CoChat

Body‐Monitoring and Health Supervision by Means of Optical Fiber‐Based Sensing Systems in Medical Textiles

Open access
Quandt, Brit M., Scherer, Lukas J., Boesel, Luciano F., Wolf, Martin, Bona, Gian‐Luca, Rossi, René M. · 2015 · Advanced Healthcare Materials
Cited by 148

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Long‐term monitoring with optical fibers has moved into the focus of attention due to the applicability for medical measurements. Within this Review, setups of flexible, unobtrusive body‐monitoring systems based on optical fibers and the respective measured vital parameters are in focus. Optical principles are discussed as well as the interaction of light with tissue. Optical fiber‐based sensors that are already used in first trials are primarily selected for the section on possible applications. These medical textiles include the supervision of respiration, cardiac output, blood pressure, blood flow and its saturation with hemoglobin as well as oxygen, pressure, shear stress, mobility, gait, temperature, and electrolyte balance. The implementation of these sensor concepts prompts the development of wearable smart textiles. Thus, current sensing techniques and possibilities within photonic textiles are reviewed leading to multiparameter designs. Evaluation of these designs should show the great potential of optical fibers for the introduction into textiles especially due to the benefit of immunity to electromagnetic radiation. Still, further improvement of the signal‐to‐noise ratio is often necessary to develop a commercial monitoring system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.201400463

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 148

Metadata

Authors
Quandt, B. M., Scherer, L. J., Boesel, L. F., Wolf, M., Bona, G., & Rossi, R. M.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2014-10-30
Volume
4
Issue
3
Pages
330-355
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W2097760619
Cited by
148
References
11
FWCI
4.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Body‐Monitoring and Health Supervision by Means of Optical Fiber‐Based Sensing Systems in Medical Textiles. https://app.cochat.ai/papers/10.1002/adhm.201400463
The paper
Quandt, B. M., Scherer, L. J., Boesel, L. F., Wolf, M., Bona, G., & Rossi, R. M. (2015). Body‐Monitoring and Health Supervision by Means of Optical Fiber‐Based Sensing Systems in Medical Textiles. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201400463

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.