in a wearable device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035
Self-citationRecent Progress in Electronic Skin
Wang, X., Dong, L., Zhang, H., Yu, R., Pan, C., & Wang, Z. L. (2015) · Advanced Science · doi:10.1002/advs.201500169 · Cited by 976
An adaptive ionic skin with multiple stimulus responses and moist-electric generation ability
Pan, X., Wang, Q., Guo, R., Cao, S., Wu, H., Ouyang, X., Huang, F., Gao, H., Huang, L., Zhang, F., et al. (2020) · Journal of Materials Chemistry A · doi:10.1039/c9ta13407g · Cited by 66
Cited by
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Self-citationProgress in Hydrogels for Skin Wound Repair
Qi, L., Zhang, C., Wang, B., Yin, J., & Yan, S. (2022) · Macromolecular Bioscience · doi:10.1002/mabi.202100475 · Cited by 267
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Self-Powered Multifunction Ionic Skins Based on Gradient Polyelectrolyte Hydrogels
Xia, M., Pan, N., Zhang, C., Zhang, C., Fan, W., Xia, Y., Wang, Z., & Sui, K. (2022) · ACS Nano · doi:10.1021/acsnano.1c11505 · Cited by 138
Metadata
- Authors
- Guo, H., Bai, M., Zhu, Y., Liu, X., Tian, S., Long, Y., Ma, Y., Wen, C., Li, Q., Yang, J., & Zhang, L.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2021-09-12
- Volume
- 31
- Issue
- 50
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3200588799
- Cited by
- 148
- References
- 3
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pro‐Healing Zwitterionic Skin Sensor Enables Multi‐Indicator Distinction and Continuous Real‐Time Monitoring. https://app.cochat.ai/papers/10.1002/adfm.202106406
- The paper
- Guo, H., Bai, M., Zhu, Y., Liu, X., Tian, S., Long, Y., Ma, Y., Wen, C., Li, Q., Yang, J., & Zhang, L. (2021). Pro‐Healing Zwitterionic Skin Sensor Enables Multi‐Indicator Distinction and Continuous Real‐Time Monitoring. Advanced Functional Materials. https://doi.org/10.1002/adfm.202106406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.